Synchronization (Parallel Operation)

Slides:



Advertisements
Similar presentations
ENERGY CONVERSION ONE (Course 25741)
Advertisements

SYNCHRONOUS MACHINES.
Power System Fundamentals
Chapter 4 Synchronous Generators
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
Synchronous Machine The stator is similar in construction that of a induction motor The rotor can be Salient or Non-Salient (cylindrical rotor) Field excitation.
ECE 201 Circuit Theory I1 Instantaneous Power. ECE 201 Circuit Theory I2 Reference for t = 0 Call t = 0 when the current is passing through a positive.
AC Power: average power
Synchronous Generator
Fundamentals of Electric Circuits Chapter 11
Motor ELECTRICAL ENERGY Mechanical Energy.
Module G1 Electric Power Generation and Machine Controls
ENERGY CONVERSION ONE (Course 25741) CHAPTER SIX (& S.G. parallel op. with Pow. Sys. of chapter 5) SYNCHRONOUS MOTORS.
Fundamentals of Electric Circuits Chapter 11
Lecture 32Electro Mechanical System1 Assignment 9 Page 373 Problems 16-13, 16-16, and Due Date: Tuesday 19 th April, 2011 Quiz No.5 Next Week Quiz.
Power System Fundamentals EE 317 Lecture 9 27 October 2010.
Power Factor Improvement Lecture 9. Normally, the power factor of the whole load on a large generating station is in the region of 0·8 to 0·9. However,
Chapter 5. Synchronous Machines.
EET 221 Synchronous Machines Rafiqi.
Chapter 6 Synchronous Motors
BASIC ELECTRICAL TECHNOLOGY DET 211/3
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University 1.
Parallel Operation of Synchronous Generators Based on Sections 5.9 of the Textbook.
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
Synchronous Machines.
Synchronous Motors Introduction An alternator may operate as a motor by connecting its armature winding to a 3-phase supply. It is then called a synchronous.
Synchronous Generator
EEE223 Energy Conversion II Md. Asif Uddin Khan Lecturer, EEE BRAC University.
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
SYNCHRONOUS GENERATOR
Lesson 18 Synchronous Motor Operation and Applications
The flux produced by field winding
Lesson 3: Ac Power in Single Phase Circuits
BASIC ELECTRICAL TECHNOLOGY Chapter 3 - Three Phase System
Electric Circuits (EELE 2312)
Under load-simple calculations
Unified Power Flow Controller (UPFC)
Application.
Control Schemes for Distribution Grids with Mass Distributed Generation AUTHOR: UMAIR SHAHZAD.
Module G1 Electric Power Generation and Machine Controls
Principle of Operation
Induction motor control
Wind turbine technology
Lesson 23: Synchronous Alternator Voltage Regulation
Synchronous Motor Principle and basics.
Parallel Operation of ac generators
Synchronous Motors and Generators
Presentation of ELECTRIC MACHINES Title: Single Phase Motors By: Rahul Khanna{ }EC3 rd Sem Guided By: Prof. Ravi Patel.
SYNCHRONOUS GENERATOR
Synchronising Controls Overview by Robert Breadon
Electromechanical Systems
UNIT II SYNCHRONOUS MOTOR.
Electrical Machines-II
Some practice problems
Synchronous Machines.
ECEN 460 Power System Operation and Control
Unified Power Flow Controller (UPFC)
EE216 Electrical Engineering
SYNCHRONOUS MACHINES - Open circuit & Short circuit tests -
Think beyond.
Chapter 37 Alternators. Chapter 37 Alternators.
Chapter 36 Single – Phase Motors. Chapter 36 Single – Phase Motors.
EET 306 Synchronous Machines
C H A P T E R 13 A.C. Series Circuits.
Electrical Machines (EELE 3351)
Power System Analysis (EELE 4351)
Power Factor Correction
Exercise 6 Power systems.
Presentation transcript:

Synchronization (Parallel Operation)

Parallel operation of synchronous generators There are several major advantages to operate generators in parallel: Several generators can supply a bigger load than one machine by itself. Having many generators increases the reliability of the power system. It allows one or more generators to be removed for shutdown or preventive maintenance.

Synchronization Before connecting a generator in parallel with another generator, it must be synchronized. A generator is said to be synchronized when it meets all the following conditions: The rms line voltages of the two generators must be equal. The two generators must have the same phase sequence. The phase angles of the two a phases must be equal. The oncoming generator frequency is equal to the running system frequency. Load Generator 2 Generator 1 Switch a b c a/ b/ c/

Synchronization Xs1 Ef1 Xs2 Ef2 Xsn Efn Generator G Infinite bus Load Generator Rest of the power system Generator Xs1 Ef1 Xs2 Ef2 Xsn Efn Infinite bus V, f are constant Xs eq = 0 G

Concept of the infinite bus When a synchronous generator is connected to a power system, the power system is often so large that nothing the operator of the generator does will have much of an effect on the power system. An example of this situation is the connection of a single generator to the Canadian power grid. Our Canadian power grid is so large that no reasonable action on the part of one generator can cause an observable change in overall grid frequency. This idea is idealized in the concept of an infinite bus. An infinite bus is a power system so large that its voltage and frequency do not vary regardless of how much real or reactive power is drawn from or supplied to it.

Active and reactive power-angle characteristics Pm Pe, Qe Vt Fig. Synchronous generator connected to an infinite bus. P>0: generator operation P<0: motor operation Positive Q: delivering inductive vars for a generator action or receiving inductive vars for a motor action Negaive Q: delivering capacitive vars for a generator action or receiving capacitive vars for a motor action

Synchronizing And Parallel Operation Of Alternators Necessary conditions for synchronization : The terminal voltage, frequency and phase sequence of the incoming machine should be same as those of the bus bars. Synchronization can be carried out using either i) Dark lamp method ii) Bright lamp method iii) Synchroscope method.

Synchronizing Power and Torque Power developed by an alternator Where θ is the internal angle of the machine and δ is the power angle. Synchronizing power On no load . Synchronizing torque = PSY / ( 2πNs/60).

Two Axis Theory In a salient pole machine, the gap permeance is not uniform. It varies between the maximum at the pole center and minimum at the interpolar axis - respectively called direct axis and quadrature axis. The phasor diagram can be developed using E = V + IaRa + IdXd + IqXq (All the terms being treated as phasors.)

Two Axis Theory Xd , Xq : Direct & Quadrature axis synchronous reactances in . Id, Iq : The current components of Ia in the d & q axis