Crab cavities Cryogenics progress for the SPS

Slides:



Advertisements
Similar presentations
Current status Arkadiy Klebaner November 21, 2012
Advertisements

For more information, please contact 19/11/2010 EN/CV/DC Chiller design and purchase by Elena Perez Rodriguez.
Large-capacity Helium refrigeration : from state-of-the-art towards FCC reference solutions Francois Millet – March 2015.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
Accelerators for ADS March 2014 CERN Approach for a reliable cryogenic system T. Junquera (ACS) *Work supported by the EU, FP7 MAX contract number.
Cryo AIP Muon Campus AIP Review Arkadiy Klebaner January 23, 2012.
Hydrogen system R&D. R&D programme – general points Hydrogen absorber system incorporates 2 novel aspects Hydrogen storage using a hydride bed Hydrogen.
Workshop Chamonix XIV Shortcuts during installation and commissioning: risk and benefit H. Gruehagen, G. Riddone on behalf of the AT/ACR group 18 January.
Cryogenics in SPS & LHC (2 K / 4.5 K) LHC-CC11, 14 November 2011 L. Tavian, CERN, TE-CRG With the contribution of N. Delruelle, G. Ferlin & B. Vullierme.
Cryogenic update before Fermilab meeting (and after the helium tank review) Coordination meeting 6 th May 2015 K. Brodzinski HiLumi-LHC-CC-Cryo-PPT-18_v1.
January 4, 2007 Project Overview RHIC II Project Internal Cost Review Roberto Than Cryogenics Systems January 4, 2007.
S. Claudet - 31st May 2007Power refrigeration for LHC Power refrigeration at 4.5K & 1.8K for the LHC S. Claudet, CERN AT-ACR.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
ILC Test Facility at New Muon Lab (NML) S. Nagaitsev Fermilab April 16, 2007.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
Cryogenics for crab cavities – SPS/LHC 2 nd HiLumi LHC meeting – Frascati (Italy) 15 November 2012 K. Brodzinski and L. Tavian on behalf of cryogenic team.
The cryogenic system of the HIE-ISOLDE project and its related hazards for persons N. Delruelle on behalf of the TE/CRG group HIE-ISOLDE Safety Review.
SM18 cryogenics infrastructure upgrade L. Serio TE-CRG.
Installation of the T600 at Fermilab CSN2, September 22,
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
TE-CRG Activities D. Delikaris, TE-CRG.
Cryogenic scheme, pipes and valves dimensions U.Wagner CERN TE-CRG.
Crab cavities – cryogenics for SPS and LHC LHC-CC13, 6 th LHC Crab Cavity Workshop – CERN, Geneva, Switzerland 9-11 December 2013 K. Brodzinski on behalf.
PXIE Cryogenics Concept Arkadiy Klebaner Session 5 / WG1 (CW Linac and PXIE) October 26 th, 2011.
LCLS-II Cryoplant Overview
COOLING & VENTILATION PLANTS M. Nonis – CERN EN Department / CV Group Annual Meeting of the FCC study – Rome 14 th April 2016.
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
A. Perin, TE/CRG, Page 2 CERN-GSI FAIR Project integration/coordination meeting 5 14 th October 2015 A. Perin, H. Derking, L. Stewart, M. Chesi,
Crab Cavities SPS cryogenics – progress and requirements Fermilab visit at CERN 02 August 2013 Krzysztof Brodzinski (on behalf of CERN cryogenic team)
Cryogenics and cryolines – Crab Cavities for HiLumi LHC Crab Cavity review November 2015 CERN – Geneva, Switzerland K. Brodzinski, L. Delprat and.
ESS | Helium Distribution | | Torsten Koettig Linac – Helium distribution 1.
H. Hayano(KEK), B. Petersen(DESY), T. Peterson(FNAL),
ILC Cryogenics: Study of Emergency Action and Recovery - in progress -
Cryogenics storage and distribution
2K Cold Box FDR Introduction
Cryomodule test stand at ESS site
He Plant, LN2 Systems and Commissioing
Spoke section of the ESS linac: - Status of prototypes and CDS-SL
SM18 RF M7 Bunker Project Status 14th July 2017
SPS Crab Cavity Test Stand: Safety review summary
HL-LHC IT STRING and Series test of SC link
Schedule CM SPS G.Vandoni.
FRIB Cryogenic Support
IT-4189 Supply and installation of a cryogenic distribution system
CRG - TM Special OdH Introduction
BA6 – crab cavity activities in EYETS
Cryoplant Installation Scope
Dana M. Arenius Jefferson Laboratory Cryogenics Dept Head
on behalf of the RF group
SPS cryogenic proximity equipment and SM18 validation
CRYOGENICS – strategy, unavailability root causes and limitations
Update on HW commissioning
Cryogenics for sc links, a short update
Hollow e- lens, Cryogenic aspects
SPS CC: Final plan for interlocking of crab cavities in SPS
ESS RF Development at Uppsala University
Accelerator Module Test Facility
Status of the cryogenic system for B180
ILC Cryogenic Systems Draft EDR Plan
The HIE—ISOLDE Cryogenic System, its Infrastructure and Considerations for Phase 3 O. Pirotte (TE/CRG)
Cryogenic cavern in Asian site
TEST PLANS for HL LHC IT STRING
ESR 2 Presented to Joint Hall A/C Summer Meeting
HiLumi P1/P5, Cryogenic interfaces for sc links, DFX 2nd review
Summary post TCC#54_02Aug’18
Burst Disc Experiences at CEA Test Stand
Cryogenic upgrade of B165 CRG Status Meeting 16th may 2019
J. Fleiter, S. C. Hopkins, A. Ballarino
Cryogenic upgrade of B163, B165 & B253 Status Meeting 19th December 2018
Presentation transcript:

Crab cavities Cryogenics progress for the SPS Krzysztof Brodzinski, Serge Claudet, Laurent Delprat, Hendrie Derking and Jos Metselaar 6th HiLumi Annual Meeting – Paris – 15 November 2016

Introduction – general layout Outline Introduction – general layout Progress status for main cryo sub-systems CC module cryogenics Safety aspects (Nitrogen-Helium) SM18 cryogenics – status Conclusion and final remarks 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

BA6 general cryogenic layout The SPS cryogenic infrastructure will be composed of Helium circuit and Nitrogen circuit 90m transfer line Cryogenic He transfer line Warm He pipework Cold Box Cryogenic LN2 transfer line VB1 150L LHe LN2 phase separator LN2 storage CCM 100L LHe SB VB2 He Heater He Pump Compressor station BA5 BA1 Legend: VB1 – valve box 1 VB2 – valve box 2 SB – service box CCM – crab cavity module GHe storage 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Helium main systems – status The procurement of cryogenic infrastructure for BA6 was divided in three main subsystems: Production plant (QSC+QUR) – IT4188 status: offers received, preselection done, contract signature in one month (letter of intent in preparation) requested delivery for YETS 2017/18 (tight but realistic) Distribution system (VB1+transfer line+VB2) – IT4189 status: contact signed, visit to contractor on 4.11.2016, design and production underway transfer line delivery expected in Feb.2017, VB1 and VB2 end of 2017 (realistic) Proximity equipment (SB and flex transfer lines – DO-30000, HeP, EH) status: SB+flex lines – offers received, supplier selected, contract to be signed in coming weeks, delivery in summer 2017 (realistic) HeP – to be installed in Mars 2017 EH – to be ordered 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Baseline for controls architecture Definition important as well for cost control and schedule (to allow installation of infrastructure already during EYETS early 2017) 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Global SPS cryo planning – status Cryo for Crab Cav. At SPS Resp: J. Metselaar + O. Pirotte Warm piping foreseen EYETS, LN2 infrastructure for 2017 Infrastructure Resp: L. Delprat + S. Claudet Letter of Intend in preparation, detailed engineering to start Refrigeration Resp: H. Derking + S. Claudet Re-inforced this spring, now being consolidated VB1+VB2 Distribution Transf. line Resp: K. Brodzinski Tendering done, Detailed engineering to start Proximity 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Looking closer underground LSS6 area - zoom Transfer Line Down to VB2: Foreseen for any sc RF On movable table: specific for Crabs VB2 LSS6 area VB2 SB CC module Transfer Line Lift Refrigerator VB1 TA6 area 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Cryogenic circuits and safety protection Flex lines General sc RF test infra Specific CC 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Cryogenic circuits and safety protection Being ordered, to be tested with 1st CC cryomodule at SM18 in 2017 Functional analysis and specific instrumentation under Cryogenics scope of supply 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Looking closer – CC module cryogenics Normal operation supply line Level gauge pipes Cool down circuit EHs Return / Pumping collector Heat load – cool down and 2 K normal operation circuits BNL: static HL of 12.7 W and dynamic HL of 16.8 W -> total= 29.5 W D: static HL: 12.2 W RFD dynamic HL: 15.5 W -> total= 27.7 W Heat Loads from Federico Carra – update Sep.2016 Instrumentation: Summary meeting for cryogenic instrumentation was held on 7th November 2017 (with TE/CI Juan Casas) -> all instrumentation will be ordered and delivered for installation on the components of the cryomodule by May 2017. 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Nitrogen system The nitrogen circuit is necessary to be used as a boost for the cold box capacity and is foreseen to be operated only when necessary. Stand-by of the cavities with liquid will not require using the LN2 circuit. However, the boost will be used during cool down, filling and in situation of high dynamic heat load. Main operation and safety data: LN2 consumption: 25 g/s -> ~110 l/h Dedicated safety orifice will be installed on the supply line limiting the flow to 250 l/h (0.25 m3/h@cold -> 0.25*700= 175 Nm3/h ) Ventilation flow injected via BA6 is ~ 45 000 m3/h TA6 cavern volume is 224 m3 Exercise: Assumptions considered: Closed volume of 224 m3 Instantaneous release of 30 L of LN2 Result: Release and expansion of 30 L of LN2 would decrease the oxygen concentration to 19 %. Concept under study Atm. Safety orifice LN2 LN2 storage tank ~10 t (exact inventory tbd.) surface underground LN2 GN2@80K ~30L phase separator Cold box Components on the surface are to be installed by Autumn 2017, underground components should be delivered to CERN by end of September 2017 and installed in YETS2017/18 (realistic) 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

SPS Ventilation – input for safety analysis The air injection is in SPS via BA 2,4 and 6. LSS6 flow measured by CV is at average 21 600 m3/h. 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

MCI helium case Assumptions for He inventory: ~400 L (55 kg) of LHe underground ~100-120 kg as total inventory MCI for VB1, VB2 or TL -> break of the insulation vacuum MCI for CCM: break of the beam vacuum VB2: 0.5 kg/s (inv. 19 kg @ 4.5 K) VB1: 0.5 kg/s (inv. 19 kg @ 4.5 K) All SV in TA6 will be collected and directed to atm. ~80 m transfer line (scHe: 5 kg) CCM: short term evaporation of 14.5 kg of LHe K.Brodzinski 2016.04.28 VB2 and SB SVs will release He to the tunnel Dedicated safety review for SPS done on 9.11.2016 – no showstopper for the design, related recommendations were given for adaptation. 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

SM18 test and infrastructure Cryogenic goals: Tests in SM18 will allow to check operational behavior of CC cryogenics for cool down, normal operation stability, warm up and helium tightness. Functional test of control system (cryogenic valves) and instrumentation will be checked. The heat load measurement will be done. Preparation status: M7 bunker cryogenic infrastructure requires to install dedicated valve box on the interface between SM18 cryogenic infrastructure and CC service box. Engineering specification of M7 valve box has been completed, related price enquiry process is underway. Delivery is foreseen in April 2017 -> tight schedule. Remark for planning: Late delivery of the valve box could have an impact on SM18 operation schedule since the valve box connection shall be done with double valve isolation from running process. This double valve protection do not exists today. Alternative solutions to connect the valve box after April17 are being studied. 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet

Conclusions and final remarks Big progress on study and design of the cryogenic infrastructure was done in 2016. Procurement of 3 main sub-systems for SPS test is underway, planning is tight but realistic. Controls of entire cryogenic infrastructure studied and being refined, with cables requirements already provided for installation at this EYETS. CC module cryogenics definition is finalized, instrumentation list is completed and validated, order of the instrumentation will be done for delivery in May 2017. BA6 surface cryogenics as well as the nitrogen circuit must be studied, specified and ordered -> additional engineering manpower is needed (will come after restructuration of CRG from 1st December 2016). The safety review for SPS test done -> no showstopper in existing design was identified (some more detailed study must be done/completed -> details in related report). The ODH layout was proposed and will be applied for SPS. Thank you for your attention ! 2016.11.15_TE-CRG_K.Brodzinski_S.Claudet