Imaging and Quantification of Aortic Regurgitation after TAVI

Slides:



Advertisements
Similar presentations
Paul Nolan, Galway University Hospitals
Advertisements

Aortic Regurgitation 2D and Doppler Assessment
Trileaflet Aortic Valve. Management strategy for patients with chronic severe aortic regurgitation. Preoperative coronary angiography should be performed.
Cardiac Magnetic Resonance Versus Transthoracic Echocardiography for the Assessment and Quantification of Aortic Regurgitation in Patients Undergoing Transcatheter.
Aortic Regurgitation Mohammed AL Ghamdi.
INTERNATIONAL. CAUTION—For distribution only in markets where CoreValve has been approved. Not approved in the USA or Japan. ©Medtronic, Inc All.
ACC 2015 Jae K. Oh, MD On Behalf of the US CoreValve Investigators Remodeling of Self-Expanding Transcatheter Aortic Valve Is Responsible for Regression.
ACC 2015 Michael J Reardon, MD, FACC On Behalf of the CoreValve US Investigators A Randomized Comparison of Self-expanding Transcatheter and Surgical Aortic.
Long-Term Outcomes Using a Self- Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Deemed Extreme Risk for Surgery: Two-Year Results From.
How to Avoid Prosthesis-Patient Mismatch
University Heart Center Hamburg
TAVR Pearls Addressing the Shortcomings of the Current TAVR Generation
ECHOCARDIOGRAPHIC ASSESSMENT OF AORTIC REGURGITATION
Impact of Concomitant Tricuspid Annuloplasty on Tricuspid Regurgitation Right Ventricular Function and Pulmonary Artery Hypertension After Degenerative.
Prosthesis-Patient Mismatch in High Risk Patients with Severe Aortic Stenosis in a Randomized Trial of a Self-Expanding Prosthesis George L. Zorn, III.
Valve Regurgitation Echocardiographic Calculations Rami Khouzam, MD.
Hemodynamics: essentials for future TAVR and mitral valve disease Morton J. Kern, MD Professor of Medicine Chief of Cardiology Associate Chief Cardiology.
Date of download: 5/27/2016 Copyright © The American College of Cardiology. All rights reserved. From: Transcatheter Valve-in-Valve and Valve-in-Ring for.
KIMS Hospital – Hyderabad
Date of download: 6/29/2016 Copyright © The American College of Cardiology. All rights reserved. From: The Emerging Role of Exercise Testing and Stress.
Thanks ………… Echocardiographic Evaluation Of Prosthetic Cardiac Valves Dr Gaurav Kumar Chaudhary MD,DM( Cardiology) Assistant Professor Department of Cardiology.
Date of download: 7/6/2016 Copyright © The American College of Cardiology. All rights reserved. From: Bail-Out Alcohol Septal Ablation for Left Ventricular.
Date of download: 7/8/2016 Copyright © The American College of Cardiology. All rights reserved. From: A Bicuspid Aortic Valve Imaging Classification for.
Date of download: 7/10/2016 Copyright © The American College of Cardiology. All rights reserved. From: Echocardiography for Percutaneous Heart Pumps J.
1 Jeffrey J. Popma, MD Professor of Medicine Harvard Medical School Director, Interventional Cardiology Beth Israel Deaconess Medical Center Boston, MA.
TAVR in Patients With Chronic Kidney Disease
VSD post TAVR: Mechanisms, Presentation and Management
Gold Standard to Measure
Extending the Boundaries of TAVR: Future Directions
Is Transoesophageal Echocardiography during TAVR Essential?
The Lotus Device Design & FIM Experiences with a Repositionable Self Expanding Percutaneous Aortic Valve Ian T. Meredith MBBS, BSc(Hons), Ph.D, FRACP,
Relation of aortic regurgitation to all-cause mortality in the transcatheter aortic valve replacement (TAVR) as-treated population of the Placement of.
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
Optimizing Valve Sizing: Role of CT vs. Echo
Physiologic Lesion Assessment: Advantages and Pitfalls
Updates From NOTION: The First All-Comer TAVR Trial
Velocity-encoded imaging (phase contrast mapping) to assess trans- and paravalvular regurgitation after transcatheter aortic valve replacement (TAVR).
AORTIC STENOSIS.
Mitralign Program Update
TAVR-Endocarditis Tarek Chami, MD
TAVR Requirements for the Cath Lab
30-Day Safety and Echocardiographic Outcomes Following Transcatheter Aortic Valve Replacement with the Self-Expanding Repositionable Evolut PRO System.
Trans-Apical Aortic Valve Implant:
Early Outcomes with the Evolut R Repositionable Self-Expanding Transcatheter Aortic Valve in the United States Mathew Williams, MD, For the Evolut R US.
Optimizing Valve Sizing: Role of CT vs. Echo
Paravalvular Leaks Post-Transcatheter Aortic Valve Replacement
Early Recovery of Left Ventricular Systolic Function After CoreValve Transcatheter Aortic Valve Replacement Harold L. Dauerman, MD; Michael J. Reardon,
Table 1 : Baseline Characteristics
Direct Flow Medical Experience with a Conformable, Repositionable Retrievable Percutaneous Aortic Valve Reginald Low MD University of California, Davis.
TAVI „Catch me if you can!“
Dr M B Connellan Stellenbosch University
EVEREST II 5-Year Report and Beyond
Longevity of transcatheter and surgical bioprosthetic aortic valves in patients with severe aortic stenosis and lower surgical risk Lars Sondergaard,
Lessons from complications: Balloon-Expandable Edwards SAPIEN and the Self-Expanding Medtronic CoreValve Sunday February 21, :10 – 4:20 pm, Diplomat.
Department of Cardiology Bern University Hospital
CRT 2010 Washington DC, January 21, 2010
CoreValve Continued Access Study Shows Continued Improvement in 1-Year Outcomes With Self-Expanding Transcatheter Aortic Valve Replacement Steven J. Yakubov,
Second Generation Valves: What Will Be Different?
University Heart Center Hamburg
Balloon-Expandable Transcatheter Valve System : OUS Data
Circ Cardiovasc Imaging
Figure 5 TAVI with a self-expanding valve in
INOVATE-HF Trial design: Patients with heart failure (HF) were randomized to device implant for vagus nerve stimulation (n = 436) versus optimal medical.
Ao, aorta; AR, aortic regurgitation; CFD, color-flow Doppler; LV, left ventricle; LV EDP, left ventricular end-diastolic pressure; PW, pulse-wave; SBP,
Ανεπάρκεια Μιτροειδούς : Σταυρόλεξο για δυνατούς λύτες Ποσοτικοποίηση με Ηχωκαρδιογράφημα και ο ρόλος των δοκιμασιών φόρτισης Μαρία Μπόνου Διευθύντρια,
Nat. Rev. Cardiol. doi: /nrcardio
Cath-Lab Hemodynamics – I : Pressure tracings in the diseased heart
Megan Coylewright et al. JCIN 2015;8:
Prognostic significance of mild aortic regurgitation in predicting mortality after transcatheter aortic valve replacement  Brandon M. Jones, MD, E. Murat.
Philippe Pibarot et al. JIMG 2015;8:
Presentation transcript:

Imaging and Quantification of Aortic Regurgitation after TAVI Lutz Buellesfeld MD FSCAI FESC Department of Cardiology Bern University Hospital Switzerland

Lutz Buellesfeld, MD Consulting: Mitralign Medtronic CoreValve Edwards Lifesciences, LLC Abbott Vascular

Transesophageal echocardiography performed within 30 minutes of PHV implantation revealed … a circular stent geometry with a diameter of 21 mm, optimal PHV function with a mean gradient of 9 mm Hg, a valve area of 1.6 cm2 … , and a moderate paravalvular regurgitation through a nonapposed calcified commissure. Circulation. 2002;106:3006-3008.

Mechanisms of Paravalvular Aortic Regurgitation after TAVI Edwards CoreValve Buellesfeld L. JACC Intv. 2012;5(5):578-81

Mechanisms of Paravalvular Aortic Regurgitation after TAVI Mechanisms of Valvular Aortic Regurgitation after TAVI Leaflet-Immobility, -Destruction, Malexpansion

Incidence AR

Impact of AR on Mortality PARTNER A ADVANCE Registry France 2 Registry P<0.0001 Kodali SK et al. N Engl J Med. 2012;366:1686-95 CoreValve ADVANCE Registry: Presented at ACC 2012 FRANCE II Registry: Van Belle et al, TCT 2012

Invasive Hemodynamics Tools to Detect AR Invasive Hemodynamics Aortography Echocardiography

Angiographic Assessment Sellers Criteria Grade 0= No AR Grade 1= Jet to to LVOT disappearing with each systole Grade 2= Contrast filling of entire LV, but with less density compared to aorta Grade 3= Contrast filling of entire LV, with equal density compared to aorta Grade 4= Complete Opacification in diastole on the first beat with greater density compared to aorta Easy to perform Contrast media depending Qualitative assessment Good for the extremes… To document a perfect result or a substantial problem Supravalvular (2-3cm) shot of dye (20ml/s/40ml)

Echocardiographic Assessment Genereux P. JACC 2013: Paravalvular Leak After TAVR: A Comprehensive Review of the Literature

Echocardiographic Assessment Quantitative assessment Adds procedural complexity Gold standard for valve assessment LV Stroke Volume 56 ml RV Stroke Volume 43 ml Regurgitant volume 13 ml SV (LVOT) 56 ml Genereux P. JACC 2013: Paravalvular Leak After TAVR: A Comprehensive Review of the Literature

VARC 2 Criteria to Grade Postprocedural Aortic Regurgitation Mild Moderate Severe Semiquantitative Diastolic flow reversal Absent or brief early diastolic Intermediate Prominent, holodiastolic Circumferential extent <10% 10-29% ≥30% Quantitative Regurgitant volume <30 ml 30-59ml ≥60ml Regurgitant fraction <30% 30-49% ≥50% EROA (cm2) 0.10 cm2 0.10-0.29cm2 ≥0.30cm2 Kappetein J Am Coll Cardiol 2012;60:1438–54

Hemodynamic Assessment Normal Significant AR indicated by: Aortic diastolic pressure drop Low aortic diastolic pressure (DBP <40 mmHg) Loss of aortic dicrotic notch Increase of LVEDP Severe AR Reduced forward LV filling Low output Pulmonary congestion Coronary ischemia

Hemodynamic Assessment AR Index Diastolic Blood Pressure – LV Enddiastolic Pressure x 100 Systolic Blood Pressure Sinning J JACC 2012 Cutoff: 25

1-Year Mortality According to Severity of periprosthetic AR and the AR Index AR index cutoff value 3.5 (1.7–7.5) 0.001 Vasa-Nicotera M. J Am Coll Cardiol Intv 2012;5:858–65

Hemodynamic Assessment Simplified AR Index Diastolic Blood Pressure – LV Enddiastolic Pressure Cutoff: 18mmHg Patsalis P. EuroIntervention 2012 online ahead of print

Comparison of AR Index and Simplified AR Index (25) Simplified AR Index (<18mmHg) Pre 120/75 - 15 Post 120/40 - 30 50 60 8 10 Pre 80/45 - 15 Post 80/35 - 20 38 30 19 15 Pre 150/90 - 15 Post 150/50 - 25 50 75 17 25

Hemodynamic Assessment Integral AR Index Systolic Pressure Time Integral SPTI Diastolic Pressure Time Integral Diastolic Pressure Time Integral DPTI Systolic Pressure Time Integral Cutoff: 0.7 Patsalis P. Am J Physiol Heart Circ Physiol 2013 in-press

Hemodynamic Assessment Integral AR Index 0.7 Patsalis P. Am J Physiol Heart Circ Physiol 2013 in-press

Hemodynamic Assessment Integral AR Index Patsalis P. Am J Physiol Heart Circ Physiol 2013 in-press

Hemodynamic Assessment Normal Easy to perform Quantitative assessment Robust Severe AR

Multimodality Assessment Invasive Hemodynamics Aortography Echocardiography

New Generation Device Edwards SAPIEN 3 New Generation Device Sadra™ Medical Lotus Valve

Diameter Buellesfeld L. JACC Cardiovasc Intv 2013 Diameter Diameter

Thank you