Screening for Critical Congenital Heart Defects with pulse oximetry:

Slides:



Advertisements
Similar presentations
Screening in arterial disease: ethical and methodological issues P Lacroix and V Aboyans.
Advertisements

Quad Network Study Day Anju Singh, SV Rasiah, Andy Ewer 29/11/2012.
Copyright restrictions may apply JAMA Pediatrics Journal Club Slides: Potential Impact of CCHD Screening Peterson C, Ailes E, Riehle-Colarusso T, et al.
Congenital Heart Disease in Neonates EGM Hoosen Paediatric Cardiology Inkosi Albert Luthuli Central Hospital.
Is it True? Evaluating Research about Diagnostic Tests
Newborn Screening for Critical Congenital Heart Disease
Screening for Critical Congenital Heart Disease using Pulse Oximetry Legislative Advocacy Anoop Rao PGY2, Pediatrics Image
High Sensitivity Troponin
John R. Phillips, M.D. Associate Professor of Pediatrics
Postmortem examination of human fetal hearts at or below 20 weeks’ gestation: a comparison of high-field MRI at 9.4 T with lower-field MRI magnets and.
IN THE NAME OF GOD. CRITICALLY APPRAISED TOPIC If there is a Non-invasive prenatal testing for aneuploidies with low FPR at first trimester? If we can.
Pulse oximetry screening for congenital heart disease. Does it work? Is it worth it?
Critical Congenital Heart Disease Screening Saving Lives One Infant at a Time Christina Rust, MSN, RN.
Newborn Screening for Critical Congenital Heart Defects by Pulse Oximetry Fall CME Course 2012 Robert Jansen, MD St. Vincent Women’s Hospital.
Information Mastery: A Practical Approach to Evidence-Based Care Course Directors: Allen Shaughnessy, PharmD, MMedEd David Slawson, MD Tufts Health Care.
First Trimester Screening
2014 Summit Co-Convener:Founder: Patient Safety Science & Technology Summit 2014.
Pulse Oximetry screening for Cardiac malformations in the neonate Majd Abu-Harb September 2014.
Parental Satisfaction and Anxiety Following Newborn Hearing Screening Referrals in Utah Linda D. Goetze, Catherine C. Groseclose, Scott Grosse, Karl R.
Bob Bowman, MS Director of Genomics & Newborn Screening Indiana State Department of Health.
Child Health Eight week check Elaine Burfitt July 2010.
© The Children's Mercy Hospital, /14 Critical Congenital Heart Disease (CCHD) Meagan Dorton, MSN, MBA, RN-CPN Pulse Oximetry Screening for Detecting.
Pompe Disease Evidence Evaluation Michael Watson, PhD, on behalf of Piero Rinaldo, MD, PhD, and the Decision-Making Workgroup October 1, 2008.
I have no relevant financial relationships with the manufacturers of any commercial products and/or provider of commercial services discussed in this CME.
SCH Journal Club Use of time from fever onset improves the diagnostic accuracy of C-reactive protein in identifying bacterial infections Wednesday 13 th.
EVALUATING AN EHDI SYSTEM: PARENT SURVEY PROJECT Vickie Thomson, MA State EHDI Coordinator Colorado Department of Public Health and Environment Janet DesGeorges.
Pulse Oximetry Screening for Critical Congenital Heart Disease (CCHD): The Wisconsin Experience Region IV Genetics Meeting September 11, 2012 Sharon Fleischfresser.
Why? 1 in 100 newborns have congenital heart defects 25% of all CHD are critical (CCHD) requiring intervention in the.
Congenital Heart Disease in South Texas Nadine Aldahhan, D.O.; Cherie Johnson, M.D., FACOG, MMM; Priscilla Gutierrez, RDMS, RDCS, RVT Christus Spohn Family.
Telephonic survey of the use of pulse oximetry as part of routine baby checks S Goyal, S Sen.
Evelina London Child Health Programme Integrating services Claire Lemer 29 th April 2014.
Hypoxic-Ischaemic Encephalopathy (HIE) in Wales R Adappa.
Recognition of Congenital Heart Disease Prenatal and newborn M. Beth Goens, MD Pediatric Cardiology University of New Mexico.
a systematic review and meta-analysis
Public Health England leads the NHS Screening Programmes
Screening for Life 2017.
NHS RightCare scenario: Getting the dementia pathway right
Working Strategies of Chinese Newborn Healthcare
Evaluation and Treatment of Children with Bronchiolitis in the Emergency Department Suspected bronchiolitis: Otherwise healthy child < 24 months of age.
Lorraine Freed Garg, MD, MPH Consultant in Public Health
Philippa Clery & Megan Collins
Disclaimer The Canadian Cardiovascular Society (CCS) welcomes reuse of our educational slide deck for medical institution internal education or training.
Electronic Prescribing in Hospitals Moving Forward
Class session 7 Screening, validity, reliability
Cost Effective Use of Troponin to Rule Out Acute Coronary Syndrome
Screening Hips of Newborns In Scotland
FAMILY MEDICINE AND LABORATORY TESTS Elham
Echocardiograms in syncope work-up
Intensive Observation Unit Careggi University Hospital, Firenze Italy
Rapid access diagnostic pathway for suspected HF in primary care: The first 3 months... Dr Alan Japp Dr Sara Jenks Dr Clare McRae Dr Sebastian Peter.
Evaluation and Treatment of Children with Bronchiolitis in the Emergency Department Suspected bronchiolitis: Otherwise healthy child < 24 months of age.
Factors that Influence Hospital Screening Programs
Assessment of Hypoxaemia
Incidental Detection of cardiac murmurs
Blindness separates people from things.
Levine RA, DO. Miladinovic B, PhD. Nardell K, MD. Galas J, MD
Reduction in Infant Cardiac Deaths in US States Implementing Policies to Screen Newborns for Critical Congenital Heart Disease Matthew Oster, MD, MPH Washington,
Assessment of Hypoxaemia
Gerard R. Martin, MD Medical Director, Global Services
How Structured Mortality Reviews Can Improve Quality of Care
Principal recommendations
Public Health England leads the NHS Screening Programmes
How will the NHS Long Term Plan work in our community?
Fetal cardiology service evaluation Antenatal diagnosis rate 2017
Effects of parental smoking on sleeping heart rate in infants who have developed an adult-like night time body temperature pattern. Effects of parental.
Flow chart showing the signs exhibited in the first days of life in the 50 cases of congenital cardiac malformation. Flow chart showing the signs exhibited.
Paediatric Sepsis Screening in the Emergency Department
NHS Long Term Plan: Rapid Diagnostic Centres (RDC) The SWAG Approach
Shortness of breath & the child with wheeze
Flow chart showing how the babies with low saturation and those with congenital cardiac malformation were processed. Flow chart showing how the babies.
Presentation transcript:

Screening for Critical Congenital Heart Defects with pulse oximetry: UK perspective Andrew Ewer Professor of Neonatal Medicine University of Birmingham UK Neonatologist, Birmingham Women’s Hospital 1

No conflict of interest to declare No payments or honoraria from any oximeter manufacturers No financial interests in any oximeter manufacturers

Pulse oximetry screening Rationale Hypoxaemia (low saturations) present in the majority of critical CHD (CCHD) Frequently clinically undetectable Pulse oximetry may detect babies with CCHD early, before they collapse

Pulse oximetry screening 8 studies - 35 960 patients Small numbers of patients, low prevalence of CCHD, methodological variations More high quality studies (in larger study populations) needed to precisely define test accuracy

Pulse oximetry studies 2009 - 2012

Pulse oximetry studies 2009 - 2012 Granelli – Sweden, (BMJ 2009) [>24 hrs, Pre/post ductal] Riede – Germany, (EJP 2010) ) [>24 hrs, Post ductal only] Ewer – UK, (Lancet 2011) ) [<24 hrs, Pre/post ductal] Turska−Kmieć – Poland, (Kardiologia Polska 2012) [<24 hrs, Post ductal only]

Detection of significant non-cardiac disease an important additional finding in all studies (28-70% of false positives)

Further work Pulse oximetry screening Is acceptable to parents and staff Anxiety not increased in false positives Is cost-effective in an NHS setting

2nd May 2012 13 studies 229 421 patients (c.f. 8 studies, 36 000 pts) Overall sensitivity 76.5% (95% CI 67.7% - 83.5%) Overall specificity 99.9% (99.7% -99.9%) False positive rate 0.14% (0.06 - 0.33) (FPR <24 hrs 0.5%. FPR >24 hrs 0.05%) (Did not include full Polish study)  

…surely the question now is not ‘should pulse oximetry screening be introduced?’ but ‘why should such screening not be introduced more widely?’ Lancet 2012;279:2401.

Pre and post-ductal saturations Sensitivity for CCHD – 83.6% April 2014   120 707 babies screened Pre and post-ductal saturations Sensitivity for CCHD – 83.6% False positive rate 0.3%

‘Further trials are unnecessary. Now is the time for professional bodies to review the evidence and consider a pulse oximetry screening protocol that best suits their requirements’ Ewer AK. Lancet 2014;384:725-6.

How should screening be done?

Screening protocols Pre and post or post-ductal only? Early or late screening? (<24 hrs or >24 hrs)

Pre and post-ductal vs Post-ductal No difference in sensitivity in meta-analysis Pre/post consistently identifies CCHD which would have been missed by post-ductal Granelli – 1 CCHD Ewer – 3 CCHDs Equivalent to 7 CCHDs per 100 000 births

Early or late screening (<24 or >24hrs) Most babies have ‘normal’ sats within 2 hr FP lower if PO screening >24 hr 0.05 vs 0.5%

CCHD presenting before screening Later screening studies report 50% of CCHD babies presented before screening1,2 Up to 10% present with collapse in hospital 1 Granelli BMJ 2009 2. Riede EJP 2010

CCHD presenting before screening New Jersey experience – 2011 -2012 72 694 babies screened – FP rate 0.04% but only 3 CCHDs identified1 Not specified but likely many CCHDs presented before screening (70-140 CCHD expected) Garg et al Pediatrics 2013

BWH screening programme 2010-2013 (40 months) Our experience in UK Birmingham Women’s Hospital

Most babies screened <12 hrs (mean age 7 hrs) Total Livebirths: 25 859 Most babies screened <12 hrs (mean age 7 hrs) Test positive pulse oximetry: 208 0.8% of all livebirths - Just >1 admission a week Congenital heart defects identified: 17 Critical CHD: 9 [+2FNs] Serious CHD: 3 Significant CHD: 5 55 pneumonia, 30 sepsis, 12 PPHN. Only 43 (21%) were healthy (True FPs) Singh, Rasiah, Ewer Arch Dis Child FN 2014;99:F297-F302.

Echocardiograms Echos performed for test +ve pulse Ox: 61/208 (29%) Abnormal Echos: 29/61 (48%)

Murmurs and echocardiography 3 year data from Birmingham Women’s Hospital 205 echos for babies with murmur 123 (60%) no significant abnormality 72 (35%) septal defects 2 (1%) CCHD – 1 CCHD/100 scans [PulseOx 9/61 (15%) CCHD] – 1 CCHD/6.5 scans Singh A et al. Acta Paed 2012;101:1651-2227.

No baby should have unexplained persistent hypoxaemia False positives Need to consider trade off between false positive rate and timely diagnosis Also… Earlier diagnosis of respiratory/infective cases Increasing discharges within 24 hours False positives are babies with low oxygen levels No baby should have unexplained persistent hypoxaemia

UK pilot - Methods 15 acute Hospitals participated over 6 months 1st Jul 2015 – 31st Dec 2015 - rural MLU to tertiary centres (incl. homebirths)

UK Newborn Pulse Oximetry Screening Pilot Pathway Newborn Pulse Oximetry Screening Pilot Stakeholders Meeting

US algorithm UK algorithm

UK pilot 32 836 babies screened 239 test positives (0.73%) 14 CHD (8 CCHD) – [2 FNs] 82 significant non-cardiac disease

PO screening vs. Hearing screening UK experience - screening well babies Hearing* PulseOx(BWH) PulseOx(UK) Referral rate 2.2% 0.8% 0.73% Target condition pick-up** 7 3.4 2.4 False positives† 213 80 70 **Per 10 000 tests (60 w/ sig. illness) (25 w/ sig. illness) *Wood, Sutton & Davis. Int J Audiol 2015;54:353–8

Summary Pulse oximetry screening is feasible, acceptable, cost-effective and reduces the diagnostic gap for CCHD. Most appropriate algorithm is likely to be refined with national input from national datasets and may be adjusted according to local circumstances

Reviews and commentaries Ewer AK. How to develop a business case to establish a neonatal pulse oximetry screening programme for screening of congenital heart defects. Early Hum Dev. 2012;88:915-9. Ewer AK. Review of pulse oximetry screening for critical congenital heart defects. Current Opinions in Cardiology 2013;28:92-6. Ewer AK. Pulse oximetry screening for critical congenital heart defects. Should it be routine? Arch Dis Child Fetal and Neonatal Ed 2014;99:F93-F95. Ewer AK. Pulse oximetry screening: do we have enough evidence now? Lancet 2014; 384: 725-26. Ewer AK. Evidence for CCHD screening and its practical application using pulse oximetry. Early Hum Dev 2014;90:suppl 2 S19-21. Narayen IC, Blom NA, Ewer AK, Vento M, Manzoni P, te Pas AB. Aspects of pulse oximetry screening for critical congenital heart defects: when, how and why. Arch Dis Child Fetal Neonatal Ed 2016;101:F162-F167. Ismail AQ, Cawsey M, Ewer AK. Newborn pulse oximetry screening in practice. Arch Dis Child Educ Prac Ed. 2016 Aug 16. doi:1136/archdischild -2016-311047. [Epub ahead of print]. Ewer AK Pulse oximerty screening for critical congenital heart defects: medical aspects. Am J Perinatol 2016; Ewer AK, Martin GR. Newborn pulse oximetry screening: which algorithm is best? Pediatrics 2016;138(5):e 20161206. a.k.ewer@bham.ac.uk Happy to send copies to anyone who wants them. Please email me.