Corrosion under insulation (CUI)

Slides:



Advertisements
Similar presentations
AMMONIA SYSTEM INSTALLATION EXAMPLE ON OPERATING SYSTEM USING:
Advertisements

Welcome The objective is to provide the best recommendation to diminish the possibility of corrosion at the metal and insulation interface. Explanation.
Single Coat 100% Solids Tank Linings SPECIALTY POLYMER COATINGS, INC. Single Coat 100% Solids Tank Linings.
Bridge Corrosion A look at the corrosion of steel in Bridges.
Above Ground Storage Tanks &
Corrosion under insulation (CUI)
Roofing Barrier System AC100 RF Best Coat  SCS Coatings, LLC 8 Timberbrooke Drive, Hopewell, NJ
DISTRIBUTED BY. A non-toxic, Planet Friendly solution for soil remediation  Proven effective in the field with documented test results Environmental.
Fuel cells differ from batteries in that the former do not store chemical energy. Reactants must be constantly resupplied and products must be constantly.
Installing Quality Internal Tank Linings: A Perspective David Cushman West Virginia Paint LLC General Manager NACE Certified Coating Inspector #1591 Copyright.
Cost Effective Reliability Solutions Ceramic and Metallic Entrained Epoxy Coatings Representative Name:
Silvagrip The Longest Lasting Peel and Stick Non Skid.
What is Liquid Rubber? An asphalt emulsion coating engineered to provide exceptional adhesive, elastic & protective properties An asphalt emulsion coating.
Corrosion & Associated Degradation
Why Choose Vinyl? See the benefits of energy-efficient vinyl windows and doors in many different applications.
Physical Science Applications in Agriculture Unit Physical Science Systems.
Corrosion of Metals.
InsulCorr INSULCORRTM is a high build single component multi polymer acrylic resin matrix coating Incorporates insulating, blocking and reflective agents.
Selecting Coatings Under Insulation Presented by: Brent W. Griffin, SME On behalf of SSPC.
Uniform or general corrosion is typified by the rusting of steel Uniform or general corrosion is typified by the rusting of steel.  Other examples.
Types of corrosion Dr. Syed Hassan Javed.
SPECTRA Products Inc. TERMIN-8R®
Cooling Systems Purpose: to keep the engine at it’s most efficient operating temperature TOO HOT! TOO COLD! - poor lubrication - excessive heat - seizing.
Aluminum Anodize By: Randall Marks. Aluminum Oxide Amorphous aluminum oxide (alumina, Al 2 O 3 ) forms in a layer 2-3 nm thick when bare aluminum is exposed.
I N D U S T R I A L P R O D U C T S A N D S E R V I C E S ARC Commercial Water The Need for Coatings in Commercial Water.
CORROSION. Rusting of iron is the commonest form of corrosion. It is the process that gradually destroys motor car bodies, steel bridges and other structures.
Corrosion types Galvanic corrosion
BUILDING CONSTRUCTION ( ) GOVERNMENT ENGINEERING COLLEGE,DAHOD CIVIL ENGINEERING DEPARTMENT PRESENTED BY: PATEL TEJASH S. ( ) GUIDE BY:
1. 2  Colors  Finishing  Technical characteristics  Materials  Applications 3.
Corrosion Under Insulation A Historical Perspective
1 DISTEK N.A LLC Introduces: A revolutionary, new environment-friendly space age rust converting paint system Moshe Moked, P.Eng. ERX TM.
Thermal Spray Coating Application
Elevated Temperature Service and Insulative Coatings
Automotive Engines Theory and Servicing
Refrigeration.
Lubrication of Circuit Breaker Mechanisms
Definition of Corrosion
Engineering Chemistry CHM 406
Processing Of The Denture (Flasking)
Materials Selection and Coatings
NEXGEN HEATING Falmer Thermal Spray Stacy M. Ames, President
Green-Lock® Membrane Adhesive as a Flood Coat
CONCRETE PROTECTION MATERIALS & TECHNIQUES
Basic Corrosion Theory
What is Rubberit? Products
Corrosion Control.
INSULATION FOR INDUSTRY AND HOUSING
Inspection of Thermal Spray Coatings
Corrosion Objectives Corrosion process Environmental factors
WATER MAIN REHABILITATION
Corrosion Control methods
Know the Methods to Remove Corrosion From Car Battery
UNDERSTANDING VINYL ESTER AND EPOXY TANK LINING PROPERTIES FOR THE POWER INDUSTRY: TIPS FOR OWNERS
Sikagard-850 AG anti-graffiti
Atmospheric Corrosion
BOILER CORROSION 11.1 DEFINITION
Definition of Corrosion
Energy saving for solid walls with Si-Dry
9.S.S POLLUTION Atmospheric contaminants, mainly salts and SO2, in combination with humidity contribute to the corrosion of most metals. Chloride ions.
Corrosion & Associated Degradation
TRENTON Casing Filler Presentation
Corrosion Part 3 Corrosion Protection Methods
Coating Failure at a Gas Compressor Facility
Electrochemistry Lesson 4
Chapter 5 Cleaning the Engine.
Prevention and Control of Corrosion
Introduction Surface Engineering By Israa Faisal
CATHODIC PROTECTION OF REINFORCED CONCRETE STRUCTURES
/700/800/900 AIRCRAFT MAINTENANCE MANUAL COLD WEATHER MAINTENANCE – SERVICING TASK
Presentation transcript:

Corrosion under insulation (CUI) The Solution for Corrosion under insulation (CUI)

Corrosion Under Insulation (CUI) CUI has been recognized as a problem in many industries Insulation is a necessary component of the system and is designed to: Save energy Control process temperatures Protect workers from high temperatures NACE Standard SP0198-2010 is a good source of information, but electrolytes will eventually find their way into even the best system

Anti-Corrosion Gel Performance Operating Temperatures – over 350° F/177 ° C Moisture Resistance – Hydrophobic Anti-Corrosion Properties – Mineralization, Inhibitors & Buffering Technology Application Surface Prep – no sandblasting, free of oils/greases Cure Time – None, visual inspection easy and non-destructive Equipment – Brush, PVC glove or spray Environmentally benign Cost Total application cost is typically lower than other systems Line shutdown not required

Technology Barrier system – The specially formulated products have great adhesion characteristics (requiring minimal surface prep) and are hydrophobic to help keep moisture away from the substrate. Never cures thus microscopic air pockets don’t form. Mineralization - Growing an engineered surface, or surface conversion – creating a surface which resists corrosion even if moisture gets to it. Undercutting cannot occur. Buffering system – If moisture migrates through the gel through vapor drive, it is buffered to a high pH which is alkaline enough not to corrode metal. Gel also contains a number of corrosion inhibitors.

How the reactive gel corrosion treatment works: When the ferrous (steel) surface (1) is covered with a layer of reactive gel (2), the metal surface reacts with components in the gel to form a mineral layer (3). This thin glasslike layer (3) acts as a barrier between chlorides and the metal surface, thus providing corrosion resistance. The mineral layer (3) has a thickness of 50-200 angstroms, only 0.01% as thick as a piece of paper.

Although the thin mineral layer can be damaged by mechanical abuse, there is extra protection built into the system, i.e.: • If the mineral surface is scratched or damaged, and there is residual gel in contact with the area, the mineral layer will be regenerated by the gel ingredients. • The gel contains a buffering agent, which raises the pH of water at the surface of the steel to 10 or above, a level unfavorable for corrosion of ferrous substrates. (Another formulation for aluminum adjusts the pH to 6-8).

Untreated steel surface Mineralized steel surface Surface Formation 10 um 10 um Untreated steel surface Mineralized steel surface

History of the Technology Automotive Technology has been used in automotive applications for > 30 years. Originates before Second World War. Crevice Corrosion on Brake Cables Industrial Applications First industrial application was with the US Navy. Solved their #1 and #2 corrosion maintenance problem. Watertight Door Latching Mechanisms Deck Edge Elevator Wire Ropes Other specific areas

2 Year Salt Water Immersion Test Samples in Aerated 5% salt solution

2 Year Salt Water Immersion Test Samples in Aerated 5% salt solution

2 Year Salt Water Immersion Test Non-Bead Blasted Pipe Bead Blasted Pipe

Stress Crack Corrosion on SS Control Sample Typical Stress Cracking with in 100 hours of exposure Per ASTM C 692 EDC 2400 Treated Sample No Cracking after 100 Hours Exposure Per ASTM C 692 Gel Treated Sample No Cracking After 100 Hours Exposure Per ASTM C-692

Anti-Seize

Ammonia Lines Ammonia Test Site Flange Remediation

North Slope

AMMONIA SYSTEM INSTALLATION EXAMPLE ON OPERATING SYSTEM USING:

PICTORAL INSTALLATION REMOVING METAL JACKET

PRIMER ON INSULATION CORROSION ON PIPE

REMAINING PRIMER EASILY REMOVED

Pipe temperature thickens the RG-2400 LT quickly Pipe temperature thickens the RG-2400 LT quickly. After 3 passes over an area it gets difficult to spread and achieve adhesion. The slight frost on the pipe left some voids, however fresh “warm” material could be put over these areas and achieve ahesion. INSTALLING RG-2400 LT

A WELL COATED PIPE READY FOR INSULATION

CONCLUSIONS COATING A 24° PIPE IN OPERATION IS POSSIBLE IN SMALL SECTIONS. RG-2400 MUST BE WARM TO IMPROVE COVERAGE AND EASE OF APPLICATION INSULATION MUST BE INSTALLED IMMEDIATELY UPON ACHIEVING COVERAGE TO PREVENT CONDENSATION FROM FORMING ON THE RG-2400 INSULRAP OR FABWRAP VAPOR BARRIER SHOULD BE USED TO KEEP OUT MOISTURE TESTING WILL CONTINUE ON -15° F LINES IN OPERATION AND -50° F LINES IN OPERATION. RESULTS WILL BE ADDED TO THIS PPT PRESENTATION. GLYCOL WILL BE TESTED TO REMOVE FROST ON THE COLDER LINES.

Product Application - Tank The tank was completely sprayed in approximately one hour

Tank Chime Application – Texas City, Texas

Conoco/Phillips Well Casing WELLS WERE FIRST FLUSHED WITH 55 BARRELS OF 120° F CLEAN WATER TO REMOVE SLUDGE, WATER WAS PUMPED OUT AT END OF FLUSH CYCLE.

Companies With Product Installations/specifications Anheuser Busch General Mills Jolly Green Giant British Petroleum Best Brands Foods Philadelphia Gas Fred Meyer Foods Unocal Dot Foods Exxon Mobil CODELCO Tuborg Efes Pilsen GlaxoSmithKline Shell OxyChem Ernst & Gallo Equistar Union Carbide Cytec Phillips MODOT Nicor Monarch Foods US Navy Kraft Foods ConocoPhillips Coors Brewing Canada Hydro Indiana University

Benefits of the Technology: Practical application – simple non-curing gel Multiple delivery systems (spray, glove, brush) Insensitive to surface preparation and application conditions Demonstrated superior anti-corrosion performance Environmentally benign Easy to inspect