Sinsuoidal steady state power

Slides:



Advertisements
Similar presentations
Since Therefore Since.
Advertisements

Each of the circuit elements will have a different ac current response to an applied ac voltage. We need to look at each of these elements. Resistor:
Complex Power – Background Concepts
Sinusoidal Steady-State Power Calculations
CH5 AC circuit power analysis 5.1 Instantaneous Power 5.2 Average Power 5.3 Effectives values of Current & Voltage 5.4 Apparent Power and Power Factor.
ECE 201 Circuit Theory I1 Complex Power Designate as S Magnitude of S = Apparent Power Units are Volt-Amperes The complex sum of Real Power (P) and Reactive.
STEADY STATE AC CIRCUIT ANALYSIS
Lect19EEE 2021 AC Power Dr. Holbert April 9, 2008.
AC Power Discussion D9.3 Chapter 5. Steady-State Power Instantaneous Power Average Power Effective or RMS Values Power Factor Complex Power Residential.
Announcements Be reading Chapters 1 and 2 from the book
Lesson 24 AC Power and Power Triangle
Lecture 26 Review Steady state sinusoidal response Phasor representation of sinusoids Phasor diagrams Phasor representation of circuit elements Related.
Lecture 31 Sinsuoidal steady state power Instantaneous and average (real) power Reactive power Complex power Power factor Related educational modules:
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Circuits II EE221 Unit 4 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Alexander-Sadiku Fundamentals of Electric Circuits
Fundamentals of Electric Circuits Chapter 11
ECE 2300 Circuit Analysis Dr. Dave Shattuck Associate Professor, ECE Dept. Lecture Set #25 Complex Power W326-D3.
INC 112 Basic Circuit Analysis Week 12 Complex Power Complex Frequency.
Fundamentals of Electric Circuits Chapter 11
Solid State Electricity Metrology
EGN 3373 Introduction to Electrical Systems I A Systems Approach to Electrical Engineering Graphics Adapted from “Physical, Earth, and Space Science”,
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
AC POWER ANALYSIS Instantaneous & Average Power
Chapter 7 AC Power Analysis
Circuits II EE221 Unit 11 Instructor: Kevin D. Donohue Complex Power, Power Conservation, Power Factor Correction, and Applications.
Chapter 11 AC Power Analysis
Lab 13 – Complex Power EE 188L. Instantaneous Power Time domain.
1 Lecture #9 EGR 272 – Circuit Theory II Read: Chapter 10 in Electric Circuits, 6 th Edition by Nilsson Chapter 10 - Power Calculations in AC Circuits.
Chapter 10 Sinusoidal Steady- State Power Calculations
1  Explain and calculate average power, apparent power, reactive power  Calculate the total P, Q and S and sketch the power triangle. ELECTRICAL TECHNOLOGY.
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
AC POWER & POWER FACTOR. Lesson Objectives  Compute and define apparent, reactive, and average power for capacitors, inductors, and resistors.  Compute.
CHAPTER 2: DC Circuit Analysis and AC Circuit Analysis Motivation Sinusoids’ features Phasors Phasor relationships for circuit elements Impedance and admittance.
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
1 Chapter 3 AC Power Analysis. 2 AC Power Analysis Chapter 3 3.1Instantaneous and Average Power 3.2Maximum Average Power Transfer 3.3Effective or RMS.
EGR 2201 Unit 13 AC Power Analysis  Read Alexander & Sadiku, Chapter 11.  Homework #13 and Lab #13 due next week.  Final Exam and Lab Exam next week.
Lesson 3: Ac Power in Single Phase Circuits
Power in AC Circuits Introduction Power in Resistive Components
Module B3 3.1 Sinusoidal steady-state analysis (single-phase), a review 3.2 Three-phase analysis Kirtley Chapter 2: AC Voltage, Current and Power 2.1 Sources.
Chapter 11 AC Power Analysis
Electric Circuits (EELE 2312)
SYLLABUS AC Fundamentals AC Analysis AC power Three phase circuit
Lesson 21: AC Power and Power Triangle
Chapter 11 AC Power Analysis
Lecture 07 AC POWER & POWER FACTOR.
AC POWER & POWER FACTOR.
Sinusoidal Excitation of Circuits
EFFECTIVE OR RMS VALUES
Network Circuit Analysis
Islamic University of Gaza
Lecture 31 Sinsuoidal steady state power Related educational modules:
ECE 2202 Circuit Analysis II
ELECTRIC CIRCUITS EIGHTH EDITION
Sinusoidal Waveform Phasor Method.
Power in AC Circuits Introduction Power in Resistive Components
POLYPHASE CIRCUITS LEARNING GOALS Three Phase Circuits
Chapter 11 AC Power Analysis
Electric Circuits Fundamentals
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
Islamic University of Gaza
Chapter 11 – Power AC Circuits
The instantaneous power
EEE 3230 POWER SYSTEM ANALYSIS
E E 2415 Lecture 9 Phasor Circuit Analysis, Effective Value and Complex Power: Watts, VAR’s and Volt-Amperes.
Chapter 11 – Power AC Circuits
Engineering Circuit Analysis
Presentation transcript:

Sinsuoidal steady state power Instantaneous and average (real) power Reactive power Complex power Power factor Related educational modules: Section 2.9.0, 2.9.1 1

AC power Power is still the product of voltage and current: We are now interested in the case in which the voltage and current are sinusoids: 2

v(t) and i(t) are related 3

Instantaneous AC power Our previous (time domain) definition of power is called the instantaneous power In terms of our sinusoidal voltage & current: After some trigonometry and algebra: The power consists of a DC (constant) part and an AC (sinusoidal part) 4

Graphical representation of p(t) 5

Alternate representation for p(t) Which can be decomposed into two plots: Average (real) power and reactive power 6

Average Power We are generally more interested in the average power delivered to a load: Average power is: This is also called the real power (it’s the power that’s provided to the resistive part of the load over time) Units are watts 7

RMS values We want to assess the power delivered by different types of time-varying signals The power delivered to a resistive load: Find a DC (constant) value which delivers the same average power as the time-varying signal Called the effective or RMS value of the signal Used to “compare” different time-varying signals 8

Note why it’s called “RMS” Note: we want our average power to look like an “average” current squared times resistance or an “average” voltage squared divided by resistance We want to define these “effective” values Note why it’s called “RMS” 9

RMS values – continued Average power: Effective DC value: Equating to time-average value: , 10

Annotate previous slide to show VRMS, IRMS notation (RMS = “effective”) 11

Definition of RMS values The effective (or RMS) value of a signal is equal to the DC value which provides the same average power to a resistor For sinusoidal signal with no DC offset: , Average power in terms of RMS values: 12

Apparent power and power factor Power in terms of RMS values: The average (real) power is the product of apparent power and the power factor Apparent power: (units = volt-amps = VA) Power factor (pf): (unitless) Power factor is leading or lagging, to denote whether current leads or lags voltage 13

Interpretation of apparent power and pf Power factor is a property of the load For a complex load, the power delivered to the load is not exactly the power supplied by the generator If ZL is real  pf = 1 If ZL is imaginary  pf = 0, and no average power is delivered to the load 14

On previous slide, mention reactive power again. 15

Complex Power Complex power is a way to conveniently expressing the various power parameters and their relationships  or: 16

Annotate previous slide to show real (average) power and reactive power 17

Power relationships Complex power: Magnitude of S is the apparent power (units = VA) The real part of S is the average power (units = watts) The imaginary part of S is the reactive power (units = VAR) 18

Power Triangle 19

Example For the circuit below, (a) find the average power delivered by the source (b) find the powers absorbed by the resistor and capacitor (c) find the apparent and reactive powers delivered by the source (d) sketch a power triangle for the source 20

(a) find the average power delivered by the source 21

(b) find the powers absorbed by the resistor and capacitor 22

(c) find the apparent and reactive powers delivered by the source 23

(d) sketch a power triangle for the source Apparent power: 391VA Average power: 305W Reactive power: -244VAR 24

25