Commissioning of the Crystal evaluation setup

Slides:



Advertisements
Similar presentations
DREAM Collaboration: Recent Results on Dual Readout Calorimetry. F.Lacava for the DREAM Collaboration Cagliari – Cosenza – Iowa State – Pavia – Pisa –
Advertisements

Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
The Detection of Radioisotopes Using a Thin Scintillating Fiber in a Spiral Adam Jernigan and Eric Blue Advisor: Dr. Thomas Dooling The University of North.
Design and First Results of a Cosmic Ray Telescope For Use In Testing a Focusing DIRC M. P. Belhorn University of Cincinnati The BELLE group at the University.
Tagger Electronics Part 1: tagger focal plane microscope Part 2: tagger fixed array Part 3: trigger and digitization Richard Jones, University of Connecticut.
The Effect of Temperature on the Dark Rate of the Silicon Photomultiplier By Jie Zhao Mentor: Dr. Richard Jones.
P. Karchin – PMTs for Scintillator Based Muon Systempage 11/7/2004 January 7, 2004 American Linear Collider Physics Group 2004 Workshop Stanford Linear.
J. Estrada - Fermilab1 AFEII in the test cryostat at DAB J. Estrada, C. Garcia, B. Hoeneisen, P. Rubinov First VLPC spectrum with the TriP chip Z measurement.
Characterization of Silicon Photodetectors (Avalanche Photodiodes in Geiger Mode) S. Cihangir, G. Mavromanolakis, A. Para. N.Saoulidou.
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
1. 2 Outline Contract Status  Q.A. plan  construction plan Preparations for construction  populating the construction space Microscope electronics.
Measurements on glasses & crystals. An update Diego Cauz University and INFN of Udine Aug 18 th 2009, Fermilab.
Adam Para, Fermilab, April 26, Total Absorption Dual Readout Calorimetry R&D Fermilab, Caltech, University of Iowa, Argonne National Laboratory,
Position Sensitive SiPMs for Ring Imaging Cherenkov Counters C.Woody BNL January 17, 2012.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
VC Feb 2010Slide 1 EMR Construction Status o General Design o Electronics o Cosmics test Jean-Sebastien Graulich, Geneva.
July 29, 2004 American Linear Collider Physics Group Victoria Linear Collider Workshop Muon Detector MAPMT Tests - Calibration R&D Scintillator Based Muon.
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
July 19, 2006VLCW-06 Vancouver1 Scint/MAPMT Muon Prototype Operation Robert Abrams Indiana University.
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Trip-t testing progress report
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
2009 LCWPaul RubinovFermilab 1 Rubinov LCWSA09. Previously, at MT6  We did a quick run in 2008 (parasitic with Minerva) 2 Rubinov LCWSA09.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
GSI 9Feb09 NMI3 – Integrated Infrastructure Initiative for Neutron Scattering and Muon Spectroscopy, Joint Research Activity (JRA8): MUON-S. Contract:
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Calibration of single-photon detectors from spontaneous parametric down-conversion Justin Ripley Columbia University, New York, NY Fermi National Accelerator.
A possible BGO Setup for the 2008 Beam Test Campaign
IFR Detector R&D status
IFR Detector R&D status
Activities at SMI/Vienna in testing the performance of SiPMs
H.E. Fisk, A. Meyhoefer, A. Para, E. Ramberg, P. M. Rubinov Fermilab
A. F. Yanin, I. M. Dzaparova, E. A. Gorbacheva, A. N. Kurenya, V. B
Fast SiPM readout for PET
Prototype activities update
PCAL Cosmic Ray Tests Progress Report C. Smith μ U V W MODULE 2
大強度
Upgrade of LXe gamma-ray detector in MEG experiment
The Life and Times of Cosmic-ray Muons
Vishnu V. Zutshi For the NICADD team.
The New Readout Electronics for the SLAC Focusing DIRC Prototype (SLAC experiment T-492 ) L. L. Ruckman, G. S. Varner Instrumentation Development Laboratory.
X. Zhu1, 3, Z. Deng1, 3, A. Lan2, X. Sun2, Y. Liu1, 3, Y. Shao2
Tagger Microscope Detector & Electronics Status
MPPC for T2K Fine-Grained Detector
MEG II実験 液体キセノン検出器の建設状況
CLAS 12 Status of the test bench Calculation of the time resolution
The MPPC Study for the GLD Calorimeter Readout
Hamamatsu’s SiPM (MPPC) Characteristics and Latest Developments
Presentation transcript:

Commissioning of the Crystal evaluation setup Adam Para, Fermilab, May 19, 2009 Commissioning of the Crystal evaluation setup

The Crystal 5 x 5 x 5 cm BGO crystal (SIC Shanghai) All six sides equipped with filters: ‘UV’ (UG11, low pass filter, 370 nm) ‘Vis’ high pass filter, 400 nm Photodetector mounting fixtures: Phototube centered Hamamatsu MPPC, 9 positions SensL array

The SensL Array of SiPM’s The SensL array was placed under the crystal. It should detect the Cherenkov light produce by the cosmic muon. This detecting system is not fully comissioned yet, and we have no useful information. Stay tuned..

Test Setup Black box with signal/HV feed-throughs two 5 x 5 cm trigger counters read out with the waveshifting fibers (shown) later replaced by scintillators with waveguides Comment on triggering: waveshifter fiber readout reduces the light yield and spreads the photons in time, leading to low amplitude of triggering signals. Coiccidental PMT pulses dominate the trigger rate.

The Setup Trigger counter PMTs Crystal PMT (scint) MPPC (scint) SensL array Crystal PMT (Cher)

Readout/data acquisition Readout with the Paul Rubinov’s 4-channel SiPM ‘data acquisition card’. It is a multichannel high speed digitizer. It provides the detector bias and samples the output signal with 141 MHz rate (at the moment, 250 MHz possible) Two channels modified to remove the bias voltage and used to digitize and acquire the signals from the PMT’s Card used in the ‘external trigger mode’ USB interface to the PC C# data acquisition program written by Paul Scope used to monitor the signals from the trigger counters and to produce the trigger signal for the card

Run 0001 Digitize and record: One of the trigger counters Crystal PMT (scintillation) Crystal MPPC (scintillation) 50 micron pixel, center Crystal MPPC (Cherenkov) 50 micron pixel, center No quantitative analysis, yet, but rather exploratory look at the setup

Examples of waveforms It works ! Scintillation (PMT) well in time with the trigger MPPC dark pulses rate consistent with the specs but they will provide a challenge in the measuring the light output Scintillation process not ‘smooth’, but rather clumpy (time-wise)

Fluctuations in Scintillation (Zoomed)

Some Patologies/ Things to Improve Saturation of the PMT (scintillation)? Need bigger attenuator? Occasional breakdowns. Related to the large size of the input signals?

Run 00001: Summary (Averages) Scintillation decay time consistent with the BGO (PMT) Clear signal of the scintillation observed with the MPPC (1 mm2!) No visible signal in MPPC Cherenkov, yet.. Some evidence for .. ??? Some kind of coupling/cross talk to other channels??

Run 0002 Digitize and record: Crystal PMT (Cherenkov) Crystal PMT (scintillation) Crystal MPPC (scintillation) 50 micron pixel, center Crystal MPPC (Cherenkov) 50 micron pixel, center No quantitative analysis, yet, but rather exploratory look at the setup

Example of Waveform Scintillation clearly visible (both PMT and MPPC) ‘Cherenkov’ PMT signal visible, but probably detecting some short wavelegth component of scintillation (timing!) Cherenkov PMT at 90 degrees to the muon track. How much signal can one expects??

Cherenkov Signals are There! Even at 90 degrees Cherenkov light trapped inside the crystal making it to the detector? or muons traversing the crystal near the PMT and the Cherenkov cone intersecting the face of the crystal? Need to start comparing with the single crystal simulation and need the muon track information

Occasionall Huge Cherenkov Signal

Run 00002 Symmary (averages) Scintillation (PMT and MPPC) signals consistent with Run 00001 Clear evidence for Cherenkov signal (at 90 degrees to the muon track!) What is the signal from the Cherenkov PMT at later times? Long tail of trapped Cherenkov? Short wavelength scintilation?

Next steps More detectors (correlations between them, spatial distribution of the signal) Larger SiPM/MPPC’s (Hamamatsu, IRST) Tracking hodoscope Calibration and quantitative analysis