Enron Generation Overview

Slides:



Advertisements
Similar presentations
The three most important considerations for development of wind farms are: LAND with good to excellent wind resource CONTRACT to sell electricity produced.
Advertisements

Dan Fox Senior Capacity Planning Consultant
Installing Generation - Behind the Meter Chris Rogers Sega, Inc. November 6, KMEA Annual Conference.
2011 ADC WINTER FORUM | PAGE 1 Navy Use of § 2922 Authority CAPT Clayton Mitchell NAVFAC Energy Office.
COMBINED HEAT & POWER J.R. Simplot Mountain Home, Idaho.
Why We Made the Decisions We Made and Where We Are in Building New Generation February 17, 2005 Prepared by Nilaksh Kothari, P.E. General Manager Manitowoc.
2001 & 2002 Energy Preparedness Tucson Electric Power February 16, 2001 Michael Flores, Manager Control Area Operations David Hutchens, Manager Wholesale.
Engineering Technology Division
Alternativenergy Flat Ridge Wind Facility Ted Hofbauer – Asset Manager.
Energy Business Solutions Michigan IRP Working Group Meeting June 10, 2005.
Boreal Renewable Energy Development Ferriter Scobbo & Rodophele PC Outback Engineering Richard C. Gross, Inc. March 12, 2009 Notus Clean Energy LLC Wind.
Solar Energy Services: Delivering Cost Effective Solar Power March 18, 2004 Claire Broido SunEdison, LLC (443) 226.
NASHVILLE ELECTRIC SERVICE | Association for Financial Professionals March 2012.
Avista’s Flexibility Overview James Gall Senior Power Supply Analyst Contact:
Power Plant BI POWER GENERATION Evolution of Plant Ownership From Regulated Era Regulated Utility Monopolies To “Partially” Deregulated Era Independent.
Proposed Generation Expansion Process For Review and Discussion March 1, 2011.
How the Transmission System Works Really William F. Reinke.
Southern California Edison The San Onofre Nuclear Generating Station April 14, 2011.
- DISCOVER THE DIFFERENCE - Florida’s Natural Energy - DISCOVER THE DIFFERENCE -
Bearcreek coal field, Montana, USA. This undervalued asset comprises over 389MM tons of high btu coal US COAL RESERVES AVAILABLE FOR JOINT VENTURE.
UTC STUDY OF DISTRIBUTED GENERATION AND RECOMMENDATIONS Presentation for the Washington Future Energy Conference October 19, 2011.
Enron North America. AC_01_ENA-1 Market-Making + Technology + Scale + Select Assets = Sustainable Competitive Advantage Enron North America North America.
. com Page 1 ENRON.COM Sketches for New Services Area May 18, 2000 *This presentation includes sample content from the Energy Transportation Services area.
Fountain Valley Power 225 MW Peaking Station for Public Service of Colorado.
September 26, 2000 Confidential & Proprietary Management Presentation Enron Generation Overview.
Pan-Canadian Wind Integration Study (PCWIS) Prepared by: GE Energy Consulting, Vaisala , EnerNex, Electranix, Knight Piésold Olga Kucherenko.
Brownsville Overview Management Presentation November 2000
Lincoln Energy Center Overview
Wind Project Ownership - An Investor Owned Utility Perspective John R
California Product Offerings
Enron Generation Overview - Pastoria
Enron Generation Overview - Pastoria
Who Is Southern Power? Stephen Gowland Business Development Manager
Natural Gas –generation intersection
Fuel Cost Components in the Fuel Adder
Enron Generation Overview
CCU Update integrated resource plan May 17, 2016
DRAFT- April 3, 2001 Restructuring Proposal to Brazos Electric Power Cooperative, Inc. April 6, 2001 This Information is CONFIDENTIAL Per Section 5 of.
Wheatland Overview Management Presentation October 2000
Enron Generation Overview
Enron Generation Overview
Proposed Sale of Enron North America’s/People’s Energy Joint Venture
Location of Enron Assets
Enron Generation Overview
Fuel Cost Components in the Fuel Adder
Enron Corp. Board of Directors Presentation
Wind Project Ownership - An Investor Owned Utility Perspective John R
NewCo’s Generation Overview
RMR Update November 6, /05/2002.
Gleason Overview Management Presentation October 2000
Insurance Company Partner Discussion Enron Price Uncertainty Products (“PUPs”) December 21, 1999.
Development of an Integrated Energy Market in Saudi Arabia
SkyGen Energy Revolving Credit Facility Indicative Proposal
Enron Generation Overview - Pastoria
Brownsville Overview Management Presentation December 2000
Kansas Renewable Energy & Energy Efficiency ’05 Conference
Enron Generation Overview
Presentation to the Enron Corp. Finance Committee
October 2000 Confidential & Proprietary Sales Points Gleason Overview.
Gleason Overview Management Presentation October 2000
Electricity Procurement Options
Basin Electric SPP Market Update
Malama Chileshe Energy Economist COMESA Secretariat
Marginal Cost Pricing: Why Is It Important? Have We Achieved It?
New England Gas Overview
Creating a Clean, Unbreakable Grid
City Council April 30, 2018 Item 13
SOLAR POWER – BOONVILLE WWTP CASE STUDY September 19, 2018 Charles R
New England Economic Partnership James Daly Vice President Energy Supply Energy Market Perspectives Reliable Energy, Competitive Prices and.
How Small Developers and EPC Contractors Can Add PPA Financing to their Arsenals John Langhus, VP Business Development Midwest Solar Expo 2019 New Energy.
Presentation transcript:

Enron Generation Overview September 25, 2000 Confidential & Proprietary Management Presentation Enron Generation Overview

Table of Contents - Peakers Generation Overview Key Sales Points Development History Equipment Overview Infrastructure Overview Construction Overview Contract Terms (EPC) & Warranty Provisions Performance Results Interconnection Agreements Gas Supply & Transportation Review of Power Markets Control Area Status Expansion / Conversion Details O&M Costs State/Local Taxes Legal/Lease Structures

Gleason Overview Project Gleason

Gleason Overview Generation Overview The plant is a 546 MW (nominal) natural gas-fired, simple cycle power generation facility (the “Gleason Plant”) owned by Gleason Power I, L.L.C., an indirect wholly owned subsidiary of Enron North America The Gleason Plant is located on an approximate 60 acre tract of land at 1156 James Mill road in Gleason, Tennessee The plant is located in the TVA subregion of SERC

Gleason Overview Key Sales Point The Gleason Plant has a “first-mover advantage opportunity” in a key Midwest market Plant provides geographic diversification with critical mass Target markets have historically experienced extreme power price volatility due to tight reserve margins, transmission constraints, and susceptibility to outages of large-scale units Ideally suited to capitalize on gas/power arbitrage opportunities Expansion potential at existing sites Conversion capability to combined cycle at all sites

Development/Construction Overview Gleason Overview Development/Construction Overview See Mitch for Timeline or Map

Gleason Overview Equipment Overview The Gleason Plant consists of one Westinghouse Model 501 FC gas turbine and two Westinghouse Model 501 FD gas turbines, rated at 182 MW and 182 MW, respectively (nominal) At 90 degrees Fahrenheit and at full operation, the Gleason Plant is able to achieve a net heat rate of approximately 10,900 Btu/kWh (HHV)

Gleason Overview Performance Results Add Mitch Robinson

Infrastructure Overview Gleason Overview Infrastructure Overview Add map of site

Gleason Overview Contract Terms May be taken out since it’s not relevant for Wheatland plant

Interconnection Agreements Gleason Overview Interconnection Agreements The Gleason Plant is interconnected to a 500 kV TVA line that traverses the site

Gas Supply & Transportation Gleason Overview Gas Supply & Transportation The Gleason Plant is permitted to use only natural gas as its fuel source The plant is interconnected to a interstate natural gas pipeline system which traverses the site and is owned and operated by ANR Pipeline Company (“ANR”) Gleason Power I, L.L.C. and ANR each own, operate and maintain specified portions of the interconnection facilities as defined in the facilities agreement The term of each of these agreements ends on February 28, 2010. The interruptible transportation service agreement and the interruptible gas parking and lending service agreement will continue on a month-to-month basis after February 28, 2010, until terminated by either party

Power Markets Opportunities Gleason Overview Power Markets Opportunities Gleason Power I, L.L.C. is qualified as a exempt wholesale generator (“EWG”) under the Public Utilities Holding Company Act of 1935, thus the plant has the authority to sell energy and capacity at market-based rates The Plant’s location in TVA and its access to the eastern U.S. electricity market provides sales opportunities in the wholesale power markets

Control Area Status The control area is designated ENGL Gleason Overview Control Area Status The control area is designated ENGL The Gleason Plant has been designated a control area in accordance with NERC policy

Expansion/Conversion Details Gleason Overview Expansion/Conversion Details The Gleason Plant has been designed to facilitate a future plant expansion or conversion to combined-cycle An interconnect request for conversion has been filed with TVA The stated net heat rate will go from 10,900 Btu/kWh to ______ The stated net output of the plant will go from 546 MW (nominal) to _____ The conversion of the Gleason plant will take approximately _____ Water availability? Permit timeline estimate?

Gleason Overview O&M Costs Variable O&M ($/MWh) of $1.50 includes estimates on water costs and variable maintenance expenditures Fixed O&M ($000) of $1,242 includes estimates of payroll expenses and other fixed O&M Major Maintenance ($/Start/Turbine) of $3,000 includes estimated accrual for future major maintenance on a per turbine basis, assuming 100 starts/year Estimated Owner’s Expense ($000) of $322 includes estimates of insurance, utilities, interconnection fees, gas pipeline metering costs and miscellaneous expenses Property Tax Liability ($000) of $92 may vary based on abatement programs and other local issues

Gleason Overview State/Local Taxes

Legal/Lease Structures Gleason Overview Legal/Lease Structures See Stuart Zisman

Wheatland Overview Project Wheatland

Wheatland Overview Generation Overview The plant is a 508 MW (nominal) natural gas-fired, simple cycle merchant generation facility (the “Wheatland Plant”) Owned by West Fork Land Development Company, L.L.C., a direct, wholly-owned subsidiary of Enron North America Located on an approximate 60-acre tract of land at 480 North Hall Road in Wheatland, Indiana Southern ECAR subregion of ECAR

Wheatland Overview Key Sales Point The Wheatland Plant has a “first-mover advantage opportunity” in a key Midwest market Plant provides geographic diversification with critical mass Target markets have historically experienced extreme power price volatility due to tight reserve margins, transmission constraints, and susceptibility to outages of large-scale units Ideally suited to capitalize on gas/power arbitrage opportunities Expansion potential at existing sites Conversion capability to combined cycle at all sites

Development/Construction Overview Wheatland Overview Development/Construction Overview See Mitch for Timeline or Map

Wheatland Overview Equipment Overview Consists of four Westinghouse Model 501 D5A gas turbines, each rated at approximately 127 MW (nominal) At 90 degrees Fahrenheit and at full load, the Wheatland Plant is able to achieve a net heat rate of approximately 11,500 Btu/kWh, HHV, and a net capacity of approximately 480 MW Approximately 450 gpm water usage during operation. Water is supplied by an owned lake, adjacent to the site

Wheatland Overview Performance Results See Mitch Robinson

Infrastructure Overview Wheatland Overview Infrastructure Overview Add map and 100 feet overview of facility, pipeline, water

Wheatland Overview Contract Terms May be taken out since it’s not relevant for Wheatland plant

Interconnection Agreements Wheatland Overview Interconnection Agreements Interconnected to two 345 kV lines. The plant has an interconnect agreement with both Cinergy Services Inc. (“Cinergy”), and Indianapolis Power & Light (“IPL”). With the dual interconnect, the plant has the option of dispatching into the Cinergy or IPL systems Both Cinergy and IPL allow scheduling of energy into and out of each control area, giving the Wheatland Plant the option of generating power or filling the scheduled energy delivery from the market when market economics warrant. This enables playing day ahead vs intra-day hourly market to maximize optionality This added flexibility ensures that the plant is reserved for operation only during periods of economic dispatch

Gas Supply & Transportation Wheatland Overview Gas Supply & Transportation Permitted to use natural gas as its fuel source Interconnected to Midwestern Gas Transmission Company (“Midwestern Gas”), a natural gas pipeline system owned by Tennessee Gas Pipeline Company The term of the interruptible gas transportation agreement and associated transportation rate began on April 1, 2000, continues through March 31, 2008 and will continue on a month-to-month basis until terminated upon thirty days notice by either party Gas can be purchased at Chicago city-gate hub or from Gulf Coast

Power Markets Opportunities Wheatland Overview Power Markets Opportunities West Fork Land Development Company, L.L.C., is qualified as an EWG, and has the authority to sell energy and capacity at market-based rates. The Wheatland Plant’s location in Southern ECAR, and its access to the eastern U.S. electricity market will provide sales opportunities in the wholesale power markets.

Wheatland Overview Control Area Status The control area is designated ENWI and ENWC. The Wheatland Plant has been designated as two control areas in accordance with NERC policy What is the benefit of having control area?

Expansion/Conversion Details Wheatland Overview Expansion/Conversion Details The Wheatland Plant has been designed to facilitate a future expansion or conversion to combined-cycle The stated net heat rate will go from 11,500 Btu/kWh to ______ The stated net output of the plant will go from 508 MW (nominal) to ____ The conversion of the Gleason plant will take approximately _____ Water availability? Permit timeline estimate?

Wheatland Overview O&M Costs Variable O&M ($/MWh) of $3.00 includes estimates on water costs and variable maintenance expenditures Fixed O&M ($000) of $1,516 includes estimates of payroll expenses and other fixed O&M Major Maintenance ($/Start/Turbine) of $1,500 includes estimated accrual for future major maintenance on a per turbine basis, assuming 100 starts/year Owner’s Expense ($000) of $306 includes estimates of insurance, utilities, interconnection fees, gas pipeline metering costs and miscellaneous expenses Property Tax Liability ($000) of $203 may vary based on abatement programs and other local issues

Wheatland Overview State/Local Taxes See Patrick Malloy’s Group

Legal/Lease Structures Wheatland Overview Legal/Lease Structures See Stuart Zisman

Project Lincoln Center Lincoln Center Overview Project Lincoln Center

Lincoln Center Overview Generation Overview The plant is a 656 MW (nominal) natural gas-fired, simple cycle power generation facility (the “Lincoln Energy Center”) Owned by Des Plaines Green Land Development, L.L.C., an indirect wholly owned subsidiary of Enron North America The Lincoln Energy Center is located on 50 acres of land at 27155 South Kankakee Street in Manhattan, Illinois The site sits directly across from the Commonwealth Edison Wilton Center substation (“ComEd Substation”)

Lincoln Center Overview Key Sales Point The Lincoln Center Plant has a “first-mover advantage opportunity” in a key Midwest market Plant provides geographic diversification with critical mass Target markets have historically experienced extreme power price volatility due to tight reserve margins, transmission constraints, and susceptibility to outages of large-scale units Ideally suited to capitalize on gas/power arbitrage opportunities Flexible gas arrangements in Chicago area allow access to ANR Pipeline Company and Northern Border Pipeline Company Expansion potential at existing sites Conversion capability to combined cycle at all sites

Development/Construction Overview Lincoln Center Overview Development/Construction Overview NEPCO, an indirect wholly owned subsidiary of Enron Corp., designed and constructed the facility See Mitch for Timeline or Map

Lincoln Center Overview Equipment Overview The Lincoln Energy Center consists of eight General Electric Model 7EA gas turbines, each rated at approximately 82 MW (nominal) At 90 degrees Fahrenheit and at full operation, the plant is able to achieve a net heat rate of approximately 11,900 Btu/kWh (HHV)

Lincoln Center Overview Performance Results (See Mitch Robinson)

Infrastructure Overview Lincoln Center Overview Infrastructure Overview Add map of site

Lincoln Center Overview Contract Terms Do we want to include specifics about the Com Ed contract?

Interconnection Agreements Lincoln Center Overview Interconnection Agreements The Lincoln Energy Center is interconnected directly to the ComEd Substation at the 345 kV level The ComEd Substation has five transmission lines to which it is connected: three 345 kV lines (ComEd) and two 765 kV lines (AEP) Each of the 765 kV lines has significant available transmission capacity during periods of peak load In addition to the direct access to Commonwealth Edison's service territory, the ComEd Substation has direct access to eastern markets (such as AEP) via the 765 kV line

Gas Supply & Transportation Lincoln Center Overview Gas Supply & Transportation The term of the interruptible gas transportation agreement began on March 1, 2000 and continues until February 28, 2002 The plant is interconnected to a natural gas pipeline system owned by Northern Border Pipeline Company (“Northern Border”) Des Plaines Greenland Development, L.L.C. and Northern Border each own, operate and maintain specified portions of the interconnection facilities as defined in the interconnect agreement

Power Market Opportunities Lincoln Center Overview Power Market Opportunities Des Plaines Green Land Development, L.L.C. is qualified as an EWG, and has the authority to sell energy and capacity at market-based rates Pursuant to a limited-term contractual agreement, the owner of the Lincoln Energy Center will be obligated to sell capacity and energy to a third party

Lincoln Center Overview Control Area Status The control area is designated ENLC. The Lincoln Energy Center has been designated a control area in accordance with NERC policy Control Area designation is valuable for point to point power sales, scheduling of power, and parking and hubbing

Expansion/Conversion Details Lincoln Center Overview Expansion/Conversion Details The Lincoln Energy Center has been designed to facilitate a future expansion or conversion to combined-cycle The stated net heat rate will go from 11,900 Btu/kWh to ______ The stated net output of the plant will go from 656 MW (nominal) to ____ The conversion of the Gleason plant will take approximately _____ Water availability? Permit timeline estimate?

Lincoln Center Overview O&M Costs Variable O&M ($/MWh) of $2.00 includes estimates on water costs and variable maintenance expenditures Fixed O&M ($000) of $1,449 includes estimates of payroll expenses and other fixed O&M Major Maintenance ($/Start/Turbine) of $1,000 includes estimated accrual for future major maintenance on a per turbine basis, assuming 100 starts/year Owner’s Expense ($000) of $401 includes estimates of insurance, utilities, interconnection fees, gas pipeline metering costs and miscellaneous expenses Property Tax Liability ($000) of $334 may vary based on abatement programs and other local issues

Lincoln Center Overview State/Local Taxes See Patrick Malloy’s Group

Legal/Lease Structures Lincoln Center Overview Legal/Lease Structures See Stuart Zisman