Room Controller RC/A 8.1 Room Controller economic flexible modular.

Slides:



Advertisements
Similar presentations
HYDRAULICS & PNEUMATICS
Advertisements

In this presentation you will:
Module 2: Hardware and Terminology
PLC: Programmable Logical Controller
Electro-Pneumatics Module 1
DUAL POWER SUPPLY MODULE
1 Intelligent Lighting Solutions for Professionals.
Programmable Logic Controller (PLC)
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
ABB i-bus® EIB Shutter Actuators
New Electric Actuators EA Type
CMV-NET Chigo VRF Network Centralized Control System
Fan Coil Controller FC/S 1.1
VARLOGIC NRC12 Varmetric Controller
G. Schlag / STO-GM / Novembre 2012
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
DALI Scene Controller HDL-MC-DALI.431.
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
automatic recognition of load-type superior functionality
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
ABB i-bus® KNX Valve Drive Actuator VAA/A
August 2012 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Energy Module EM/S Energy Actuator SE/S © ABB 20 May 2018 | Slide 1.
Dimmer 6fold 10V Actuator M/DA
ABB i-bus® KNX Room Solutions
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
ABB i-bus® EIB Display and Control Tableau
ABB i-bus® EIB / KNX Thermoelectric Valve Drive TSA/K , TSA/K 24
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
ABB i-bus® EIB Electronic Switch Actuator, 4-fold
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Premium, RM/S 2.1
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Room Master, Basic, RM/S 1.1
Zone Terminal MT/U Technical Overview
Wireless 4 Buttons Touch Panel
What is meant by ‘Preventive Monitoring’?
2N® Access Unit Touch Keypad
ABB i-bus® EIB / KNX Weather Station WS/S 4.1
Wireless 3 Buttons Touch Panel
Connections Topology of Apollo ACS.
Security Module, MDRC SCM/S 1.1
Jörn Kruse / STO-G / Mai 2009 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX The „smaller“ Room Controller RC/A 4.2 © STO/G - Slide 1.
RAILWAY TRACK SNAP NOTIFICATION
Curtain Actuator M/W
Grid feeding monitoring relay
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
De-Ice control devices
2N® Access Unit Touch Keypad
ABB i-bus® EIB / KNX Fault Monitoring Unit SMB/S 1.1
OFA200 Tim Stockwell.
4 channels, each as input or output
2 channels, each as input or output
Electronic relay ER/U 1.1 contact TU/W 1.1 US/U 4.1 ER/U 1.1
Universal Interface, 12-fold, FM US/U 12.2
Universal I/O Concentrator UK/S 32.2
ABB i-bus® EIB Logic Module LM/S 1.1
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
ABB STOTZ-KONTAKT GmbH DALI-Light Controller DLR/S M
Flotection: Building Main Shutoff System
Universal Dim Actuator UD/S
ACOE347 – Data Acquisition and Automation Systems
ABB i-bus® EIB / KNX Data Logging Unit BDB/S 1.1
Universal Interrupted Electronic Oil Primary R7184U Training Module
Detailed information FOR INTERNAL USE ONLY! CUBE20.
The efficient interface for lighting control
Presentation transcript:

Room Controller RC/A 8.1 Room Controller economic flexible modular

Room Controller RC/A 8.1 Trends in building installation Increasing number of applications per room Increasing functionality in the applications Decentralized mounting of devices in the inserted ceiling and underfloor wiring installation Focus on reduction of fire loads Less time and effort for assembly&mounting Cost optimized solutions

Room Controller RC/A 8.1 Decentralized Installation How about ... ... one device per room to control all functions Room2 Room3 Mains Supply EIB

Room Controller RC/A 8.1 The “one device per room“- principle Security & Surveillance Operation Controlling heating & cooling devices Lighting: switching on/off and dimming Controlling shutters & blinds Constant lighting control

Room Controller RC/A 8.1 Decentralized Installation: Some Advantages Mounting and test on location Less wiring  Reduction of fire load  Increasing clearness Flexibility in the planning state: functions can easily be changed or extended Quick planning and installation, especially for many rooms with similar functions Room1 Room2 Room3 Mains Supply EIB

Room Controller RC/A 8.1 The Technics

Room Controller RC/A 8.1 Overview Modular device for up to eight pluggable modules Surface mounted device, optimized for underfloor wiring and inserted ceiling Decentralized installation concept Connection via pluggable screw type terminals Testing facilities by manual operation of the outputs

Room Controller RC/A 8.1 Design Overview EIB Power input 24 V DC for shutter drives (optional) Basis device EIB 8 pluggable modules 12 V DC auxiliary supply (optional!) for power backup Power Input: 3x115...230V, 16A max. Outputs to end devices

Room Controller RC/A 8.1 The housing: for the heavy duty application in the underfloor and inserted ceiling Quick screwing Splash guard: IP 54 270 mm Non halogen housing 50 mm 316 mm

Room Controller RC/A 8.1 The inside 18 cable entries Bus connection Manual operation and LED-display Push button for programming Power inputs and supply

Room Controller RC/A 8.1 The module slots When inserted, the modules are connected automatically to the mains The slot assigns the module to the according phase

Room Controller RC/A 8.1 The Power Supply: A Professional Security Concept The device is supplied by the mains  low consumption of bus current  the internal functions remain unaffected on bus voltage failure! The function is guaranteed as long only one phase remains active The optional 12 V auxiliary voltage supply ensures the full operation also on complete 230 V voltage failure Power input: 3-phase L1 L2 L3 2-phase L1 L2 1-phase L1

Room Controller RC/A 8.1 The Modules Connection terminals (plug in screw type terminals) Power input Contacting of the control lines

Room Controller RC/A 8.1 Quick installation 1. Mounting the base device 2. Plug in of the modules 3. Connection of the end devices 4. Applying of voltage 5. Testing (without bus voltage or programming)

Room Controller RC/A 8.1 Inserting the Modules Simple Insertion and snapping in Automatic connection to the mains supply Every module can be inserted into any slot

Room Controller RC/A 8.1 Strain relief The strain relief is carried out on the cable entry Simple fixing by cable ties

Room Controller RC/A 8.1 Manual operation and display Module selection LEDs and push buttons The manual operation can be carried out without programming or bus voltage

Room Controller RC/A 8.1 The product line RC/A 8.1 Room-Controller, Basis Device for 8 Modules RC/A 8.1 Binary Input Module, 4-fold, 115/230 V BE/M 4.230.1 Binary Input Module, 4-fold, 12/24 V BE/M 4.24.1 Binary Input Module, 4-fold, Cont. Scanning BE/M 4.12.1 Switch Actuator Module, 2-fold, 6A SA/M 2.6.1 Shutter Actuator Module, 2-fold, 230 V AC JA/M 2.230.1 Shutter Actuator Module, 2-fold, 24 V DC JA/M 2.24.1 Switch/Dim Actuator Module, 2-fold, 6A SD/M 2.6.1 Light Controller Module, 1-fold, 6A LR/M 1.6.1 Univ. Dim Actuator Module, 1-fold, 300 VA UD/M 1.300.1 Electr. Switch Actuator Module, 2-fold, 230 V ES/M 2.230.1 Electr. Switch Actuator Module, 2-fold, 24 V ES/M 2.24.1

Room Controller RC/A 8.1 Modules and Functions

Room Controller RC/A 8.1 Central Functions Status signaling via Bus in case of  module failure  wrong module mounting  excess temperature Module configuration can be read out via Bus Monitoring Bus communication: Adjustable behaviour in case of failure The basis device manages the bus-communication: only one bus device!

Room Controller RC/A 8.1 Binary Input Modules BE/M 4.230.1, BE/M 4.24.1, BE/M 4.12.1 4 inputs per module Voltage types: - 230 V AC / DC - 12 / 24 V AC / DC - contact scanning

Room Controller RC/A 8.1 Functions „Binary Input“ Functions (Overview) Switch sensor Dimming sensor Shutter sensor Send value Controlling light scenes Multi operation Switching sequence Pulse counter Standard functionality „Binary Input“ (e.g. US/U x.2)

Room Controller RC/A 8.1 Switch Actuator Module SA/M 2.6.1 2 Outputs High switching current (16 A / AC1) Max. continuous current 6 A per output C-Load: max. 70 µF

Room Controller RC/A 8.1 Function „Switch Actuator“ Time functions Staircase function (with „pumping up“ and „warning“) Switch on / off delay Flashing 1-bit-presets: 4 per output 8-bit-scene: 5 allocations per output 2 assignment objects per output AND / OR / XOR / door function Forced operation (2-Bit) Cyclical surveillance of switching object Level reporting Fan-Coil-Function

Room Controller RC/A 8.1 Shutter Actuator Module JA/M 2.230.1, JA/M 2.24.1 2 independent outputs Voltage types: - 115 / 230 V AC - 12 / 24 V DC max. continuous current 6 A per output

Room Controller RC/A 8.1 Functions „Shutter Actuator“ Functions Weather alarm: 2 Objects Forced operation direct positioning Automatic shutter control system prepared for: facade-control with Shutter Control Unit JSB/S 1.1 Standard functionaliy „Shutter actuator“, (equivalent to JA/S ..., slightly limited)

Room Controller RC/A 8.1 Switch / Dim Actuator Module SD/M 2.6.1 2 switch / dim outputs : 1...10 V control outputs and relay outputs max. continuous current 6A per output Switching current 10 A

Room Controller RC/A 8.1 Light Controller Module LR/M 1.6.1 For constant lighting control 1 switch / dim output: 1...10 V operate output and relay output 1 light sensor input Max. switching current 10 A Max. continuous current 6 A

Room Controller RC/A 8.1 Universal- Dim Actuator Module UD/M 1.300.1 1 dimming output for inductive or capacitive charges Automatic load detection (can be deactivated!) Output power: 300 W Min. output power: only 2 W (!) Compensation of frequency shifting, voltage instablities and ripple control signals

Room Controller RC/A 8.1 Functions „Dim Actuator“ 1-Bit-Presets: 4 per output 8-Bit-Szene: 5 allocations per output Staircase function with “pumping up” and “warning” function Adjustable staircase time (via bus) Forced operation Adjustment of lighting characteristic For Universal Dim Actuator: detailed error code about the operating state of the device Standard functionality „Dim Actuator“, similar for every dim actuator type

Room Controller RC/A 8.1 Electronic Switch Actuator Module ES/M 2.230.1 and ES/M 2.24.1 2 semi-conductor outputs, noiseless and wastage free Voltage types: - 115 / 230 V AC / DC - 12 / 24 V AC / DC max. continuous current 700 mA max. starting current 1 A

Room Controller RC/A 8.1 Function „Heating Actuator“ Addressing by room thermostat via 1-bit or 8-bit object (“continuous control“) Forced operation, e.g. for maintenance purposes Automatic cyclical valve purge Cyclic supervision of the room thermostat - on communication failure a fault operation is executed and an error message is sent on the bus

Room Controller RC/A 8.1 Universal Functions The following functions are provided for every module: Scene controlling with the objects 1-bit-preset and 1-bit-scene Forced operation Further the details ... >>>

Room Controller RC/A 8.1 Universal Function I : Controlling Scenes What is it? Fix states that are parameterized and stored in the actuator (e.g. switching states or brightness values) are called by a single telegram Which devices? Switch actuators, shutter actuators, dim actuators What is it used for? For comfortable operation of room functions. In addition to that for flexible reaction on events, so that logic functions can be considerably reduced. >>>

Room Controller RC/A 8.1 Controlling Scenes (continued) How does it work? Example: When leaving a building, the corridor lighting is dimmed to 30% and the other lighting is switched off. The shutters in the ground floor are closed, all others are open. 1 telegram: „Call scene “ Push button 30% 0% up >>> down

Room Controller RC/A 8.1 Controlling Scenes (continued) What else? Scenes can also be adapted to the user‘s demands: When pressing the push-button for a long time (e.g. 3s) , the actuator stores the current output state in memory. The next time the scene is called, the actuator will restore this state. 1 Telegram: „Store scene“ Push button 40% 0% 40% >>> down

Room Controller RC/A 8.1 Contolling Scenes with Dimmable Lighting old Example 1 new old Luminance Example 2 new TÜ Time Call On calling the scene, the new brightness value can be called immediately or gradually. Gradually dimming is defined by an transition time between the old and the new brightness. >>>

Room Controller RC/A 8.1 Controlling Scendes (Continued) Two possibilities to control a scene: 1-Bit-Preset 1-Bit-Objekt for calling 1-Bit-Objekt for storing 8-Bit-scene 8-Bit-object for calling and storing the scene Object value contains a scene number. In the parameters the outputs are assigned to one or more a scene numbers. The actuators of the Room Controller are able to cope with both possibilies. >>>

Room Controller RC/A 8.1 Advantages of 1-bit presets <<< More flexible and clear than 8-bit-scenes Extra function „Reset“: A stored scene value can be reset to the parameterized value (e.g. after an unintentional storing) Extra function „Restore“: After having called a scene, it is possible to restore the state before calling. Example: A presentation room is darkened. After the presentation has been finished, the lighting is restored to the value before the presentation. <<<

Room Controller RC/A 8.1 Universal Function II : Forced operation What is it? An output is set into a certain position and blocked for further operation. Which devices? Switch Actuator, Shutter Actuator and Dim Actuator What is it used for? Maintenance purpose Blocking the normal operation in rooms that are accessable to visitors Security applications >>>

Room Controller RC/A 8.1 Universal Function II : Forced loop-control How does it work? 2-Bit object for every output: Object value Meaning: Forced loop-control is ... 0 (binary: 00) 1 (binary: 01) inactive (normal operation is possible) 2 (binary: 10) active, switch off / shutters up 3 (binary: 11) active, switch on / shutters down <<<