T-simulation OUTLINE Inputs to the T-simulation: chips, boards, crate mechanics and fan T-simulation performed into two steps: On large scale: simple AM.

Slides:



Advertisements
Similar presentations
International Symposium on Low Power Electronics and Design Qing Xie, Mohammad Javad Dousti, and Massoud Pedram University of Southern California ISLPED.
Advertisements

Building Envelope. Energy Conservation House design and orientation Lifestyle changes Energy efficiency.
RUSSIAN ACADEMY OF SCIENCES PROGRAM SYSTEMS INSTITUTE Optimal Control of Temperature Fields for Cooling of Supercomputer Facilities and Clusters and Energy.
FE electronic box Construction of end piece OT module Electronic components Mechanics Cooling.
CALICE Thermal Simulations Steve Snow 6/3/06 Aim to predict the temperature values and gradients within the CALICE structure. Use spreadsheet estimates.
Cooling of Chips in Circuit Boards. Problem One way to cool chips mounted on circuit boards is to encapsulate the boards in metal frames that provide.
Mechanical Status of ECAL Marc Anduze – 30/10/06.
Temperature-Aware Design Presented by Mehul Shah 4/29/04.
M. Yoda, S. I. Abdel-Khalik, D. L. Sadowski and M. D. Hageman Woodruff School of Mechanical Engineering Extrapolating Experimental Results for Model Divertor.
Very Low Profile Fully Buffered DIMM Bill Gervasi Vice President, DRAM Technology SimpleTech The subject matter of this presentation is a work in progress.
Influence of the Gravity, Vacuum and RF on CLIC Module T0 Behavior R. Raatikainen.
Design of Heat Sinks P M V Subbarao Mechanical Engineering Department IIT Delhi Success Based on Cooling Challenges …….
Motherboard AKA mainboard, system board, planar board, or logic board. It is printed circuit board found in all modern computers which holds many of the.
 Components have ratings  Ratings can be Voltage, Current or Power (Volts, Amps or Watts  If a Current of Power rating is exceeded the component overheats.
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection condition.
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
COMPUTER MAIN PARTS. softwared HARDWARE 8 COMPONENTS.
Engineering Department ENEN 16/08/2013 LR - BBC Pre-Study 1 STATUS of BBC DESIGN and ENGINEERING : PRELIMINARY RESULTS G. MAITREJEAN, L. GENTINI.
RO400FC Forced convection hot air reflow oven. In a flexible production, what do you need for soldering of  Complex PCB’s  Soldering of fine pitch on.
1 Denis Grondin / Julien Giraud – 01 December 2008 SLAB COOLING Denis Grondin Julien Giraud
1 VI Single-wall Beam Pipe tests M.OlceseJ.Thadome (with the help of beam pipe group and Michel Bosteels’ cooling group) TMB July 18th 2002.
© International Rectifier DirectFET  MOSFETs Double Current Density In High Current DC-DC Converters With Double Sided Cooling.
Submerged PC Cooling By: Patrick Hague Geoffrey Clark Christopher Fitzgerald Group 11.
4/12/2011Controller Cooling Test1 Array Controller Cooling Test Bill Hoffmann April 12, 2011 This is a report on a test of the chilled water-to-air heat.
06-November-2013 Thermo-Mechanical Tests BE-RF-PM Review of the CLIC Two-Beam Module Program Thermo-Mechanical Tests L. Kortelainen, I. Kossyvakis, R.
Mechanical Status of EUDET Module Marc Anduze – 05/04/07.
Analytical Modeling of Forced Convection in Slotted Plate Fin Heat Sinks P. Teertstra, J. R. Culham & M. M. Yovanovich Microelectronics Heat Transfer Laboratory.
Thermo-mechanical activities at Valencia V. Castillo, C. Lacasta, A. Oyanguren, P. Ruiz 8 th International Workshop on DEPFET Detectors and applications.
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection environment. John Clem,
1 Daya Bay RPC Gas Safety System - Gas Cabinet Test Report Changguo Lu, Kirk McDonald Princeton University (October 11, 2009)
ATCA cooling tests Claudio Bortolin (PH-ADO) Damian Dyngosz (PH-DT) George Glonti (PH-UAT) Julian Maxim Mendez (PH-ESE) Lukasz Zwalinski (PH-DT) xTCA IG.
1 13 Octobre 2011 Laurent Roy ATCA Crate / Infrastructure in place -Rack in D3: dimension -Electrical power availability -Tell1 racks running in D3 (air.
Marc Anduze – CALICE Meeting – KOBE 10/05/07 Mechanical R&D for Technological EUDET ECAL Prototype.
06/03/2002Ivan Hruska EP/ATE1 LV brick for TILECAL  Overview Design summary Results from 2nd radiation tests in PSI Villingen Bulk supply Plans for future.
FRESCA II dipole review, 28/ 03/2012, Ph. Fazilleau, M. Durante, 1/19 FRESCA II Dipole review March 28 th, CERN Magnet protection Protection studies.
ATCA COOLING PROJECT INTERSHIP FINAL PRESENTATION Piotr Koziol.
FED Temperature Measurements: Greg Iles31 March FED temperature measurements –Will components on FED exceed operating temperature in CMS? Analogue.
Date of download: 5/27/2016 Copyright © ASME. All rights reserved. From: Experimentally Validated Computational Fluid Dynamics Model for a Data Center.
System Demonstrator: status & planning The system demonstrator starts as “vertical slice”: The vertical slice will grow to include all FTK functions, but.
News on FTK rack infrastructure A. Lanza – INFN Pavia FTK Italy meeting –
FTK crates, power supplies and cooling issues 13/03/20131FTK-IAPP workshop - A. Lanza  Racks, crates and PS: requirements  Wiener crates  Rittal crates.
AMBFTK Report AMBFTK: problems to solve Power distribution: Crates – compatibility with CDF crates? Thermal dissipation: Cooling Signals I/O:
Marc Anduze first drawings of Ecal eudet module COPIED FROM : Marc Anduze PICTURES FROM : CALICE/EUDET electronic meeting – CERN – 12 July 07.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
ATLAS ATCA cooling evaluation project Claudio Bortolin (EP-ADO-PO) Michal Kalinowski (EP-ADO-PO) Lukasz Zwalinski (EP-DT-FS) ATLAS cooling team – 2016.
Power consumption (Watts) LBB27 ROS18 TSC50 TIM8 1 SC crate416 Alignment20 TOTAL per rack906~1 kW X2J22X2J02 With a water flow of 10 l/min, it should.
FTK infrastructures and DCS 02/12/20101FTK Initial Design Review - A. Lanza  Crates  Single rack layout  Cabling  Rack placement  DSS  DCS.
Smruti R. Sarangi IIT Delhi
LAMB: Hardware & Firmware
FTK infrastructure in USA15 Status and plans for 2015 A
AM system Status & Racks/crates issues
Date of download: 11/2/2017 Copyright © ASME. All rights reserved.
T1 Electronic status Conclusions Electronics Cards:
Aachen Status Report: CO2 Cooling for the CMS Tracker
TBM thermal modelling status
FDIRC PMTs dimensional tolerance
SCT/Pixel Draft Rack Layout rcj
Effect of Using 2 TE units on Same Heat Sink
Motivation Performance of power plants using ACC may largely be affected by wind conditions Up to 10% reduction in net plant power output for 10 m/s wind[1]
Compilation of Dis-/Advantages of DC-DC Conversion Schemes
Characterizing FOX Demonstrator Test Setups for LArDPS to FEX Modules at CERN RuthAnn Gregory.
ATLAS USA15 - Rack 52U with 9U crates, remote PS
Thermal Model Feedback
Aachen Status Report: CO2 Cooling for the CMS Tracker
Cloud Computing Data Centers
Advanced Micro Devices, Inc.
THERMODYNAMIC IN ELECTRONICS
Quench calculations of the CBM magnet
3 x Transformer boards ISO View Fans Oriented as in Super Micro Case
How to design the size of heatsink
Presentation transcript:

T-simulation OUTLINE Inputs to the T-simulation: chips, boards, crate mechanics and fan T-simulation performed into two steps: On large scale: simple AM chip model, but full crate sim, AMB_V2 - Results On small, deteailed scale: AM06 package detailed model inserted, AMB_V3, but simplified crate simulation- Results Future cooling tests plan and conclusions

Detailed T-simulation (IMEC) for the new AMBSLP  to know T on silicon! Optimize chip package and boards dissipation Estimate the temperature in the chip silicon knowing T just outside the package ALL details must be taken into account from package design to crate, PS, fan design Heat Sink Die size Die underfill Substrate RDL Tall DC-DC converters in the middle AMB with four LAMBs model LAMB model Crate & fan model What we have understood is that in the crate the pcb is hot and the air is very cold. This happens because the resistors do not exchange heat with the air. So these boards full of resistors are good to stress the power but not so good to emulate the behavior of the final Associative Memory Boards. Now we are repeating the test with 3 AMBboards full of old Amchips, with mechanical and termal characteristics more similar to the final ones. We will use also a different fans module, the Wiener Hyper Blower, to avoid the hot spots and maximixe the air flux. Understanding the importance of the package and PCB design to optimize the heat dissipation, we asked also to IMEC a temperature simulations at the chip, board and global system level.

NOVEMBER 2014 SIMULATION Inputs - AMB_V2 Large Artix FPGAs DC-DC 1,2 V

Air flow in the crate simulation Not efficiently cooled slots Bad slots

Next to Worse AM pos Worse AM pos

10 m/s Simulated As uniform 4 m/s Simulate the Worse case (blue) with Max=3,2 & 4 m/s

AMB_V2 Full crate sim Simple AM06 Lower air flux

94.5o Inside the red box: max T = 94.5o Inside the black box: max T = 79o max in the Bad slots with red arrows (on the left of the box) On the right part of the black box (good slots) T= 61o, 67o, 72o, 73o, 70o, 69o, 75o and 64o These are temperatures in good slots where the DC-DC is far.

NEW T-SIMULATION March 2015 Improving the AMBSLP layout Detailed model for AM package (see next slides) AMB_V2 AMB_V3 New inputs to the simulation TOT= 247W

AM chip + PCB piece With air flow (4 m/s) Results 39,75 Results

55 C

99,4 Worse slot 99 degree on Die is acceptable

88 Near to worse-slot 88 degree on Die is acceptable

3 slots are even worse than worse simulated case CPU position + 2 SSB Worse case shown Other 3 slots have similar behaviour as worse cases shown by T-sim 2 SSB + 1AM Max T ~99 ±5 degrees, acceptable However it is a conservative estimate: Average flux larger than the simulated one The simulation does not allow the x component of air velocity Lowering the fan with respect the crate  more uniform flux

Conclusions The AM06 package has very low resistance: die T ~ package-PCB T. Conservative simulation predicts TMax AM06 die ~99o  ok Lowering the fan or using a diffusor we can have a more uniform flux of air, uniform temperature, and lower TMax We will do new cooling tests to see if the T differences between slots detected by the T-sim correspond to the observed differences We will measure the temperatures for different setups of the free space available in the rack.