Andrew Brandt, University of Texas at Arlington

Slides:



Advertisements
Similar presentations
T958! Fermilab Test beam experiment to study fast timing counters for FP420 MOU between UTA, Alberta, Louvain, Fermilab (Brandt spokesman) Data taking.
Advertisements

AFP QUARTIC Fast Timing System James L Pinfold University of Alberta.
Picosecond Timing Workshop 18 November Sales meeting 2005 Discovering the Future.
QUARTZTOFMike Albrow CMS-FP420 April 28 th 2008 QUARTZTOF An isochronous & achromatic Cerenkov Counter Making Cerenkov light parallel  point focusing.
Peter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute The HERA-B RICH counter.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
1 QUARTIC, A TOF for ATLAS/CMS Forward Protons You didn’t know that ATLAS+CMS had forward protons? FP420 = Forward Protons 420m downstream of CMS & ATLAS.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
1 QUARTIC: UTA Update Andrew Brandt, Chance Harenza, Joaquin Noyola, Pedro Duarte Preliminary UTA drawing of Mike Albrow’s concept for a fast time resolution.
Groups Involved University of Alberta, University of Texas at Arlington, University College London. Prague, Saclay, Stoneybrook, Giessen, Manchester,
LHC Fast Timing Detector R&D Use arrival time difference between protons to measure z- vertex compared with the central tracking primary vertex Purpose:
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
Fast Timing Workshop Krakow, Nov 29 - Dec 1 st 2010 Part 2b.
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
1 Fast Timing via Cerenkov Radiation‏ Earle Wilson, Advisor: Hans Wenzel Fermilab CMS/ATLAS Fast Timing Simulation Meeting July 17,
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
ATLAS Forward Proton Electronics Andrew Brandt, University of Texas at Arlington 1 AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream.
1 QUARTIC Update Andrew Brandt (UT-Arlington), Mike Albrow (FNAL), Jim Pinfold (Alberta) Preliminary UTA drawing of Mike Albrow’s concept for a fast time.
THE FORWARD PROTON DETECTOR AT DZERO Gilvan Alves Lafex/CBPF 1) MOTIVATION 2) DETECTOR OPTIONS 3) FPD R&D 4) OUTLOOK Lishep 98 Lafex/CBPF Feb 17, 1998.
1 ALICE T0 detector W.H.Trzaska (on behalf of T0 Group) LHCC Comprehensive Review, March 2003.
FP420/AFP Timing Two types of Cerenkov detector are employed: QUARTIC – two QUARTIC detectors each with 4 rows of 8 fused silica bar allowing up to a 4-fold.
The primary goal has been to have the AFP timing system fully defined for the AFP Technical Proposal by December The end result should be a system.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
TOP counter overview and issues K. Inami (Nagoya university) 2008/7/3-4 2 nd open meeting for proto-collaboration - Overview - Design - Performance - Prototype.
Development of TOP counter for Super B factory K. Inami (Nagoya university) 2007/10/ th International Workshop on Ring Imaging Cherenkov Counters.
Mike AlbrowSept 14 th 2006Time-of-Flight with GASTOFs im Test Beam 1 Fast Timing Counters for FP420/CMS and Test Beam Particle ID Mike Albrow, September.
Timing properties of MCP-PMT K.Inami (Nagoya university, Japan) - Time resolution - Lifetime - Rate dependence Photon Detector Workshop at Kobe,
July 4, 2008 SuperBelle Meeting, KEKPeter Križan, Ljubljana Peter Križan University of Ljubljana and J. Stefan Institute Burle MCP PMTs as photon detector.
Updates at Nagoya univ. K.Inami (Nagoya) - Photon detector R&D - Lifetime improvements - Simulation design study.
BURLE update Peter Križan Friday meeting, Mar 24, 2006.
17JUL13 1 ATLAS Forward Protons: Fast Time-of-Flight Detectors ATLAS Forward Protons: Fast Time-of-Flight Detectors Michael Rijssenbeek – Stony Brook University.
Barrel PID upgrade K. Inami (Nagoya) Ljubljana, Hawaii, Cincinnati and PID group - R&D status - Structure design - Prototype study - Beam test - Photon.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
1992PH.D. UCLA/CERN (UA8 Experiment discovered hard diffraction) Post-doc and Wilson Fellow at Fermilab -Discovered hard color singlet exchange.
Barrel PID summary K.Inami (Nagoya) Summary of R&D at Hawaii, Cincinnati, Ljubljana and Nagoya.
LHC-CC Validity Requirements & Tests LHC Crab Cavity Mini Workshop at CERN; 21. August Remarks on using the LHC as a test bed for R&D equipment.
FP420/AFP Fast Timing Stage I: LHC luminosity 2 x10 33  t < 20 ps (
Pileup Background Rejection Ex, Two protons from one interaction and two b-jets from another Fast Timing Detectors for FP420 z=c(TR-TL)/2  z (mm) =0.21.
Mike AlbrowFP420 – May Timing and Pile-up Considerations 1 Pile-up in trigger and pile-up off-line (HLT) very different issues. Here I consider.
AFP Fast Timing System Andrew Brandt, University of Texas at Arlington in collaboration with Alberta, Giessen, Stony Brook, and FNAL, Louvain, LLNL (CMS)
TORCH IOP meeting Manchester March 31, 2015 TORCH Maarten van Dijk On behalf of the TORCH collaboration (CERN, University of Oxford,
Fast Timing Detector R&D Use time difference between protons in pp->pXp events to measure z-vertex compared with primary tracking vertex Purpose: Pileup.
10 picoseconds original design goal (light travels 3mm in 10 psec!) gives large factor of background rejection; Phase I: lum up to several  t
Mike Albrow, FermilabHPS Comments, Manchester 20l0 Some random HPS comments Mike Albrow HPS is accepted in CMS as an R&D project : Physics case is accepted.
Reed Research Reactor reactor.reed.edu/pictures.html reactor.reed.edu/pictures.html 1 Moriah Tobin Modeling Quartz Cherenkov Detectors.
Time resolution for the full detector system: 1. Intrinsec detector time resolution 2. Jitter in PMT's 3. Electronics (AMP/CFD/TDC) 4. Reference Timing.
1 The Scintillation Tile Hodoscope (SciTil) ● Motivation ● Event timing/ event building/ software trigger ● Conversion detection ● Charged particle TOF.
ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely measure.
IFR Detector R&D status
Commissioning of the Crystal evaluation setup
HPS: R&D issues Krzysztof Piotrzkowski (UCLouvain/CERN)
Test Beam Studies for FP420 Fast Timing
Photon Detector for AFP
FP420 TOF- Past and Future TOF in ATLAS and CMS proposals The problem
NRC Kurchatov Institute, ITEP I. Korolko, M.Prokudin, Yu.Zaitsev
Update of time measurement results with the USB WaveCatcher board & Electronics for the DIRC-like TOF prototype at SLAC D.Breton , L.Burmistov,
Gamma-ray Large Area Space Telescope
Andrew Brandt (UT-Arlington), Mike Albrow (FNAL),
The Pixel Hybrid Photon Detectors of the LHCb RICH
Directional Optical Module Integration
Multianode Photo Multipliers for Ring Imaging Cherenkov Detectors
Tagger Microscope Detector & Electronics Status
Latest Results from T979: PSec Time-of-flight
Variable distance from beam.
Performance test of a RICH with time-of-flight information
Presentation transcript:

Andrew Brandt, University of Texas at Arlington Fast Timing R&D Andrew Brandt, University of Texas at Arlington Use arrival time difference between protons to measure z-vertex compared with the central tracking primary vertex Motivation: Pileup background rejection/signal confirmation for pppp ( =jets, Higgs, Etc.) Ex: Two protons from one interaction and two jets from another

Requirements for an LHC Proton Timing System 10 ps or better resolution at high luminosity High efficiency and full acceptance High rate capability (proton rates up to 5 MHz/pixel ) Segmentation for multi-proton timing Robust operation in high radiation environment 10 picosecond resolution is design goal (light travels 3mm in 10 psec!) gives ~x20 fake background rejection; originally considering 25 interactions per crossing, now designing for 50 interactions 2

QUARTID (QUARtz TIming Detector) QUARTIC concept: Mike Albrow for FP420 (R&D effort for diffractive Higgs at LHC) 2004 based on Nagoya Detector. proton photons Initial design: 4x8 array of 6x6 mm2 quartz bars , 8-12 cm long Isochronous—by mounting detector at Cherenkov angle, all light reaches tube at ~same time 1.4.1.1 1 2 3 4 MCP-PMT Proton is deflected into one of the rows and measured by eight different bars/detector with a micro-channel plate PMT. If t= 40 ps/bar need 16 measurements /row for 10 ps If t= 28 ps/bar need 8 measurements/row for 10 ps Increase #rows to minimize multi-proton and rate effects (pixelation)

Components of AFP Fast Timing Main components exist, and have been validated in pulser, laser, and beam tests

Lifetime Issues Historically MCP-PMT’s have not been extremely robust, and are typically capable of operating only for a few hundred mC/cm2 before their performance (QE) degrades, presumably due to positive ions damaging the photocathode. If operated at high gain without sensible pixelation, this amount of charge would be accumulated too quickly for the device to be useful For low gain (5E4) and modest pixelation (4 equal rate bins), the lifetime presents a challenge: =23 implies R=4 MHz/pixel and I=0.8 A/cm2 resulting in an annual charge of 8 C/cm2/yr (with LHC year =1x107s). This corresponds to Ldt=[23  (40 x 0.8) MHz]  t/100 mb=80 fb-1. In other words, for every 10 fb-1 or so 1 C/cm2 is accumulated. Formed a collaboration between UTA, Arradiance, and Photonis to address these issues, partially funded by NSF SBIR

Brandt’s Ideal MCP-PMT + Improved lifetime by x10-20 (3 main options) 1) Suppressed positive ion creation (Arradiance) 2) Ion Barrier keeps positive ions from reaching photocathode (Nagoya/Hamamatsu) 10 m pore EDR MCP for max rate ALD by Arradiance + + + 3) Use Solar Blind photocathode (UV response to more robust) photon Funding for Solution 1 Increase cathode voltage to improve collection efficiency (UTA) Photocathode Photoelectron DV ~ 400V Dual MCP DV <3000V Run at low gain to reduce integrated charge (UTA) Gain <105 MCP-PMT Increase anode voltage to reduce crosstalk (UTA) DV ~ 400V Anode Reduce anode gap to reduce cross talk

Laser Box Early setup LeCroy Wavemaster 6 GHz Oscilloscope Hamamatsu PLP-10 Laser Power Supply Established in 2009 at UTA with DOE Advanced Detector Research,+Texas ARP funds, primarily to evaluate MCP-PMT’s for use in fast timing. Relies heavily on the use of undergraduates The PTL serves as a permanent test bed to study a myriad of subtle effects associated with picosecond timing beam mode laser lenses filter MCP-PMT beam splitter mirror fiber mode 1)Evaluate MCP-PMT and electronics with laser tests 2) Evaluate detector/full chain with test beam Early setup

MCP-PMT Rate and Current Anode Current = proton Rate  Number of photo-electrons generated by each proton  Gain  charge 4 MHz proton rate with 10 pe’s at 106 gain gives 6.4 µA in a 0.4 cm2 pixel or about 16 µA/ cm2, several times what is possible! Conventional wisdom: need high gain for fast timing (but CW is based on single pe experience). From UTA laser tests timing is ~ independent of gain as long as Reduces current requirement by x10 to 20

MCP-PMT Cross Talk and TTS TTS=transit time spread Anode 2 Photons Anode 1 Electrical Crosstalk (charge sharing) Pe Rebound Optical Crosstalk t=38 ps Photoelectron Recoil Rebound Recoil Cross talk could correlate adjacent channels within a row and reduce expected N improvement Cross talk can give a false signal in channel in adjacent row which distorts/biases time measurement if there is a second proton in that row

Cross Talk and other MCP-Issues Pedro Duarte, Masters Thesis on early test beam studies 2007 Ryan Hall UTA, Honors Thesis on cross talk 2010 Paul Pryor UG Thesis on Lifetime 2011 James Bourbeau, Honors Thesis on test beam 2013 -Currently have team of 6 undergraduates (10-20/hr/week/person) Have studied and will continue to study many features of MCP’s @PTF Cross talk: Using a series of fibers with different path lengths to simulate proton arrival time, found that ~10% of pulse is collected in adjacent pixel due to charge sharing -improves resolution for pixels in same row and correlates pixels since light is in time -degrades resolution and biases time for pixels in adjacent row (on either side) for later arriving proton Two protons in same pixel mixes time in complicated manner After-pulsing and origins of lifetime issues Forming a data-based simulation of MCP response to augment GEANT capabilities Tuning cathode and anode voltage to maximize performance (increase collection efficiency and reduce cross talk for example)

Lifetime Issues Our first lifetime tests on ALD tube got out to 2 C/cm2 with no loss in QE but too resource intenstive, will start major new lifetime tests this summer Lehman et al As of today no loss in QE with Q>5 C/cm2!!! 10-20 improvement over typical tube 1C~10 fb-1; similar results reported bu Photek! Arradiance-Modified 10 m Planacon Hamamatsu ion barrier SL10

Wrap-up: Timing vs. Rate *Have demonstrated desired timing capability at 5 MHz (~largest desired rate) with a long life high rate 25 µm pore PMT! *a 10 µm pore version has about 3 times the current capability and should maintain timing well beyond 5 MHz *Development continues, Expect to be able to make a >10 C/cm2 tube, which would last 100 fb-1 or longer 5MHz (~2 µA/cm2) Concern: only small quantities of these special tubes have been produced, so yield is uncertain -> quote is 13 to 38 k$ 12

Designing a Baseline Detector Equal area detector bins are not in general a viable option due to rate and lifetime issues in the pixels closest the beam Equal rate pixels do not easily map to MCP-PMT pixels Smaller width pixels are better than larger ones, since if two protons are in the same pixel, neither one would be well-timed A full acceptance detector will suffer from cross talk, biasing neighboring rows To avoid this bias one needs to implement buffers between the rows Implies a two detector option with offset bins is a reasonable solution

A Potential Design: Two Offset QUARTIDS Increasing M beam Large x proton In 2013 will use simulation laser tests and (August FNAL test beam) to optimize layout, test beam in Jan 2014 to validate final design and electronics Increasing x Design considerations: 1) full acceptance, efficiency, excellent timing expected ~10 ps 8 to 10 rows with x =1.5 to 3 mm(x=distance of proton from beam) will avoid multi-proton effects (>90% efficient) and keep rate/pixel under 5 MHz to control current/lifetime issues (can also rotate tube 180 degrees x2 lifetime) 3) Buffers (space between rows) to avoid cross talk between rows Rows probably should have partial overlap for alignment

New Test Beam Setup Jan 2012 @FNAL FNAL SiPM used in trigger and as reference counter (15 ps resolution when used in beam with quartz bar) New Stony Brook amp cards plug directly onto PMT beam QUARTIC Prepared @UTA for easy alignment and versatility

T958 DAQ Time difference between SiPM and 6 –bar Quartic average gives FWHM=47 ps (=20 ps) better than design goal! 2 3 4 5 6 7 Avg Just your garden variety 20 channel, 20 GHz/ch, 40 Gs/s ch (point every 25ps) 500k$ LeCroy 9Zi scope! “Thanks for the loaner LeCroy!”

SiPM- Quartic 6-Bar Average CFD read out by SCOPE CFD read out by HPTDC t =19.5 ps t 26.2 ps 26.2 ps QUARTIC and SiPM signals amplified, sent to CFD, then to scope, calculate t(SiPM-Qi) and average over 6 bars. Repeat for HPTDC readout. Difference between the measurements is dominated by 16 to 18 ps resolution of SiPM HPTDC Extract QUARTIC resolution (6 bar) 14 to 15 ps including Q-HPTDC (Note: edge channels had different gain, not useful for this run)

Ultimate Timing System Resolution Component t(ps) Current Projected Action Radiator/MCP-PMT (~10 pe’s with 10 µ pores) 19 17 Optimize radiator CFD 5 - HPTDC 18 9? New HPTDC chip? Reference Clock 8 Total/bar 28 20 Total/ detector (6 ch) 12 Currently at 12 ps (Fall 2012 Test beam) with only 6 bars, and that ultimate performance of this system is probably about 8 ps

Highlights of R&D In umpteen test beams (7?) we have shown steady improvement, obtaining single quartz bar/PMT resolution of 20 ps in last one (for 2x6x140 mm and 5x6x140 mm) This corresponds to a 6 bar resolution including prototype readout electronics of 12 ps! We have developed with Arradiance+Photonis a phototube capable of >5 MHz proton rate/pixel that has been demonstrated to have lifetime > 5 C/cm2 expected to be good for >100 fb-1, including x2 from rotating tube, with further improvements likely Have successfully modified SLAC PLL Clock circuit that had sub-ps jitter for AFP’s circumstances