Reheat Coil (Typical of 5)

Slides:



Advertisements
Similar presentations
Circulating Water System
Advertisements

HEAT PUMPS.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Basic Refrigeration Cycle
Components of HVAC System
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Control Valves: Specifications, Sizing & Technologies
Booster System Basics: Constant Speed Systems
Pumps and Pumping Stations
Upon completion of this training one should be able to: Identify different types of hydronic heating systems Identify key components in a simple hydronic.
Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke M.E. Undergrad 1.
AC Power TCZ Pump VVVF Drive TT 2 W/H CWS 4-way valves TT 3 TT 4 TT 1 S2 S1 FT 1 CWR FT 2 CW CWS = Cold Water Supply CWR = Cold Water Return CW = Cold.
Centrifugal Pump Basics Terms commonly used in the pumping industry.
COMMERCIAL REFRIGERATION
Product Introduction.
Heather Instasi Tulio Borel. Objectives Design a radiant heating system for a greenhouse located in Atascadero, CA Hot ethylene-glycol solution flowing.
Piping Systems.
STEAM HEATING.
Hydronic Mechanical Controls
2006 Oct. 19 DES Project -- Vaidas Simaitis, University of Illinois1 DHE – Detector Head Electronics Monsoon 80mm Crate Heat Load.
Hydraulics For The Long Term
1 Multi-use Facility. 2 Occupancy – 140 persons Building Characteristics Single story 20,000 square feet (250’ x 80’) Standard construction.
Water piping design.
DESIGN AND CONSTRUCTION OF AN INDUCTION FURNACE (COOLING SYSTEM) Presented by MG THANT ZIN WIN Roll No: Ph.D-M-7 Supervisors : Dr Mi Sanda Mon Daw Khin.
HVAC523 Circulator Pumps.
FEASIBILITY OF COMPONENTS CLARA ECHAVARRIA & JONATHON LOCKE.
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
80 gal Elec. DHW 120+F ch H C r Pressure Temperature Relief Valve r Legend Exists Today.
Lecture Objectives: Finish with thermal storage systems Learn about plumbing systems.
© Alfa Laval Pure Cooler R134a r-evolution New high efficiency R134a dedicate evaporator. Pure Cooler Passes (tube side)1 Tube arrangementStraight.
Prepared by : Abd Aljabbar Rabaya Ammar Salloum Sameh Shawahni Supervisor : Dr. Eyad Assaf 1.
MECHANICAL ENGINEERING FOR SYSTEM BALANCE ASHRAE MEETING 2/15/2007 NORTHERN NEVADA CHAPTER 126 MATT BRENNAN, TBE.
Section 3 Using Heat.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Available Water Flow Meter Size Typical flow depending on size
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
1 Hospital Building and Campus Piping. 2 Hospital Building Occupancy – office and patient areas Patient areas: 24 hours per day Office areas: 8 am – 5.
BOILER MOUNTINGS & ACCESSORIES
Lecture Objectives: Learn about Pumps and System Curves.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Building 180 NORMATEF TEST FACILITY Demineralized cooling water station upgrade R. Bozzi / EN-CV.
CENTRIFUGAL PUMPS:- DESIGN & PERFORMANCE Ir. N. Jayaseelan 2012.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
James McIntyre VRF Training Manager V5 Key Components.
EMERGING TECHNOLOGIES AVAILABLE TO REDUCE COMPRESSED AIR DEMAND Double Acting Air Cylinder Double Acting Air Cylinder Air Operated Diaphragm Pumps Air.
Domestic Hot Water Recirculation Design
Design, Evaluation and Application of a Fuel Cell Vehicle
Components Pumps.
DESIGN AND DEVELOPEMENT OF AIR CONDITIONING CUM WATER COOLER

Induction System – carburetor circuit
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
System Diagrams Symbol Library – Black Background David Sellers
Date of download: 10/23/2017 Copyright © ASME. All rights reserved.
High-rise Hotel Lobby Air Handling System
______________ Combustion Engine
High Performance HVAC Installation
By: JAGDEEP SANGWAN Refrigeration Basics 101.
FBE03: Building Construction & Science
Lecture Objectives: Learn about Pumps and System Curves.
Reheat Coil (Typical of 5)
AIR COMPRESOR Chapter-13.
System Curve Example Design Condition 20 ft.w.c. required each way to deliver design flow to and from the headers at the loads Distribution Pump Bell.
Presented by Mike Zacharias
Presentation transcript:

Reheat Coil (Typical of 5) Butterfly valve Logic Diagram Exercise Heating Hot Water System Page 1 2016-11-24 Drawn By – DAS Click Here to Return to the Exercise Description Two way control valve Balance valve Check valve Ball valve Pressure reducing valve Pressure relief valve Three way control valve Steam trap Thermometer with well Pressure gauge with isolation valve PT Pressure Transmitter TT Temperature transmitter with well DP Differential pressure transmitter with isolation valves Match Line – See Sheet 2 A B Pump 2 Normally Open Heat Exchanger Bell and Gossett SU-67-2 Shell Side Flow - 85.5 gpm Entering water – 147°F Leaving water – 170°F Pressure drop – 2.11 ft.w.c. Tube Side 1,019 lb/hr 5 psig steam TT Warm-up Coil Normally Open to the Coil Capacity – 586,200 Btu/hr 6 ft. high x 8 ft. wide Air Side Flow rate = 22,306 cfm Entering air temperature – 62.0°F Leaving air temperature – 86.3°F Pressure drop – 0.09 in.w.c. Water Side Flow rate = 29.8 gpm Entering water temperature – 170.0°F Leaving water temperature – 130.0°F Pressure drop – 4.4 ft.w.c. 1st Floor Reheat Loads; Nominal gpm for the floor = 36.5 gpm TT Heat Exchanger 1 LPS LPR 1st Floor Finned Tube Radiation Bell and Gossett 2AD-es Flow - 87.4 Head - 45.6 Speed - 1,750 Bhp - 1.3 Efficiency - 75.9% Motor hp - 2 Normally Open Normally Open to the Coil Capacity – Varies Air Side Flow rate = Varies, 500 fpm maximum face velocity Entering air temperature – 53.0°F Leaving air temperature – 82 °F Pressure drop – 0.1 in.w.c. maximum Water Side Flow rate = Varies Entering water temperature – 170.0°F Leaving water temperature – 150.0°F Pressure drop – 5 ft.w.c. maximum. See also Note 1 on sheet 2 Typical of 4 circuits Vulcan LV4-S, VC433, 1" line size, 4-1/4" x 3-5/8" fins, 32 fins per foot, 0.20 thick fins, 14" enclosure, single tier, 18" mounting height, 816 Btu/hr/ft; 243 feet of active element in four circuits of 7.2 gpm each, 28.8 total gpm, 14°F ∆t, 170°F supply, 156°F return Reheat Coil (Typical of 5) TT DP Pump 1 Bell and Gossett 2AD-es 87.4 gpm at 45.6 ft.w.c. 75.9% Efficiency 1,750 rpm, 1.3 Bhp, 2 hp motor (Typical for each pump) DP TT TT PT Cold water make-up from a back flow preventer Diaphragm type expansion tank

Reheat Coil (Typical of 7) Logic Diagram Exercise Heating Hot Water System Page 2 2016-11-24 Drawn By – DAS Click Here to Return to the Exercise De scription Match Line – See Sheet 1 A B TT Normally Open Typical of 4 circuits Vulcan LV4-S, VC44, 1" line size, 4-1/4" x 4-1/4" fins, 40 fins per foot, 0.20 thick fins, 14" enclosure, single tier, 18" mounting height,996 Btu/hr/ft; 270 feet of active element in four circuits of 7.2 gpm each, 28.8 total gpm, 19°F ∆t, 170°F supply, 151°F return 2nd Floor Finned Tube Radiation TT Reheat Coil (Typical of 7) Normally Open to the Coil Capacity – Varies Air Side Flow rate = Varies, 500 fpm maximum face velocity Entering air temperature – 53.0°F Leaving air temperature – 82.7 °F Pressure drop – 0.1 in.w.c. maximum Water Side Flow rate = Varies Entering water temperature – 170.0°F Leaving water temperature – 150.0°F Pressure drop – 5 ft.w.c. maximum See also Note 1 2nd Floor Reheat Loads; Nominal gpm for the floor = 36.5 gpm Note 1 Summer time coil performance (reheat only vs. heating) Capacity – Varies Air Side Flow rate = Varies, 500 fpm maximum face velocity Entering air temperature – 53.0°F Leaving air temperature – 62.1°F Pressure drop – 0.1 in.w.c. maximum Water Side Flow rate = Varies Entering water temperature – 90.0°F Leaving water temperature – 85.8°F Pressure drop – 5 ft.w.c. maximum Bell and Gossett 2AD-es Flow - 87.4 Head - 45.6 Speed - 1,750 Bhp - 1.3 Efficiency - 75.9% Motor hp - 2