Anaesthesia for healthy patient

Slides:



Advertisements
Similar presentations
Safety Requirements of the Anesthesia Workstation
Advertisements

INTERMEDIATE PRESSURE SYSTEM PRESENTED BY: Dr CHITTRA MODERATED BY: Dr JYOTI PATHANIA.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 1 of 4.
Anesthesia Apparatus Checkout Recommendations
Regulators and Flowmeters
MODULE 5 1/26 Case 6: Anthony. MODULE 5 Case 6: Anthony 2/26 Patient History  Anthony is a 55-year old lawyer.  He has been suffering from voiding complaints.
Anesthetic Equipment.
 The annular space. The clearance between the head of the float and the flow tube is known as the annular space.
Periodic Health Evaluations Components, Procedures, and Why They Could Save Your Life!!!
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
PART 3: Breathing Circuit
The Respiratory System By: Rebecca Bicknese CMA Review MA 230 Tuesday Night Class.
Obstructive Sleep Apnea in Children
Flow Meters Flow: Volume of a fluid passing certain point over a given time Flow Rate. over a given time Flow Rate. Flow meters:sets used to measure flow.
Parts of the Anesthetic Machine
Products Training.
Orotracheal intubation เพชรรัตน์ วิสุทธิเมธีกร, พบ., ว. ว. ( วิสัญญี ) ภาควิชาวิสัญญีวิทยา วิทยาลัยแพทยศาสตร์ กรุงเทพมหานครและวชิรพยาบาล.
+ Surgical Procedures 7.01 Implement techniques to prepare and monitor patients for surgery.
Preoperative assessment
Introductory Lecture Series: The Anesthesia Machine
Intubation and Anatomy of the Airway
Difficult Airway. Definition The clinical situation in which a conventionally trained anesthesiologist experiences difficulty with mask ventilation, difficulty.
Medical Grand Rounds Clinical Vignette March 11, 2009 By Melissa Price, M.D.
Maintaining Oxygenation Phase 2 Medical Students Respiratory System A. J. Shearer Consultant Anaesthetics & Intensive Care.
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
a) Obtain a full history and physical examination including allergies, current medications, past anesthetic history, family anesthetic history b) The.
Problem Based Learning Anesthesia for the “Healthy” Patient A 52-year-old man has had progressive knee pain with swelling, and a Baker cyst just behind.
Click on the doctor bag to move to the next page.
Dr.Moallemy PREOPERATIVE EVALUATION AND MEDICATION AND RISK ASSESMENT Abas Moallemy,MD Assistant professor of Anesthesiology,Fellowship of pain,Hormozgan.
Non-communicable Disease Coronary Heart Disease
Pre-Operative and Post-Operative Care
HYDRAULICS & PNEUMATICS
Sleep Apnea Maki Morimoto, MD.
The Postanesthesia Care Unit Ahmad abu assa. PACU Recovery from anesthesia can range from completely uncomplicated to life-threatening. Must be managed.
Paramedic Ventilator Management
Coronary Heart Disease (CHD) Grade 8, Semester 1 Year
Pre and Post-Operative Nursing Care
Case 10-Anesthesia for healthy patient
Universal Anaesthesia Machine (UAM) – functional testing of a new anaesthesia workstation for use in the developing world De Beer DAH, Walker IA, ♦ Bell.
Pre-operative A ssessment Dr Gazi YILDIRIM. Goals of preoperative assessment History and physical examination to determine relevant tests and consultations.
Introductory Lecture Series: The Anesthesia Machine
CW Chapter 1: Assessing the Patient’s Health Course Work 107.
Welcome to Anaesthesia! Dr Basil Almahdi Consultant Anaesthetist.
GENERAL ANAESTHESIA Katarina ZadrazilovaFN Brno, Nov 2010.
and Altered Mental Status
Chapter 26, lesson 3 objective:
Oxygen Course.
EMT-B County Skill Patient Assessment (Medical) 30 points
MAKING HEALTH CARE SAFE ENGINEERING AND SAFE ANAESTHESIA
Piped gas supply Description
Aishah Awatif Haziq Pre-operative evaluation and preparation (prior to procedure under general anesthesia)
Pre-operative Assessment and Intra operative Nursing Role
Chapter 27 Perioperative Care
Cadiopulmonary resuscitation
Postoperative Hypotension
Post-operative Pain Management
Anaesthasia For Healthy Patient group C
Pressure Regulator, Pressure Gauge, Flowmeters
Chronic Diseases Chapter 23.
Introduction to ventilation
Non-Rebreathing System
Sophie Young 21st February 2007
Heart Lung Machine Lecture (9).
The Anaesthesia Machine
TEMS Regional Difficult Airway Course
Dip. Software based statistics PhD ( physiology), FICA , IDRA
Pressure regulators (reducing valves)
Chapter 4 Cough or difficult breathing Case I
Presentation transcript:

Anaesthesia for healthy patient Group C

Case scenario A 52-year- old man has history of progressive knee pain with swelling, his orthopaedic surgeon tentatively diagnosed him as a torn meniscus, and recommended an arthroscopy as an outpatient. The patient has had no major illnesses other than the typical childhood diseases. He has had no previous operations or anaesthetics, nor a family history of problems with anaesthesia. He no allergic history to medications, does not smoke, diabetics on oral medication blood sugar is controlled .

Cont. scenario His laboratory results and physical examination by an internist were all normal. He has had nothing to eat or drink since he went to bed last night. On examination, the patient weight was 75 Kg and height 182 Cm. His neck appears to be flexible and mobile. He opens his mouth without difficulty, and with his head extended and tongue protruding, his uvula is completely visible.

Q1. What is the patient’s general medical condition and ASA standard classifications?

This patient has a mild systemic disease (well controlled diabetes), for that his ASA standard classifications is ASA grade II.

ASA classification

Q2. Discuss the airway assessment for this patient?

The majority of assessments relate to the ease or difficulty of this process. Assess by history and physical examination (LEMON approach)

History Ask about: • Past anaesthetic history – see old notes, Medic Alert bracelet; • Surgery/radiotherapy to head and neck; • Obstructive sleep apnoea (OSA). • Conditions affecting: Tongue size (e.g. acromegaly, infections, tumors); Neck mobility (e.g. ankylosing spondylitis, infections, tumors); Mouth opening (e.g. temporamandibular joint dysfunction).

Physical exam On general exam: LEMON law Look externally. Evaluate the 3-3 rule. Three fingers of mouth opening Three fingers between mentum and hyoid Mallampati Score. Obstruction /Obesity. Neck mobility. CT/MRI.

Mallampati classification

Airway assessment for this patient Hx  No previous surgeries, or anesthetics. No family history of anesthetic problems. No allergies. No major illnesses. Diabetic controlled by oral medication. NOT smoking. LAST MEAL was last night. Examination  Normal weight 75kg and 182cm (BMI of 22.64). Neck is flexible and mobile. Opens his mouth without difficulty. He had mallampati grade of 1 ( with his head is extended and protruding his tongue, his uvula is completely visible).

Q3. What is the check list for sign in in operating theatre and for time out?

Q4. Discuss anaesthesia plan for this patient

Anaesthesia plan Preoperative Management: Intraoperative Management:   Preoperative Management: Anesthetic consent Type of anesthesia Intraoperative Management: IV line Monitoring: ECG and vital signs Postoperative Management Operation details. Blood loss Analgesia given Antiemetic's given Antibiotics Thromboprophylaxis. *If the patient remain symptoms free we discharge

Q6. Discuss the safety features of anaesthesia machine before starting anaesthesia

Anaesthetic machine Provides anaesthetic gases in the desired quantities/proportions, at a safe pressure. Gas flow is set on the rotameter (O2, air, N2O) passing to the back bar. Here a proportion (splitting ratio) enters a vaporizer before returning to the main gas flow. The gas leaves the anaesthetic machine at the common gas outlet (CGO), reaching the patient via a breathing circuit.

Safety features • Non-interchangeable screw threads (NISTs) prevent the incorrect pipeline gas being connected to the machine inlet. • A pin index system is used to prevent incorrect cylinder connection. • Barotrauma to both patient and machine is avoided by using pressure reducing valves/regulators and flow restrictors. • The oxygen failure warning alarm is pressure driven and alerts of imminent pipeline or cylinder failure. • Accurate gas delivery: flow delivered through the anaesthetic machine is displayed by a bobbin within a rotameter. The gas enters the cylinder at its base, forcing the bobbin higher, depending on the gas flow. This is a fixed pressure variable orifice flowmeter, that is the pressure difference across the bobbin remains constant whilst the orifice size increases further up the tapered tube. Each rotameter is calibrated for a specific gas as their viscosity (at low, laminar flow) and density (at higher, turbulent flow) affect the height of the bobbin. The bobbins have spiral grooves which cause them to rotate in the gas flow. An antistatic coating prevents the bobbin sticking. Modern anaesthetic machines give a digital representation.

• Hypoxic guard: the O2 and N2O control knobs are linked, preventing <25% O2 being delivered when N2O is used. Oxygen is delivered distal to N2O within the rotameter, preventing hypoxic gas delivery if the O2 rotameter is faulty or cracked. • Interlocking vaporizers on the back bar prevent two anaesthetic vapours being given simultaneously. • Ventilator alarms warn of high and low pressure. • Emergency oxygen flush: when pressed, oxygen bypasses the back bar and is delivered to the CGO at >35L/min. This must be used with caution as gas is delivered at 4 bar and does not contain anaesthetic. • Suction: adjustable negative-pressure-generated suction is used to clear airway secretions/vomit and must be available for all cases. • Scavenging of vented anaesthetic gases is active, passive or a combination. Scavenged gases are usually vented to the atmosphere. Scavenging tubing has a wider bore (30mm), preventing accidental connection to breathing circuits. Low gas flows reduce environmental impact and cost. Operating theatre air exchange occurs through the air conditioning system (e.g. 15 times per hour). The main aim is infection control; it also serves to remove unscavenged gases.