PLC Millenium II Application Notes NEUSS November 2004.

Slides:



Advertisements
Similar presentations
Wall Mounted J series Troubleshooting.
Advertisements

Chapter 3. HVAC Delivery Systems
IGCSE ICT Control Systems.
Styrteknik: Tidskretsar, räknare PLC4C:1 Övningar med timer(counter.
Operating Functions.
Programming with Ladder Logic
Daikin Altherma™ Troubling Shooting
Freezer Alarm &Backup Systems Preventing Sample Losses * * * * * * * * * * * * * * * * * * * * * * * * Joe DeFrancesco, Gina Koskela, Peter Sturman Oregon.
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
In this presentation you will:
Special Applications Timed shut-off function Intelsteer Power Saver.
ComfortLink II / AccuLink Zoning
Linkage Connecting system components. Allows configuring automatic actions Triggering outputs based on specific inputs Used for removing human reliance.
Lecture 7: PLC: Review Questions
PLC Fundamentals Module 2: Hardware and Terminology.
Conveyor Control using PLC, VFD, and Sensor
1 Air Conditioning Pressure Switches. 2 High Pressure switch Used to protect the compressor When condensing temp gets too high Reads High Side Pressure.
Index Sr No. Description Slide no. 1
Energy Conservation Western North Carolina Recycler’s Networking Council Black Mountain, North Carolina December 9, 2004 Keyes McGee, E.I. North Carolina.
PLC introduction1 Discrete Event Control Concept Representation DEC controller design DEC controller implementation.
PLC: Programmable Logical Controller
March ) Pretreatment Tank 2) Aeration Chamber 3) Clarifier Chamber 4) Chlorinator 5) Holding Tank 6) Aerator Pump 7) Millenium Control Center 8)
Managing Energy Consumption ENERGY SAVING IS ONLY GOOD IF IT SAVES YOU MONEY. ENERGY SAVING IS BETTER IF IT MAKES YOU MONEY.
INDUSTRIAL ELECTRONICS CONTROL EET425/4 Lecturers Indra Nisja School of Electrical System Engineering Northern Malaysia University College of Engineering.
S e c u r i t y L i g h t E a s t e r E l e c t r o n i c s P r o j e c t Dark Sensor Comparator Monostable Counter Light Brief Design a system that turns.
Air Conditioning Heating Refrigeration
Air Handler Terminology
Looking at systems. What is a SYSTEM? The radiator makes the room warmer by turning ON when the temperature of the room is lower than required The THERMOSTAT.
Air Handler Terminology
Control Technology and Automation
Build a track for the ‘train’ to go back and forth across. It should switch directions after a set amount of time.
Continue FCU150 Trash Compactor. Normal ModeDelay Mode.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
1. 2 INDEX MAIN DISPLAYS3-4 SYSTEM LAYOUT 5-6 ROOM P-109 DISPLAY7 ROOM P-108 DISPLAY8 ROOM P-107 DISPLAY 9 ROOM P-106 DISPLAY 10 ROOM P-105 DISPLAY 11.
4) Design the logic to control the motor on a simple remote control car. There are two buttons on the remote control for the motor. If neither button is.
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
Discrete Control Logic
shift to the Test Mode (Forced Operation).
MACHINE OPERATION.
Automotive Heating And Air Conditioning
Louisiana State University Radiation Safety Office
Building Automation System
LG PLC COURSE Beginner Prepared by : -Hossam Mohammed -Ramdan said
Conveyor Belt Production Line
Blower-/Fan Coil-Actuator
PLC: Programmable Logical Controller
Digital electronics and logic gates
UV Startup Procedure.
IM, Presence, and Contacts
fischertechnik® RoboPro Software for Gateway To Technology® RoboPro
Programming Timers.
Engineering Presentation
Loop Water Controller Overview
Training Course SuperCool 1000 Level 1
Input > Process > Output
Input-Output-Process Demo
Systems and Control.
ACOE347 – Data Acquisition and Automation Systems
How electronic systems work using the Systems approach.
Universal Interrupted Electronic Oil Primary R7184U Training Module
2. ATP INITIALIZATION PLACE ATP SWITCH TO “1” OR “NORMAL” POSITION A
BOILER PROTECTION AND INTERLOCKS
Confidential Oilfree Scroll Compressor   Simplex/Multiplex SRL kW   Troubleshooting Hitachi Industrial Equipment Systems Co., Ltd. Air Compressor.
‘‘ BUILDING AUTOMATION’’
Systems and Control.
Dash Warning Lights and Driver Information Systems
Presentation transcript:

PLC Millenium II Application Notes NEUSS November 2004

Waste Water Filtration System Millenium used to monitor floats, turn on pumps, and control alarms in septic systems. 1) Pretreatment Tank 2) Aeration Chamber 3) Clarifier Chamber 4) Chlorinator 5) Holding Tank 6) Aerator Pump 7) Millenium Control Center 8) Discharge Pump

Waste Water Program

Landscape Irrigation & Water Fountain Controller The Millenium monitors float switches, turns on pumps, provides time-of-day control for fountain operation, monitors wind speed on outside fountains, and controls fountain lighting

Irrigation and Fountain Program

Packaging Equipment The Millenium controls feeder mechanisms, monitors temperature, controls sealing devices, and maintains count of products being sealed and total sealed packages

Millennium 2 monitors bag sensing and indexing, the blower to inflate bags, the sealing bar, counts and displays the number of operations. Bag indexing is adjustable to the size of the bag. A bag rolled out on the plan. A blower is then turned on to inflate the bag so pieces can be dropped into it. Once the bag is full, a sealing bar tilts down seals the the top of it. If an object interferes while the bar is tilting down switches will sense it a forbid the complete tilting.

Conveyors The Millenium controls motors, counts product, detects belt jams (alarm condition), controls sorters, provides time-of-day start/stop schedule, controls lubricating system

Conveyor Program

Dock Leveler The Millenium monitors the up/down control buttons, detects the upper/lower limits, controls the dock-lip, provides automatic time-out, provides status/error messages

Dock Leveler Program

Access Control & Security The Millenium monitors card reader or key pad, controls locking mechanisms, controls motor for door/gate/barrier, monitors limit switches, monitors access time, controls status lights

Security Gate Program

HVAC & Refrigeration The Millenium monitors indoor/outdoor temperatures, measures humidity, controls compressors, blowers, dampers, and fans, controls lighting relative to ambient and/or time-of-day

HVAC&R Program

Lighting The Millenium controls indoor lighting based on time-of-day, and/or outdoor lighting based on ambient light levels

Interior lighting will be controlled via a time switch function block programmed to normal business hours. Gas Pump Lighting will be controlled via the interior lighting time switch and a photo-sensor. The time switch will give a signal during normal business hours. The photo-sensor will give a signal indicating darkness. An AND function block will take both the signals and turn on the appropriate output. Sign Lighting will be controlled via the photo-sensor. During all dark hours the sign will be lit. A switch will be provided to operate sign lights only during dark business hours. A motion sensor in the stock room will be monitored to only turn on lights when an employee has entered the room.

Trash Compactors The Millenium monitors the start button, powers the motors, monitors limit switches, provides timing function, and controls lighting indicators and alarms

When the start button is pushed , an alarm (O3) will sound for 3 seconds. The motor (O1) will then start. If the auxiliary contacts are not activated within a short set time, it will trigger the light O2 signaling something wrong. The timers are set back to initial value and are ready for the next cycle. An emergency stops button is wired to Input 4 and would stop the process if pressed.