ELECTRONIC ASSEMBLIES AND SOLDERING TECHNIQUE –PART II

Slides:



Advertisements
Similar presentations
BASIC HAND SOLDERING MULTICORE SOLDER
Advertisements

Threads and Fasteners Thread Symbols.
UVM CricketSat Assembly Manual. Getting Started Make a hard copy print out of the following page It will help you identify the proper components Place.
Assembly Manual Mike Fortney 04/09/2004 CricketSat Receiver.
Chapter 7 Dimensioning.
New USPS Postage Rates effective May 15, 2007 WSU Mailing Services Office of University Publishing.
CHAPTER 4 Dimensioning.
IPC COMPONENT PLACEMENT
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Electronics Merit Badge Class 4 5/17/2015Electronics Merit Badge Class National Scout Jamboree1.
Firestone Building Products EPDM Training. Membrane Attachment.
OSHA Office of Training & Education
OSHAX.org - The Unofficial Guide to the OSHA1 Stairways and Ladders.
Stairways and Ladders.
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
Development of Surfaces.
REINFORCED CONCRETE Reinforced concrete is a composite material which utilizes the concrete in resisting compression forces, and steel bars and/or.
Weld Types - Lap Weld UVU CRT Lap Weld  Many automotive structural panels are assembled using a lap joint.  Technicians must make test welds visually.
The printed circuit board (PCB) design
Multiview Drawing 5.00 Demonstrate orthographic projection techniques and principles as they apply to multiview drawings.
Dr. R. Ribeiro, Mechanical Engg. Dept. IITD
Dimensioning Dimensioning.
Area (geometry) the amount of space within a closed shape; the number of square units needed to cover a figure.
Dimensioning (WEEK 2).
General Tolerance and Hole Fit
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Dimensioning Dimensioning.
IPC Datum Features Datum features indicate the origin of a dimensional relationship between a toleranced feature and a designated feature or.
IPC RADIAL- COMPONENTS Angularity is required for clearance in the next higher assembly; or That edge of the body nearest the surface of the.
IPC Stress Relief Lands and terminals shall be located by design so that components can be mounted or provided with stress relief bends in.
Drawing Abilities Teacher
IPC-2221 Connectors and Interconnects
IPC In-Circuit Test Fixtures In-circuit test fixtures are commonly called bed-of-nails fixtures. A bed-of- nails fixture is a device with.
Dimensioning Composite Solids
IPC-2222 Thermal Relief in Conductor Planes
IPC Part Support All parts weighing 5.0 gm, or more, per lead shall be supported by specified means, which will help ensure that their soldered.
Reinforcement Information - Code
IPC Standard Surface Mount Requirements Automatic assembly considerations for surface mounted components are driven by pick-and- place machines.
The printed circuit board (PCB) design §PCB design is part of the design process of a product in electronics industry. §PCB is a piece of insulating plastic.
Drawing of bolt and nut.
Learning Objectives Define the following: Dimension line, Extension line, Reference dimension, and Leader Be able to understand the basic rules of dimensioning.
Dimensioning Standards and Techniques. Organizations for Dimension Standards American National Standards Institute – a U.S. organization that recommends.
# 23 SINGLE IMPLANT CASE Osteotomy Progression in Open Guide Sleeve
Learning Aid: Technical Terms for Describing Drawings
OSHA’s NEW Walking-Working Surfaces
Kursus “electronic assemblies & SOLDERING Technique”
Angles and Protractors
Drawing Abilities Teacher
IPC-A-610E SOLDERING.
Solenoid Yoke Door-Barrel Connection
Wicking: Requirements
BASIC HAND SOLDERING MULTICORE SOLDER  most common type for hand soldering has a composition of Tin (Sn60) and Lead (Pb40), with a diameter of 0.71 mm.
Chapter 3 DIMENSIONING Dimensioning refers to the act of giving dimensions. Dimension is a numerical value expressed in appropriate units of measurement.
Stick Together & Civil Structures
BIX In-Building Cross Connect system
Dimensioning 4-1) Detailed Drawings.
DIMENSION PLACEMENT By: Muhammad Zahid.
Mechanical Dimensions
Basic Dimensioning Practices
Lines used in drafting are lines whose appearance and meaning are determined by international agreements. Geometric Lines.
Design Intent Stephen H. Simmons TDR 200 Copyright - Planchard 2012.
DIMENSIONING Why do we need to dimension drawings?
CHAPTER 3 Dimensioning.
EET 323 – Electrical System Design Lecture 11: Panel-boards and Switch-boards Instructor: Radian Belu, PhD.
Chapter 10 Sheet Metal Design
Custom Switch and Value Added Capabilities
Mechanical Dimensions
IPC Compliance Testing (DPA) Methodology
Presentation transcript:

ELECTRONIC ASSEMBLIES AND SOLDERING TECHNIQUE –PART II NAME : MOHD ROSDAN BIN MOHAMAD E-MAIL : rosdan_Mohamad@psas.edu.my DATE : 4 MAC 2016 IPC-A-610E

Components are centered between their lands. 7 Through-Hole Technology 1. Component Mounting – Orientation – Horizontal Target - Class 1,2,3 Components are centered between their lands. Component markings are discernible. Nonpolarized components are oriented so that markings all read the same way (left- to-right or top-to-bottom). Acceptable - Class 1,2,3 Polarized and multilead components are oriented correctly. All components are as specified and terminate to correct lands. Nonpolarized components are not oriented so that markings all read the same way (left-to-right or top-to-bottom).

Component is not as specified (wrong part) (A). 7 Through-Hole Technology 1. Component Mounting – Orientation – Horizontal (cont.) Defect - Class 1,2,3 Component is not as specified (wrong part) (A). Component not mounted in correct holes (B). Polarized component mounted backwards (C).

Nonpolarized component markings read from the top down. 7 Through-Hole Technology 2. Component Mounting – Orientation – Vertical Target - Class 1,2,3 Nonpolarized component markings read from the top down. Polarized markings are located on top. Acceptable - Class 1,2,3 Polarized marking hidden. Nonpolarized component markings read from bottom to top. Defect - Class 1,2,3 Polarized component is mounted backwards.

Radial Leads – Horizontal 7 Through-Hole Technology 3. Radial Leads – Horizontal Target - Class 1,2,3 The component body is in flat contact with the board’s surface. Acceptable - Class 1,2,3 Component in contact with board on at least 1 side and/or surface. Note: When documented on an approved assembly drawing, a component may be either side mounted or end mounted. The body may need to be bonded or otherwise secured to the board to prevent damage when vibration and shock forces are applied. Defect - Class 1,2,3 Unbonded component body not in contact with mounting surface.

Process Indicator Class 2 Defect - Class 3 7 Through-Hole Technology 4. Component Mounting – Lead Forming – Bends Acceptable - Class 1,2,3 The inside bend radius of component leads meets requirements of Table 7-1. Table 7-1 Lead Bend Radius Lead Diameter (D) or Thickness (T) Minimum Inside Bend Radius (R) <0.8 mm [0.031 in] 1 D/T 0.8 mm [0.031 in] to 1.2 mm [0.0472 in] 1.5 D/T >1.2 mm [0.0472 in] 2 D/T Note: Rectangular leads use thickness (T). Acceptable - Class 1 Process Indicator Class 2 Defect - Class 3 Inside bend radius does not meet requirements of Table 7-1. Defect - Class 1,2,3

Lead damaged more than 10% 7 Through-Hole Technology 4. Component Mounting – Lead Forming – Bends (cont.) Acceptable - Class 1,2,3 Leads of through-hole mounted component extend at least 1 lead diameter or thickness but not less than 0.8 mm [0.031 in] from the body, solder bead, or lead weld. Figure 7-10 Solder bead Weld Acceptable - Class 1 Process Indicator – Class 2 Defect - Class 3 Lead bend of through-hole mounted component is less than 1 lead diameter or 0.8 mm [0.031 in], whichever is less, from the component body, solder bead Defect - Class 1,2,3 Lead damaged more than 10%

Axial Leaded – Horizontal 7 Through-Hole Technology 5. Axial Leaded – Horizontal Target - Class 1,2,3 The entire body length of the component is in contact with the board surface. Components required to be mounted off the board are at least 1.5 mm [0.059 in] from the board surface.

Axial Leaded – Vertical 7 Through-Hole Technology 6. Axial Leaded – Vertical Target - Class 1,2,3 The clearance (C) of the component body or weld bead above the land is 1 mm [0.039 in]. The component body is perpendicular to the board. The overall height does not exceed maximum design height requirements (H). Acceptable - Class 1,2,3 The component or weld bead clearance (C) above the land meets the requirements of Table 7-2. The angle of the component lead does not cause a violation of minimum electrical clearance. Table 7-2 Component to Land Clearance Class 1 Class 2 Class 3 C (min) 0.1 mm [0.0039 in] 0.4 mm [0.016 in] 0.8 mm [0.031 in] C (max) 6 mm [0.24 in] 3 mm [0.12 in] 1.5 mm [0.059 in]

6. Axial Leaded – Vertical (cont.) 7 Through-Hole Technology 6. Axial Leaded – Vertical (cont.) Acceptable - Class 1 Process Indicator - Class 2,3 The component or weld bead clearance (C) is greater than the maximum given in Table 7-2 The component or weld bead clearance (C) is less than the minimum given in Table 7-2. Defect - Class 1,2,3 Components violate minimum electrical clearance.

7. Radial Leads – Vertical 7 Through-Hole Technology 7. Radial Leads – Vertical Target - Class 1,2,3 Component is perpendicular and base is parallel to board. Clearance between base of component and board surface/ land is between 0.3 mm [0.012 in] and 2 mm [0.079 in]. Figure 7-33 Acceptable - Class 1,2,3 Component tilt does not violate minimum electrical clearance. C Process Indicator - Class 2,3 Space between component base and board surface/land is less than 0.3 mm [0.012 in] or more than 2 mm [0.079 in] Defect - Class 1,2,3 Violates minimum electrical clearance. Note: Some components cannot be tilted due to mating requirements with enclosures or panels, for example toggle switches, potentiometers, LCDs, and LEDs.

Leads are formed to provide stress relief. 7 Through-Hole Technology 8. Component Mounting – Lead Forming – Stress Relief Acceptable - Class 1,2,3 Leads are formed to provide stress relief. Component lead exiting component body is approximately parallel to major body axis. Component lead entering hole is approximately perpendicular to board surface. Component centering may be offset as a result of the type of stress relief bend. Figure 7-13 Typically 4 - 8 wire diameters 1 wire diameter minimum 2 wire diameter minimum

Component Mounting – Lead Forming – Stress Relief (cont.) 7 Through-Hole Technology 8. Component Mounting – Lead Forming – Stress Relief (cont.) Acceptable - Class 1 Process Indicator - Class 2 Defect - Class 3 Lead bends less than 1 lead diameter or 0.8 mm [0.031 in] away from body seal. Defect - Class 1,2,3 Damage or fracture of component body-to- lead seal. No stress relief.

End is discernible in the solder.1 7 Through-Hole Technology 9. Wire/Lead Protrusion Table 7-3 Protrusion of Wires/Leads in Supported Holes Class 1 Class 2 Class 3 (L) min. End is discernible in the solder.1 (L) max.2 No danger of shorts 2.5 mm [0.0984 in] 1.5 mm [0.059 in] Acceptable - Class 1,2,3 The leads protrude beyond the land within the specified minimum and maximum (L) of Table 7- 3, provided there is no danger of violating minimum electrical clearance. The leads meet the design length (L) requirements when specified.

Standoff step on all leads rests on the land. 7 Through-Hole Technology 10. Devices and Sockets Target - Class 1,2,3 Standoff step on all leads rests on the land. Lead protrusion meets requirements. Acceptable - Class 1,2,3

Devices and Sockets (cont.) 7 Through-Hole Technology 10. Devices and Sockets (cont.) Defect - Class 1,2,3 Lead protrusion does not meet acceptance requirements

Component Mounting – Leads Crossing Conductors 7 Through-Hole Technology 11. Component Mounting – Leads Crossing Conductors Acceptable - Class 1,2,3 Sleeve does not interfere with formation of the required solder connection (A). Sleeve covers area of protection designated (B). Defect - Class 2,3 Splitting and/or unraveling of sleeving (A). Defect - Class 1,2,3 Component leads and wires required to have sleeving are not sleeved. Damaged/insufficient sleeving does not provide protection from shorting. Sleeving interferes with formation of the required solder connection. A component lead crossing an electrically noncommon conductor violates minimum electrical clearance (B).

12. Component Mounting – Lead Forming – Damage 7 Through-Hole Technology 12. Component Mounting – Lead Forming – Damage Acceptable - Class 1,2,3 No nicks or deformation exceeding 10% of the diameter, width or thickness of the lead. Defect - Class 1,2,3 Lead is damaged more than 10% of the lead diameter or thickness. Lead deformed from repeated or careless bending.

13 Jumper Wires – Wire Routing 7 Through-Hole Technology 13 Jumper Wires – Wire Routing Target - Class 1,2,3 Wire routed shortest route. Wire does not pass over or under component. Wire does not cross component.