Unit 02: Voltage sag (6 hrs)

Slides:



Advertisements
Similar presentations
CURRENT TRANSFORMERS AND VOLTAGE TRANSFORMERS
Advertisements

An Electronic System Power Supply Example
ENERGY CONVERSION ONE (Course 25741)
EMC in Electrical Power Systems Frithiof Jensen Power System Engineer November 12, 2013.
Advanced Power Protection Lecture No.2
Chapter 4 Synchronous Generators
On Load Tap Changing Transformer Paralleling Simulation and Control.
Today’s Topics 1- The per unit system 2-Transformer Voltage Regulation
Team 4 Premium Power Service Sponsored by: Detroit Edison Energy Industry Liaison: Allen Andershack Faculty Liaison: Dr. David Stone Members of Team 4:
Combined Selective Systems :-
During a mains supply interruption the entire protected network is dependent on the integrity of the UPS battery as a secondary source of energy. A potential.
Power Electronics Lecture-11 Inverters Dr. Imtiaz Hussain
Chapter 7 SYSTEM PROTECTION
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Overcurrent Protection and Voltage Sag Coordination in Systems with Distributed Generation J. Carlos Gomez 1 M. M. Morcos 2 1 Rio Cuarto National University,
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
Lecture 1 – Power Quality INTRODUCTION TO POWER QUALITY Power Quality phenomenon-Terms and definitions-Various Power events in power quality - causes for.
POWER QUALITY.
EDGE ROUGH DUTY UPS Rough Duty UPS. Power Quality Problems on Rigs Critical Federal Signal loads require clean, regulated, uninterrupted power to operate.Critical.
2. Terms and definitions1 # Voltage Sags and Interruptions.
HydroFly: Flywheel Gavin Abo Nate Stout Nathan Thomas.
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
An Overview on Power Quality Improvement using Multilevel Inverter based Dynamic Voltage Restorer Ms. M. Maheswari 6/21/2014Power Quality Improved using.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
Preventing Voltage Sags and Interruptions. # Equipment supplier awareness: # Customers level protection: # Utility level protection: - Sag magnitude and.
Frankfurt (Germany), 6-9 June 2011 Manuel Avendaño J. V. Milanović Manuel Avendaño – UK – Session 2 – Paper 0529 METHODOLOGY FOR FLEXIBLE, COST-EFFECTIVE.
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
SMJE 2103 Power Quality, Reliability and Availability.
WELCOME.
Power Quality Issues Power Electronics Group.
Power Quality Any power problem manifested in voltage, current or frequency deviation that results in failure or misoperation of customer equipment. IEEE.
DC Machine & Transformer
OPERATING CHARACTERISTICS OF DC GENERATOR
Part Three – Relay Input Sources
Electrical Distribution Analysis & Testing Everything You Need To Know About Power Distribution By Current Solutions PC.
Transformers. Single Phase Transformers Principles of Operation – Single Phase.
CHAPTER 10 SYNCHRONOUS MOTOR Electrical Machines.
Protection and Relay Schemes
DC MOTORS AND GENERATORS
Ch 4: Transmission Line Calculations
Auxiliary power supply (APS) Hossein Harimi 2014
Rectifiers, Inverters & Motor Drives
CHAPTER 6 VOLTAGE REGULATOR Tulus Ikhsan Nasution.
Chapter 2 Diode Applications
Subject Name: LINEAR INTEGRATED CIRCUITS Subject Code: 10EC46
Amplifier: An amplifier is an electronic device that increases voltage, current or power of a signal. According to the class of operation, the amplifiers.
IG BASED WINDFARMS USING STATCOM
BASIC ELECTRICAL TECHNOLOGY DET 211/3
Advanced Fuse-Saving Techniques
SCADA for Remote Industrial Plant
Fault detection Lecture (3).
ELECTRICAL TECHNOLOGY COMPUTER ENGINEERING
Wind turbine technology
Distribution Feeder Voltage Regulation and Control
Introduction To Reactive Power
Series Capacitor Compensation
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Gavin Abo Nate Stout Nathan Thomas
POWER SYSTEM ANALYSIS INTRODUCTION.
Chapter 7 System Protection
Electrical Installation Practice 2
Agenda Introduction of Protective Relays
INTRODUCTION The reason behind overview of supercapacitors energy storage system is that supercapacitors are less weighty than that of battery of the same.
Gavin Abo Nate Stout Nathan Thomas
LOAD BEHAVIOUR DURING VOLTAGE DIPS
Induction Motor Drives
Why AVRs fail to protect Power-sensitive Equipment!
Chapter 29 D.C. Motor. Chapter 29 D.C. Motor D.C. Motor C-29 Motor Principle Comparison of Generator and Motor Action Significance of the Back e.m.f.
Why AVRs fail to protect Power-sensitive Equipment!
Presentation transcript:

Unit 02: Voltage sag (6 hrs) Origin of voltage sags and interruptions, voltage sag characteristics- magnitude, duration, phase angle jump, point on wave initiation and recovery, missing voltage. Area of vulnerability, equipment behaviour under voltage sag, ITIC curve, voltage sag monitoring and mitigation techniques.

voltage sag and Interruptions A voltage sag is a short-duration (typically 0.5 to 30 cycles) reduction in rms voltage caused by faults on the power system and the starting of large loads, such as motors Momentary interruptions (typically no more than 2 to 5 s) cause a complete loss of voltage and are a common result of the actions taken by utilities to clear transient faults on their systems. Sustained interruptions of longer than 1 min are generally due to permanent faults.

Explanation of SAG and Interruption

Sensitivity of Equipments according to location of Fault.

CBEMA and ITI Curves( Information Technology Industry counsel curve) The CBEMA organization has been replaced by ITI,10 and a modified curve has been developed that specifically applies to common 120-V computer equipment (see Fig. 2.16). The concept is similar to the CBEMA curve. Although developed for 120-V computer equipment, the curve has been applied to general power quality evaluation like its predecessor curve. Both curves are used as a reference in this book to define the withstand capability of various loads and devices for protection from power quality variations. For display of large quantities of power quality monitoring data, we frequently add a third axis to the plot to denote the number of events within a certain predefined cell of magnitude and duration. If restricted to just the two-dimensional views shown in Fig. 2.16, the plot tends to turn into a solid mass of points over time, which is not useful.

Voltage sag monitoring and mitigation techniques. Solutions to improve the reliability and performance of a process or facility can be applied at many different levels. The different technologies available should be evaluated based on the specific requirements of the process to determine the optimum solution for improving the overall voltage sag performance

1. Ferroresonant transformers 1.Ferroresonant transformers, also called constant-voltage transformers (CVTs), can handle most voltage sag conditions. 2. Ferroresonant transformers are basically 1:1 transformers which are excited high on their saturation curves, thereby providing an output voltage which is not significantly affected by input voltage variations. 3. CVTs are especially attractive for constant, low-power loads.

Circuit Diagram of CVT

Figure 3.15 shows the voltage sag ride-through improvement of a process controller fed from a 120-VAferroresonant transformer. With the CVT, the process controller can ride through a voltage sag down to 30 percent of nominal, as opposed to 82 percent without one. Notice how the ride-through capability is held constant at a certain level. The reason for this is the small power requirement of the process controller, only 15 VA.

2 Magnetic synthesizers 1. Magnetic synthesizers use a similar operating principle to CVTs except they are three-phase devices and take advantage of the three-phase magnetics to provide improved voltage sag support and regulation for three-phase loads.

They are applicable over a size range from about 15 to 200 kVA and are typically applied for process loads of larger computer systems where voltage sags or steady-state voltage variations are important issues.

3. Active series compensators Advances in power electronic technologies and new topologies for these devices have resulted in new options for providing voltage sag ridethrough support to critical loads.

One of the important new options is a device that can boost the voltage by injecting a voltage in series with the remaining voltage during a voltage sag condition. These are referred to as active series compensation devices. They are available in size ranges from small single-phase devices (1 to 5 kVA) to very large devices that can be applied on the medium-voltage systems (2 MVAand larger).

Standby UPS