LIQUID CHROMATOGRAPHY

Slides:



Advertisements
Similar presentations
PRINCIPLES OF A CALIBRATION MANAGEMENT SYSTEM
Advertisements

1 The YL9100S HPLC All your needs for semi-preparative applications.
D e t e c t o r s f o r H P L C.
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
Mobile phase is a gas! Stationary phase could be anything but a gas
Nanodrop 2000c. Who is NanoDrop? Manufacture and Cell analytical laboratory equipment worldwide Used in biotechnology, pharmaceutical, and life science.
Compact & Perfect for Your Satisfaction
Caffeine as a Surrogate for Cocaine in an HPLC Forensic Experiment Ray A. Gross Jr, Indravadan Shah and Muhamed Jasarevic Department of Physical Sciences.
HPLC 1. Introduction 1.Introduction CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution.
1 1. Introduction H: High P : Performance (Pressure) L : Liquid C : Chromatography GC : Gas chromatography TLC: Thin layer chromatography IC : Ion chromatography.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Institute of Chemical Sciences
Introduction to the HPLC ChemStation and Acquisition.
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
High Performance Liquid Chromatography
Organic Chemistry I - Lab
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
Varian 920-LC Integrated Analytical HPLC
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
History of Chromatography n Early LC carried out in glass columns n diameters: 1-5 cm n lengths: cm n Size of solid stationary phase n diameters:
900-LC P. van Poppel – Field Support Specialist October 2009.
VARIAN, INC. HPLC Products
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Analysis of Ibuprofen in Tablets According to the US Pharmacopoiea using a Varian 920-LC Analytical HPLC and Pursuit ® XRs column By Phuong Truong Varian.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Extraction and HPLC of Hypericin Courtney Arnott Intermediate Lab Fall 2001.
HPLC – High Performance Liquid Chromatography
Introduction  High-performance liquid chromatography (HPLC) is a form of liquid chromatography.liquid chromatography  The main purpose is to separate.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
Stability Indicating Assays for Dose Formulation Stability Testing Teresa Fuller GSK.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chapter 28 High Performance Liquid Chromatography.
Varian 920-LC Competitors. 2 Varian 920-LC Market Competitors Competitors Shimadzu Waters Agilent Dionex The 920-LC presents a significant step forward.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
HPLC 1. Introduction 1.Introduction  INSTUMENTAL ANALYSIS  PRACTICAL 213 PHC  HPLC.
Comparison of the Varian 920-LC with Agilent 1200 Series HPLC.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
INTRODUCTION ON HPTLC PRINCIPLE
DETERMINATION OF  9 -TETRAHYDROCANNABINOL BY HPLC/DAD IN FOOD SUPPLEMENT SAMPLES OF HEMP SEED OIL Maja Shishovska 1, Dragica Doneva 1, Katerina Starkovska.
GAS CHROMATOGRAPHY Mr. Maywan Hariono.  One of chromatography technique that use a gas as a carrier (mobile phase)  The separation is based on the volatility.
High Performance Liquid Chromatography. What is HPLC ? It is a separation technique that involves: Injection of small volume of liquid sample Into a tube.
High Performance Liquid Chromatography Presented by Dr. Kamal Modi 2 nd Year Resident.
Gel Permeation Chromatography Size Exclusion Chromatography
UV/VIS SPECTROSCOPY.
LIQUID CHROMATOGRAPHY
Chem. 133 – 5/11 Lecture.
High Performance Liquid Chromatography HPLC
PORTABLE HIGH-SPEED GAS CHROMATOGRAPH
Size Exclusion Chromatography (SEC)
FlexarTM: Advances in HPLC Sample Throughput
SPECTROPHOTOMETER UV 2080 PLUS DOUBLE BEAM
Best Broken into four categories
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Diagnostics Analytical 920 LC Semi-Prep 940 LC
High Accuracy UV-VIS Spectroradiometer ( nm)
Chromatography Daheeya Alenazi.
Liquid Chromatography - Method Development and Validation
Introduction to the NGC Chromatographic System
Gas chromatography Software
High-Performance Liquid Chromatography
Levofloxacin structural formula
GAS CHROMATOGRAPHY.
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
Fig. 6. HPLC analysis of RP key components
Damiana Gentili Qualified Person/QU Director 09/05/2019
32A-2 Sample Injection system
High-Performance Liquid Chromatography
Presentation transcript:

LIQUID CHROMATOGRAPHY High PERFORMANCE LIQUID CHROMATOGRAPHY 3000 PLUS

Analytical Technologies is synonymous for offering technologies for doing analysis and is the fastest growing global brand having presence in at least 96 countries across the globe. Analytical Technologies Limited is an ISO:9001 Certified Company engaged in Designing, Manufacturing, Sales, Marketing, Distribution & Providing Services for the Analytical, Chromatography, Spectroscopy, Biotechnology, Biomedical, Clinical Diagnostics, Material Science & General Laboratory Equipment. Analytical Technologies, India has across the Country operations with at least 4 Regional Offices, 6 Branch Offices & Service Center. Analytical Technologies also provides Accessories, Consumables, Services and trainings.

Our Products & Technologies Chromatography Spectroscopy Bio medical Bio-Technology Material science General lab instruments

INTRODUCTION High performance liquid chromatography (HPLC) is a form of High-pressure chromatography that uses a pump to control the speed at which the mobile phase passes through the stationary phase. High performance liquid chromatography systems generally consist of a  Quaternary pump, Auto sampler, Column oven, UV-Visible detector, Refractive index detector, Diode array detector and operate at pressures of ~9,000 psi.

PUMP - 3000 PLUS Analytical Technologies 3000 Plus HPLC with quaternary pump. Max. Pressure: 9000 psi Flow Rate: 0.0001 - 10.000 ml/min (increment 0.001 ml/min.) Flow Accuracy:± 0.01% (1.000 ml / min) Flow Precision:± 0.1 % RSD Composition Precision - ≤ 0.1% RSD Concentration accuracy - ± 0.5% or better Gradient reproducibility - ≤ 0.2% SD

Quaternary System with Auto sampler- 3000 Plus Quaternary system possesses the advantage of great flexibility, and it can further be automatized by combing our auto sampler. This combination could fulfill the complex requirements from pharmacy, agricultural & farming fields. With the control from Chromatography workstation, it realized full automatic analysis, report, system flush, shut down and then raised up the efficiency. environmental, food safety, petrochemical engineering.

Auto sampler- 3000 Plus Autosampler delivers high injection accuracy of 0.3% RSD with advanced control algorithm. Multi injection mode have three sampling mode including full loop, partial loop and micro pick up injection. For low cross contamination, special design of needle washing assembly could clean interior and outside of the sampling needle separately. Cross contamination - <0.1% Injection Volume – Programmable from 0µl – 99.99 µl Injection precision : Full loop injection <0.2% RSD Partial loop-fill <0.5% RSD µl-pick-up <1.0% RSD Carry Over <0.003% RSD with standard wash Typical <0.001% RSD with extra wash Vials : 2x 48 (1.5ml) Sample capacity – Micro Plates : 192 Vials : 120 (2ml)

Working principle of Autosampler

Column Oven – 3000 plus Temperature range - 10ºC to 100ºC Temperature accuracy - ± 1.0ºC Temperature stability - ± 1.0ºC Temperature precision - ± 1.0ºC Column Length – 300mm, up to two columns Option – Peltier Power Consumption – 145W

UV- Vis Detector-3000 Plus As support by unique high speed signal processing technology, UV-VIS detector realized 100 Hz sampling rate, which make the detection of narrow peak with width lower than 5s possible. Its wavelength range : 190-800 nm with accuracy of +1 nm This high sampling rate also helps to record the chromatography peak accurately and get the best resolution.

Diode Array Detector-3000 Plus 3000plus has a 1024 diode array sensor with pixel resolution of 0.6nm. Combine with high quality optical grating, Record full high resolution spectrum while chromatograph recording. Its wavelength range : 190-800 nm with accuracy of +1 nm This high sampling rate also helps to record the chromatography peak accurately and get the best resolution.

Refractive Index Detector- 3000 Plus Refractive Index Detector with Deflection type measuring method. Refractive index range – 1.00 to 1.75 Measuring range – 0.125 to 256 µRIU Temperature range – 0-50ºC Flow rate – 0.2-3.0 ml/min Auto zero – Full auto zero Auto zero range – All range

Chromatography WorkStation Analchrome® workstation furthers the capability of Analytical Technologies High Performance Liquid Chromatography- 3000 PLUS system with Analysis solution research and development, instrument control, data acquisition and processing, report generation, and traceable record management with versatile extensibilities.

Analchrom chromatography workstation in a way to comply with the requirements of the 21 CFR Part 11 directive of the FDA. This ensures its suitability for use in regulated environments. Audit Trail of whole system, chromatograms, calibrations and sequence. Audit Trails are part of corresponding files. Detailed logs and histories of modifications enable users to maintain an audit trail. The station documents all parameters describing the conditions and methods of data processing for the user. This allows for easy access to a complete profile of information regarding any prior modification's performance.

Direct instrument control plus intuitive user interface give user the simplicity of operating the instrument from software. Simple method editing interface and powerful data processing with more than twenty integral functions.

Various calibration procedures and customizable report editor.

Application and solutions

Registered Office :   ANALYTICAL TECHNOLOGIES LIMITED Analytical House E67 and E68 RAVI PARK  VASNA ROAD VADODARA GUJARAT INDIA- 390015 Tel :91-265-2253620  TEL /FAX : 91-265-2254395 Emails: info@hplctechnologies.com, info@analyticalgroup.net info@multiplelabs.com info@analyticalfoundation.org. Skype: analyticaltechnologiesltd www.analyticalgroup.net www.hplctechnologies.com www.multiplelabs.com www.ais-india.com www.analyticalbiomed.com www.analyticalfoundation.org BROWSE OUR WEB SITES, SOCIAL MEDIA FOR TIME TO TIME UPDATES