ENERGY METERS DME SERIES

Slides:



Advertisements
Similar presentations
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Advertisements

What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Efficient Management for Building Automation. Market Trend.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
© ABB ABB DELTAsingle Commercial and technical presentation.
© ABB ABB ODINsingle Commercial and technical presentation.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
GEN-SET CONTROLLERS RGK700 – RGK800.
Looking for a more powerful circuit monitor?
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Single Loop Analogue addressable fire control Panel
SFT 2841 IN CONNECTED MODE Prepare setting files.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
INDUSTRIAL DEFINED PROBLEM TEAM MEMBERS- A MAN M ITTAL MANASVI KUNDALIA SUNIDHI SINGH PRASTUTI.
The Quality Control Company Quanti TM product series “Simplicity is the ultimate sophistication” - Leonardo da Vinci.
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
ENERGY METER TO INDICATE BILLING IN RUPEES FOR LOAD WISE OR DAY WISE
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
AUTOMATIC POWER FACTOR CONTROLLERS
Voice Controlled Robot by Cell Phone with Android App
Multiway Noticeboard with User Configure Features Using IOT & PC
SGC-250 Synchronous Generator Controller
C1300 advanced circular chart recorder
IP-based 8-port Switched Power Manager
Training on Power Monitoring and Management Solution
What is ASEMR /ASKUE/ and the Need for Its Implementation
System Network Structure
New EM210_AV.
PRE-PROGRAMMED DIGITAL SCROLLING MESSAGE
SCADA for Remote Industrial Plant
Haiwell PLC Modules Introduce
TPS - Thyristor Power Supply for Resistive/Inductive Loads
How SCADA Systems Work?.
DIGITAL CALCULATOR USING 8051
The FG series of explosive and toxic gas detectors and panels
GEN-SET CONTROLLERS GEN-SET CONTROLLERS
PowerValue 11 RT Sales Presentation
Flow-X/C Flow Computer
The Trend BMS An Introduction to BMS
Maximize your availability
NT24k® & 1000 PoE+ Offerings October 2016.
ICP DAS Power Monitor and Management Solution 2016,03,28
PowerValue 11/31 T Sales Presentation
AI1 input2 AI0 input1 DI1 DI2 DI2 DI1.
METER SPECIFICATIONS.
Introduction: New Compact Display Panel SimpleTouch
Distributed Energy Engineering
Reliable Fixed-Zone Systems
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
PowerLogic™ offer for the basic metering market
Energy Meters ME.
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Digital Computer & Digital Systems
Power monitoring software
Presentation transcript:

ENERGY METERS DME SERIES

ENERGY METERS DME SERIES THE LOVATO ELECTRIC SOLUTION In a market scenario where the energy consumption must be controlled and managed in an efficient way, Lovato Electric has a new energy meters series. Expandability with EXM modules High measurement currents in small housing Multi-measurement Built-in RS485 version Digital display with white backlight MID approved version M40 GB 05 02 14

ENERGY METERS DME SERIES SINGLE PHASE Mechanical Digital RANGE DME M100 DME M100 T1 DME D100 T1 DME D110 T1 DME D115 T1 DME D120 T1 DME D121 DME D130 N° of modules 1 2 Current 32A 40A 63A Multimeasurement - ● Outputs 1 (progr.) 1 (pulses) Inputs Display LCD LCD with backlight Expandability EXM… Built-in comm. RS485 M40 GB 05 02 14

ENERGY METERS DME SERIES SINGLE PHASE Mechanical Digital RANGE DME M100 DME M100 T1 DME D100 T1 DME D110 T1 DME D115 T1 DME D120 T1 DME D121 DME D130 kWh ● Total and partial kvarh - V, A, Hz, PF kW, kvar, kVA kW EXM for DME D130: EXM1000, EXM1001, EXM1002 (digital I/O) with 2 limit thresholds on kW by default Compatibility with EXM1010 (USB), EXM1011 (RS232), EXM1012 (RS485), EXM1013 (ethernet) under technical investigation M40 GB 05 02 14

ENERGY METERS DME SERIES THREE PHASE RANGE DME D300 T2 DME D310 T2 DME D320 N° of modules 4 Current 63A CT /5A Multimeasurement ● Outputs 2 (progr.) - Inputs 1 Display LCD with backlight Graphic LCD with backlight Expandability Built-in comm. M40 GB 05 02 14

ENERGY METERS DME SERIES THREE PHASE RANGE DME D300 T2 DME D310 T2 DME D320 kWh Total and partial Imp/Exp Tot/Par Each single phase kvarh V, A, Hz, PF ● kW, kvar, kVA Total and per phase M40 GB 05 02 14

ENERGY METERS DME SERIES ACTIVE ENERGY MEASUREMENT – DIRECTIVE 2004/22/EC (MID) Energy meters are mainly intended to measure energy for billing purposes In European Union, every measuring instrument for billing must comply with and be certified according to MID (Measuring Instruments Directive) The energy meter is designed to be safe and accurate (Type tests). MID warrants The energy meter is produced to be safe and accurate (Production conformity ). All DMED energy meters are available in a version with MID approval. “MID” suffix at the end of order codes. M40 GB 05 02 14

ENERGY METERS DME SERIES ACTIVE ENERGY MEASUREMENT – ACCURACY MID and non-MID active energy meters comply with different standards: Non-MID: IEC/EN 62053-21 MID: EN 50470-3. A complete correspondence between the two standards does not exist. MID meters EN 50470-3 Non-MID meters IEC/EN 62053-21 Accuracy Class A Class 2 ±2% Class B Class 1 ±1% Class C - ±0.5% M40 GB 05 02 14

ENERGY METERS DME SERIES GENERAL FEATURES Metrological LED DMED series is equipped with a metrological LED to indicate the energy consumption Multifunction key Partial counters cleraing Measurement browsing Programming. Sealable terminal covers are standard-supplied. DME M100 DME M100 T1 DME D100 T1 DME D110 T1 DMED 115 T1 DME D120 T1 DME D121 DMED130 DME D300 T2 DME D310 T2 DME D320 640 Imp/kWh 1000 Imp/kWh 10000 Imp/kWh - ● M40 GB 05 02 14

ENERGY METERS DME SERIES Fixed pulses Progr. DME M100 - DME M100 T1 1 DME D100 T1 DME D110 T1 DMED 115 T1 DME D120 T1 DME D121 DME D130 DME D300 T2 2 DME D310 T2 DME D320 STATIC OUTPUT The static outputs can be: Pulses for active energy counting (kWh) User programmable in order to get: Automatic reset. Overtaking of a limit threshold on a controlled measurement Pulses for active energy (kWh) or reactive energy (kvarh) counting. After K pulses, 1 kWh is counted (accumulated). M40 GB 05 02 14

ENERGY METERS DME SERIES STATIC OUTPUT PROGRAMMED AS LIMIT THRESHOLD 50mA at 24VDC The overtaking of the limit threshold enables a buzzer to advise the user about a power shutdown. 8LP 2T ZGB Adding a timer, the static output can enable the buzzer and a timer that, after the programmed delay, opens a non-priority load. TM M2 The information is transmitted to a programmable relay to: Display a message. Enable a buzzer. Enable timers to open non-priority loads. Let the user choose which load should be disconnected using the front panel keys. KINCO M40 GB 05 02 14

ENERGY METERS DME SERIES DME D130 - DME D310 T2 EXPANDABILITY DME D310 T2 includes more functions when the expansion EXM… modules are installed: EXM1000/EXM1001 (Inputs/Outputs) EXM1010 (USB) EXM1011 (RS232) EXM1012 (RS485) EXM1013 (Ethernet) EXM1020 (RS485 + 2 relay outputs) EXM1030 (Memory). 3 x EXM… DME D310 T2 M40 GB 05 02 14

ENERGY METERS DME SERIES BUILT-IN COMMUNICATION PORT DME D121 and DME D320 are equipped with built-in RS485 port, compatible with Synergy RS 485 M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD – DATA CONCENTRATOR The data concentrator DME CD connects devices with no communication port but with at least one pulse output (i.e. DME energy meters) to a network. 3 x EXM1000/EXM1001 to get up to 14 pulse inputs Built-in RS485 DME CD has: RS485 port 8 inputs available Expandability with EXM… modules. 2 x EXM1000/EXM1001 to get up to 12 pulse inputs + 1 x EXM1013 for Ethernet communication Built-in RS485 M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR General counters (16) Settings: Enabling page description (16 character free text) Units description (6 character free text) Count UP source Count DOWN source Reset source (total and partial) Count up source weight (multiplier/divider) Count up source weight (multiplier/divider). Switch on Inputs Limit thresholds Boolean variables Remote variables M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR 16 general counters 16 derivative variables (average) 16 trend graphs Settings: Enabling Derivative calculation time Units description (6 characters) Derivative coefficient (multiplier/divider). 16 mathematical variables Available operations with counters: Sum, subtraction, multiplication, division Arithmetics with a constant value Mathematics can be operands as well page description (16 character free text), units description (6 character free text). M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR 16 4-tariff pages 16 general counters 16 derivative variables (average) Limit thresholds 16 mathematical variables Pulses M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Some advanced functions come from DMGs: Hour counter (with limit thresholds) Boolean logic operations Remote variables Alarms Programmable inputs and outputs. M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 1: Collecting data and alarms in a marina DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN DMECD RS485 IN1…8 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 Each station has: - DMED (1 or 3 ph) with pulse output - Low power alarm - Power supply enabling. DMECD RS485 IN1…8 EXM1001 IN1…2 OUT1…2 EXM1001 IN1…2 OUT1…2 EXM1013 Ethernet PC, internet, VPN, … DMED ALA EN DMED ALA EN DMED ALA EN DMED ALA EN M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 1: Collecting data and alarms in a marina DMKSW software can read: Energy meters Average power values (derivative) Energy cost (mathematics) Alarms Enabling commands. M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD - DATA CONCENTRATOR Example 2: Collecting data and alarms in a bottle filling machine DMECD Energy pulses DMED300T2 : 1 counter to store the energy consumption 1 mathematics to calculate the energy consumption every 100 bottles (kWh/100 bottles) Count-up source 1 counter to count up and down the bottles 1 derivative variable to calculate the production rate (bottles/minute) Bottles passage photocell Quality control Count-down source Rejected M40 GB 05 02 14

ENERGY METERS DME SERIES SWITCH Ethernet Wi-Fi INTERNET VPN EXP1013 EXP 1012 8 + 4 max with EXM10... Ethernet DMG 800-900 DMG 300 + EXM1013 DMG 800-900 + EXP1013 DME CD data concentrator + EXM1013 Energy meters with pulse output DME .. T1 Ethernet 8 + 6 max with EXM10… RS485 ETH-RS485 RS485 RS485 DMG 210 DMG 300 + EXM1012 DMG 700-800-900 + EXP1012 DMK … DME CD (Data concentrator) M40 GB 05 02 14

ENERGY METERS DME SERIES SHOPPING CENTRE APPLICATION Ethernet Energy cost monitoring and allocation Power factor monitoring M40 GB 05 02 14

ENERGY METERS DME SERIES DME CD PV1 DME CD expecially programmed for photovoltaic application: Absorbed energy counter input (1000 p/kWh) Generated energy counter input (1000 p/kWh) Mathematical exchanged energy counter Self-consuming estimator (power and energy) Autonomy from Utility estimator 2 outputs to disconnect non priority loads 1 input for alarms from inverters DME CD KIT PV1 100 = DME CD PV1 + 2 x DME D110T1 Built-in RS485 M40 GB 05 02 14

ENERGY METERS DME SERIES Thanks for your attention! www.LovatoElectric.com