FTIR - SOME LESSONS LEARNED

Slides:



Advertisements
Similar presentations
EPA Methods 3A, 6C, 7E, 10 & 20 Corrections to May 15, 2006 Final Rule That Updated the Methods That Updated the Methods Foston Curtis US EPA.
Advertisements

Gas Detection Strategies Overview of Selection Criteria for Gas Detection Systems.
EPA Proposed Mandatory Greenhouse Gas Reporting Rule.
EPA Proposed Mandatory Greenhouse Gas Reporting Rule.
EPA Proposed Mandatory Greenhouse Gas Reporting Rule.
Safety Driven Performance 2013
Ronald L. Baker Robert Peters Edul Chikhliwala EcoChem Analytics
Lessons Learned from Sarnia Area Monitoring Presented by: Ed Kuley ORTECH Environmental November 6, 2014.
Mentoring Session Technical Assistance Committee Method Modifications.
Reporting 2013 Emissions Inventories. Emissions Inventory Workshop 2014 Introduction Introduction Mark Gibbs 2.
Fresh Air Consulting Norman L. Morrow, Ph.D. November 5, 2003 MON Continuous PV Requirements.
Materials Lifecycle Solutions MACT DEVELOPMENT DEFINITIONS HAP - HAZARDOUS AIR POLLUTANTS: FEDERAL LIST OF 188 COMPOUNDS AND COMPOUND CATAGORIES. COMMON.
World Health Organization
A History and Status of CEMS Applications in USEPA Regulations Dale Evarts US EPA December 16, 2002 Better Air Quality in Asian Cities 2002
Real Time Emission Measurements Using FTIR Spectroscopy (EPA Method 320) Jeffrey LaCosse Spectral Insights LLC December 8,
Kim Garnett Measurement Technology Workshop 2013 January 29-31, 2013.
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
Particulate Matter Monitoring Required by the Utility MATS Eric Swisher| | ext. 17 August 22, 2012 Presented to ARIPPA.
Quality assurance of sampling and analytical instruments
Analytical chemistry MLAB 243 Level 4 Lecture time: every WED 8 -10
Neutralization Reactions & Environment
Greenhouse Gas (GHG) Permit Training Region 4 – Atlanta, GA Dec , 2010.
 Products of incineration  sifting  fine material include ash, metal fragments, glass, unburnt organic substances etc..  residue  all solid material.
Electronic Reporting Tool Software to Standardize Source Test Planning, Reporting and Assessment and Assessment Measurement Technology Workshop 12/8/2010.
Ammonia Measurement Techniques Ji-Qin (Jee-Chin) Ni, Ph.D. Dept. of Agricultural and Biological Engineering Purdue University October 21, 2008 Albuquerque,
The Paper and Other Web Coating (POWC) MACT – Executive Summary The executive summary is a power point presentation designed to be used for basic education.
William Telliard U.S. EPA Office of Science and Technology
A presentation for by ROUX ASSOCIATES, INC. Environmental Consulting and Management International Petroleum Environmental Conference 22.
HF Modeling Task Mike Williams November 19, 2013.
Emission source sampling and monitoring Topic 6 Ms Sherina Kamal May
What are the two equations used to calculate rates? Rate of reaction = amount of reactant used Time And Rate of reaction = C2 REVISION – Section C2.4.1.
Standards Certification Education & Training Publishing Conferences & Exhibits Expanding LDAR Technology to Tank Vents and Compressor Seals Michael Webb,
Achieving Method Compliance with Innovative Technologies Tony Francis, PhD Principal, SAW Environmental TCEQ – Environmental Trade.
The sole purpose of this chapter is to ask students to: Be aware. Be mindful. Know your facts. For YOU. Not for us. This chapter, as any other, prompts.
Robert S. Wright US EPA, Research Triangle Park, NC EPA Protocol Gases Fall 2012 Update PurityPlus Specialty Gas Producers.
What is Degassing? Degassing is removing dissolved gases from liquids. Applications includes: Removing biogenic hydrogen sulfide from groundwater, used.
Fundamentals of Analytical Chemistry Eighth Edition.
The BioTector B7000i TOC analyzer with integrated oxygen concentrator
Determinations and Interpretations of FTIR Detection Limits
Lecture (11): Waste Recycling
Determination of TKN by Subtraction using ASTM D and ASTM D
The Greenhouse Gas Connection to Sustainable Resource Management
T. Higgs May 25, 2017 AESA Stack Testing Seminar
C2 REVISION – Section C2.4.1 – Rates of Reaction
Clean Water Act Methods Overview of EPA’s CWA Method Activities
Specialists in environmental solutions
Air Control Techniques, P.C.
Complying with Periodic Emissions Monitoring Requirements
Flame Emission Spectrometry
Method Modifications & ATP 40 CFR part and 136.5
U.S. Environmental Protection Agency Natural Gas STAR Program
Status of EPA Method 1631 for the Determination of Low-Level Mercury
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Stack Sampling.
EPA Method Equivalency
Rules for Existing Municipal Solid Waste Landfills
Do’s and Don'ts of SF6Gas Handling
Chemistry-Part 2 Notes Chemical Bonding
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
IMMA proposal for GTR2 B2 on NMHC and CFV
Ventilation Measurement Tracer Gas Decay Testing
Voluntary SF6 Emission Reduction Partnership: Recent Achievements and Planned Activities Volha Roshchanka 14 November, 2018.
Neutralization Reactions & Environment
Preparing for a Stack Test
TCEQ Environmental Trade Fair Water Quality Division
EPA/OAQPS Pollutant Emissions Measurement Update 2019
Presentation transcript:

FTIR - SOME LESSONS LEARNED Mike Sherer, Trinity Consultants May 25, 2017

UNDERSTANDING PROCESSES AND CHEMISTRIES

AMMONIUM COMPOUNDS FORMATION Ammonium compounds are formed when ammonia and acid gases meet in exhaust system. NH3 + HF → NH4F NH3 + HCl → NH4Cl 2NH3 + SiF4 + 2HF → (NH4)2SiF6 From above ammonium compounds and if you want to measure ammonia and acid gases, need to review what happens to ammonium compounds in sampling system and Fourier transform infrared (FTIR) spectroscopy. 4

ABATEMENT DEVICES DRE FTIR measures concentrations in parts per million by volume (ppmv). Destruction and removal efficiency (DRE) is calculated by inlet and outlet mass rates. % DRE = ((inlet mass rate) – (outlet mass rate))(100%) (inlet mass rate)

UNDERSTANDING SAMPLING LOCATIONS

CENTRALIZED ACID SCRUBBER

ROTOR CONCENTRATOR/THERMAL OXIDIZER (RCTO)

FTIR SAMPLING METHODS EXAMPLES

USEPA METHOD 320 Utilizes FTIR. Continuous measurements of hydrogen chloride, hydrogen fluoride, greenhouse gases (GHGs), organic compounds, etc. Cannot not be used for mononuclear diatomics and inert gases. ASTM D6348-12 has been used instead of USEPA Method 320.

2014 ISMI Environmental Characterization Guideline (SEMICONDUCTOR INDUSTRY) The ISMI Guideline for Environmental Characterization of Semiconductor Process Equipment – Revision 3 was published in 2014. First published in 2001 and revised in 2006, 2009 and 2014. This document provides guidance to device manufacturers and equipment suppliers on how to characterize air emissions including gaseous and particulates/powders, liquid effluents and solid wastes of their tools and processes.

2014 ISMI GUIDELINE ANALYTICAL METHODS Protocols are provided for the analytical methods recommended for collecting the data Quadrupole mass spectrometry (QMS) FTIR Fluorine gas analysis based on chemiluminescence Additional analytical methods can be used if acceptable by regulatory agency and recognizable accreditation.

EPA FLUORINATED GREENHOUSE GAS TESTING PROTOCOL EPA published in March 2010 the Protocol for Measuring Destruction or Removal Efficiency (DRE) of Fluorinated Greenhouse Gas Abatement Equipment in Electronics Manufacturing, Version 1. The purpose of the Protocol is to provide a practical and reliable method for measuring DREs of POU abatement systems for fluorinated greenhouse gases used during the manufacture of electronics products. Note: it should also be able to be used for nitrous oxide (N2O) and methane (CH4).

SAMPLING SCHEMATIC

40 CFR PART 98 SUBPART I APPENDIX A POINT-OF-USE (POU) ABATEMENT SYSTEM EFFLUENT VOLUMETRIC FLOW RATE Introduce the non-reactive, non-native gas used for determining total volume flow and dilution across the POU abatement device at a location in the exhaust of the POU abatement device. Can inject at POU abatement device inlet if no abatement DRE of non-reactive, non-native gas.

FLOW TRACER INJECTION DYNAMICS AT THE POU ABATEMENT SYSTEM EFFLUENT POU Effluent Flow Volumetric Flow Meter 0.5L MFC ~1’ SF6 Tracer Gas Main Header X FTIR or QMS Venturi Pump (~5 lpm) 5L Kr Tracer Gas

SAMPLE AND TRACER INJECTION LOCATION OF POU ABATEMENT SYSTEM #1 Extraction Location SF6 Tracer Injection Location

SAMPLE AND TRACER INJECTION LOCATION OF POU ABATEMENT SYSTEM #2 Extraction Location SF6 Tracer Injection Location

SAMPLE AND TRACER INJECTION LOCATION OF POU ABATEMENT SYSTEM #3 Extraction Location SF6 Tracer Injection Location

ADDITIONAL SAMPLING THOUGHTS (1 OF 2) Review the need to remove all filters, minimize metal and heat all lines/probes to FTIR if particles are part of what you are analyzing for (e.g., ammonia and hydrogen fluoride in presence of ammonium fluoride). FTIR needs to be 150°C or higher to measure certain dissociable compounds. Assess impact on FTIR equipment. Determine how to handle below detection limit data when averaging above detection limit data. How should test run data be averaged if all values are below detection limit. Good to consult with local regulatory agencies, even if not compliance test.

ADDITIONAL SAMPLING THOUGHTS (2 OF 2) Include a person knowledgeable in specific process emissions in and out of abatement device to review sampling methods to ensure best data. For example, other contaminants in stream sampled could be interferences with contaminants trying to be measured. FTIR data may need to be reprocessed by same test company or another test company if data appears to be technically unsound. Develop a detailed test plan even if not a compliance test.

SOME FTIR ADVANTAGES Easier and less expensive to use for multiple semiconductor process gases and byproducts (except mononuclear diatomics and inert gases). Does not need calibration as often as other instrumentation. Can reprocess data after the testing is done, including determining unknowns. FTIR method is approved by United States EPA for determining point-of-use abatement device effluent volumetric flow rate through 40 CFR Part 98 Subpart I.

SOME FTIR DISADVANTAGES Cannot be used for inert gases and mononuclear diatomics. Some compounds are difficult to quantify at low detection limits due to interferences from other compounds.

ADDITIONAL FTIR TESTING LESSONS LEARNED It is essential to provide for air leak checks for the entire sampling system, including analytical equipment. Air leaks have been found with fittings, in FTIR, etc. Nitrous oxide (N2O) concentrations, especially at POU abatement device inlet, can be very high and may not be linear with FTIR. This will provide inaccurate DRE results. A low-flow process pump purge (e.g., 15 lpm) could be sampled at 5 lpm, which would lead to 33% of POU inlet flow not being abated by POU abatement system.

Questions?

Contact Us Mike Sherer – msherer@trinityconsultants.com Trinity Phoenix 1661 E Camelback Road, Suite 290 Phoenix, AZ 85016 Phone: 602-274-2900 http://www.trinityconsultants.com/phoenix/

Stay Informed on Emerging Issues www.trinityconsultants.com Environmental Training and Online Registration Free Seminars/Webinars and Online Registration eNews – Federal and State Regulatory Updates Environmental Quarterly 27

Connect with Trinity http://www.linkedin.com/company/trinity-consultants http://www.facebook.com/TrinityConsults http://twitter.com/trinityconsults http://www.youtube.com/trinityconsultants