Epidemiology and refractive determination of astigmatism at near sight

Slides:



Advertisements
Similar presentations
Keratoconus Research Innovation at CERA Dr Srujana Sahebjada Research Fellow, Optometrist Ocular Genetics Unit.
Advertisements

Introduction to Refractive Error and Prescription Writing Walter Huang, OD Yuanpei University Department of Optometry.
Straylight (disability glare) results in case of a diffractive multifocal IOL design with apodization pattern adjusted to reduce glare. Ruth Lapid-Gortzak.
Pooja B. Jamnadas, MD, Peter Russo, OD, William Bonk, Shuchi Patel, MD Loyola University Chicago, Stritch School of Medicine, Department of Ophthalmology,
Pooja B. Jamnadas MD, Marie Brenner, MS4, Peter Russo, OD, Shuchi Patel MD Loyola University Medical Center, Department of Ophthalmology, Maywood IL At.
Correlation Of Corneal Contour With Higher Order Ocular Aberrations (HOA) In Indian Eyes Manish Chaudhary MS Amit Gupta MS Advanced Eye Centre, Postgraduate.
Introduction to ophthalmology
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Walter Huang, OD Yuanpei University Department of Optometry
INTRAOPERATIVE FLAP COMPLICATIONS IN LASIK SURGERY PERFORMED BY OPHTHALMOLOGY RESIDENTS IN TRAINING Arturo Gómez-Bastar MD Arturo Ramirez-MirandaMD Lorena.
Presented by Jessica M. Borges Certified Ophthalmic Technician-JCAHPO HOW DO WE SEE?
Nizar S Abdelfattah, M.D.1, Marina Israel2, Nermin Osman, M.D.3,
A Retrospective Study of the Association of Obesity and Overweight with Admission Rate within York Hospital Emergency Department for Acute Asthma Exacerbations.
Hong Kong Eye Hospital Biometry Audit 2012 SN60WF IOL Dr. Rose Chan
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
Methods The Volk Eye Check is a hand-held medical camera device with Xenon flash that captures analyses and displays, in real time, eye measurement data.
Introduction When fitting contact lenses, there are multiple measurements that should be taken to ensure the optimum design is being used. The most common.
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
A Prospective Study Examining Contact Lens Wear, Refractive Error, and Optical Coherence Tomography Retinal Nerve Fiber Layer Measurements Marie Brenner.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Rajendra Gyawali Consultant optometrist, Male’ Eye Clinic Maldives
Khairidzan Mohd Kamal MD
Predicting visual performance from wavefront quality metrics in cataract Konrad Pesudovs Katja Ullrich NH&MRC Centre for Clinical Eye Research, Flinders.
VISION.
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Nang-Hee Song(MD) 1, Jae-Woong Koh (MD/PhD) 1, Gil-Joong Yoon (MD/PhD) 2 Department of Ophthalmology, Chosun University College of Medicine, Gwangju, Republic.
AcrySof ® ReSTOR ® Aspheric IOL. Aspheric IOL AcrySof ® ReSTOR ® 2 AcrySof ® ReSTOR ® Aspheric IOL SN6AD3 Add Power: +4 D Spectacle Plane: 3.2 D Range:
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
The latest from the Australian Study of Keratoconus Dr Srujana Sahebjada Postdoctoral Research Fellow/Optometrist Ocular Genetics Unit.
Comparing Factors Affecting Surgically Induced Astigmatism
Clinical Effectiveness Of Contrast Sensitivity Function In Patients With Primary Open Angle Glaucoma (POAG) And Ocular Hypertension (OHT ) MOUSUMI SAIKIA.
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
9-Month Results after Implantation of a new accommodative IOL that works with one focus Mark Tomalla M.D.* Clinic for Refractive and Ophthalmic Surgery,
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Corneal shape and corneal aberrations after MicroIncision Cataract Surgery (MICS) NOCHEZ Y, BUREL B, MAJZOUB S, PISELLA PJ C.H.U.
Examination Techniques for Accuracy and Efficiency Astigmatism Detection and Management Options A VOSH-Florida Presentation.
Lifestyle and Refractive Factors Affecting Progressive Addition Lens Preference Padmapriya Ramamoorthy 1, James E Sheedy 2 and John Hayes 2 1 The Ohio.
Lifestyle and Refractive Factors Associated with Progressive Addition Lens Preference The Center for Ophthalmic Optics Research, The Ohio State University.
1. Ankara University School of Medicine, Department of Ophthalmology
IDENTIFYING RISK FACTORS FOR FOOD INSECURITY AT THE ZIP CODE LEVEL
Department of Ophthalmology, University of Ulsan College of Medicine,
OCULAR FINDINGS OF SCHOOL SCREENING AND EYE CAMP IN NEPAL
cross- sectional analyses of HEIJO-KYO Cohort
Suppressive effect of combined treatment of orthokeratology and 0
Field Measures of Refractive Error
Essilor Anti-Reflective Coatings Induce Haidinger’s Brushes Reversal
Done by : Mohammad Da’as Special thanks to Dana Rida and her slides 
David Marchant, Evelyn Carnegie, Paul Ellison
The authors have nothing to declare
Nienke Visser, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts
Within a Mixed-Frequency Visual Environment
Comparison of corneal powers obtained from four different devices
Testing for Independence
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
Comparison of vision with an accommodating IOL versus a multifocal IOL
Pharmacological Correction of Presbyopia: A preliminary Study
Examination Techniques for Accuracy and Efficiency
Examination Techniques for Accuracy and Efficiency
15.1 The Role of Statistics in the Research Process
Wavefront Correction of high refractive errors
versus 2.75mm Incision Phacoemulsification
Clinical Implications
Lasik decentration with the VISX ActiveTrak™ System
Lack of Confidence Interval Reporting in Dermatology: A Call to Action
Khairidzan Mohd Kamal MD
Pterygium and Visual Aberrations
Early Experience With Anterior Chamber Phakic IOL
Long-Term Quantitative Analysis of Posterior Capsule Opacification After Implantation of Dual-Optic Accommodating IOLs Andrea Galvis, MD 1 , 3 Ivan.
Presentation transcript:

Epidemiology and refractive determination of astigmatism at near sight C. Anders, B.Sc. 1; O. Kolbe, B.Sc.1; Prof. Dr. S. Degle1 1University of Applied Sciences Jena, Germany Introduction: Results: A connection between the subjectively measured amount of near astigmatism and pupil decentration (t-test, p=0.002) was found Increasing visual requirements at close range and the establishment of advanced lens manufacturing technologies have led to a new focus on the issue of near astigmatism. The phenomenon of astigmatism at near sight has been discussed controversially in the past 15 years1-7. Subjective Near Astigmatism 43% of the subjects showed an amount of near astigmatism of at least 0.125 D 42% showed a change in axis axis change of at least 3°. In the group with a pupil decentration of ≥0.24 mm the amount of near astigmatism is significantly higher than in the group with a decentration of <0.24 mm (see Fig. 4) Purpose: This study investigated the prevalence of astigmatism with accommodation and the comparability of subjective and objective results. It is to determine whether and how the maximum amplitude of accommodation (MAA), the amount of distance astigmatism (DA) and pupil decentration affect near astigmatism. Furthermore, the reliability of a specially developed screening figure was tested. Figure 4: Correlation of subjective amount of near astigmatism and decentration of the pupil Conclusion: Figure 2: left change in the amount of astigmatism in subjective refraction right change in the axis of astigmatism in subjective refraction (N=72) Objective Near Astigmatism 47% of the subjects showed an amount of near astigmatism of at least 0.125 D 53% showed a change in axis axis change of at least 5°. Near astigmatism is not rare but needs to be investigated concerning its impact on the visual acuity and visual perception. There is also a need to examine why subjective and objective measurements were not connected. It has to be acknowledged that there is test-retest variability in measuring astigmatism by either subjective or objective methods. To confirm the assumption that near astigmatism is caused by the crystalline lens, additional assessments of the data regarding the amount of the cylinder are necessary. Further studies can point out the representativeness of the influence of a decentrated pupil. We have to be critical of the outcomes of near astigmatism screening figures. Methods: This prospective cross-sectional study was performed at the Department of SciTec, major optometry, of the University of Applied Sciences Jena, followed the tenets of the Declaration of Helsinki. After subjects received a verbal and written explanation of the character and risks of the study, informed consent was obtained. The refraction of 72 subjects (32 males; 47 females), aged between 20 and 55 years (median 25), was measured at distance and close range. The measurements were made subjectively with a cross cylinder and objectively with an aberrometer (WASCA Analyzer G200), Carl Zeiss Meditec AG, Jena - Germany). Figure 3: left change in the amount of astigmatism in objective refraction right change in the axis of astigmatism in objective refraction (N=64) References: Correlations Subjective and objective results were not significantly correlated the change of the amount of astigmatism (r= -0.043, p=0.735) the change of axis (r=-0.204, p=0.159) There is no dependence of MMA on the near astigmatism (Kruskal-Wallis-H, p=0,145 (subjective), p=0.857 (objective)) The objective axis-change is attached to the amount of the distance astigmatism (Mann-Whitney-U, p=0.002) The group with distance astigmatism less than -0.5 D showed a significant higher change of axis than the group with -0.5 D and more There is no dependence between the results of the screening test (Figure 1) and the subjectively and objectively measured near astigmatism of at least 0.125 D (Chi-square, psub=0.538, pobj=0.807) [1] Tsukamoto, M. et al. 2000. Accommodation causes with-the-rule astigmatism in emmetropes. Optometry and vision science : official publication of the American Academy of Optometry, 77 (3). [2] Mutti, D. O., Enlow, N. L. & Mitchell, G. L. 2001. Accommodation and induced with-the-rule astigmatism in emmetropes. Optometry and vision science : official publication of the American Academy of Optometry, 78 (1) [3] Cheng, H. et al. 2004. A population study on changes in wave aberrations with accommodation. Journal of vision, 4 (4) [4] Radhakrishnan, H. & Charman, W.  2007b. Changes in astigmatism with accommodation. Ophthalmic & physiological optics : the journal  of the British College of Ophthalmic Opticians (Optometrists), 27 (3) [5] He, J. C. et al. 2003. Change in corneal shape and corneal wave-front aberrations with accommodation. Journal of vision, [6] Yang, Y., Thompson, K. & Burns, S. A. 2002. Pupil location under mesopic, photopic, and pharmacologically dilated conditions. Investigative ophthalmology & visual science, 43 (7). [7] Lemm, D. et al. 2010. Aberrationen höherer Ordnung bei Blickbewegungen. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 107 (8) Furthermore, a novel ray figure was developed and used to screen for astigmatic change in close range. It consists of 36 concentric arranged lines, in equal gaps of 10 degrees and two small central rings with different line widths, based on the Verhoeff Circles, see Figure. 1. The clinical designation of astigmatism (cylinder power and axis) was converted to power vectors, the near astigmatism Figure 1: Novel ray figure for the subjective measurement of the astigmatism at near sight astigmatism calculated using the change in the J180 and J45 vectors, and afterwards reconverted to determine a change in cylinder power. contact: University of Applied Sciences Jena • Carl-Zeiss-Promenade 2 • 07745 Jena • Germany | Phone: 0049-(0)3641-205-415 | E-Mail: oliver.kolbe@fh-jena.de