Cross Connection Survey Training

Slides:



Advertisements
Similar presentations
Let’s watch a DVD… DVD Instructor Notes
Advertisements

City of Milwaukee Cross Connection Program Construction Trades Division Cross Connection Section.
East Carolina University Compressed Gas Safety Training Program
Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
Occupational Safety and Health Course for Healthcare Professionals.
4/23/2015 P.E.S.A.W.(public employees safe at work) 1 Safety Webinar: Hazard Communication and “Your Right to Know” Sponsored by the Georgia Department.
North Carolina Department of Agriculture and Consumer Services Pesticide Section Food & Drug Protection Division.
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Laboratory Fume Hoods In accordance with Title 8 CCR Section , Ventilation Requirements for Laboratory-Type Hood Operations. California State University.
North Carolina Child Care Licensing 2.01 Notes. Critical Questions Journal Question: Why does NC require licensing of child care centers?
ECE II Objective 2.01 Interpret licensing requirements for early childhood programs.
OSHA’s Respiratory Protection Standard 29 CFR
Backflow Training Introduction to Backflow For Irrigation Systems.
1 OSHA FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) OF 1970 George Mason University College of Nursing and Health Science Regulatory Requirements.
MassDEP, Environmental Analyst
Bulk Fertilizer Regulations For Farm Facilities Ohio Department of Agriculture Pesticide & Fertilizer Section 8995 East Main Street Reynoldsburg, Ohio.
AL/MS AWWA Effective Backflow Prevention August 26, 2013 Sam McElroy, PE Civil Services, LLC (256)
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
External Defibrillators: Recalls, Inspections, and the Quality System Regulation Melissa Torres Office of Compliance December 15, 2010.
SDWA1 The Safe Drinking Water Act (SDWA) The Safe Drinking Water Act (SDWA)
OSHA Long Term Care Worker Protection Program.  Recognize the purpose of the hazard communication standard.  Describe the components of a hazard communication.
Seafood HACCP Alliance for Training and Education Chapter 10 Principle 6: Establish Verification Procedures.
Presented by Dwain Butler District Director of Environmental Health Southeast Health District Waycross, Georgia.
QUALITY MANAGEMENT SYSTEM ACCORDING TO ISO
Implementing Rain Water Harvesting into Building Construction in VA Presented by: Guy Tomberlin, CBO Code Specialist III Fairfax County DPWES, Land Development.
Hazard Identification
CONTROL OF HAZARDOUS ENERGY LOCKOUT/ TAGOUT PROGRAM.
NFPA 31 Standard for the installation of Oil- Burning Equipment
Construction and Demolition Inert Processing Operations Compliance First: Evaluation of Solid Waste Facilities’ State Standards Training Provided By: California.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Drinking Water + Compressed Air = Dangerous Mixture Spokane Regional Cross Connection Control Chapter Requirements for Winterizing Irrigation Systems with.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
Proposed Rule for Preventive Controls for Animal Food.
Proposed Rule: 21 CFR 507 Proposed Rule for Preventive Controls for Animal Food 1.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
1 1 Poultry Slaughter Exemptions Under the Federal Poultry Products Inspection Act and the SC Poultry Products Inspection Law SC Poultry Products Inspection.
Exit Routes and Fire Protection
Ideapreneurship-universal entertainment paradise.
Checking and Corrective Action EPA Regions 9 & 10 and The Federal Network for Sustainability 2005.
Backflow Installation Public Meeting October 20, 2010.
ISO 9001:2015 Subject: Quality Management System Clause 8 - Operation
JLAB Pressure Systems Considerations Ed Daly. Outline Introduction Federal Law - 10CFR851 Compliance JLAB Pressure Systems Program –Complies with 10CFR851,
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Firefighter Emergency Escape Systems New York State Department of Labor Public Employee Safety and Health (PESH)
Lithuanian Water Suppliers Association LEGAL REGULATION OF WASTEWATER DISPOSAL AND TREATMENT IN LITHUANIA.
Timing (minutes) Learning ObjectiveMain tasks / ProcessResources / tools 5TitleStandard Operating Procedures for Power Press Machine Slide 1 5Index 
Flammable Liquids Directorate of Training and Education
Draft Revised Ordinance Cross Connection Control and Backflow Prevention March 27, 2015 Sun City Center.
Cooling Tower Audit Nathan Maple City of Marion. Why do we undertake an audit and sampling? Regulation 15 South Australian Public Health (Legionella)
- HEMIC Facility Inspections. Common Losses A fire breaks out in a 16 story office building An employee had the tips of two fingers amputated Could these.
 171 Public wells sampled in 2014  Bacteria and Nitrate samples taken  38 wells inspected (Surveyed)  1 nitrite sample taken.
CROSS CONNECTION CONTROL PROGRAM
National Food Control Systems
Workshop developed by RCAP/AWWA and funded by the USEPA
Backflow Prevention and Cross Connection Control Update
SAFE WORK INSTRUCTIONS
Your Public Water System’s Cross-Connection Control Program
Respiratory Protection Training
GTEC 2017 Annual UST Management & Compliance Assistance Seminar
4.5 Checking and Corrective Action Monitoring and Measurement
First Break To establish minimum safety requirements when performing a first break “First Break” – Refers to the initial opening of piping/equipment.
East Carolina University Compressed Gas Safety Training Program
Prerequisite Programs
Backflow Devices 5 Types.
Final Rule on Foreign Supplier Verification Programs
CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION
California State University Fresno
Presentation transcript:

Cross Connection Survey Training Cheryl Sandoval Drinking Water Protection Services Monterey County Health Department

Cross Connection Control Program Title 17 California Code of Regulations, Sections 7583-7605 http://www.cdph.ca.gov/certlic/drinkingwater/Documents/Lawbook/dwregulations-06-09-2010.pdf Requires the water supplier to protect the public water supply from contamination by implementation of a cross-connection control program.

Program Elements Program shall include following elements The adoption of operating rules or ordinances to implement the cross-connection program The conducting of surveys to identify water user premises where cross-connections are likely to occur The provisions of backflow protection by the water user at the user's connection or within the user's premises or both

Program Elements, cont The provision of at least one person trained in cross-connection control to carry out the cross-connection program The establishment of a procedure or system for testing backflow preventers The maintenance of records of locations, tests, and repairs of backflow preventers

Cross Connection Survey The water supplier shall evaluate the degree of potential health hazard to the public water supply which may be created as a result of conditions existing on a user's premises. The water supplier is not responsible for abatement of cross-connections which may exist within a user's premises. As a minimum, the evaluation should consider: The existence of cross connections The nature of materials handled on the property The probability of a backflow occurring The degree of piping system complexity The potential for piping system modification

Cross Connection Survey, cont Special consideration shall be given to the premises of the following types of water users Premises where substances harmful to health are handled under pressure in a manner which could permit their entry into the public water system. This includes chemical or biological process waters and water from public water supplies which have deteriorated in sanitary quality. Premises having an auxiliary water supply, unless the auxiliary supply is accepted as an additional source by the water supplier and is approved by the health agency

Cross Connection Survey, cont Special considerations, cont. Premises that have internal cross-connections that are not abated to the satisfaction of the water supplier or the health agency Premises where cross-connections are likely to occur and entry is restricted so that cross connection inspections cannot be made with sufficient frequency or at sufficiently short notice to assure that cross-connections do not exist Premises having a repeated history of cross-connections being established or reestablished

Type of Protection Required The type of protection shall be commensurate with the degree of hazard that exists on the consumer's premises Type of protective device that may be required (listed in an increasing level of protection) includes Double check Valve Assembly-(DC) Reduced Pressure Principle Backflow Prevention Device-(RP) Air gap Separation-(AG) The water user may choose a higher level of protection than required by the water supplier The minimum types of backflow protection are given in Table 1 Situations not covered in Table 1 shall be evaluated on a case-by-case basis and the appropriate backflow protection shall be determined by the water supplier or health agency

Type of Protection Required Table 1, Title 17, lists degrees of hazards and minimum protection required for Sewage and Hazardous Substances Auxiliary Water Supplies Recycled Water Fire Protection Systems Dockside Watering Points and Marine Facilities Premises where entry is restricted so that inspections for cross-connections cannot be made with sufficient frequency or at sufficiently short notice to assure that do not exist Premises where there is a repeated history of cross-connections being established or re-established

Examples of Required Protection Premises where there are irrigation systems into which fertilizers, herbicides, or pesticides are, or can be, injected RP Premises where there is an unapproved auxiliary water supply which is interconnected with the public water system AG - RP or DC may be provided in lieu of an AG if approved by the health agency and water supplier Premises where there is an unapproved auxiliary water supply and there are no interconnections with the public water system. RP - DC may be provided in lieu of a RP if approved by the health agency and water supplier.

Backflow Preventers Backflow preventers shall have passed laboratory and field evaluation tests performed by a recognized testing organization which has demonstrated their competency to perform such tests to the Department.

Location of Backflow Preventers Air-gap Separation. An air-gap separation shall be located as close as practical to the user's connection and all piping between the user's connection and the receiving tank shall be entirely visible unless otherwise approved in writing by the water supplier and the health agency Double Check Valve Assembly. A double check valve assembly shall be located as close as practical to the user's connection and shall be installed above grade, if possible, and in a manner where it is readily accessible for testing and maintenance Reduced Pressure Principle Backflow Prevention Device. A reduced pressure principle backflow prevention device shall be located as close as practical to the user's connection and shall be installed a minimum of twelve inches (12") above grade and not more than thirty-six inches (36") above grade measured from the bottom of the device and with a minimum of twelve inches (12") side clearance.

Testing and Maintenance of Backflow Preventers The water supplier shall assure that adequate maintenance and periodic testing are provided by the water user to ensure their proper operation Backflow preventers shall be tested by persons who have demonstrated their competency in testing of these devices to the water supplier or health agency. Backflow preventers shall be tested at least annually or more frequently if determined to be necessary by the health agency or water supplier. When devices are found to be defective, they shall be repaired or replaced in accordance with Title 17

Testing and Maintenance of Backflow Preventers, cont Backflow preventers shall be tested immediately after they are installed, relocated or repaired and not placed in service unless they are functioning as required The water supplier shall notify the water user when testing of backflow preventers is needed. The notice shall contain the date when the test must be completed Reports of testing and maintenance shall be maintained by the water supplier for a minimum of three years.

Any Questions? Cheryl Sandoval sandovalcl@co.monterey.ca.us http://www.co.monterey.ca.us/health/EnvironmentalHealth/WaterProt/crossConnection.htm