ABX Pentra DF 120 Flexible hematology platform For internal use only

Slides:



Advertisements
Similar presentations
WBC Morphology and Cases
Advertisements

What happens in the aperture?
Unicel DxH 800 Flags, Codes, & Messages
DxH 600 Flags, Codes, MessagesDxH 800 Flags, Codes, & Messages
HEMATOLOGY WHAT IT IS : Study & measurement of individual elements of Blood. WHAT IT’S COMPOSED OF. SHOW SLIDES FROM PERIPHERAL BLOOD TUTOR CD OR USE PLATE.
Analytic Phase of Laboratory Testing
Hematology RBC/WBC Case Studies
MLAB 1415: Hematology Micros 60.
Introduction to Instruments
Automated CBC Parameters Quality Control
Automated Hematology Cell Counters
Examination of bone marrow aspirates
Hematology Laboratory 1 2/4/14
ADVIA 120 TECHNOLOGY. ADVIA 120 TECHNOLOGY.
Buffy coat (leukocytes and platelets) - <1%
DxH 800 Flags, Codes, Messages
Automated Hematology Cell Counters
Univ of Minn, Hematography Plus. umn
Automation in hematology Until Slide 23
-Automation blood count -Red and White blood count and differential count (Manual blood count) Prepared by: Mona alharbi Experiment:
The Complete Blood Count
Agile - affordable - accurate Optical System and Measurement Technology Presentation.
-Automation blood count -Red and White blood count and differential count (Manual blood count) Experiment:
Objectives 1. Methods used to measure the different hematological values, and compare it with the normal values. 2. The calculation of RBC indices, their.
Tabuk University Hematology – 2, MLT 307
A compact 5-diff solution
Agile - affordable - accurate. Hematology, is the part of internal medicine, that is concerned with the study of blood, the blood-forming organs, and.
Analyticon Biotechnologies AG
HEMATOLOGY the branch of medicine devoted to the study of blood, blood-producing tissues, and diseases of the blood.
Clinical Haematology & Cell Counting
CLS 541-Advanced Medical Haematology M. sc. Program Lab-2-
Automation in haematology
Pictures/Diagrams Copyright © University of Nebraska
Complete Blood Count.
Chapter 5 Hematology. Figure 5.1 (a) A double ended needle partially pierces the rubber stopper in an evacuated tube. (b) After the left needle pierces.
 IVF: D5 IMB 500mL to run at gtts/min  Request for: ◦ CBC with platelet ◦ Gram stain of wound discharge ◦ Culture and sensitivity of wound discharge.
Blood Smear.
George 17.5 yr NM DSH Presented to local clinic for severe lethargy Treated 5 months prior for severe anemia. Mycoplasma had been the differential and.
Clinical pathology: Complete Blood count
Correct interpretation of prepheral blood smear
Course title: Hematology (1) Course code : MLHE-201 Supervisor :Prof.Dr Magda Sultan Date : Outcome : The student will be able to use the automated.
Preparing a Blood Smear. Samples for Hematology Capillary blood and venous blood can be used for hematology tests. Capillary blood is beneficial if a.
Part III Automation in Hematology and Hemostasis
HAEMATOLOGY LINE A.C.KAROBIA
Flags, Codes and Messages on the COULTER® LH 750/755
REVISION.
Heamatology The diagnosis, treatment, and prevention of diseases of the blood and bone marrow as well as of the (blood clotting) and vascular systems.
Case 316 Ryan Johnson, MD; Athena Cherry, PhD; Dita Gratzinger, MD, PhD Stanford University Medical Center SH-EAHP October 24, 2013.
Automatic Electronic Blood Cell Counting
Medical Laboratory Instrumentation
Automated Hematology Cell Counters
White Blood Cell Differential Count
In the heart of hematopoïesis
International Operations
(待機画面) © 2007 HORIBA, Ltd. All rights reserved..
اساس اندازه گیری در سل کانتر
Micros 60 & Quality Control
Department of Pathology
PENTRA 60 C +.
ABX welcomes the SIMeL April 29th, 2004 ABX Pentra DX 120 Conclusion
Product specification
JCM OSCE YCH 3/7/2013.
Supplementary Figure S7
Special Stain.
MEK-6400 series Technical seminar
Special Stain.
Complete Blood Count (CBC)
Cat with Fever and Depression
Checkpoint kinase 1 is essential for fetal and adult hematopoiesis
“Algorithm Issues” in a Canine Hemogram
Presentation transcript:

ABX Pentra DF 120 Flexible hematology platform For internal use only Prepared by L.Castellane

Main features analysis Methods and technologies Pentra ML ABX Pentra DF 120 Main features analysis Methods and technologies Pentra ML Prepared by L.Castellane

Optional slide maker and stainer Main features Rack loader Reagent compartment Technical software Processed tubes Stat Sample Bay ABX Pentra ML Optional slide maker and stainer Prepared by L.Castellane

IMmature Lymphocyte, Monocyte and Granulocyte Main features CBC, DIFF IMmature Lymphocyte, Monocyte and Granulocyte Optional and integrated slide maker and stainer Expert Validation Station Prepared by L.Castellane

Wbc, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw, Plt, Mpv, Pct, Pdw Main features 32 Parameters CBC (12 parameters) Wbc, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw, Plt, Mpv, Pct, Pdw Differential count (12+20 parameters) Lym, Mon, Neu, Eos, Baso, Aly, Lic (% and #) IML, IMM, IMG (% and #) Throughput (12O samples per hour) Prepared by L.Castellane

5 reagents Unique blood control ABX Difftrol - 3 levels ABX Diluent Main features 5 reagents ABX Diluent ABX Basolyse ABX Leucodiff ABX Alphalyse or ABX Lysebio (Cyanide free) ABX Cleaner Unique blood control ABX Difftrol - 3 levels Target values on disk, multi-language package insert ABX reagents and controls are bar-coded and CE marked Batch number, level detection, small reagent volumes, waste level sensor Prepared by L.Castellane

External and internal bar-code reader Main features 3 types of analyses (with random access) CBC DIFF SPS External and internal bar-code reader Prepared by L.Castellane

Main features analysis Methods and technologies Pentra ML ABX Pentra DF 120 Main features analysis Methods and technologies Pentra ML CBC principles 5 Diff – Double matrix Prepared by L.Castellane

Methods & technologies RBC/PLT - Impedance method HGB - Cyanmethemoglobin or cyanide free WBC - (Triangulation) -> WBC channel (impedance) -> BASO channel (Specific lyse + impedance) -> 5Diff channel (optical) Prepared by L.Castellane

Methods & technologies 5Diff Principles  1. Cytochemistry Lysing of red blood cells Staining of nuclei and cytoplasmic granules of leukocytes Fixing the leukocytes in their original state (48 hours post-draw stability) 2. Double Hydrodynamic Sequential System (DHSS) Flow cytometer with hydrodynamic focusing before and after the micro-aperture 3. Impedance method Measurement of the cell volume (“X” axis)    4. Light absorbance Internal structure (“Y” axis) Prepared by L.Castellane

Methods & technologies Double Diff Matrix Eosinophils Large Immature Cells Neutrophils IMmature Granulocytic line Lymphocytes IMmature Monocytic line Monocytes IMmature Lymphocytic line Atypical LYmphocytes Prepared by L.Castellane

Methods & technologies IMmature Granulocytes Myeloblast IMG Promyelocyte Myelocyte Metamyelocyte IMG % and # Identification of Granulocytic cell line count of the overall myelemia Prepared by L.Castellane

Methods & technologies IMmature Monocyte Monoblast Promonocyte IMM IMM % and # Identification of Monocytic cell line Count of the precursors of the monocytic line Prepared by L.Castellane

Methods & technologies IMmature Lymphocyte Lymphoblast Prolymphocyte IML IML % and # Identification of Lymphocytic cell line IML and ALY include all abnormal lymphocytic populations Prepared by L.Castellane

Methods & technologies Routine identification and quantification of 3 immature cell lines involved in leucopoiesis: Granulocytic line Monocytic line Lymphocytic line -> Reduction of the number of slide examinations -> Diagnostic and follow-up tool for rapid decision-making Prepared by L.Castellane

Methods & technologies 1- Priority alarms 2- Separation alarms ALY: (Atypical Lymphocytes) Atypical Lymphocytes Plasmocytes, hairy Cells... Ne: (Neutro-eosino) Hyper-segmented neutrophils Hypo-granular eosinophils... Mn: (Mono-neutro) Immature granulocytes Band cells... LIC: (Large Immature Cells) Blasts, myelocytes Promyelocytes Metamyelocytes... Nl: (Neutro-lympho) Hypo-segmented neutrophils Sezary cells, hairy cells... Prepared by L.Castellane

Methods & technologies 3- Zone alarms No: (Noise) Platelet aggregates, NRBCs Lysis resistant RBCs Ln: (Left-neutro) Cellular debris Ll, Ll1: (Left-lympho) Platelet aggregates, NRBCs Rn: (Right-neutro) Immature granulocytes Rm: (Right-mono) Large monocytes, blasts Prepared by L.Castellane

Methods & technologies CHRONIC MYELOID LEUKEMIA Pentra DF 120 result: NEU 25.4 % EOS 1.8 % LYM 5.1 % MON 8.6 % BAS 0.1 % IMG 49.3 % IMM 9.2 % IML 0.5 % ALY 1.3 % Prepared by L.Castellane

Methods & technologies ACUTE MONOBLASTIC & MONOCYTIC LEUKEMIA Pentra DF 120 result: NEU 11.1 % EOS 0.5 % LYM 9.3 % MON 47.9 % BAS 0.1 % IMG 4.1 % IMM 26.1 % IML 0.9 % ALY 1.1 % Prepared by L.Castellane

Methods & technologies T-CELL PROLYMPHOCYTIC LEUKEMIA Pentra DF 120 result: NEU 12.1 % EOS 0.4 % LYM 6.7 % MON 12.8 % BAS 0.4 % IMG 0.4 % IMM 2.0 % IML 7.4 % ALY 57.8 % Prepared by L.Castellane

Main features analysis Methods and technologies Pentra ML ABX Pentra DF 120 Main features analysis Methods and technologies Pentra ML Specs & functionality Prepared by L.Castellane

17 inch flat colour screen Windows XP CD-ROM burner Automatic rerun Specs & functionality Dedicated PC 17 inch flat colour screen Windows XP CD-ROM burner Automatic rerun Reflex testing Pre-diluted mode Cytology library Onboard user manual Prepared by L.Castellane

Mono or bi-directional connection: Specs & functionality Mono or bi-directional connection: ASTM format Transfer of Demographic data (blood type - man, woman, child) Tests requested (CBC, CBC/DIFF, SPS) Up to 3 ABX Hematology analyzers (Pentra range) can be connected Query mode Download capability Prepared by L.Castellane

User defined rules applied when : receiving the worklist, Specs & functionality User defined rules applied when : receiving the worklist, a sample has been analyzed. _ Rerun capability _ Reflex testing _ Automatic validation _ Messages, comments…. Bio-technical validation with : Patient history Delta check Result edition Manual entry Recalculation capability Prepared by L.Castellane

Bio-technical validation with : Result screens Bio-technical validation with : Patient report, run, re-run, patient history, graphs, alarms. All displayed on the same screen. Delta check Result edition Manual entry Recalculation capability 1- Title bar 2- Patient and Graphics area 3- Messages 4- Patient Comments 5- Technical Comments 6- Extended Diff 7- Result area 8- Report 9- Runs Prepared by L.Castellane

Hematovision IV included A cell cytology library Specs & functionality Hematovision IV included A cell cytology library Prepared by L.Castellane

ABX Pentra 120 series Prepared by L.Castellane

ABX Pentra 120 series Prepared by L.Castellane

Thank you Prepared by L.Castellane