Code Jeopardy Lori Greene, AHC/CDC, CCPR, FDAI Steve Monroe, AHC, CDT, FDAI Lindsey Weiss Ingersoll Rand Security Technologies.

Slides:



Advertisements
Similar presentations
Teaching with Immersive Gaming: CPD 2 Using the NEnet Twigging Slide.
Advertisements

Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Annual Fire Door Inspection
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
Facilities Management and Design Chapter 4 Safety and Security systems.
Determining the Occupant Load
Graham On-Line Quote System Welcome to Grahams presentation of Graham On-line.
Electronic Locking and Exemption Request Form Training
Safety Training Safety First. EXITS All exit doors shall be maintained in operable condition. Exit doors shall not be locked, chained, bolted, barred,
Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013.
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
of NFPA 101 Life Safety Code 2000 Edition Means of Egress
PHOTO. NO.DATE: 01/20/14 REVISIONS Construction Services 170 Long Lane Middletown, CT WESLEYAN U N I V E R S I T Y P CHURCH STREET OLIN.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
High-Rise Hotels New Codes General Fire Safety Information Ted Erb Fire Prevention Officer Bellevue Fire Department April
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
Disabled Platform Access There are two designated parking bays immediately outside the front of the main college building. Disabled access both into the.
Decoded 2 – Fire Door Assemblies
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Welcome To ________ Jeopardy!.
Decoded 1 – Intro & Accessibility Requirements Audio - US & Canada: Audio - International: Audio Code: Mute your.
Residential Construction Residential Doors *Source: (1) Carpentry & Building Construction Feirer & Freirer.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Home Safety and Security
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
Design for Elderly and Disabled Environments Making Homes More Comfortable and Accessible Doors Part 2 of 10.
Means of Egress Chapter 4.
Fire Safety By Alicia Civile and Alexandra Fernandez.
© 2015 American Society for Healthcare Engineering, a personal membership group of the American Hospital Association 155 N. Wacker Drive, Suite 400 | Chicago,
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Chapter 44 Building Codes and Commercial Design. 2 Links for Chapter 44 Building Codes Design Categories Using the Codes Related Web Sites.
ID 440: Project 1: Hospitality Design
The Essentials of Egress
SLAC NATIONAL ACCELERATOR LABORATORY C ONTROLS D EPARTMENT S AFETY S YSTEMS S ECTION NFPA , Access Control Systems, and Emergency Egress at SLAC.
Exit Routes and Fire Protection
Courtesy: Jeff Anderson, RCDD Associate / Systems Project Manager Communications, Security & Technology Division October 14, 2015 Locking the Means of.
SCHOOL LOCKDOWN TASK FORCE For California Schools K-12 Team 2 Addressing the ADA, SFM, DSA and CDE Code Requirements.
Means of Egress Part 3 Chapter 4.
ID 234 Building Codes Fall 2012 Vertical Components of Egress.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
8.02 Home Safety and Security. Fire Safety Smoke Detectors Sends a loud warning signal if a fire starts Easy to install Should be placed on each floor.
1 Ideas Board “Inspiration From Those Who Have Inspired”
“Allegion” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of.
About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Mayor’s Office on Disability City and County of San Francisco Discussion of Common Design and Construction Errors.
“My Room” Project The Massachusetts Code Book and the rules that apply.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
“Electromagnetic Locks, Electric Strikes
Louisiana State University Radiation Safety Office
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
“Allegion” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of.
Home Safety and Security
Decoded 1 – Intro & Accessibility Requirements

UCOP Emergency Building Evacuation 415 – 20th Street
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
Fire Door Inspections Qualified Training
ASHRAE, California Title 24, NEC
INTD 405 Modern Practices in Interior Design DOOR & WINDOW SCHEDULES
Locking the Means of Egress in Health Care Facilities
Code Development & Adoption
Building standards Mr. Da Silva.
“Allegion” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of.
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Presentation transcript:

Code Jeopardy Lori Greene, AHC/CDC, CCPR, FDAI Steve Monroe, AHC, CDT, FDAI Lindsey Weiss Ingersoll Rand Security Technologies

www.iHATEhardware.com or www.iDIGhardware.com

Let Me Let Me Hot Wired! In! Out! Stuff! $400 $400 $400 $400 $600 $600 $800 $800 $800 $800 This slide plays the Jeopardy music. When you’re sick of the music, advance to the next slide which is the game board. $1000 $1000 $1000 $1000

Let Me Let Me Hot Wired! In! Out! Stuff! $400 $400 $400 $400 $400 $400 $600 $600 $600 $600 $600 $600 $600 $600 $800 $800 $800 $800 $800 $800 $800 $800 Prior to beginning the game, I have the teams choose team names and write them on a tent card. I pick the name I like best to go first. That team chooses a category and a dollar amount (they don’t have to go in any particular order). The categories are: Let Me In = Accessibility Let Me Out = Egress Hot Stuff = Fire Doors Wired = Electrified Hardware Don’t click on Alex Trebeck until you’re ready for Final Jeopardy. Clicking twice on a dollar value will take you to the applicable question. Then advance through the slides until you reach a black slide (don’t advance past the black slide). Click anywhere on the black slide to return to the board. You can change the questions and answers, and you can add more slides, as long as you add them before the black slide. The team that rings in first gets to answer the question. If they answer correctly, the dollar value is added to their score. If they answer incorrectly, the dollar value is subtracted from their score and the teams can ring in again. I let two teams try and if they’re still incorrect I just tell them the answer. It’s hard to play this game with only one instructor. I bring another SSC person with me to be the spotter (see who rings in first) and the scorekeeper. I hand out a bell or horn to each team, and I’ve also used flags when I’ve had large teams in a big room. When all of the questions have been asked/answered, click on Alex Trebeck to go to Final Jeopardy. Teams have to write down their wager before they see the question. They can wager up to their current point value. If any teams are in the red (always), I add enough points to each team to get the negatives into the positive. I collect the wagers and then read the question. I like to make it an open book question and let them use the code booklet. That gets them to open it up and check it out a bit. I collect the answers to Final Jeopardy. If a team gets it wrong, their wager is subtracted from their score. If they get it right, the wager is added to their score. I give out $10 Dunkin’ Donuts gift cards to the winners and $5 DD gift cards to the losers. $1000 $1000 $1000 $1000 $1000 $1000 $1000 $1000

What is the maximum height for a threshold on an accessible door? $400

What is the maximum height for a threshold on an accessible door? Ramp $400

According to ADA and ICC/ANSI A117 According to ADA and ICC/ANSI A117.1 - is a lever handle required to return back toward the door? A) Yes B) No C) Only if the door is fire rated. $600

According to ADA and ICC/ANSI A117 According to ADA and ICC/ANSI A117.1 - is a lever handle required to return back toward the door? A) Yes B) No, it is not required by either of these publications. C) Only if the door is fire rated. $600

What is the minimum clearance required for accessible door pulls? D) No specific requirement. $800

What is the minimum clearance required for accessible door pulls? D) No specific requirement. $800

Pulls GOOD ??? Projection of pull is not specified. Pull must be open so hand can slide through. GOOD ???

What is the minimum clear width of an accessible door? A) 36”, measured between jambs B) 36”, measured between the face of the door at 90 degrees and the stop on the strike jamb C) 32”, measured between jambs D) 32”, measured between the face of the door at 90 degrees and the stop on the strike jamb $1000

What is the minimum clear width of an accessible door? A) 36”, measured between jambs B) 36”, measured between the face of the door at 90 degrees and the stop on the strike jamb C) 32”, measured between jambs D) 32”, measured between the face of the door at 90 degrees and the stop on the strike jamb $1000

According to the IBC - where is it acceptable to install a deadbolt in a means of egress? A) On the back door of a restaurant that is equipped with a lockset. B) On a door with panic hardware. C) On an individual public bathroom or fitting room that has a privacy set. D) On a guest room at the No-Tell Motel. E) Deadbolts are never allowed in a means of egress. $400

According to the IBC - where is it acceptable to install a deadbolt in a means of egress? A) On the back door of a restaurant that is equipped with a lockset. B) On a door with panic hardware. C) On an individual public bathroom or fitting room that has a privacy set. D) On a guest room at the No-Tell Motel. E) Deadbolts are never allowed in a means of egress. $400

Egress doors must open with one motion and no prior knowledge or special tools (keys).

IBC-2003 - 1008.1.8.3 “Exception 4: Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool.”

Are panic devices required on electric rooms? A) Yes, all electric rooms. B) No, as long as it is not a high hazard occupancy. C) Yes, if required by NFPA 80. D) Yes, if required by NFPA 70. $600

Are panic devices required on electric rooms? A) Yes, all electric rooms. B) No, as long as it is not a high hazard occupancy. C) Yes, if required by NFPA 80. D) Yes, if required by NFPA 70. $600

National Electric Code >600 volts >1200 amps transformer vaults “...door(s) shall open in the direction of egress and be equipped with panic bars, pressure plates, or other devices that are normally latched but open under simple pressure.”

According to the 2003 IBC - where is panic hardware required? $800

According to the 2003 IBC - where is panic hardware required? A) Any door serving more than 100 people. B) Any door serving more than 50 people. C) Doors serving certain occupancy types with more than 100 people. D) Doors serving certain occupancy types with more than 50 people. $800

According to the 2003 IBC - where is panic hardware required? A) Any door serving more than 100 people. B) Any door serving more than 50 people. C) Doors serving certain occupancy types with more than 100 people. IBC 2006/2009 changes this to 50 people. D) Doors serving certain occupancy types with more than 50 people.

Bonus Question! Which occupancy types require panics when occupied by more than 100 people? Assembly Educational Day Care (NFPA 101)

Exit Devices Where panic hardware is required, actuating portion of device (touch-pad or cross-bar) must be at least half the width of the door.

Exit Devices No additional locking device (padlock, hasp, chain, deadbolt, etc.) shall be installed on a door which requires panic hardware.

According to the 2003 IBC - where are manual flush bolts allowed? Entrance doors to retail establishments. Storage or equipment rooms. Doors that are left unlocked during the day. All of the above. $1000

According to the 2003 IBC - where are manual flush bolts allowed? Entrance doors to retail establishments. Storage or equipment rooms. Doors that are left unlocked during the day. All of the above. $1000

The 2009 IBC contains new requirements related to flush bolts. Doors not required for egress in dwelling units, and storage/equipment rooms. B, F, or S occupancy where doors serve an occupant load of <50 B, F, or S occupancy with sprinklers where inactive leaf is not needed for egress width I-2 patient rooms – self-latching bolts No dummy lever, push rail, etc. on inactive leaf for the 3

Where are door closers required? A) Fire doors. B) Doors in smoke barriers. C) Storage rooms > 100 square feet. D) All of the above. $400

Where are door closers required? A) Fire doors. B) Doors in smoke barriers. C) Storage rooms > 100 square feet. D) All of the above. Table 302.1.1 $400

Bonus Question! Name a door that is fire-rated, but is not required to be self-closing or automatic-closing. Communicating door between hotel rooms.

What field modifications can be performed on a fire rated opening? A) Any preparations as long as they are done by a certified installer. B) Prep for electric strike. C) Prep for mortise lock body. D) Prep for fire exit hardware with lever trim. E) Add a 10” x 10” glass lite. F) None of the above. $600

What field modifications can be performed on a fire rated opening? A) Any preparations as long as they are done by a certified installer. B) Prep for electric strike. C) Prep for mortise lock body. D) Prep for fire exit hardware with lever trim. E) Add a 10” x 10” glass lite. F) None of the above. $600

Is there a product available that allows a fire door to be push/pull function? A) No, fire doors have to latch. B) Yes, a fail-secure electric strike. C) Yes, fire exit hardware with electrified lever trim. D) Yes, fire exit hardware with electric latch retraction. $800

Is there a product available that allows a fire door to be push/pull function? A) No, fire doors have to latch. B) Yes, a fail-secure electric strike. C) Yes, fire exit hardware with electrified lever trim. D) Yes, fire exit hardware with electric latch retraction. $800

What are the maximum clearances allowed for fire-rated wood doors? $1000

What are the maximum clearances allowed for fire-rated wood doors? $1000

What are the maximum clearances allowed for fire-rated wood doors? A) 1/16” at the perimeter and meeting stiles, ¾” at the bottom. B) 1/8” at the perimeter and meeting stiles, ¾” at the bottom. C) 3/16” at the perimeter and meeting stiles, ¾” at the bottom. D) ¼” at the perimeter and meeting stiles, ¾” at the bottom. $1000

What are the maximum clearances allowed for fire-rated wood doors? A) 1/16” at the perimeter and meeting stiles, ¾” at the bottom. B) 1/8” at the perimeter and meeting stiles, ¾” at the bottom. C) 3/16” at the perimeter and meeting stiles, ¾” at the bottom. D) ¼” at the perimeter and meeting stiles, ¾” at the bottom. $1000

According to ICC/ANSI A117 According to ICC/ANSI A117.1 - which exterior doors require automatic operators? A) One exterior door of each public building must have an automatic operator. B) If the building has an occupant load of > 100, one exterior door must have an automatic operator. C) Automatic operators are not required by this publication. $400

According to ICC/ANSI A117 According to ICC/ANSI A117.1 - which exterior doors require automatic operators? A) One exterior door of each public building must have an automatic operator. B) If the building has an occupant load of > 100, one exterior door must have an automatic operator. C) Automatic operators are not required by this publication. $400

Opening Force Exterior Hinged Doors – ??? (Of the New England states, only Massachusetts currently includes the 15-pound limit) Interior Hinged Doors - 5 pounds Sliding or Folding Doors - 5 pounds Fire doors shall have the minimum opening force allowable by the appropriate administrative authority (size 3 closer recommended). $400

If a high school is having trouble with books “disappearing” out of the library’s emergency exit which code-compliant product would help? A) An electric latch retraction panic device. B) A panic device with electrified lever trim. C) A delayed egress lock. D) An alarmed exit device. $600

If a high school is having trouble with books “disappearing” out of the library’s emergency exit which code-compliant product would help? A) An electric latch retraction panic device. B) A panic device with electrified lever trim. C) A delayed egress lock. D) An alarmed exit device. $600

Per the IBC, delayed egress devices are not allowed on Assembly, Educational, or High Hazard occupancies.

Delayed Egress Locks Not allowed on Assembly, Educational, or High Hazard occupancies. Must release upon fire alarm Must release upon loss of power Must be capable of being unlocked by a signal from an emergency control station

Delayed Egress Locks Must release within 15 seconds after force is applied for 1 second Manual rearm Audible local alarm Signage Occupant must not encounter more than 1 delay before entering an exit

According to the 2003 IBC - doors with electromagnetic locks require which of the following? $800

According to the 2003 IBC - doors with electromagnetic locks require which of the following? A) Motion Sensor B) Emergency Push Button C) Unlock on Fire Alarm/Sprinkler D) Unlock on Power Failure E) All of the above $800

According to the 2003 IBC, doors with electromagnetic locks require which of the following? A) Motion Sensor B) Emergency Push Button C) Unlock on Fire Alarm/Sprinkler D) Unlock on Power Failure E) All of the above $800

Access-Controlled Egress Doors Allowed in occupancies: Assembly, Business, Educational, Mercantile, R-1 (hotels), R-2 (multiple-family dwellings, dormitories) Lock must be released by all of the following: Sensor on egress side (or switched panic device?) Push button on egress side, unlocks door for 30 seconds Fire alarm or sprinkler system Loss of power

The stair doors in a high rise building must be equipped with what type of lock? A) Fail safe electric lock B) Fail secure electric lock C) Fail safe electric strike D) Classroom function lockset E) Panic device with lockable lever handle $1000

The stair doors in a high rise building must be equipped with what type of lock? A) Fail safe electric lock B) Fail secure electric lock C) Fail safe electric strike D) Classroom function lockset E) Panic device with lockable lever handle $1000

Stairwell Re-Entry Stairwell doors are often locked to prevent entry to restricted floors. During a fire, occupants must be able to move from the stairwell onto floors through doors that are normally locked.

Stairwell Re-Entry BOCA National Building Code passage sets, or all doors unlock upon fire alarm ICC International Building Code - 2003 stairs serving 4 stories or less are exempt ICC International Building Code – 2006, 2009 stairs serving 4 stories or less – doors must have the ability to be unlocked from the fire command center NFPA 101 / NFPA 5000 passage sets, or all doors unlock upon fire alarm, or “Selected Re-Entry”

Final Jeopardy! How much will you wager?

According to the 2003 IBC, what test standard must be used for fire doors?

According to the 2003 IBC, what test standard must be used for fire doors? Positive pressure test – UL10C or NFPA 252 with the neutral pressure plane at 40” above the sill after 5 minutes.