S.G. Giannissi1,2, I.C.Tolias1,2, A.G. Venetsanos1

Slides:



Advertisements
Similar presentations
CFD ANALYSIS OF CROSS FLOW AIR TO AIR TUBE TYPE HEAT EXCHANGER
Advertisements

Hongjie Zhang Purge gas flow impact on tritium permeation Integrated simulation on tritium permeation in the solid breeder unit FNST, August 18-20, 2009.
Gaseous And Particulate Dispersion In Street Canyons
OpenFOAM for Air Quality Ernst Meijer and Ivo Kalkman First Dutch OpenFOAM Seminar Delft, 4 november 2010.
Flammable extent of hydrogen jets close to surfaces Benjamin Angers*, Ahmed Hourri*, Luis Fernando Gomez, Pierre Bénard and Andrei Tchouvelev** * Hydrogen.
1 Validation of CFD Calculations Against Impinging Jet Experiments Prankul Middha and Olav R. Hansen, GexCon, Norway Joachim Grune, ProScience, Karlsruhe,
ICHS 4, San Francisco, California, USA, September 2011 Experimental study of the concentration build-up regimes in an enclosure without ventilation B.CARITEAU,
International Conference on Hydrogen Safety, Pisa, 8-10 September CFD modeling of large scale LH2 spills in open environment Dr. A.G Venetsanos.
CFD Modeling for Helium Releases in a Private Garage without Forced Ventilation Papanikolaou E. A. Venetsanos A. G. NCSR "DEMOKRITOS" Institute of Nuclear.
1 JRC – IE Pisa on CFD modelling of accidental hydrogen release from pipelines. H. Wilkening - D. Baraldi Int. Conf. on Hydrogen Safety Pisa Sept.
University of South Carolina FCR Laboratory Dept. of Chemical Engineering By W. K. Lee, S. Shimpalee, J. Glandt and J. W. Van Zee Fuel Cell Research Laboratory.
On numerical simulation of liquefied and gaseous hydrogen releases at large scales V. Molkov, D. Makarov, E. Prost 8-10 September 2005, Pisa, Italy First.
Natural and Forced Ventilation of Buoyant Gas Released in a Full-Scale Garage : Comparison of Model Predictions and Experimental Data Kuldeep Prasad, William.
Centre for Fire and Explosion Studies Numerical Study of Spontaneous Ignition of Pressurized Hydrogen Release through a length of tube with local contraction.
Analysis of Buoyancy-Driven Ventilation of Hydrogen from Buildings C. Dennis Barley, Keith Gawlik, Jim Ohi, Russell Hewett National Renewable Laboratory.
Pro-Science 4 th International Conference of Hydrogen Safety, September 12-14, 2011, SAN FRANCISCO, USA EXPERIMENTAL STUDY OF IGNITED UNSTEADY HYDROGEN.
Choking Pressure Ratio Guidelines for Small Critical Flow Venturis
ICHS4, San Francisco, September E. Papanikolaou, D. Baraldi Joint Research Centre - Institute for Energy and Transport
Hiromasa Nakayama*, Klara Jurcakova** and Haruyasu Nagai*
A Numerical / Analytical Model of Hydrogen Release and Mixing in Partially Confined Spaces Kuldeep Prasad, William Pitts and Jiann Yang Fire Research Division.
Large-Scale Hydrogen Release In An Isothermal Confined Area J.M. LACOME – Y. DAGBA – D. JAMOIS – L. PERRETTE- C. PROUST ICHS- San Sebastian, sept 2007.
Results of the HySafe CFD Validation Benchmark SBEPV5 T. Jordan 1, J.García 3, O. Hansen 4, A. Huser 7, S. Ledin 8, P. Middha 4, V. Molkov 5, J. Travis.
Page 1 SIMULATIONS OF HYDROGEN RELEASES FROM STORAGE TANKS: DISPERSION AND CONSEQUENCES OF IGNITION By Benjamin Angers 1, Ahmed Hourri 1 and Pierre Bénard.
4 th ICHS San Francisco, September 2011 Numerical Investigation of Subsonic Hydrogen Jet Release Boris Chernyavsky 1, Pierre Benard 1, Peter Oshkai.
Mitglied der Helmholtz-Gemeinschaft Simulation of the efficiency of hydrogen recombiners as safety devices Ernst-Arndt Reinecke, Stephan Kelm, Wilfried.
Mathematical Equations of CFD
Second International Conference on Hydrogen Safety, San Sebastian, Spain, September 2007 CFD for Regulations, Codes and Standards A.G. Venetsanos.
Preparing for the Hydrogen Economy by Using the Existing Natural Gas System as a Catalyst // Project Contract No.: SES6/CT/2004/ NATURALHY is an.
IESVic 1 QUANTITATIVE IMAGING OF MULTI-COMPONENT TURBULENT JETS Arash Ash Supervisors: Dr. Djilali Dr. Oshkai Institute for Integrated Energy Systems University.
HIGH PRESSURE HYDROGEN JETS IN THE PRESENCE OF A SURFACE P. Bénard, A. Tchouvelev, A. Hourri, Z. Chen and B. Angers.
STABLY STRATIFIED SHEAR-PRODUCED TURBULENCE AND LARGE-SCALE-WAVES IN A LID DRIVEN CAVITY BEN-GURION UNIVERSITY OF THE NEGEV FACULTY OF ENGINEERING SCIENCES.
Preparing for the Hydrogen Economy by Using the Existing Natural Gas System as a Catalyst // Project Contract No.: SES6/CT/2004/ NATURALHY is an.
Sheared stably stratified turbulence and
Modeling of hydrogen explosion on a pressure swing adsorption facility *B. Angers 1, A. Hourri 1, P. Benard 1 E. Demaël 2, S. Ruban 2, S. Jallais 2 1 Institut.
NATO ASI Conference, Kyiv MODELING AND SIMULATION OF TURBULENT PENETRATIVE CONVECTION AND POLLUTANT DISPERSION ABOVE THE URBAN HEAT ISLAND IN STABLY.
Consequence Analysis 2.2.
Mr. Nektarios Koutsourakis1,2 Dr. Alexander Venetsanos2
© GexCon AS JIP Meeting, May 2011, Bergen, Norway 1 Ichard M. 1, Hansen O.R. 1, Middha P. 1 and Willoughby D. 2 1 GexCon AS 2 HSL.
Turbulence Models Validation in a Ventilated Room by a Wall Jet Guangyu Cao Laboratory of Heating, Ventilating and Air-Conditioning,
Indian Institute of Space Science and Technology STUDY OF EFFECT OF GAS INJECTION OVER A TORPEDO ON FLOW-FIELD USING CFD.
Entropy generation transient analysis of a grassfire event through numerical simulation E. Guelpa V. VERDA (IEEES-9), May 14-17, 2017, Split, Croatia.
ICHS 2015 – Yokohama, Japan | ID195
SIMULATION ANALYSIS ON THE RISK OF HYDROGEN
Tsinghua University, Beijing, China
Venting deflagrations of local hydrogen-air mixture
6th International Conference of Hydrogen Safety
International Topical Meeting on Nuclear Reactor Thermal Hydraulics
MODELING OF CRYOGENIC HYDROGEN JETS
ICHS 2015 – Yokohama, Japan | ID October, 20th
V. Shentsov, M. Kuznetsov, V. Molkov
Audrey DUCLOS1, C. Proust2,3, J. Daubech2, and F. Verbecke1
HOMOGENEOUS HYDROGEN DEFLAGRATIONS IN SMALL SCALE ENCLOSURE
S.G. Giannissi1 and A.G. Venetsanos1
IA-HySafe Standard benchmark exercise SBEP-V21: Hydrogen release and accumulation within a non-ventilated ambient pressure garage at low release rates.
Gilles Bernard-Michel
Anubhav Sinha, Vendra Chandra and Jennifer X. Wen
Chapter 8 : Natural Convection
SOME ISSUES CONCERNING THE CFD MODELLING OF CONFINED HYDROGEN RELEASES
Modeling and Analysis of a Hydrogen Release in a Large Scale Facility
Les Shirvill1, Mark Royle2 and Terry Roberts2 1Shell Global Solutions
Non-monotonic overpressure vs
CFD MODELING OF LH2 DISPERSION USING THE ADREA-HF CODE
E. Papanikolaou, D. Baraldi
Natural and Forced Ventilation of Buoyant Gas Released in a Full-Scale Garage : Comparison of Model Predictions and Experimental Data Kuldeep Prasad, William.
Thermal behavior of the LHCb PS VFE Board
ICHS5 – 2013 September, Brussels, Belgium | ID161
CFD computations of liquid hydrogen releases
Wind Velocity One of the effects of wind speed is to dilute continuously released pollutants at the point of emission. Whether a source is at the surface.
Forced Convection Trials at 100°C Natural Convection Trials at 100°C
Gilles Bernard-Michel (CEA)
Presentation transcript:

Removing the disrupting wind effect in single-vented enclosure exposed to external wind S.G. Giannissi1,2, I.C.Tolias1,2, A.G. Venetsanos1 1Environmental Research Laboratory, National Centre for Scientific Research Demokritos, Aghia Paraskevi, Athens, 15310, Greece, sgiannissi@ipta.demokritos.gr, venets@ipta.demokritos.gr 2School of Chemical Engineering, National Technical University of Athens, Heroon Polytechniou 9, 15780, Athens, Greece,

Scope of the study Hydrogen is flammable. Therefore, an accidental release inside confined spaces can form a flammable cloud. Passive ventilation is a common mitigation practice for reducing the gas concentration inside an enclosure. In single vented enclosure bidirectional flow occurs through the vent with hydrogen escaping through the upper part of the enclosure. Previous work1 has shown that wind blowing onto the opposite side of the vent in a single-vented facility hinders the exchange flow through the vent and more hydrogen is accumulated inside the enclosure. This is attributed to the turbulent eddies formed around the vent and block the bidirectional flow. This wind disrupting effect is studied here and several flow deflectors around the vent are investigated to eliminate this effect. 1 Giannissi, S.G., Hoyes, J.R., Chernyavskiy, B., Hooker, P. and J. Hall (2015). CFD benchmark on hydrogen release and dispersion in a ventilated enclosure : passive ventilation and the role of an external wind, Int. J. Hydrogen Energy, 40, pp. 6465-6477 21 Oct. 2015

Geometry and conditions Facility, release and wind conditions The facility is the GAMELAN facility2. Injection rate: 60 NL/min, injection point: 21 mm above ground, nozzle diameter: 20 mm, temperature: 26oC. Helium is released (for safety reasons). No external wind. This experiment is already simulated by Giannissi et al.3 and showed good agreement with the experiment. Therefore, it is considered trustworthy to use only simulations for the analysis. 2 Cariteau, B. and Tkatschenko, I., (2013). Experimental study of the effects of vent geometry on the dispersion of a buoyant gas in a small enclosure, Int. J. Hydrogen Energy, 38, No. 19, pp. 8030–8038 3 Giannissi, S.G., Shentsov, V., Melideo, D., Cariteau, B., Baraldi, D., Venetsanos, A.G. and Molkov, V. (2015). CFD benchmark on hydrogen release and dispersion in confined, naturally ventilated space with one vent, Int. J. Hydrogen Energy, 40, No. 5, pp. 2415-2429. 21 Oct. 2015

Geometry and conditions Facility, release and wind conditions The same facility and release conditions used for the present analysis imposing hypothetical external wind. 1.8 m/s at 3 m height (weak wind) 3.6 m/s at 3 m height (strong wind) 21 Oct. 2015

Geometry and conditions Description of the flow deflectors 5 different flow deflectors were tested to eliminate the wind disrupting effect and assist the bidirectional flow (only with weak wind) A. up plate B. down plate C. vertical plate D. middle plate E. complex 21 Oct. 2015

Modeling approach The CFD code ADREA-HF is used. The transient, 3D conservation equations for the mixture (mass, momentum, helium mass fraction). Isothermal conditions K-epsilon turbulence model with extra buoyancy terms 1st order fully implicit scheme for the time integration MUSCL scheme (2nd order) for the convective terms Central differences scheme for the diffusive terms. CFL=10 for the time step control (~0.025 sec and 0.013 sec for the simualtions with wak and strong wind respectevely) 21 Oct. 2015

Modeling approach Domain is extended only downwind the vent wall in the cases without wind, whereas the domain is extended at all directions around the facility in the case with wind. Symmetry assumption along y-axis. Source is modeled as a solid surface, on which the helium inlet conditions (velocity etc.) are imposed. 4 cells placed along the source diameter. Refinement near the source, the walls, the ceiling and the vent (maximum expansion ratio 1.12). 21 Oct. 2015

Results Replication of the wind disrupting effect No wind Weak wind 21 Oct. 2015

Results Eliminating the effect (weak wind) A. up plate D. middle plate Optimal flow deflector for practical considerations B. down plate E. complex C. vertical plate 21 Oct. 2015

Results Eliminating the effect (weak wind) 21 Oct. 2015

Results Eliminating the effect (weak wind) middle plate 21 Oct. 2015

Conclusions (1/2) The wind disrupting effect is reproduced: wind blowing onto the opposite side of the vent in single-vented facility opposes passive ventilation. This behavior is due to the turbulent eddies that are formed around the vent and hinder the hydrogen to flow out through the upper part of the vent and the fresh air to flow in through the lower part of the vent (bidirectional flow). The stronger the wind the higher the effect is. Flammable mass inside the enclosure is more than doubled when wind is blowing compared to the case without wind. 21 Oct. 2015

Conclusions (2/2) 5 flow deflectors around the vent were tested to eliminate the wind disrupting effect, up plate, down plate, vertical plate, middle plate, and both middle and vertical plate (complex). Only the middle plate and the complex layout assist the bidirectional flow. With these geometrical configurations both flammable and total mass of hydrogen inside the enclosure are lower compared to the case without any deflector. Small differences are observed between the results with these two flow deflectors with the complex one to be best. These vent configurations predict lower concentrations level even with the case without wind. Consequently, if the facility is equipped with these flow deflectors wind blowing windward the facility is now desired. However, for practical reasons the simpler flow deflector (middle plate) is proposed here. 21 Oct. 2015

Future work The performance of the proposed flow deflector can be tested imposing several release flow rates and using different vent sizes. Publications S.G. Giannissi, I.C. Tolias, A.G. Venetsanos (2015). Mitigation of buoyant gas releases in single-vented enclosure exposed to external wind: removing the disrupting wind effect, Int. Journal of Hydrogen Energy, under review. Strong wind also examined with the flow deflectors. A size parameterization of the proposed flow deflector is included. 21 Oct. 2015

Thank you very much for your attention Any Questions? The study was performed within the HyIndoor project. The authors would also like to acknowledge the H2FC project. H2FC European Infrastructure