Coating Characteristics:

Slides:



Advertisements
Similar presentations
Wilko Paint, Inc. Wilko Paint is the premier supplier of industrial finishes and coatings.   Our staff of industrial coatings specialists will provide.
Advertisements

Single Coat 100% Solids Tank Linings SPECIALTY POLYMER COATINGS, INC. Single Coat 100% Solids Tank Linings.
DECORATIVE SINGLE COAT PLASTER FOR MARBLE CHIPS CLADDING SYSTEM ( PEBBLEDASH )
Selecting the Proper Coating/Lining System
CLEANING AND PAINTING OF STRUCTURAL STEEL THE BASICS
Calculating Coating Lifetime Costs
Polymer Floor & Wall Coatings: Selection, Preparation, Installation and Troubleshooting.
SYNTHETIC RED OXIDE METAL PRIMER It has good anti-corrosive properties. It contains Zinc-chrome. Recommended for agricultural, steel structures & other.
SIGMASHIELD 880.
63 Daraya Rd, Blacktown NSW 2148| Phone: | WEAR RESISTANT CERAMIC COATING Product Description.
Liquid Rubber is the world’s only EPDM rubber in liquid form. Liquid Rubber provides a seamless, single coat roof coating that can be applied up to 6.
Customer presentation, March 2007 Penguard Express Speeding up the production process.
COATINGS FOR STEEL & CONCRETE
Busting The Myths of Wet Abrasive Blasting
2313 W Sam Houston Parkway NSuite 105Houston, TX77043 (T): (F): ROK Flex C Application Instructions.
Asset Management Preservation
2313 W Sam Houston Parkway NSuite 105Houston, TX77043 (T): (F): ROK FLEX M Application Instructions.
AUZIE QUIC SLIP PTY LTD AQS METAL PRO – 001 INTERIOR AND EXTERIOR.
New Water-Based Amine Technology for Epoxy Application Over Green Concrete
 Single Component Products TT-P-1952E - Waterborne traffic paint TT-P-1952E - Waterborne traffic paint A-A-2886A - Solvent traffic paint A-A-2886A - Solvent.
Wind Turbines: Challenges Associated with Corrosion Protection
Presented by: Peter Emmons,
Polyurea Technology Overview
InsulCorr INSULCORRTM is a high build single component multi polymer acrylic resin matrix coating Incorporates insulating, blocking and reflective agents.
BondChem TECHNICAL DATA Roll-a-crete ( Three Component Cementitious Waterproof Coating ) Page 1 / 2. DESCRIPTION BondChem’s Roll-a-crete is a three component.
Hydro-Flex PIR Heat Reflective Polyurethane Topcoat Visit Us Toll Free:
Presented by: Tony Serdenes, Greenman-Pedersen
SIGMACOVER 240. All climates - No winter-grade or tropical versions All industries All substrates All surface preparation standards All specification.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Application of Thermal Spray
Standards, Training, and Certification in the Wastewater Industry Presented by: Bob Murphy, Sherwin Williams.
Advances in Polyurethane and Polyurea Technology Presented by: Jayson L. Helsel, P.E. KTA-Tator, Inc.
BILBOND H 4545 Formerly Bhavi International Ltd.
Joining Techniques To understand which adhesive(s) is the most suitable for joining like and unlike materials To understand the advantages and disadvantages.
Patented Technology – Quality Results Ulti-Pave 3 Pavement Repair Mix 30-Minute Workability 3,000 PSI 3-Hour Set ® “A One Component, Rapid Hardening Cementitious.
Epoxy Infusion System – Hardener SIN B17 Polynt’s SIN B17 is the world’s first Epoxy resin hardener based on anhydride chemistrythat has been specially.
1 DISTEK N.A LLC Introduces: A revolutionary, new environment-friendly space age rust converting paint system Moshe Moked, P.Eng. ERX TM.
Flammable Liquids Directorate of Training and Education
Advances in Thermal Insulative Coatings Due to Two Component Technology MESC 2016 Dubai.
2016 SUBSTRATE PREPARATIONS. SUBSTRATE PREPARATION METHODS FOR CONCRETE Very Course Profile Scabbling – Suitable for very aged, weak or contaminated substrates.
THE SCIENCE OF SOLVENT WELDING
Performance Properties Water Vapor Permeability
Corrosion Basics Chapter 6 – NACE Book Protective Coatings
Concrete Repair.
Beyem Fir White Enhanced cement based tile adhesive for interior use
Numix Car Refinish.
ERA Industries, LLC. Texlub Universal Oil 2T 2-CYCLE ENGINE OIL
Garland’s Rust-Go System
High Density Polyethylene (HDPE) Panels or Sheets
Materials Selection and Coatings
How to Select and Optimize Abrasive Blasting Equipment
Intumescent Steel Coating
Using Stains, Paints, and Other Finishes
PVCu SPRAYING.
Inspection of Thermal Spray Coatings
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
SURFACE PREPARATION BY BLAST-CLEANING
NACE SPECIFICATION White Metal Blast Cleaning
Industrial Choice® 1600 System Multi-purpose Aerosol
Corrosion Control methods
UNDERSTANDING VINYL ESTER AND EPOXY TANK LINING PROPERTIES FOR THE POWER INDUSTRY: TIPS FOR OWNERS
Sikagard-850 AG anti-graffiti
Novel Toughening Technology for Epoxy Thermosets Steve Hoyles, Nikhil Verghese, Michael Ross, Marv Dettloff and Ha Pham The Dow Chemical Company 11/22/2018.
The Importance of Specification Writing
Metal Finishes.
Influence of properties of coarse aggregate
NATE Tower Site Hazard Recognition Guide
3M™ Universal Cover Tape (UCT) 2688A application procedure
NSRP Joint Project SP&C and WD Panels Robert Cloutier
Elixir-lndia Your Solutions Partner Engineering Adhesives - Threadlockers - Loxeal Description Elixir-India is your true sourcing partner from around.
Presentation transcript:

Coating Characteristics: ForSField™ SG-11 Protective Coating Product Description ForSField™ SG-11 protective coating is a surface tolerant, zero VOC, HAPs free, direct to metal (DTM), multipurpose, two part protective coating designed for spray applications. It has excellent adhesion to metal, concrete, and galvanized substrates. Its main purpose is to protect substrates from corrosion and impart superior chemical resistance. Can be used as a primer, tie coat, top coat, and for chemical immersion service. It is available in gray. Features Free of VOCs, HAPs, and solvents Convenient 1:1 volumetric mix ratio Self priming and surface tolerant Bio-content is 26% by weight Exceptional resistance to acids, bases, and chemicals Excellent adhesion to steel, galvanized steel, and concrete substrates Resists corrosion Dry Film Thickness and Coverage 11-15 mils (+/- 2 mils) DFT recommended for atmospheric service 15-25 mils (+/- 5 mils) DFT recommended for immersion service 50 mils DFT Maximum Up to 20 mils maximum per pass (to prevent sagging) Theoretical coverage of 123 ft2/gal @ 13 mils Theoretical coverage of 80 ft2/gal @ 20 mils Intended Uses For use as a medium to high-build epoxy coating to enhance corrosion and chemical resistance in a range of environments including petrochemical plants, mining facilities, pulp and paper mills, chemical process plants, and offshore structures. It can be used as a primer or a top coat. Recommended film builds are 11-15 mils for most applications and 15-25 mils for immersion applications. It can be used over tightly adhering rust to encapsulate it and prevent further corrosion. This coating is suitable for both maintenance and new construction applications. Surface Preparation ForSField™ SG-11 protective coating is a surface tolerant coating so it is able to maximize adhesion to substrates that are not perfectly prepared and encapsulates existing rust. This is very useful for maintenance applications were perfect surface preparation might be very difficult to achieve. Since this coating shows excellent adhesion to tightly adhering rust it can be used under these non-ideal conditions. A lower degree of surface preparation will affect adhesion to the surface. The surface to be coated should be clean and dry. Utilize sufficient methods to eliminate excess debris, scale, rust, water, or oil that may interfere with coating adhesion. It is recommended to wipe clean all metal surfaces with a solvent such as methyl ethyl ketone (MEK) after surface preparation and before coating application. For best results the following surface preparation is recommended. Steel For optimal results prepare the surface in accordance with SSPC-SP 5 / NACE 1 / Sa. 3 / BS4232 First Quality / 31 GP 404 Type 1 / JASh3 or JASd3, white metal blast cleaning for atmospheric and immersion service. An anchor profile of 3-4 mils is recommended. As an alternative prepare the surface in accordance with SSPC-SP 6 / NACE 3 / Sa. 2 / BS4232 Third Quality / 31 GP 404 Type 2 / JASh 1 or JASd 1, commercial blast cleaning for atmospheric service. A minimum anchor profile of 1.5 mils is recommended. Can be applied over galvanized steel after surface preparation in accordance to SSPC-SP 1 solvent cleaning with MEK. Concrete Concrete surfaces should be fully cured, cleaned and degreased. For optimal adhesion performance acid etching is recommended by using muriatic acid or a similar product. Previously Painted Surfaces ForSField™ SG-11 protective coating can be applied over most coatings in sound condition but compatibility needs to be tested beforehand. We recommend to sand or abrade to roughen and de-gloss the surface. Then solvent wipe the surface with MEK. Ensure the surface is dry and free from excess dust or debris before applying this coating. Performance Data All of the data presented are reported from tests performed on coatings applied under controlled laboratory conditions and may not represent exact data achieved in field applications. Coating Characteristics: Typical Value: Units: Method: Viscosity (2 Part Mixture @ 73ºF / 23ºC) 16,000 cP D2196-10 (#7 SP, 50 rpm) Pull-Off Adhesion (Carbon Steel, White Metal Blast) 3,900- 5,000 psi PATTI® F-16 Piston Pull-Off Adhesion (Smooth Concrete) 800 Pull-Off Adhesion (Galvanized Steel) 2,700 Taber Abrasion (CS-17 @ 1,000g Load, 1,000 Cycles) 91 mg ASTM D4060-10 Impact Resistance @ 25ºC 40 in-lb ASTM D2794-93 Chevron Phillips Chemical Specialty Chemicals Division 10001 Six Pines Drive The Woodlands, TX 77380 U.S., Canada & Latin America: 1-800-858-4327 Europe, Africa & Middle East: +32 (0) 2 689 12 11 Asia Pacific: +65-6517 3100 sc@cpchem.com

Adhesion to Carbon Steel (PATTI® F-16 Piston) Surface Preparation: Adhesion Typical Value: SSPC SP5 / NACE 1 – White Metal Blast 4,600 psi SSPC SP5 / NACE 1 – White Metal Blast with Flash Rust 2,000 psi SSPC SP7 / NACE 4 - Brush Off Blast with Significant Rust 1,700 psi SSPC SP1 – Solvent Wipe (Significant Rust) 2,500 psi SSPC SP3 – Power Tool Cleaning 3,900 psi Galvanized Steel 2,700 psi Application Listed below are general guidelines for the application of the ForSField™ SG-11. Specific project conditions may require modifications to these guidelines to achieve the desired results. Ensure the ambient temperature, unmixed product components and surface to be coated are above 55°F (13°C). Both components should be no warmer than 130°F (54°C) at the time of spray application. Best results are achieved with a relative humidity of 60% or less and a surface temperature of at least 5°F (3°C) above the dew point. Mixing and Spray Application Mix ratio is 1:1 by volume Thinning is not recommended Plural component airless spray equipment capable of heating coating to 130ºF and provide in line pressures of 4,500 psi at the tip Re-use of SG-11H hardener is not recommended and opened containers should be discarded at the end of the day Recommended clean-up solvent is MEK HEAT WARNING! Curing epoxy generates significant heat. Never hand mix the ForSField™ SG-11R epoxy resin with the ForSField™ SG-11H hardener. Doing so will generate significant heat and the combined materials may reach temperatures which can cause severe burns to skin, melt plastic and foam, and ignite combustible materials (potentially as much as 300°F or higher). Do not mix the epoxy resin with the hardener in containers made of materials such as plastic, foam or glass. If a container of mixed epoxy resin and hardener starts to exotherm (heat up) take precautions to move the container to a safe location. For industrial/commercial use.  Application must be performed by trained personnel only using an appropriate plural component sprayer. Adhesion to Concrete (PATTI® F-16 Piston) Surface Preparation: Adhesion Typical Value: Concrete - Smooth 800 psi Concrete – Trowel Finished 600 psi Concrete – Trowel Finished and Acid Etched 900 psi Concrete – Paver with Porous Finish 1,200 psi Curing Schedule Top-Coats Can be top-coated but compatibility would need to be tested beforehand Allow 7 hours after applying final coat, before top-coating with other coatings If the coating is older than five days, wipe surface down with MEK before top-coating Shelf Life Information We recommend storage at a controlled temperature of 25ºC. Shelf life of the ForSField™ SG-11R Resin is 2 years in original unopened container. Shelf life of the ForSField™ SG-11H Hardener is 2 years in original unopened container. Packaging The ForSField™ SG-11 Protective Coating is available in pail (4 gallons), and drum (50 gallons) quantities. Product Density Density for the ForSField™ SG-11R Resin is 12.10 lbs/gal. Density for the ForSField™ SG-11H Hardener is 8.20 lbs/gal. Product Safety Information Material Safety Data sheets are available upon request and on our website at: http://www.cpchem.com/specialtychemicals For more information on ForSField™ Protective Coatings, view our product information online at: http://www.cpchem.com/bl/specchem/en-us/Pages/default.aspx Curing Schedule* Surface Temperature Dry-to-Touch: Tack-Free: Full Cure for Atmospheric Service: 68°F (20°C) 110 mins 5.5 hours 48 hours   * Curing times will vary with temperature, humidity, and other application conditions. Before using this product, the user is advised and cautioned to make its own determination and assessment of the safety and suitability of the product for the product for the specific use in question and is further advised against relying on the information contained herein as it may relate to any specific use or application. It is the ultimate responsibility of the user to ensure that the product is suited and the information is applicable to the user’s specific application. Chevron Phillips Chemical Company LP does not make, and expressly disclaims, all warranties, including warranties of merchantability or fitness for a particular purpose, regardless of whether oral or written, express or implied, or allegedly arising from any usage of any trade or from any course of dealing in connection with the use of the information contained herein or the product itself. The user expressly assumes all risk and liability, whether based in contract, tort or otherwise, in connection with the use of the information contained herein or the product itself. Further, information contained herein is given without reference to any intellectual property issues, as well as federal, state or local laws which may be encountered in the use thereof. Such questions should be investigated by the user. Version 1.2, November 2016 Chevron Phillips Chemical Specialty Chemicals Division 10001 Six Pines Drive The Woodlands, TX 77380 U.S., Canada & Latin America: 1-800-858-4327 Europe, Africa & Middle East: +32 (0) 2 689 12 11 Asia Pacific: +65-6517 3100 sc@cpchem.com