Tek-CARE ® 500 Wireless Emergency Call System

Slides:



Advertisements
Similar presentations
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Advertisements

Welcome to the Radionet Monitoring Secure-Com Presentation.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
AIM Armstrong’s Intelligent Monitoring Training presentation.
Utility Management Providence Health System - Oregon Environment of Care.
Tek-CARE ® 500 Wireless Emergency Call System Brought to you by:
Mark Heggli Consultant to the World Bank Expert Real-time Hydrology Information Systems Workshop Module 4: Data Management Solutions for a Modernized HIS.
GS3055-I GSM Universal Wireless Alarm Communicator
Visonic PERS Solutions A comprehensive product offering by Mike Streeter 2 product platforms- Endless solutions!
1 Rulemaking Emergency Backup Power California Public Utilities Commission Communications Customer Education and Outreach Workshop Verizon FIOS.
Medical Gas Alarm Panels
Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 NOTES ABOUT THIS PRESENTATION: Review Oxygen-Enriched Environments.
© 2001 National Burglar & Fire Alarm Association Chapter 10 The Central Station –24 hour /7day Operation –Receive Signals –Process Signals –React.
1 Lesson 3 Computer Protection Computer Literacy BASICS: A Comprehensive Guide to IC 3, 3 rd Edition Morrison / Wells.
277 Industrial Park Rd. Franklin, NC (800) Tek-CARE ® 500 In-Service Training Copyright © TekTone ® Sound & Signal Mfg.,
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
InSeT System Inertial Sensor Tracking System Underground Mine Safety For Personnel Utilizing Inertial Sensors Technical Presentation.
BLACKOUT POWER OUTAGE By Masih Madayeni Class 3/6 English Presentation.
Linear Health & Wellness. Presentation Overview Business Model & Demographics PERS Market Linear Personal Emergency Reporting Systems New Technology –
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
1 Lesson 3 Computer Protection Computer Literacy BASICS: A Comprehensive Guide to IC 3, 3 rd Edition Morrison / Wells.
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
The Association of Electrical and Medical Imaging Equipment Manufacturers Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL.
GS3055-I GSM Universal Wireless Alarm Communicator
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
GS3055-I Installation Process
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
Smoke Notification System (SNS) Final Presentation Senior Design II November 19, 2013.
Response Care Inc. Tuesday, February 28, What can the R-Cube do? Waterproof Pendants Location Ability Door Monitoring Call Cords Pull Cords Water-Resistant.
Teknologi Pusat Data 12 Data Center Site Infrastructure Tier Standard: Topology Ida Nurhaida, ST., MT. FASILKOM Teknik Informatika.
Utilities & Engineering Department16 Blossom St., Boston Introduction to the Hospital Emergency Power Supply System (EPSS) Jason D'Antona,
Class A, B, and now N NFPA 72, 2016 Edition Dan Horon President
Common Problems with Performance/Testing of Batteries
Wireless Emergency Call System In-Service Training Presentation
Chapter 8. Electrical Systems
Carbon Monoxide Detection: Code and Legislation Updates
Chapter 19: Network Management
ICON Signals Event Alert Notification Platform Overview March 28, 2017
NFPA Circuits & Pathways
Therapeutic equipment
Industrial Radiography
Generic Site Preparation
Quick help for fault location and reliable detection of defects
Data Management Solutions for a Modernized HIS
V7 UPS Sales Training.
Wireless Emergency Call System Training Presentation
Fire Alarm Systems for Emergency Operations of Elevators
RAILWAY TRACK SNAP NOTIFICATION
InSeT System Inertial Sensor Tracking System
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Redundancy and diverse routing for data exchange
NICET Fire Alarm Tech Level 1 Practice Test # 13
EN 54 EN 54 Standard The EN 54 Fire detection and fire alarm systems is a mandatory standard that specifies requirements and laboratory test for.
Reliable—self-testing for increased confidence.
AIM Armstrong’s Intelligent Monitoring Training presentation.
Engineering Project Cable Management.
Electrical Receptacle Testing
Fire Safety for MSO, Residents, Medical Students and Nursing Students
Chapter 8. Electrical Systems
Tek-CARE®500 Wireless Emergency Call System
PAVIRO - Introduction Security Systems
GOES DCS Customer Interaction/Access Training
2008 Code Drills Health Care Facilities
**Second household member is free!**
Parker domnick hunter. Safety of Electrical and
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Presentation transcript:

Tek-CARE ® 500 Wireless Emergency Call System UL ® 2560 and the Tek-CARE ® 500 Wireless Emergency Call System

UL® Requirements Call systems typically consist of a central unit that receives signals from multiple transmitting devices, either installed in patient or resident rooms throughout a facility or worn by a patient or resident. The transmitting devices allow for two-way audio and/or visual communication between a patient or resident and a medical care professional or other authorized party. Depending on their intended use environment, call systems are evaluated for their safety consistent with the technical requirements of the following product standards:

Applicable UL® Standards UL 1069, the Standard for Safety of Hospital Signaling and Nurse Call Equipment—This Standard applies to nurse call systems and equipment found in hospitals and other acute care environments. The seventh edition of the standard, published in October 2007, incorporates specifications for wireless nurse call devices. UL 2560, the Standard for Safety of Emergency Call Systems for Assisted Living and Independent Living Facilities—Introduced in 2011, this standard applies to emergency call systems used in assisted living facilities, independent adult living centers and other non-acute care settings that are within close proximity to healthcare providers.

UL® 2560 Requirements At a minimum, UL® 2560 emergency call systems must include the following components: Central notification station—At least one central station at a fixed location that receives all calls processed through the system. Emergency call stations—At least one permanently fixed emergency call station located in every resident room or living unit. Back-up power—A backup power supply so that system operation is maintained in the event of a power loss.

UL® 2560 Requirements Additional requirements include: Call indicators—All emergency call stations and pendants must have call indicators to confirm that an call has been placed. Origination reporting—The central station must display the specific location of the emergency call. Timing of call notification—All emergency calls must be received by the central station within 60 seconds of being initiated. Call cancellation—Emergency calls can only be cancelled from the device that initiated the call. Pendants—If included, pendants and wrist bands must comply with the standard’s performance requirements. However, these devices are not a substitute for the fixed emergency call station requirement. Repeater/Locators—Not a required component but if included, must comply with the standard’s performance requirements. Low battery power—Wireless transmitters must report low battery power at least seven days before loss of power.

Differences Between UL® 2560 and UL® 1069 • Maximum voltage—UL 1069 incorporates maximum distribution voltages for equipment accessible to patients or healthcare providers. UL 2560 does not include maximum voltage requirements. • Code calls—UL 1069 has detailed requirements regarding the system’s handling of code calls. UL 2560 has no requirements regarding code calls. • Call cancellation—UL 1069 requires that calls on a portable nurse control station must be cancelled by an action separate from simply terminating communication. UL 2560 does not have this requirement. • “Orphan call” routing—UL 1069 requires that call points monitored by a portable nurse control station must also be monitored by a primary nurse control station to prevent the loss of calls due to a portable system fault or out-of-range condition. UL 2560 does not address this issue. • Fault condition signaling—UL 1069 generally sets 90 seconds as the maximum elapsed time between the occurrence of a fault or other adverse condition, and fault restoration or the generation of a fault signal. UL 2560 sets different maximum times for fault restoration of the generation of a fault signal, depending on the origin of the fault or adverse condition, with maximum times as long as 24 hours in the case of wireless call initiation stations.

Differences Between UL® 2560 and UL® 1069 • Oxygen safety—UL 1069 includes requirements covering the safety of electrical equipment operating in oxygen-enriched environments. UL 2560 includes no such requirements. • Leakage current testing—UL 1069 specifies leakage current testing under four separate conditions following humidity testing, with specific maximum leakage currents for each condition. UL 2560 requires leakage current testing only between any exposed surface of any fixed or stationary equipment and earth ground. • Device endurance—UL 1069 requires that all system devices be operational after being dropped 100 times from a height of four feet onto a concrete surface. UL 2560 reduces the number of drops required to 25 for devices intended only for use by patients and/or residents. • Clash—UL 1069 specifies 10 seconds as the maximum time between the reinitiation of a call signal and its reception by a receiver, when the original signal has encountered interference from another call signal (clash). UL 2560 sets the maximum time at 60 seconds. • Markings and instructions— UL 1069 is generally more stringent regarding required markings and installation and operation instructions, except for UL 2560-certified system devices powered directly from high voltage sources.

Additional UL® 2560 Requirements • Back-up power testing—A fundamental emergency call system configuration must incorporate a back-up power supply so that system operation is continuously maintained. UL 2560 includes a number of specific tests to assess the operation of back-up power systems. Back-up power for UL 1069 is optional and testing for back-up power is required only when back-up power is provided. • Call signals—UL 2560 requires that signals originating from a call station or wireless pendant be sent every time the call station or pendant is activated, even if the call system has not been reset. • Audible indicators—UL 2560 requires that all audible signals achieve at least a 60 decibel level. UL 1069 has no sound level requirements for audible signals. • Submersion testing—UL 2560 specifies both water spray and submersion testing of system signaling units to assess operation following their use in a shower or bath. UL 1069 does not include a submersion test.

Tek-CARE®500 System Components Central Notification Station: The Tek-BRIDGE® server processes and displays transmitter call information from the system’s receiver. Many programmable options are available to customize a facility’s system. The NC501ES Tek-BRIDGE® server includes pre-installed Tek-CARE®500 software, plus central monitoring, reporting, and text messaging capabilities. (UL® 2560 listed systems require software v.7283 or higher.) NC501ES Tek-BRIDGE® server

Tek-CARE®500 System Components Central Notification Station: The Receiver collects signals from the transmitters, repeater/locators in the field and then transfers that information to the Tek-BRIDGE®. NC501ES Tek-BRIDGE® server NC510UL Receiver The NC510UL Receiver is connected directly to the Tek-BRIDGE® via the supplied cable. The receiver transfers information received from the transmitters in the field to the Tek-BRIDGE®.

Tek-CARE®500 System Components Central Notification Station: The Uninterruptible Power Supply provides uninterrupted power for the Tek-BRIDGE® and Receiver in the event of utility power failures, brownouts and blackouts. NC501ES Tek-BRIDGE® server NC510UL Receiver When power is interrupted, the PK250B immediately cuts in to provide power until an emergency generator is activated or power is restored. Battery backup for the Tek-BRIDGE® is rated for 10 minutes. PK250B Uninterruptible Power Supply

Tek-CARE®500 System Components Repeater/Locators are strategically placed throughout the facility to collect and re-transmit signals from transmitters and other repeater/locators to the receiver. Repeater/Locators also provide general location information. IH511 Weatherproof Housing NC501ES Tek-BRIDGE® server NC510UL Receiver NC511UL Repeater/Locator Repeater/locators operate on AC power, and include internal battery backup for power outages. PK250B Uninterruptible Power Supply

TC500 UL® 2560 Listed Transmitters SF527UL Wireless Module with SF337C Waterproof Emergency Switch SF529UL Check-In/Assistance Station SF530UL Room Station SF531UL Emergency Switch SF525UL & SF525/2UL Universal Contact Transmitters SF520UL Door/Window Egress Transmitter SF515UL Motion Detector SF503UL & SF504UL Pendants

TC500 Non-UL® 2560 Listed Transmitters SF502ES Wall Transmitter SF505ES Smoke Detector SF501ES & SF501/2ES Pendants

UL® 2560 Capacity In order for Repeater/Locators to comply with the UL® 2560 standard’s supervision and alarm transmission requirements, this device/repeater matrix must be followed.

This concludes the Tek-CARE®500 Wireless Emergency Call System Presentation. Training videos are available at www.youtube.com/user/TekToneNurseCall Support literature is available at www.tektone.com/tekcare500.php