F I L T R A T I O N SCHOONOVER, INC..

Slides:



Advertisements
Similar presentations
Binks Spray Tips July 2010.
Advertisements

Larger Diameter Hymax® 14 – 24 Inches in Diameter
The Concept of the Basic Liquid
CHAPTER 45 Engine Lubrication.
1 Hydroflow Filtration Systems F I L T R A T I O N S Y S T E M S HYDROFLOW SURFACE FILTRATION Versus DEPTH FILTRATION In Metalworking Fluids  SURFACE.
SERVICING EVAPORATIVE
REMOVE AND INSTALL THERMOSTAT AND TEST OPERATION CS4 A.1 D.6 P-5/6.
Introduction to Septic Tanks John R. Buchanan, Ph.D., P.E. University of Tennessee.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Flange-lok Installation Instructions Quick Installation Guide rev. DB.
Motor Leveling MECH 1200 Soft foot Condition: One or more of the mounting feet is not level with the others. Nuts loosen, vibration, misalignment Metal.
ATLIER FRANCOIS (COMPRESSOR). MAINTENANCE AND CHECKS DAILY CHECKS DAILY CHECKS INSPECT AND NOTE THE OIL LEVEL AND ALL THE PRESSURE AND TEMPERATURE LEVELS(FILLL.
Trouble Shooting How to Recognize Improper Installation May 2009 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages Tubing.
Piston Engine Operations
Filtration.
"AIR COOLER" Heat Exchanger
Sunday, May 17, 2015 Pressure Booster Service. Sunday, May 17, 2015 Booster Service Basics Control Panel Components Setting a pressure switch Setting.
Proper Pump Installation Practices
Valves and Appurtenances
Step 1 Park vehicle on a level surface then engage the parking brake and turn off engine. If you cannot comfortably get under the car, raise the front.
CARBURETED FUEL SYSTEM
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Mechanical for Oil Heat
Plan 2 – Dead-end Seal Chamber Optional Jacket
Floating Head Heat Exchanger
INTRODUCTION Definition:
“Fix Tube Sheet” Heat Exchanger
THE HYDROFLOW STAR FILTER
Measuring Engine Components and Specifications
Unit A 6-3 Mechanical Systems and Technology. Problem Area 6 Agricultural Power Systems.
TRENTON Casing Filler Presentation
Binks Spray Tips November 2008 Surface Preparation - General Anything you don’t want to see in the final finish must be removed from the surface Surface.
Trouble Shooting How to Recognize Improper Installations January 2013 The Ford Meter Box Company, Inc. Table of Contents Valves and Corp StopsPages 1 -
Engine Reassembly Technicians need to take their time when reassembling an engine. This is not a race! Listen for instruction when to add the next piece.
Oil Pressure Testing.
Model 12 Intek Horizontal OHV
Lesson 3 Measurement Tools used in measuring engine components Micrometer caliper – precision measuring tool for taking outside measurements. Inside.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
Plating Cell Considerations/ Proper Cell Design,
Engineering II – August 2016
PNEUMATICS Chapter 5 Secondary Air Treatment
Air Pak Drying Systems Presented By: Dry Air Systems, Inc. Innovator of Unique Regenerative Desiccant Air Dryers For Compressed Air & Fluid Power Controls,
Intake & Exhaust Components
SPARKLER FILTRATION TRAINING SEMINAR
Filtration & Clarification
Automotive Engines Theory and Servicing
Bilge Pump Service Project Model Service Kit
MAGM 262 Hydraulic Seals Mr. Conrado.
Automotive Engines Theory and Servicing
EVAPORATIVE EMISSION CONTROL SYSTEMS
Welcome to the Amrit Filtration Equipments
SB Packing Automatic Downpuller Power Unit
Trouble Shooting Hydraulic System Failure
Vertical Pressure Filters
Troubleshooting 11/14/2018 Water King Service Seminar.
CHAPTER 45 Engine Lubrication.
Horizontal Installation Overview
Gaskets and Packing An introduction to Gaskets Packing
Floating Head Heat Exchanger
TRENTON Casing Filler Presentation
What to Expect When You’re Inspected
VG INSTALATION & MAINTENANCE.
Lubrication Systems Chapter 12 Page 149.
Chapter 6 Cyclones.
Servo Pilot SFP-150 to 1500.
Automotive Engines Theory and Servicing
Hydraulic Flow Control • Metering Fluid Flow
Presentation transcript:

F I L T R A T I O N SCHOONOVER, INC.

USING THE Sparkler HORIZONTAL PLATE FILTER SCHOONOVER, INC.

THIS HOUSES THE FILTER SYSTEM SCHOONOVER, INC.

THIS HOUSES THE FILTER SYSTEM FILTER MEDIA Paper Cloth Wire Mesh FILTER AID CAKE BUT THESE DO THE FILTERING SCHOONOVER, INC.

33-S-19 SPARKLER HORIZONTAL PLATE FILTER MODEL NUMBER INTERPETATION FILTER PLATE DIAMETER, INCHES FILTER PLATE TYPE NUMBER OF FILTER PLATES, EXCLUDING SCAVENGER PLATE XS = EXTRA SHALLOW, 1” S = SHALLOW, 1-1/2” D = DEEP, 2-1/2” HORIZONTAL PLATE FILTERS ARE AVAILABLE IN SCAVENGER AND NON-SCAVENGER DESIGNS ANY SPARKLER FILTER TANK WILL OPERATE WITH XS, S OR D PLATES SCHOONOVER, INC.

HORIZONTAL PLATE FILTER ASSEMBLING THE SPARKLER HORIZONTAL PLATE FILTER NON-SCAVENGER TYPE SCHOONOVER, INC.

NON-SCAVENGER HORIZONTAL PLATE FILTER COVER SWING BOLT NUT CENTER TIE ROD COMPRESSION CAP DAVIT PLATE BUNDLE OUTLET GASKET SWING BOLT COVER GASKET INLET TANK OUTLET TANK DRAIN TIE ROD SOCKET TIE ROD SOCKET GASKETS (2) SCHOONOVER, INC.

NON-SCAVENGER PLATE BUNDLE COMPONENTS CENTER TIE ROD SIDE TIE ROD COMPRESSION CAP TOP RING FILTER MEDIA DETAIL OF OUTLET GASKET FILTER PLATE BAFFLE ZONE BOTTOM RING OUTLET GASKET SCHOONOVER, INC.

HORIZONTAL NON-SCAVENGER FILTER, ASSEMBLY DETAIL COMPRESSION CAP TOP RING SIDE TIE ROD OUTLET GASKET TANK DRAIN CENTER TIE ROD TIE ROD SOCKET SCHOONOVER, INC.

SIDE TIE ROD DESIGNS TOP RING THREADED T- SLOT TIE ROD TIE ROD BOTTOM RING SCHOONOVER, INC.

HORIZONTAL PLATE FILTER ASSEMBLING THE SPARKLER HORIZONTAL PLATE FILTER SCAVENGER TYPE SCHOONOVER, INC.

SCAVENGER TYPE HORIZONTAL PLATE FILTER COVER SWING BOLT NUT CENTER TIE ROD COMPRESSION CAP DAVIT PLATE BUNDLE OUTLET GASKET SWING BOLT COVER GASKET INLET TANK OUTLET TANK DRAIN SCAVENGER OUTLET TIE ROD SOCKET TIE ROD SOCKET GASKETS (2) SCHOONOVER, INC.

SCAVENGER PLATE BUNDLE COMPONENTS CENTER TIE ROD SIDE TIE ROD COMPRESSION CAP TOP RING FILTER MEDIA DETAIL OF OUTLET GASKET FILTER PLATE BAFFLE ZONE SCAVENGER PLATE BOTTOM RING OUTLET GASKET SCHOONOVER, INC.

HORIZONTAL SCAVENGER FILTER, ASSEMBLY DETAIL COMPRESSION CAP TOP RING SIDE TIE ROD OUTLET GASKET TANK DRAIN CENTER TIE ROD TIE ROD SOCKET SCHOONOVER, INC.

HORIZONTAL PLATE CONSTRUCTION ALL PARTS AT PLATE BOTTOM 50, 65, 75 PSID SCREEN IS FLAT ACROSS PLATE CENTER CUP PERFORATED SCREEN PLATE RING DIMPLED PLATE BOTTOM ALL PARTS AT PLATE BOTTOM LAY ON ONE PLANE = SEALING SURFACE SCHOONOVER, INC.

ALL PARTS AT PLATE BOTTOM 100 PSID HORIZONTAL PLATE CONSTRUCTION SCREEN IS FLAT ACROSS PLATE CENTER CUP PERFORATED SCREEN UP & DOWN BAFFLE PLATE RING DIMPLED PLATE BOTTON BAFFLE SUPPORT ALL PARTS AT PLATE BOTTOM LAY ON ONE PLANE = SEALING SURFACE SCHOONOVER, INC.

FILTER MEDIA PLACEMENT CORRECTLY PLACED FOLDED FILTER PLATE OFF CENTER CRUMPLED SCHOONOVER, INC.

SLANTED AND/OR TOP ROTATED WITH RESPECT TO BOTTOM PLATE STACKING BAFFLE ZONE PLACE OPPOSITE INLET H L = L L > H CORRECT INCORRECT SLANTED AND/OR TOP ROTATED WITH RESPECT TO BOTTOM LOOSE TIE RODS SCHOONOVER, INC.

RECOMMENDED TORQUE VALUES TIE RODS Diameter, Inches 1/2 5/8 3/4 1 1-1/4 Torque, ft-lb 30 45 100 125 200 COVER SWING BOLTS Diameter, Inches 5/8 3/4 1 1-1/4 Torque, ft-lb 45 100 125 200 CROSS TIGHTEN AND CROSS LOOSEN SCHOONOVER, INC.

HOW DO YOU GET GOOD SEALS? PLACE THE MEDIA PROPERLY ON THE PLATE STACK PLATES CORRECTLY USE ALL THE TIE RODS TIGHTEN THE TIE RODS TO THE PROPER TORQUE USE THE CROSS TIGHTENING TECHNIQUE CHECK THE OUTLET GASKET EACH TIME YOU DRESS THE FILTER SCHOONOVER, INC.

THE ONLY SEALS BETWEEN THE FEED AND THE FILTRATE ARE: THE MEDIA (PAPER OR CLOTH) BETWEEN EACH PLATE THE OUTLET GASKET AT THE BOTTOM OF THE PLATE BUNDLE IF THESE SEALS ARE GOOD, AND YOU HAVE THE RIGHT MEDIA/FILTER AID COMBINATION, YOU WILL NOT PASS SOLIDS SCHOONOVER, INC.

OPTIONAL STEAM JACKETS CAPACITIES and LIMITS PRESSURES INLET DIFFERENTIAL (INLET-OUTLET) 50 PSID TANK 60 PSI STANDARD 18 GAUGE SCREENS = 50 PSID 16 GAUGE SCREENS = 65 PSID 14 GAUGE SCREENS = 75 PSID OPTIONAL STEAM JACKETS 14.5 TO 150 PSI OP OUTLET SCHOONOVER, INC.

HORIZONTAL PLATE FILTER SCAVENGER & NON-SCAVENGER TYPE OPERATING THE SPARKLER HORIZONTAL PLATE FILTER SCAVENGER & NON-SCAVENGER TYPE SCHOONOVER, INC.

TWO HORIZONTAL PLATE FILTER TYPES SCAVENGER TYPE NON-SCAVENGER TYPE INLET PRESSURE INLET PRESSURE OUTLET PRESSURE SCAVENGER OUTLET OUTLET PRESSURE INLET PIPING INLET PIPING TANK DRAIN TANK DRAIN OUTLET PIPING SCHOONOVER, INC.

TWO HORIZONTAL PLATE FILTER TYPES SCAVENGER TYPE NON-SCAVERGER TYPE FEED FEED SCHOONOVER, INC.

TWO HORIZONTAL PLATE FILTER TYPES SCAVENGER TYPE NON-SCAVERGER TYPE FEED FEED FILTRATE FILTRATE SCHOONOVER, INC.

HORIZONTAL PLATE FILTER, SCAVENGER TYPE FEED FILTRATE SCHOONOVER, INC.

HORIZONTAL PLATE FILTER, FILTRATION FLOW PATH PERFORATED PLATE SCREEN CAKE MEDIA FEED TANK FILTRATE SCHOONOVER, INC.

HORIZONTAL SCAVENGER PLATE FILTER, SCAVENGER DETAIL OUTLET GASKET SCAVENGER OUTLET OPEN CENTER TIE ROD MAIN OUTLET CLOSED TIE ROD SOCKET SCHOONOVER, INC.

HORIZONTAL NON-SCAVENGER FILTER, ASSEMBLY DETAIL OUTLET GASKET TANK DRAIN CENTER TIE ROD TIE ROD SOCKET SCHOONOVER, INC.

HORIZONTAL PLATE FILTER FILTERING WITH THE SPARKLER HORIZONTAL PLATE FILTER SCHOONOVER, INC.

HORIZONTAL PLATE FILTER, NON-SCAVENGER TYPE-Typical Piping GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK PRECOAT TANK FILTRATE OUT TANK DRAIN AND HEAL BLOWBACK OUTLET PRESSURE OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

HORIZONTAL PLATE FILTER, SCAVENGER TYPE-Typical Piping GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK SCAVENGER OUTLET PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

FILLING THE FILTER SCHOONOVER, INC. GAS INLET INLET PRESSURE VENT BODY FEED TANK PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

PRECOATING THE FILTER SCHOONOVER, INC. GAS INLET INLET PRESSURE VENT BODY FEED TANK PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

PRECOATING GUIDELINES PURPOSE: TO FORM A UNIFORM, THIN CAKE THAT PROTECTS THE MEDIA FROM BLINDING AND GIVES IMMEDIATE CLARITY AMOUNT OF FILTER AID FOR PRECOATING = 0.1 TO 0.2 POUNDS/SQ. FT. OF FILTER AREA PRECOAT RATE = 0.5 TO 1.5 GPM/SQ. FT. OF FILTER AREA PROCESS SOLIDS PRECOATING REQUIRES 0.1 TO 0.2 PERCENT SOLIDS CONCENTRATION SCHOONOVER, INC.

FILTERING (WITH BODY FEED) GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

PURPOSE: TO KEEP THE CAKE OPEN FOR MAXIMUM FLOW RATE AND CYCLE TIME BODYFEED GUIDELINES PURPOSE: TO KEEP THE CAKE OPEN FOR MAXIMUM FLOW RATE AND CYCLE TIME AMOUNT OF FILTER AID = 1:1 FILTER AID TO SOLIDS HIGHER RATIO FOR SLIMEY SOLIDS FILTER AID GRADE APPROXIMATES SIZE OF SOLID PARTICLE SIZE SCHOONOVER, INC.

BLOWDOWN SCHOONOVER, INC. GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK HEEL PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

HEEL FILTRATION WITH SCAVENGER PLATE GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK HEEL PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

FINAL BLOWDOWN AND CAKE DRYING GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

DISPLACEMENT WASH SCHOONOVER, INC. WASH GAS INLET INLET PRESSURE VENT FILTER INLET BODY FEED TANK HEEL PRECOAT TANK FILTRATE OUT OUTLET PRESSURE TANK DRAIN OUTLET FEED IN BODY FEED PUMP PUMP SCHOONOVER, INC.

HORIZONTAL PLATE FILTER SCAVENGER & NON-SCAVENGER TYPE TROUBLE SHOOTING THE SPARKLER HORIZONTAL PLATE FILTER SCAVENGER & NON-SCAVENGER TYPE SCHOONOVER, INC.

A LACK OF FILTRATE CLARITY IS GENERALLY DUE TO LEAKING SEALS THE ONLY SEALS EFFECTING CLARITY ARE: THE OUTLET GASKET THE OUTER RING AND CENTER HUB OF EACH PLATE LEAKS AT THESE SEALS ARE DUE TO ERRORS IN FILTER ASSEMBLY, IMPROPER MEDIA PLACEMENT, OR DAMAGED FILTER COMPONENTS. OTHER POSSIBLE CAUSES: WRONG FILTER AID WRONG MEDIA (FILTER PAPER) WRONG TIE ROD TORQUE WRONG PROCEDURES LEAKS AT THE COVER GASKET OR TIE ROD SOCKET GASKETS DO NOT EFFECT CLARITY SCHOONOVER, INC.

IF FILTRATE DOES NOT CLEAR IN 10 - 15 MINUTES CORRECTIVE ACTION CHECK OUTLET GASKET AT EACH FILTER CHANGE. CHECK THAT MEDIA IS PLACED PROPERLY ON EACH PLATE. CHECK CONDITION OF FILTER PLATES, SCREENS AND CUPS. CHECK TIE ROD TORQUE. CHECK THAT THE BAFFLE ON THE PLATES FACES THE INLET NOZZLE CHECK PROCEDURES FAST FILLING OF THE FILTER TANK CAN TEAR FILTER PAPER. FAST FILLING CAN BLIND UPPER FILTER PLATES AND RESULT IN POOR PRECOATING. SLOW PRECOATING CAN PRODUCE POOR PRECOAT DISTRIBUTION. IF FILTRATE DOES NOT CLEAR IN 10 - 15 MINUTES STOP YOU HAVE A PROBLEM ! SCHOONOVER, INC.

SIGNS OF TROUBLE BLEED THROUGH, CHECK PLATE RING, HUB AND CENTER CUP FOR DAMAGE. TEARS AROUND CENTER HOLE INDICATE FAST FILLING PROBLEM SCHOONOVER, INC.

SIGNS OF TROUBLE CAKE EROSION DUE TO UNALIGNED BAFFLE THIN CAKE TOWARD CENTER DUE TO SLOW FLOW SCHOONOVER, INC.

FILTER PLATE TOLERANCES ALL PARTS AT PLATE BOTTOM SCREEN IS FLAT ACROSS PLATE CENTER CUP PERFORATED SCREEN 0.020-0.025” PLATE RING DIMPLED PLATE BOTTOM 0.025-0.030” ALL PARTS AT PLATE BOTTOM LAY ON ONE PLANE SCHOONOVER, INC.

19 PLATES X 5.62 SQ FT / PLATE = 106.8 SQ FT CAPACITIES and LIMITS SURFACE AREA NO. of PLATES X 5.62 SQ FT / PLATE = FILTRATION AREA 19 PLATES X 5.62 SQ FT / PLATE = 106.8 SQ FT SURFACE AREA IS A FACTOR IN DETERMINING FLOW RATE - EXAMPLE: IF A PROCESS ALLOWS FILTERING AT 0.5 GPM /SQ FT, THE MAXIMUM FLOW RATE IS 0.5 GPM / SQ FT X 106.8 SQ FT =53GPM OTHER FACTORS THAT CONTROL FLOW RATE ARE: VISCOSITY, CAKE RESISTANCE AND PRESSURE. SCHOONOVER, INC.

19 PLATES X 5.62 SQ FT / PLATE X 3/4 INCH THICK CAKE = 6.67 CUBIC FEET HORIZONTAL PLATE FILTER, CAKE LOADING, SHALLOW PLATES CAKE THICKNESS = 1-3/4 INCH CAKE MEDIA 1/4 INCH GAP 1 INCH CAKE SPACE CAKE VOLUME 19 PLATES X 5.62 SQ FT / PLATE X 3/4 INCH THICK CAKE = 6.67 CUBIC FEET SCHOONOVER, INC.

TO ACHIEVE GOOD WASHING AND DRYING DON’T PACK THE PLATES TO ACHIEVE GOOD WASHING AND DRYING TO AVOID BRIDGING THAT DAMAGES PLATES TO MAKE CLEANING EASIER SCHOONOVER, INC.

THREE FILTRATION TECHNIQUES When you have - Crystalline, easily filtered solids Very low solids concentration Particle size about the same as media opening Use - Bag, cartridge, plate filters MEDIA ONLY SCHOONOVER, INC.

THREE FILTRATION TECHNIQUES When you have - Crystalline, easily filtered solids Very low solids concentration Particle size about the same as media opening Use - Bag, cartridge, plate filters MEDIA ONLY When you have - Non-slimy solids Up to 5% solids Need fine retention Use Cake Filtration- Plate filter MEDIA + PRECOAT SCHOONOVER, INC.

THREE FILTRATION TECHNIQUES When you have - Crystalline, easily filtered solids Very low solids concentration Particle size about the same as media opening Use - Bag, cartridge, plate filters MEDIA ONLY When you have - Non-slimy solids Up to 5% solids Need fine retention Use Cake Filtration- Plate filter MEDIA + PRECOAT When you have - Slimy, difficult to filter solids Up to 5% solids Need fine retention Use Cake Filtration - Plate filter MEDIA + PRECOAT BODY FEED SCHOONOVER, INC.