Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T

Slides:



Advertisements
Similar presentations
1.1 Atomic Absorption Spectrometry (AAS) determination of elements not compounds needs radiation source high temperature for atomization Atomization a.
Advertisements

An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
By: Mae Temporal TOMIC BSORPTION PECTROSCOPY. ATOMS Nucleus- protons (+ve) and neutrons (neutral). Electrons- (-ve) charged particle. Shells- consists.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Atomic spectroscopy  It’s a class of spectroscopic method in which the species examined in the spectrometer are in the form of atoms.
ATOMIC ABSORPTION SPECTROMETER
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Atomic Absorption Spectroscopy Prof Dr Hisham E Abdellatef 2011.
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
1 A TOMIC SPECTROMETRIC METHODS PART 9. 2 Interferences : Four classes of interferences: 1-Spectral interferences 2-Chemical interferences 3- Refractory.
AAS and FES (Ch 9, 7th e, WMDS)
AA and Atomic Fluorescence Spectroscopy Chapter 9
Atomic Spectroscopy Atomic Spectroscopic Methods Covered in Ch 313: Optical Atomic Spectrometry (Ch 8-10) Atomic X-ray Spectrometry (Ch 12) Atomic Mass.
INTRODUCTION TO OPTICAL METHODS
Analytical Chemistry –Atomic absorption Spectroscopy
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Flame photometry.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
announcements and reminders
Atomic Absorption Spectroscopy (AAS)
Spectroscopy Chapter 7.
Instrumental Chemistry
ATOMIC ABSORPTION SPECTROSCOPY
Dr. Maha Daghestani Atomic absorption Lab Techniques.
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Biochemical instrumental analysis-2
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Flame Photometry Flame atomic emission spectrometry
Atomic Absorption Spectrophotometer
Atomic Absorption Spectroscopy
Atomic Absorption Spectrometry
Flame Photometry The principles.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 20
Atomic spectroscopy Elemental composition Atoms have a number of excited energy levels accessible by visible-UV optical methods ä Must have atoms (break.
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
Atomic-absorption spectroscopy
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
A TOMIC - ABSORPTION SPECTROSCOPY. Atomic absorption spectroscopy (AAS) is a technique for determining the concentration of a particular metal element.
Chapter 20 Atomic Spectroscopy.
Atomic-absorption spectroscopy Lab3 Atomic-absorption spectroscopy.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
1 Chapter 8 Atomic Absorption Spectroscopy ( AAS ) Yang Yi College of Science, BUCT.
Flame Spectrophotometry & Atomic Absorption Spectrometry
ATOMIC ABSORPTION SPECTROSCOPY SUPERVISOR: PRESENTED BY: Dr. SANGEETA OBROI SURITI SHARMA M.Sc. Chem.-3 rd Sem. M.Sc. Chem.-3 rd Sem
Chem. 133 – 4/4 Lecture.
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Flame Emission Spectrometry
Chem. 133 – 3/30 Lecture.
Atomic Absorption and Atomic Fluorescence Spectrometry
The ratio of excited state to ground state atoms as a function of temperature is determined by the Maxwell-Boltzmann expression. Fig Excited state.
Spectroscopy Chapter 7.
آزمایشگاه فارماکولوژی و سم شناسی
Elemental composition
Dnyanasadhana College, Thane. Department of Chemistry T. Y. B. Sc
Пламена Спектроскопија
Satish Pradhan Dnyanasadhana College Department Of Chemistry
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
SPECTROPHOTOMETRY Applied Chemistry.
Atomic absorption spectroscopy
Spectroscopy Uses emission and absorption of light by electrons moving between ground and excited state configuration, hence electronic configuration.
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Presentation transcript:

Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T Satish Pradhan Dnyanasadhana College, Thane Department of Chemistry T.Y.B.Sc. Analytical Chemistry Paper-IV Sem-V Atomic Absorption Spectroscopy

Contents 3.1.4 Atomic Absorption Spectroscopy – Principle, Instrumentation (Source, Chopper, Flame and Electrothermal Atomizer) 3.1.5 Quantitative applications of Flame Photometry and Atomic Absorption Spectroscopy – Calibration curve method, Standard addition method and Internal standard method. 3.1.6 Comparison of Flame Photometry and Atomic Absorption Spectroscopy 3.1.7 Applications and Limitations of Flame Photometry and Atomic Absorption Spectroscopy.

Atomic Absorption Spectroscopy UNIT-IV

Introduction In Analytical chemistry Atomic absorption spectroscopy is a technique for determining the concentration of a particular metal element in a sample. Atomic absorption spectroscopy can be used to analyze the concentration of over 62 different metals in a solution.

Atomic Absorption Spectra Excited state E2 Hollow cathode Lamp Ground state E1

Technique The technique typically makes use of a flame to atomize the sample, but other atomizers such as a graphite furnace are also used. Three steps are involved in turning a liquid sample into an atomic gas:

Three steps In AAS Three steps are involved in turning a liquid sample into an atomic gas: Desolvation – the liquid solvent is evaporated and the dry sample remains Vaporization – the solid sample vaporizes to a gas Volatilization – the compounds making up the sample are broken into free atoms

Excited Gaseous Metal atoms M+ X- Sample Solution M+ X- Fine Mist Solid Particles M X Gaseous Molecules M X Gaseous Atoms M(g)+ X(g) Excited Gaseous Metal atoms Large no. of Ground State gaseous atoms absorbs radiation of their own wavelength Principle of F.E.S

Instrumentation The Instrument used in AAS is called as ATOMIC ABSORPTION SPECTROPHOTOMETER The Components are Radiation Source :Hollow Cathode Lamp Rotating Chopper Atomisation Unit Monochromator Detector and Amplifier Read out device

Atomic Absorption Spectrophotometer Rotating Chopper Hollow Cathode Lamp P.M.T.Detector Flame Amplifier Read Out Grating Power Supply Sample Solution

+ + M M Radiation Source Hallow Cathode Lamp Glass Shield Inert Gas Anode + + Quartz Window + _______________________________________ M Cathode ---- M Hallow Cathode Cup

Radiation Source : Radiation Source :Hollow Cathode Lamp HCL is the most common radiation source in atomic absorption spectroscopy. The lamp consist of glass tube. The Lamp is filled with argon or neon gas. The cathode is a cylindrical metal cathode containing the metal for excitation, and an anode. When a high voltage is applied across the anode and cathode, gas particles are ionized. As voltage is increased, gaseous ions acquire enough energy to eject metal atoms from the cathode. Some of these atoms are in excited states and emit light with the frequency characteristic to the metal. Many modern hollow cathode lamps are selective for several metals.

Events in Hollow cathode Lamp: Reactions in the hollow-cathode lamp ionization of filler gas: Ar + e- ® Ar+ + 2 sputtering of cathode atoms: M(s) + Ar+ ® M(g) + Ar excitation of metal atoms: M(g) + Ar+ ® M*(g) + Ar light emission: M*(g) ® M(g) + hV. The cathode contains the element that is analysed. Light emitted by hallow-cathode lamp has the same wavelength as the light absorbed by the analyte element. Different lamp required for each element (some are multielement)

The type of hollow cathode tube depends on the metal being analyzed The type of hollow cathode tube depends on the metal being analyzed. For analyzing the concentration of copper in an ore, a copper cathode tube would be used, and likewise for any other metal being analyzed. The electrons of the atoms in the flame can be promoted to higher orbitals for an instant by absorbing a set quantity of energy (a quantum).

2.Rotating Chopper: Resonance radiation given by hollow cathode lamp as well as sample atoms in flame due to thermal excitation are detected by detector which creates an interference in absorbance measurement. To eliminate the radiation coming from atom in flame by excitation of atoms. Rotating chopper is used. Rotating chopper is arrange in between flame and Hollow cathode lamp. It is circular disc divided into four quarters, out of which two are mirrored and two are opened. When disc rotates at high speed when the mirror quartered in front of the lamp it reflects the radiation. The second moment it opens in front of lamp and radiation passes to sample being absorbed by it and reaches the detector in pulses.

2.Rotating Chopper: Steady light from hollow cathode lamp is broken into an irregular beam or pulsating light. This gives alternating/pulsating current in the PMT detector. This alternating/pulsating current is amplified by amplifier. The radiation emitted by atoms in flame produces a steady current which is not amplified.

Atomization Unit Disadvantages of Flame atomizer: 1) Total consumption Burner 2) Laminar flow burner Electro thermal Atomizer Disadvantages of Flame atomizer: A large portion of sample flows down the drain The residence time atoms in optical path is very short less than 10 -4 seconds.

ELECTRO THERMAL ATOMIZER (Graphite furnace).   PMT DETECTOR

 ELECTRO THERMAL ATOMIZER (Graphite furnace). Electro Thermal Atomizer also called as Graphite furnace. Consist of hollow graphite tube 5cm long and 1 cm internal diameter. The tube is opened at both ends and has central hole to introduce of sample by micropipette. This tube is arranged in such a way that radiation from the source passes along the axis of the tube. Two electrodes are fitted at the end of the tube. The inert gas like neon or argon is allowed to flow over the tubes to avoid the oxidation of graphite. The tube is surrounded By water cooled metal jacket. The solution of the sample to be analysed (1-100ul) is introduced by inserting the micro pipette through the port in the outer jacket and gas inlet in the centre of graphite tube. The graphite cylinder is then heated by the passage of electric current to a temperature that is enough to evaporate the solvent from the solutions. The current is then increased.

STAGES IN ELECTRO THERMAL ATOMIZER Drying stage Ashing stage Atomization stage Temperature Range Temperature of the furnace is maintained above the boiling point of the solvent. For aq. Solution furnace temperature is adjusted to 383K for 30 Sec Temperature of the furnace is maintained at 600K -1500K for period of 45 sec. Temperature of the furnace is maintained at 2300K -3300K for period of 5 sec. Function Solvent undergoes evaporation Organic substance are volatilized and other chemical matrix of the sample is destroyed Gaseous atoms of metal are formed

Advantages: Temperature that is enough to ash the sample and to produce the metal atoms. The sample volume is small No need for fuel -oxidant mixture. High sensitivity No flame noise. Solid sample can be used directly. Heat distribution is uniform and temperature is steady.

4) Monochromator: Prism or grating monochromator are used in AAS. The function of the monochromator is to select a given absorbing line from spectral lines by emitting hallow cathode lamp.

Atomic Absorption Spectrophotometer Rotating Chopper Hollow Cathode Lamp P.M.T.Detector Flame Amplifier Read Out Grating Power Supply Sample Solution

Applications of Atomic Absorption Spectroscopy Water analysis (e.g. Ca, Mg, Fe, Si, Al, Ba content) Food analysis Analysis of animal Feedstuffs (e.g. Mn, Fe, Cu, Cr, Se, Zn) Analysis of additives in lubricating oils and greases (Ba, Ca, Na, Li, Zn, Mg) Analysis of additives in lubricating oils and greases (Ba , Ca, Na, Li, Zn, Mg) Analysis of soils Clinical analysis (blood samples: whole blood, plasma, serum; Ca, Mg, Li, Na, K, Fe)

Advantages over flame atomic absorption spectroscopy: Solutions, slurries and solid samples can be analysed. Much More Efficient Atomization Greater sensitivity Smaller quantities of sample (typically 5 – 50 uL) provides a reducing environment for easily oxidized elements Disadvantages Expensive Low precision Low sample throughput Requires high level of operator skill

Distinguish between FES and AAS Solutions, can be analysed. Much More Efficient Atomization Lesser sensitivity Larger quantities of sample. Alkali metal and alkaline earth metals can be determined AAS Solutions, slurries and solid samples can be analysed. Much More Efficient Atomization Greater sensitivity Smaller quantities of sample (typically 5 – 50 uL) Alkali metal and transition metals can be determined(64 elements)

Distinguish between FES and AAS Different hollow cathode lamps are required as source of radiation Chopper is used to eliminate radiation emitted from flame. The quality of monochromator should no be of very high degree . AC. Amplifier is used to amplify only AC Current.  The absorption intensity depends upon unexcited atoms.  signal is obtained due difference of energies between excited and ground state atom. High degree operator is not required FES Flame serves as source for different element. Chopper is not used . The quality of monochromator should be of very high degree Amplifier is used to increase the output signal of detector. The emission intensity depends upon excited atoms. Signal is obtained from wavelength emitted by atoms. High degree operator is required

Distinguish between FES and AAS The technique is expensive (cost 15- 25 Lakh).  Solutions, slurries and solid samples can be analysed. Much More Efficient Atomization. Greater sensitivity. Smaller quantities of sample (typically 5 – 50 uL) Alkali metal and transition metals can be determined(64 elements) FES The technique is not so expensive (cost 60-70 thousands only) Only Solutions, can be analysed. Less Efficient Atomization Lesser sensitivity Larger quantities of sample. Alkali metal and alkaline earth metals can be determined.

Applications of Atomic Absorption Spectroscopy Water analysis (e.g. Ca, Mg, Fe, Si, Al, Ba content) Food analysis Analysis of animal Feedstuffs (e.g. Mn, Fe, Cu, Cr, Se, Zn) Analysis of additives in lubricating oils and greases (Ba, Ca, Na, Li, Zn, Mg) Analysis of additives in lubricating oils and greases (Ba , Ca, Na, Li, Zn, Mg) Analysis of soils Clinical analysis (blood samples: whole blood, plasma, serum; Ca, Mg, Li, Na, K, Fe)

Quantitative Analysis Calibration Curve method Standard addition method Internal Standard addition method

Calibration Curve method

Standard addition method In this method the absorbance of unknown (X) is first found out by aspirating into flame against blank.Then a series of standards having definite amount of unknown (X) plus varying amount of standard are prepared and diluted to same volume in each case .Their absorbance are then obtained . A graph of absorbance (A) against concentrations of standard (S) gives a linear curve. The concentration of the unknown can be determined by extrapolation of line which cuts to X axis.

. . . . . Standard addition method Absorbance--- X X+S X+2S X+3S X+4S . . . . . Absorbance--- X X+S X+2S X+3S X+4S Concentration----- Concentration of Unknown.

Internal Standard addition method Ax ----- At Concentration-----