EUROTeV Diagnostics WP5

Slides:



Advertisements
Similar presentations
Bunch shape monitor for Linac-4 A.V.Feschenko Institute For Nuclear Research (INR), Moscow , Russia.
Advertisements

Measurements on phase stability at CTF3 Giulio Morpurgo / CERN IWLC 2010.
Damping ring K. Ohmi LC Layout Single tunnel Circumference 6.7 km Energy 5 GeV 2 km 35 km.
Linac4 BPM and Phase Pickup L. Søby08/ LINAC4 Beam Position, Phase and intensity Pick-ups.
BPS Location in CTF3/CLEX Area Mechanics with PCB Electronics Test Results BPS Linearity Error A linear fit of the wire test measures was done (left) for.
Front-end amplifiers for the beam phase loops in the CERN PS Alessandro Meoli (CERN BE/RF/FB) Supervised by Heiko Damerau 21 April CERN.
CLIC DR EXTRACTION KICKER DESIGN, MANUFACTURING AND EXPERIMENTAL PROGRAM C. Belver-Aguilar (IFIC) On behalf of: A. Faus-Golfe (IFIC), F. Toral (CIEMAT),
CIEMAT ACTIVITIES ON STRIPLINE KICKERS I. Rodríguez.
New Electron Beam Test Facility EBTF at Daresbury Laboratory B.L. Militsyn on behalf of the ASTeC team Accelerator Science and Technology Centre Science.
1 Plans for KEK/ATF 1. Introduction 2. Related Instrumentations at ATF 3. Experimental Plans for Fast Kicker R&D at ATF Junji Urakawa (KEK) at ILC Damping.
European Plans for ATF2 G.A. Blair LCPAC, KEK 24 th March 2006 Overview CERN + LAPP EUROTeV UK France DESY.
Status of the Fermilab Cold BPM R&D Manfred Wendt Fermilab 10/1/20091LCWA09 Main Linac WG.
CTF3 BPMs October 18-22/2010 IWLC2010 CTF3 BPMs Lars Soby 1.
1 C. Simon CLIC Instrumentation workshop BPM C. Simon on behalf of the Saclay’s group CLIC Instrumentation workshop 2 nd - 3 rd June.
Cavity Beam Position Monitor (BPM) for future linear colliders such as CLIC. N Joshi, S Boogert, A Lyapin, et al. Royal.
CLIC meeting 09/ Lars Søby, CERN AB/BDI1 PBPM: Precision Beam Position Monitor. WBCM: Wide Band Current Monitor. EUROTeV Diagnostics WP5
M.Gasior, CERN-BE-BI8th DITANET Topical Workshop on Beam Position Monitors, January 2012, CERN 1 BPM Signal Processing with Diode Detectors Marek.
Kévin Pepitone 1CLIC project meeting, CERN, December 1st, 2015 Kevin PEPITONE, BE-RF Drive Beam Injector Gun.
Collimator BPM electronics – Results from the lab, SPS and LHC
1 H. Hayano for the ATF collaboration Low Emittance Beam Generation in ATF H. Hayano for the ATF collaboration BPM electronics improvement emittance tuning.
CLIC09 Workshop October 2009Drive beam BPM’sLars Søby 1 Drive Beam BPM’s CLIC 09 work shop, CERN, of October 2009, Lars Søby.
BEPCII Transverse Feedback System Yue Junhui Beam Instrumentation Group IHEP , Beijing.
State Scientific Center of Russian Federation Institute for Theoretical and Experimental Physics ( ITEP )
1 EuroTeV High Bandwidth Wall Current Monitor Alessandro D’Elia CERN- Geneve.
BEPC II TIMING SYSTEM EPICS Seminar Presented by Ma zhenhan IHEP 20.August 2002.
1 EuroTeV High Bandwidth Wall Current Monitor Alessandro D’Elia AB-BI-PI.
An Inductive Pick-Up (IPU) for Beam Position and Current Measurement
P I T Z Photo Injector Test Facility Zeuthen Design consideration of the RF deflector to optimize the photo injector at PITZ S.Korepanov.
Fermilab BPM R&D Activities Nikolay Solyak, Manfred Wendt Fermilab Nicolas Chritin, Lars Soby CERN Nobuhiro Terunuma, Junji Urakawa KEK March 26-30, 20101LCWS10.
The Introduction to CSNS Accelerators Oct. 5, 2010 Sheng Wang AP group, Accelerator Centre,IHEP, CAS.
Diagnostics Workpackage G A Blair EUROTeV Final Meeting, DESY, Hamburg 30 th January 2009 Tasks Summary.
A. Faus-Golfe, J.V. Civera, C. Blanch and J.J. García-Garrigós whit the help of the CTF3 Collaboration 1 CTF3 meeting Jan-09.
S. Bettoni, R. Corsini, A. Vivoli (CERN) CLIC drive beam injector design.
1 Experiments with pulse supplies and strip-lines at ATF, Plans for fast extraction kicker for ATF2 1. Fast Kicker R&D at ATF 2. Instrumentation at ATF.
Emittance reduction by a SC wiggler in the ATF-DR September 16 th, 2009 Yannis PAPAPHILIPPOU and Rogelio TOMAS ATF2 weekly meeting.
Improvements to the LHC DCCT system P. Odier, C. Barschel, J.-J. Gras, L. Jensen, J. Longo, M. Ludwig, S. Thoulet P.Odier BI day /18.
INFN- Legnaro National Lab. Activity on ESS DTL Diagnostics: BPM & BCM
Kévin Pepitone 1CLIC workshop, CERN, January 2016 Kevin PEPITONE, BE-RF LEETCHI: Drive Beam Electron Source.
CLIC Drive beam BPM Requirements and cost estimate.
CLIC Beam instrumentation work shop, CERN, 2 nd & 3 rd of June 2009, Lars Søby BPM overview CLIC instrumentation work shop 2-3 June BPM overview.
1CEA/ Saclay/ SACM CARE/SRF/WP11 Development of a new Beam Position Monitor for FLASH, XFEL and ILC Cryomodules Claire Simon, Michel Luong, Stéphane Chel,
CLIC Workshop 18 th -22 nd January 2016, CERN 1 Alfonso Benot Morell Manfred Wendt.
CLIC Parameter Working Group Two Beam Module Design
BPM design Introduction BPM types Bench measurements
Phase Feed-Forward Piotr Skowroński (CERN)
High efficiency work and MBK development for accelerators
CAVITY BPM FOR CALIFES Claire Simon, Michel Luong, D. Bogard, P
Spectral methods for measurement of longitudinal beam profile
Wakefield & Cavity based Monitors: Fermilab BPM Development Plans
Status of the CLIC main beam injectors
CLIC Damping ring beam transfer systems
BCTW calibration status and future
F.Marcellini, D.Alesini, A.Ghigo
OTR based measurements for ELI-NP Gamma Beam Source
Need for Alignment Position of off-momentum proton w.r.t. beam
Measurements, ideas, curiosities
Junji Urakawa (KEK) for ATF International Collaboration
CEPC RF Power Sources System
CLIC DR EXTRACTION KICKER DESIGN, MANUFACTURE AND EXPERIMENTAL PROGRAM
Proton Beam Diagnostics
MCP Electronics Time resolution, costs
Beam Current Monitoring with ICT and BPM Electronics
Status of CTC activities for the Damping rings
Explanation of the Basic Principles and Goals
Physics Design on Injector I
JLEIC electron injection demo
CLIC Feasibility Demonstration at CTF3
JLEIC electron injection demo
Breakout Session SC3 – Undulator
HL-LHC HEL BPM.
Presentation transcript:

EUROTeV Diagnostics WP5 CAVBPM: Precision BPM. WBCM: Wide band current monitor. EUROTeV June 22 2005 Lars Søby, CERN AB

PBPM- deliverables Prototype PBPM: Report on bench tests: Design and build prototype. Report on bench tests: Design and build high resolution (100nm), mechanical stable test bench. Develop front end electronics. Measure PBPM. Report on beam tests: Build 3 PBPMs with separate supports and test with CTF3 beam. EUROTeV June 22 2005 Lars Søby, CERN AB

PBPM-Requirements Aperture: 4mm Resolution: 100nm Absolute precision: 10μm Rise time: <15ns EUROTeV  Dynamic range: ±1.5mm (15 bits) Linearity error: < 1% 24H stability: 1μm Vibrations <100nm Low frequency cutoff: 100kHz High frequency cutoff: 30MHz Bake out temperature: 150C Operating temperature: ~20C Vacuum: 10-9 Torr ME  EUROTeV June 22 2005 Lars Søby, CERN AB

PBPM-beam parameters ILC CLIC Repetition rate 5Hz 150Hz Beam pulse length 950μs 58ns Bunch spacing 337ns 267ps Bunch length 1ps 0.1ps Charges per bunch 2E10 2.5E9 Nb of bunches 2820 220 Peak current (LP 30MHz) 3220A (0.3A) 4023A Mean current per pulse 9.5mA 1.5A For CLIC the BPM’s are foreseen for the main Linac, with minimum one BPM per quadrupole i.e. 2600 BPM’s. We need additional BPM’s for the accelerating structures which could bring the number up to 20000. EUROTeV June 22 2005 Lars Søby, CERN AB

WCM as a BPM The image current distribution on the circumference reflects the beam position. Intensity signal () = All resistor are voltages summed. Position dependent signal () = voltages from opposite resistors are subtracted. EUROTeV June 22 2005 Lars Søby, CERN AB

Inductive Pick-Up Electrodes are combined in pairs so that each transformer sees half of the load Frequency low cut-offs are limited by connection parasitic resistances and primary electrode inductance. Design: M. Gasior EUROTeV June 22 2005 Lars Søby, CERN AB

Inductive Pick-Up This is what we want to do!! EUROTeV June 22 2005 Lars Søby, CERN AB

PBPM Low sensitivity to beam spray, halo. Independent on bunch spacing. Low longitudinal impedance. Low frequency FE electronics, could be passive  cheap. Sensitivity OK. Complicated design. Mechanical stability in 100nm range?. EUROTeV June 22 2005 Lars Søby, CERN AB

PBPM Fellow hired from September 2005. L. Søby working 5% in 2005 and 25% in 2006 and 2007 EUROTeV June 22 2005 Lars Søby, CERN AB

EUROTeV Diagnostics WP5 WBCM: Wide band current monitor. EUROTeV June 22 2005 Lars Søby, CERN AB

WBCM- deliverables Report on BW limits: Improved prototype system: 3D EM simulations to identify high frequency limits. Improved prototype system: Modify design and simulate. Build new WCM and test on bench. Report on beam tests: Tests with CTF3 beam EUROTeV June 22 2005 Lars Søby, CERN AB

WBCM-Requirements Beam current monitor with > 20GHz band width for measurement of intensity and bunch to bunch longitudinal position. Main beams, drive beams and damping rings. EUROTeV  Low frequency cutoff: 100kHz Bake out temperature: 150C Operating temperature: 20C Vacuum: 10-9 Torr 100kHz-20GHz WB signal transmission over 10-20m. ME  EUROTeV June 22 2005 Lars Søby, CERN AB

WCM Design: J. Durand, P. Odier EUROTeV June 22 2005 Lars Søby, CERN AB

WCM EUROTeV June 22 2005 Lars Søby, CERN AB

WCM Impedance 4 W Lf cut-off, direct output 250 kHz Lf cut-off, integrator output 10 kHz Hf cut-off 7 GHz Number of feed thru 8 Gap length 2 mm Beam aperture diameter 40 mm Length 256 mm Flange type DN63CF Max temp. bake-out 150 ºC EUROTeV June 22 2005 Lars Søby, CERN AB

WCM EUROTeV June 22 2005 Lars Søby, CERN AB

WBCM Scientific associate hired from January 2006. L. Søby working 5% in 2005, 25% in 2006 and 2007 EUROTeV June 22 2005 Lars Søby, CERN AB

Thank you for your attention EUROTeV WP5 Thank you for your attention EUROTeV June 22 2005 Lars Søby, CERN AB