Welcome
NIA-MTDC Power Supply System By Dhritiman Nath, ET Trainer L.Nilling & G.Patgiri
NIA-MTDC power supply Arrangement and it’s proposed modification Contents Introduction Power supply schemes NIA-MTDC power supply Arrangement and it’s proposed modification
Introduction Power is transmitted and distributed by the distribution network. The system has both H.T. and L.T. networks for distribution of power. 33 KV 11 KV H.T. voltage 3.3 KV 415 V L.T. voltage
Continued…. Power is supplied to various OCS,GCS installations. Within OIL township , it distribute the power to places like RCE office , Bihutoli , R&D ,Oil market , Zaloni club etc. Power is also supplied for area lighting , street lighting with in OIL township. It has a total of 103 no of sub stations.
Continued…. The network uses both overhead lines as well as underground cables for power distribution. Currently , approximately 70 KMs of overhead lines are being used for power distribution. The network is supplying power to areas within a radius of 20 KMs from Duliajan.
Power supply schemes To provide power to various installations which are not within a close range, we are using a 33 KV ring. This ring includes sub-stations like – OCS 2 OCS 3 PONTOON WELL 80 Loads drawn from this ring – OCS – 8 GCS -8 GCS-6 OCS-6 OCS-1 etc.
33 KV RING 11/33 KV SWITCHYARD W-208 GCS8 OCS8 SS-C OCS 3 OCS 2 SS-A OWS SS D MP7 NWS GCS-6 WELL 80 PONTOON W-240 W-254 NEW PONTOON OCS -6 OCS-1 GCS 1B C GROUND South bank
3.3 KV ring constitute the DOMESTIC RING MAIN This ring includes the following sub-stations – SS-1 SS-2 SS-3 SS-4 Various loads drawn from this ring are – VIP’s Bungalow Zaloni club Duliajan club Zaloni guest house Medical Bihutoli Qtrs etc
3.3 KV RING POWER HOUSE W-53 GCS-5 BIHUTOLI SS-1 SS-5 MEDICAL SS-4 GUEST HOUSE SS-2 SS-3
Power is also supplied with 11 KV ring. This ring includes various sub-stations like – SS ‘D’ DPS SS GCS -4 OCS -4/SS-E We also have some radial 11 KV feeders – Tingri feeder LPG SS-6 Various loads are – MTDC NIA RCE office Qtrs/B’lows/schools/Oil Market/SBI/Industrial Area
11KV RING MTDC SS-7 SS-E NIA W203 SS-6 GCS4 NIAN G NIAC LPG PH 11/33 KV Switch yard W21 DPS D W57 DNPL W50 DD SS TINGRI SS B BBARI GCS5 TDX DX
NIA- MTDC power supply system and it’s proposed modification MTDC sub-station is fed from one feeder only. Fault occurrence is high in this feeder. Alternate supply source is required to maintain power reliablity in MTDC area.
Schematic diagram of NIA-MTDC 4 WAY RMU To SS E DDPS-E feeder NIAC NIAN NIA 3 WAY RMU MTDC feeder DPS 3 WAY RMU MTDC
Recall Introduction to transmission and distribution section Power supply schemes NIA-MTDC power supply system and it’s proposed modification
Thank you