B. Sorazu, P. Fulda, B. Barr, A. Bell, C. Bond, L. Carbone, A

Slides:



Advertisements
Similar presentations
Stefan Hild, Andreas Freise University of Birmingham Roland Schilling, Jerome Degallaix AEI Hannover January 2008, Virgo week, Pisa Advanced Virgo: Wedges.
Advertisements

Stefan Hild for the GEO600 team October 2007 LSC-Virgo meeting Hannover Homodyne readout of an interferometer with Signal Recycling.
Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) HOMODYNE AND HETERODYNE READOUT OF A SIGNAL- RECYCLED GRAVITATIONAL WAVE DETECTOR.
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
FINESSE FINESSE Frequency Domain Interferometer Simulation Versatile simulation software for user-defined interferometer topologies. Fast, easy to use.
19. October 2004 A. Freise Automatic Alignment using the Anderson Technique A. Freise European Gravitational Observatory Roma
Dual Recycling for GEO 600 Andreas Freise, Hartmut Grote Institut für Atom- und Molekülphysik Universität Hannover Max-Planck-Institut für Gravitationsphysik.
Polarization Techniques for Interferometer Control Peter Beyersdorf National Astronomical Observatory of Japan LSC March 2002 Advanced Configurations LIGO-G Z.
Stefan Hild, Andreas Freise, Simon Chelkowski University of Birmingham GWADW, ELBA, May 2008 Virtual Interferometry for future GW detectors.
Thermally Deformable Mirrors: a new Adaptive Optics scheme for Advanced Gravitational Wave Interferometers Marie Kasprzack Laboratoire de l’Accélérateur.
Higher order laser modes in gravitational wave detectors
Stefan Hild, Andreas Freise, Simon Chelkowski University of Birmingham Roland Schilling, Jerome Degallaix AEI Hannover Maddalena Mantovani EGO, Cascina.
Stefan Hild, Andreas Freise, Simon Chelkowski University of Birmingham Roland Schilling, Jerome Degallaix AEI Hannover Maddalena Mantovani EGO, Cascina.
GWADW, May 2012, Hawaii D. Friedrich ICRR, The University of Tokyo K. Agatsuma, S. Sakata, T. Mori, S. Kawamura QRPN Experiment with Suspended 20mg Mirrors.
Stefan Hild 1ILIAS WG1 meeting, Cascina, November 2006 Comparison of tuned and detuned Signal-Recycling Stefan Hild for the GEO-team.
GWADW 2010 in Kyoto, May 19, Development for Observation and Reduction of Radiation Pressure Noise T. Mori, S. Ballmer, K. Agatsuma, S. Sakata,
ANATAC Meeting Line Length Correction Status 2004-Apr-23.
Optical Configuration Advanced Virgo Review Andreas Freise for the OSD subsystem.
Optical readout for a resonant gw bar. Old setup.
Test mass dynamics with optical springs proposed experiments at Gingin Chunnong Zhao (University of Western Australia) Thanks to ACIGA members Stefan Danilishin.
Interferometer Control Matt Evans …talk mostly taken from…
Stefan Hild October 2007 LSC-Virgo meeting Hannover Interferometers with detuned arm cavaties.
Experimental test of higher-order LG modes in the 10m Glasgow prototype interferometer B. Sorazu, P. Fulda, B. Barr, A. Bell, C. Bond, L. Carbone, A. Freise,
Advanced VIRGO WG1: Status VIRGO, Cascina Andreas Freise University of Birmingham.
SQL Related Experiments at the ANU Conor Mow-Lowry, G de Vine, K MacKenzie, B Sheard, Dr D Shaddock, Dr B Buchler, Dr M Gray, Dr PK Lam, Prof. David McClelland.
T1 task- update Mike Plissi. 2 Motivation  Thermo-elastic noise is higher than the ‘intrinsic’ noise in crystalline materials  There are several sources.
Modulation techniques for length sensing and control of advanced optical topologies B.W. Barr, S.H. Huttner, J.R. Taylor, B. Sorazu, M.V. Plissi and K.A.
LISA October 3, 2005 LISA Laser Interferometer Space Antenna Gravitational Physics Program Technical implications Jo van.
Advanced Virgo Optical Configuration ILIAS-GW, Tübingen Andreas Freise - Conceptual Design -
Koji Arai – LIGO Laboratory / Caltech LIGO-G v2.
LIGO-G0200XX-00-M LIGO Scientific Collaboration1 First Results from the Mesa Beam Profile Cavity Prototype Marco Tarallo 26 July 2005 Caltech – LIGO Laboratory.
Quantum noise observation and control A. HeidmannM. PinardJ.-M. Courty P.-F. CohadonT. Briant O. Arcizet T. CaniardJ. Le Bars Laboratoire Kastler Brossel,
1 Thermal noise and high order Laguerre-Gauss modes J-Y. Vinet, B. Mours, E. Tournefier GWADW meeting, Isola d’Elba May 27 th – Jun 2 nd, 2006.
RSE Experiment in Japan Feb. 20 th, 2004 Aspen Meeting LIGO-G Z K.Somiya, O.Miyakawa, P.Beyersdorf, and S.Kawamura.
S. ChelkowskiSlide 1WG1 Meeting, Birmingham 07/2008.
AIGO 2K Australia - Italy Workshop th October th October 2005 Pablo Barriga for AIGO group.
Nov 3, 2008 Detection System for AdV 1/8 Detection (DET) Subsystem for AdV  Main tasks and requirements for the subsystem  DC readout  Design for: the.
S. ChelkowskiSlide 1LSC Meeting, Amsterdam 09/2008.
Einstein gravitational wave Telescope Which optical topologies are suitable for ET? Andreas Freise for the ET WG3 working group MG12 Paris.
Dual Recycling in GEO 600 H. Grote, A. Freise, M. Malec for the GEO600 team Institut für Atom- und Molekülphysik University of Hannover Max-Planck-Institut.
Stefan Hild 111th WG1 meeting, Hannover, January 2007 DC-Readout for GEO Stefan Hild for the GEO-team.
Laguerre-Gauss Modes for Future Gravitational Wave Detectors Keiko Kokeyama University of Birmingham 2 nd ET Annual Erice, Sicily, Italy
17/05/2010A. Rocchi - GWADW Kyoto2 Thermal effects: a brief introduction  In TM, optical power predominantly absorbed by the HR coating and converted.
SQL Related Experiments at the ANU Conor Mow-Lowry, G de Vine, K MacKenzie, B Sheard, Dr D Shaddock, Dr B Buchler, Dr M Gray, Dr PK Lam, Prof. David McClelland.
Advanced Virgo: Optical Simulation and Design Advanced Virgo review Andreas Freise for the OSD Subsystem.
Numerical and experimental study of the mode tuning technique effects. Application to the cavity ring-down spectroscopy. J. Remy, G.M.W. Kroesen, W.W.
Optical Spring Experiments With The Glasgow 10m Prototype Interferometer Matt Edgar.
Monica VarvellaIEEE - GW Workshop Roma, October 21, M.Varvella Virgo LAL Orsay / LIGO CalTech Time-domain model for AdvLIGO Interferometer Gravitational.
The VIRGO detection system
FINESSE FINESSE Frequency Domain Interferometer Simulation Andreas Freise European Gravitational Observatory 17. March 2004.
Active Vibration Isolation using a Suspension Point Interferometer Youichi Aso Dept. Physics, University of Tokyo ASPEN Winter Conference on Gravitational.
Lessons from CLIO Masatake Ohashi (ICRR, The University of TOKYO) and CLIO collaborators GWADW2012 Hawaii 2012/5/16.
The cancelation of displacement- and frequency- noise using four mach-zehnder interferometer Keiko Kokeyama Ochanomizu University / NAOJ.
1 M. Granata, M. Barsuglia, C. Buy, R. Ward – GWADW 2010, Kyoto.
Interferometer configurations for Gravitational Wave Detectors
Advanced Virgo: Optical Simulation and Design
A look at interferometer topologies that use reflection gratings
LG MODES FOR THERMAL NOISE REDUCTION
Gingin Advisory Committee Meeting 08 Dec 2009
Thermal noise reduction through LG modes
Homodyne readout of an interferometer with Signal Recycling
Workshop on Gravitational Wave Detectors, IEEE, Rome, October 21, 2004
Flat-Top Beam Profile Cavity Prototype: design and preliminary tests
First Results from the Mesa Beam Profile Cavity Prototype
Thermal noise and high order Laguerre-Gauss modes J-Y. Vinet, B
LIGO Scientific Collaboration
A. Heidmann M. Pinard J.-M. Courty P.-F. Cohadon
Squeezed Light Techniques for Gravitational Wave Detection
The ET sensitivity curve with ‘conventional‘ techniques
Measurement of radiation pressure induced dynamics
Presentation transcript:

Experimental test of higher-order LG modes in the 10m Glasgow prototype interferometer B. Sorazu, P. Fulda, B. Barr, A. Bell, C. Bond, L. Carbone, A. Freise, S. Hild, S. Huttner, J. Macarthur, K. Strain

Introduction – Overview Motivation of the current work. Presenting Glasgow interferometric GW detector 10 m prototype. LG33 mode generation on the prototype’s input laser bench. Preliminary results. Conclusions.

Motivations Higher-order LG mode beams are being considered for implementation on future generations of GW interferometers. LG modes are expected to considerably reduce thermal noise (both mirror coating and substrate Brownian noise) in comparison with TEM00 beams [1,2,3]. Results from simulation work and benchtop experiments [3,4] on higher order LG mode interferometry encourage us to take the next step; testing in an environment similar to an interferometric GW detector. [1] B. Mours et al. Thermal noise reduction in interferometric gravitational wave antennas: using high order TEM modes, CQG 23, 5777, 2006 [2] J.-Y. Vinet On special optical modes and thermal issues in advanced gravitational wave interferometric detectors, Living Revs. Rel. 12(5), 2009 [3] S. Chelkowski et al. Prospects of higher-order Laguerre- Gauss modes in future gravitational wave detectors, Physical Review D 79,122002, 2009 [4] P. Fulda et al. Experimental demonstration of higher-order Laguerre-Gauss mode interferometry, Physical Review D 82, 012002, 2010

The Glasgow 10m Prototype Interferometer GEO-like infrastructure: Similar vacuum systems Triple stage GEO-suspensions Same local control Ideal test bed for advanced interferometry concepts (e.g. Signal recycling, optical spring). Fast turn around for rapid, small-scale tests Timely validation of various innovative technologies (e.g. higher order LG modes, diffractive interferometry) Excellent training for students and Postdocs

The Glasgow 10m Prototype Interferometer Thermal Noise Reduction Cavity Maximise potential of the Glasgow prototype by carrying out several strands of experiments in parallel: Direct measurement of thermal noise 3-mirror coupled cavity systems: Control strategies S.Huttner et al. Novel sensing and control schemes for a three-mirror coupled cavity, CQG 24, 3825, 2007. B. Barr et al. Optical modulation techniques for length sensing and control of optical cavities, Appl. Opt. 46, 2007. S. H. Huttner et al. Techniques in the optimization of length sensing and control systems for a three-mirror coupled cavity, CQG 25, 235003, 2008. Radiation pressure experiments Frequency reference for TN experiment

The Glasgow 10m Prototype Interferometer Thermal noise reduction cavity systems: Diffractive grating as cavity incoupler M.Edgar et al. Experimental demonstration of a suspended diffractively coupled optical cavity, Opt. Lett. 34, pp. 3184-3186, 2009. M.Edgar et al. Experimental demonstration of a suspended, diffractively coupled Fabry–Perot cavity, CQG 27, 084029, 2010. B. Barr et al.Translational, rotational and vibrational coupling into phase in diffractively- coupled optical cavities, accepted for publication Optics Letters. Waveguide mirror (First realization of a waveguide suspended cavity with a finesse of 800) D. Friedrich et al. Waveguide grating mirror in a fully suspended 10 m cavity, accepted for pub. Optics Exp. http://arxiv.org/abs/1104.2780 Thermal Noise Reduction Cavity Waveguide Cavity

The Glasgow 10m Prototype Interferometer Thermal Noise Reduction Cavity Thermal noise reduction cavity systems: Diffractive grating as cavity incoupler M.Edgar et al. Experimental demonstration of a suspended diffractively coupled optical cavity, Opt. Lett. 34, pp. 3184-3186, 2009. M.Edgar et al. Experimental demonstration of a suspended, diffractively coupled Fabry–Perot cavity CQG 27, 084029, 2010. B. Barr et al.Translational, rotational and vibrational coupling into phase in diffractively- coupled optical cavities, accepted for publication Optics Letters. Waveguide mirror (First realization of a waveguide suspended cavity with a finesse of 800) D. Friedrich et al. Waveguide grating mirror in a fully suspended 10 m cavity, accepted for pub. Optics Exp. http://arxiv.org/abs/1104.2780 Higher order LG modes

LG33 in the Glasgow 10m GW detector prototype Outcome of the successful ongoing collaboration with the University of Birmingham. Main aims of the experiment: Gain some experience in how to handle high order LG modes in a prototype environment. Study of interferometer control signals with high order LG modes. Locking a single 10m cavity on high order LG modes. Investigating effects from mode-degeneracy (see talk by C. Bond at Advanced det. Technologies session Amaldi 9 (2011), R. Adhikari at GWADW 2010 at Kyoto)

Some notes about mode - degeneracy Different mode orders are separated in cavities because the round trip Gouy phase for a mode = (order + 1) * Gouy phase Modes of the same order have the same round trip Gouy phase, therefore aren't separated in cavities. Coupling into other modes of the same order will lead, potentially, to different combinations of modes in the different arm cavities. In real cavities the modes are not perfectly degenerated, they have slightly different resonant frequencies due to experiencing a different average mirror curvature or cavity length. This leads to error signals with multiple zero crossings making it difficult to lock stably to one of this ‘pseudo’ degenerated modes. Here we show an example of such ‘pseudo’ degeneracy on a 3 mirror mode cleaner with astigmatism. Circulating Power PDH Error Signal Cavity tuning [deg] However, first simulations with mirror maps have shown that the expected range of the frequency splitting is much smaller than our 10m cavity line width. Therefore we do not expect to observe this phenomenon.

LG33 generation – Input Laserbench

LG33 generation – Input Laserbench

LG33 generation – Input Laserbench LG33 generation optics have four purposes: Generation of a LG33 mode from a laser emitted TEM00 mode. This is done with a diffractive optical element (DOE). Purification of the generated LG33 mode. By means of a linear modecleaner (LMC); 23 cm long planoconcave cavity with a finesse of 172 and 714MHz FSR. Adding phase modulation onto the beam for cavity lock. Through an EOM. Ensuring a good alignment of the prototype’s 10m cavity for the LG33 beam. For this we have a pick off path of the TEM00 that avoids the DOE and passes the LMC. TEM00 and LG33 share same eigenmode inside the LMC.

LG33 degradation through the Glasgow prototype After 1st MM lens Max. residual 0.18 Max. residual 0.30 After LMC Cavity misaligned End Mirror - transmission After 4 EOM crystals and FI Max. residual 0.50 Max. residual 0.33

Results – Locking onto high order LG modes 0th order 1st order Good cavity alignment as shown by the visibility of TEM00 mode resonance with respect to higher order one. Still see reasonable resonances but so far cavity power buildup is a factor 5 less. However, still the desired mode-order is dominant.

Examples of modes we were able to lock to

Results – High order modes resonance freq. split The resonance peak of the TEM00 mode shows a single peak...as expected.

Results – High order modes resonance freq. split Scanning several FSR for LG33 mode

Results – High order modes resonance freq. split Control signals (errorsignal, feedback signal and transmitted power) and cavity mode shape when locked onto the highest peak. During the video we intentionally gave longitudinal kicks to the mirrors to lock to different modes within the peak.

Plans for investigation of modes resonance freq. split Recording the mode shape of the transmitted beam with a high speed camera during the transition between the peaks of the frequency split modes. HS IR cameras are expensive so we built our own A commercial Casio Exilim... was chosen The camera was completely disassembled in order to remove the IR filter on the CCD The camera was assembled back and tested that it worked fine

Plans for investigation of modes resonance freq. split The HS camera provided a nice view of the multipeak resonance features. In these results we had cavity aligned to the order 7 mode, but freq. split resonance still there.

Plans for investigation of modes resonance freq. split The previous video was accompanied with a synchronized high resolution trace of the transmission PD DC level. We zoom onto one of the freq. split resonance features and attach video screenshots associated to each of the freq. splits: The video seems to confirm that the observed freq. splitting of the resonant peak is due to pseudo-degenerate modes. HS camera at 420 fps, trace recorded for 10 secs with 1 million points (video resolution is 0.0024secs). Notice that cavity is scanned changing the laser freq. not acting over the cavity mirrors. The LG mode seems to be in the background during the resonance although HG modes are dominating. The cavity or the beam appear to be astigmatic as shown by the 2 axis brightness change of the LG23 mode.

Plans for investigation of modes resonance freq. split Use a second auxiliary laser at freq. 1 FSR away from main laser. Freq. difference between laser stabilized with PLL servo. Lock cavity to aux. laser and modulate PLL LO to scan LG33 freq. relative to the locking laser. Technique suggested by Koji Arai et al. Precise measurement of long. and transv. mode spacings of an optical cavity using an auxiliary laser, G080467, 2008.

Conclusions Set up an experiment to test LG33 mode in a suspended 10m cavity featuring a nominal finesse of 600 (close to Advanced Detector config). Found it relatively easy to lock to order 9 modes. After some preliminary experimental test it may seem that the same setup that was adequate for stable locking to the TEM00 mode was not found to be adequate for the locking of the cavity to the LG33 mode. Further measurements will be carried out to allow confirmation. => So far no quantitative statement can be made about the expected mode degeneracy and associated problems Observation of multiples peaks around the order-9 resonance. So far unexplained. Simulations with real mirror imperfections and further measurements in progress. Outlook: Different reflectivity mirrors are available to investigate how unexplained effects scale with different cavity finesse.