1. Features of Preparation Equipment

Slides:



Advertisements
Similar presentations
COSHH ASSESSMENT TRAINING Essential Elements of a COSHH Form.
Advertisements

Save Energy, Save the planet
Introduce yet another South African First – A GREEN way of cleaning wall-splits We have two services The A Services done annually The B service done quarterly.
Review of Analytical Methods for Nutrient Parameters focusing on Nitrates An Overview By Michael Jackman Chemistry Expert.
Experiment 15 Chemical Kinetics.
Analytical services for growers. Analytical services What farmers want to know Farmers and other growers send sample of soil, leaf tissue and fertilisers.
THE COMPOSITION OF PENNIES PRE-1982 AND POST-1982 Tim Cumming & Caitlin Carmody.
SURVEY OF CHEMISTRY LABORATORY I
1 Ca 2+ + CO 3 2- CaCO 3 NH 3 + H + NH 4 + Zn + 2HCl ZnCl 2 + H 2 Ca + F 2 CaF 2 Precipitation Acid-Base Redox (H 2 Displacement) Redox (Combination) Classify.
Experiment 4 Preparation of Isoamyl acetate. H 2 SO 4 + H 2 O.
Lead Content in Toys Katrina Nowak Chemistry 4101 Fall 2008.
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
Marble is just CaCO3 Gravimetric Determination of Ca
Matter. Review States of Matter Solid Liquid Gas Plasma.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Laboratory 14: CRSS/FANR 3060 Spring Urban soils often contaminated with metals (Pb) Refining, smelting (aerial deposition) Plumbing (Pb solder)
Tuesday Safety Talk: Aqua Regia & Piranha Acid
J 5A Molar Volume Lab Molar volume is the volume occupied by one mole of gas collected at standard temperature and pressure or STP.
Lecture 7: Digestion of Samples Digestion of water samples with Kjeldhl method for determination of N Destruction and extraction of soil and sludge for.
4.8 To prepare and show the production of alcohol by yeast.
Monday, September 26, This week... Monday - data sharing, fecal coliform test Tuesday - Water lecture Wednesday - Nitrate and Phosphate tests.
ICP MAKING STANDARDS. NUMBER OF STANDARDS Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc)
How Much Mercury Is In Your Soil? Aubrey Lewis Freeport High School Mr. Irwin and Ms. Lewis.
Lab Equipment. hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated.
The Islamic University of Gaza- Environmental Engineering Department
Lab Activity 4 A. Extraction & Determination of Crude Fat from Plant or Animal Tissues B. Determination of Dry Matter and Moisture Content In Plant Materials.
Temperature profiles for a nature gas/air flame.
1 Splash proof googles must be worn at all times! No food or drinks are allowed in the laboratory. Cover skin as much as possible; no open-toed shoes.
Aqua Regia.
General Laboratory supplies
ODLAB The Graphite Block Acid Digestion System (ECO-PRE)
Better Safety, Better Effectiveness Well suited for digestion by acids Proposal New idea for pretreatment of sample analysis ECOPRE-SYSTEM.
Lab Equipment.
By Maryum Atique M.Phill chemistry University of Agriculture.
Sample Problem 8.1 Properties of Gases
9.5 Dilution of Solutions In a dilution, a solvent, usually water, is added to a solution, which increases its volume and decreases the concentration.
Lab Equipment.
Eric Burgstrom, Rebecca Haley, Keaton Nahan, Dr. James Mack and Dr
Michael Raessler, Jan Rothe and Ines Hilke
Sediment Sample Digestion Method
1.
Heavy metals concentration of Fecal Solids of Recirculating Aquaculture System for Renewal Feed Resource for Sea Cucumber Anisuzzaman Md, Feng Jin, Ga-Hyun.
Zhifeng Zhang Division of Marine Environmental Chemistry
Atomic emission spectrometry
Current Status Chemical Metrology Sub Division, RCM LIPI
Chapter 16 “Solutions”.
Corn Mash and Distillation
The Analysis of Soils and Waters in Accordance with U. S
Matter.
Common Environmental Factors
Matter Lesson 6.
Erlenmeyer Flask An Erlenmeyer Flask is a cone-shaped container with neck, so you can hold the flask or attach a clamp or use a stopper. They are used.
بر اساس جدول تناوبی از یک جایی به بعد فلزات سنگین قرار دارند
Chemical Reactions and Balancing Equations
Quantifying the Efficiency of Different Solid Sample Digestion Methods: A Comparison of Time, Cost, and Accuracy Connie Hayes.
Reaction time زمن الرجع.
GROUP II CATIONS As+3, As+5, Sb+3, Sb+5, Sn+2,
GROUP II CATIONS SUPERNATANT A: AsO3-3, AsS3-3, SbO2-, SbS2-, SnO2-2
Chapter 4 Section 2.
Jeopardy whats the matter?.
Clean air?.
Sediment Sample Digestion Method
By: Valeria and Priscilla
ICP-OES ANALYSIS METHOD DEVELOPMENT FOR MINE WASTES
How Healthy is Your Water?
Lab 1 Laboratory apparatus م.م. نورا زاوار م.م زينة داود
Lab 1 Laboratory apparatus م.م. نورا زاوار م.م زينة داود
Aqua Regia and Nitric acid Safety
Experiment 1 Analysis of Some Common Anions
Presentation transcript:

1. Features of Preparation Equipment Official soil pollution test equipment Auto reflux condenser equipment EcoPre Digestion System 1. Features of Preparation Equipment In the official soil pollution test, digestion using aqua regia has difficulty in preparation because of gas. In other words, it is not easy to get reliable results depending on a work environment. There is a limit to the amount of sample for digestion using the official soil pollution test equipment. So, many research institutions are using auto reflux condenser equipment. It is possible to digest lots of samples using auto reflux condenser equipment. However, reaction vessel is too narrow to fill acid and sample, so sample including high organic matter makes bubbles and goes up. Therefore, an engineer can not clean equipment simply and may cut part of it to clean. There are problems that sample could be overflow when filtering due to long reaction vessel and it is dangerous for workers to get hurts by fragile glass. EcoPre digestion system is not using water cooling system but both reaction vessel and absorption vessel are very simple. Especially, infrangible Teflon material is safe and both filtering and cleaning are very simple. 24 samples can be preprocessed at the same time, so it saves time. Official soil pollution test equipment : available to sample including high organic matter due to wide surface area limited quantity of digestion. Can not check temperature. Auto reflux condenser equipment : fatal in sample including high organic matter due to narrow surface area. Glass material will be fragile and reaction vessel is too long to analyze. Works only if hood is installed. EcoPre Digestion System: Safe Teflon material. Easy preparation using small vessels. Available to digest a quantity of sample

2. CRM Results from Equipment Test results from three types of equpment Equipment ICP-OES Sample Cd (mg/kg) Cu (mg/kg) Pb (mg/kg) As (mg/kg) Zn (mg/kg) Ni (mg/kg) BAM-U110 Certified Values 7.0 ±0.4 262 ±9 185 ±8 13.0 ±1.1 990 ± 40 95.6 ±4.0 K-BAM 7.03 266.50 188.13 14.60 1074.32 99.97 I-BAM 7.10 255.93 182.50 13.53 1025.66 97.53 G-BAM 6.80 254.50 180.83 14.47 1030.32 94.00 T-BAM 6.93 255.36 185.13 14.20 1049.32 93.07 N-BAM 7.00 259.43 185.50 13.83 1058.32 94.90 2. CRM results from preparation equipment Analyze CRM(BAM-U110) using Official soil test equipment, Auto reflux condenser equipment, and EcoPre Digestion System. K-BAM, I-BAM(ISO 11466) means Official soil test equipment. I-BAM stand at room temperature for 16 hour and others stand for 2 hours. G-BAM means Auto reflux condenser equipment. T-BAM and N-BAM means EcoPre Digestion system. N-BAM is the result from processing using half of sample and acid. K-BAM: Official soil test digestion equipment (250mL-Vessel, Soil 3g- HCl 21mL, HNO3 7mL) I-BAM: KS ISO 11466 (250mL-Vessel, Soil 3g- HCl 21mL, HNO3 7mL) G-BAM: Official soil test (250mL-Glass, Soil 3g- HCl 21mL, HNO3 7mL) T-BAM: Official soil test (100mL-Teflon, Soil 3g- HCl 21mL, HNO3 7mL) N-BAM: Official soil test (100mL-Teflon, Soil 1.5g- HCl 10.5mL, HNO3 3.5mL)