Airflow Quantity and Velocity

Slides:



Advertisements
Similar presentations
Ventilation submitted by Christopher J. Bise
Advertisements

Unit Conversions. Unit Conversion Necessary in science and engineering to work across different systems of measurement or to express quantities in different.
Nonmetallic ducts (Additional information) –Fiberglass (also see section 18.5) Made of glass wool insulating material in which the stranded fiber wool.
Airflow Properties & Measurement
CUSTOMARY MEASUREMENT UNITS
inches = 1 foot 3 feet = 1 yard 36 inches = 1 yard 5280 feet = 1 mile 1760 yards = 1 mile.
2.6 Ratios, Rates, and Conversions
Industrial Skills Area: Descriptions, Calculations & Industrial Applications.
Calculating board Feet linear feet square feet
Exponents By Monica Yuskaitis. Location of Exponent An An exponent is a little number high and to the right of a regular or base number. 3 4 Base Exponent.
Ventilation 1 - Program Basic Math & Problem Solving
NAFA Guide to Air Filtration. Chapter 13 Owning and Operating Cost By Dirk ter Horst April 19 th, 2012 Another Approach…. Air Filter Comparison.
Unit Conversions Unit Conversion
EXAM 1 Study Aids or… Think, Multiply, Divide, Conquer.
Industrial Skills Area: Descriptions, Calculations & Industrial Applications.
Review covering scientific notation, calculating slope, metric conversions, dimensional analysis (unit cancellation), basic algebra, and trig functions!
Formulas for Perimeter and Area
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Intro to Physics. Scientific notation is a system that makes it easy to work with the huge range of numbers needed to describe the physical world. Even.
Clean air solutions Health Care Segment Update Dave Blackwell.
To many people, accuracy and precision mean the same thing: to someone involved in measurement, the two terms should have very different meanings. Accuracy.
Dimensional Analysis or Unit Analysis
November Top Ten Approaches to Lowering Fan Energy in Cleanrooms.
2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt 5 pt 1pt Area Signed Number Operations Unit.
Substitution 1. Calculate a + b – c If a = 10 b = 8 and c = 12 When g = 6 and h = 14 2t 2 – 4t 2 t = 4 and t =6 ½ w + ¼ h w = 12 and h = 20.
Multiple Unit Multipliers Conversion of Units of Area
To many people, accuracy and precision mean the same thing: to someone involved in measurement, the two terms should have very different meanings. Accuracy.
NAFA Guide To Air Filtration Chapter 2 Principles of Air Flow, Air Pressure And Air Filtration presented by the National Air Filtration Association Fourth.
Testing Fan Filter Units
Volume of Cones & Spheres
Scientific Notation 1. Scientific notation is a way to shorten a large number (makes using it in calculations easier) 2.
Dimensional Analysis  What happens when you divide a number by itself?  What happens when you divide a unit by itself?  In both cases, you get the.
Location of Exponent An An exponent is the small number high and to the right of a regular or base number. 3 4 Base Exponent.
Unit Conversions. A physical quantity must include: Number + Unit.
Math Review Basics Using Multiplication and Division.
Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.
14.0 Math Review 14.2 Inches to Feet & Areas. Division 80 ÷ 5 = 16 Also written as:
15.0 Math Review 14.5 Using Basic Formulas. Converting Units Converting 6 inches of Mercury into Inches of Water Inches of Mercury are multiplied by 13.6.
Unit Conversions. Unit Conversion Necessary in science and engineering to work across different systems of measurement or to express quantities in different.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Converting Units Within the US Customary System (inches and feet) NCSC Sample Instructional Unit - Elementary Meaurement Unit Lesson 2 1.
Length Unit Conversion (Easy Method)
Example: Multiply the following rational expression.
NAFA Guide To Air Filtration
Exponents.
Maria’s Restaurant Chapter 4 Section 15
Impingement and Extended Surface Filters
Scale Drawing/Scale Models
26 Math Review Part 2 Inches to Feet & Areas
Ratios, Rates & Conversions
Media Velocity Panel vs Extended Surface
Hollinee Filtration.
Sustainability and Life Cycle Costing of Air Filtration
GVSU Case Study Analysis of HVAC filter using MERV 13 filter with low pressure drop design. 1.
ANSI/ASHRAE 52.2 A destructive test to measure minimum efficiency reporting value (MERV) Efficiency test aerosol is Potassium Chloride (KCl) particles,
Exponents By Monica Yuskaitis.
In-Situ Filter Testing
Exponents.
Measurement GTT – Unit 7 – Green Architecture © 2012 Project Lead The Way, Inc.Green Architecture.
Exponents By Monica Yuskaitis.
2.6 – NOTES Dimensional Analysis
General strategy for converting units:
Standard Measurement When measuring, it is sometimes necessary to change from one unit into another. Unit refers to what you are measuring. FOR EXAMPLE…
Exponents.
Length in the Customary System.
Problem: How many feet are there in 78 inches? Solution:
Substitution 1. Calculate a + b – c If a = 10 b = 8 and c = 12
Mathematics of Air Filtration
Multiplying and Dividing Rational Expressions
Significant Figures and Conversions
Presentation transcript:

Airflow Quantity and Velocity Q=VA Quantity of Air “Q” (expressed as CFM) Velocity of Air “V” (expressed as FPM) Face Area “A” (expressed as Sq. Ft.) With 2 known values – 3rd can be calculated

Calculating Quantity (CFM) When face area and velocity are known the CFM can be determined. Q=VA 4 x 500 = 2000 4 sq. ft. x 500 FPM = 2000 CFM

Calculating Velocity (FPM) When face area and air quantity are known the velocity can be determined. V=Q/A 2000 / 4 = 500 2000 CFM / 4 sq. ft. = 500 FPM

Calculating Face Area (sq. ft.) When the velocity and quantity of air are known, the face area can be determined. A=Q/V 2000 / 500 = 4 2000 CFM / 500 FPM = 4 sq. ft.

Application Example 40,000 CFM / 400 fpm = 100 sq. ft. An engineer wants to know how many filters he needs to use for a system that delivers 40,000 CFM - desired velocity is 400 fpm. Calculations 40,000 CFM / 400 fpm = 100 sq. ft. Assume a 24x24 face size with 4 sq. ft. 100 sq. ft / 4 sq. ft. = 25 filters

Another Method Knowing he wants 400 fpm you would take the face area of a 24x24 which is 4 and multiply x 400 which equals 1600 CFM/filter 40,000 total system CFM divided by 1,600 CFM per filter also equals 25 filters.

Square Inches to Square Feet When dealing with a 24x24 it is easy to come up with the face area (2x2=4) Other sizes require conversion Divide square inches by 144 (sq in/sq ft) 20x20 = 400 / 144 = 2.777 round to 2.78 20x25 = 500 / 144 = 3.472 round to 3.47

Application Example An engineer doesn’t have CFM data for his system and wants to know what it is. He has measured the velocity at 375 fpm and the unit contains 24 - 20x20 filters. Calculations Convert sq. in. to sq. ft. 20x20 = 400 / 144 which equals 2.777 round to 2.78 sq. ft. 24 x 2.78 = 66.72 total sq. ft. 66.72 sq. ft. x 375 fpm = 25,020 CFM

Application Example A maintenance lead is having air delivery problems and wants to lower the pressure drop across his filter bank. He has room to expand the filter bank. The bank contains 10 filters that were originally MERV 7 pleats but have been upgraded to MERV 13. System CFM is 24,000 and he wants to reduce his velocity to 300 fpm to cause a big reduction in pressure drop. How many filters does he need?

Calculation Examples Alternate Method He is asking for 300 fpm velocity 4 x 300 = 1200 CFM per 24x24 filter Total system CFM 24,000/1,200 = 20 filters Alternate Method 24,000 / 300 = 80 sq. ft. face area needed 80 / 4 = 20 filters needed.

Media Velocity Media velocity is calculated by starting with the CFM per filter and dividing by the total media area. It is an important consideration because lower media velocities normally improve the efficiency of a filter. Excessive media velocities can adversely affect media performance! Pleat – 2,000 CFM / 17.6 sq. ft. = 113.6 FPM 113.6 is the media velocity for this pleat Bag or pocket filter – 2,000 CFM / 90 sq. ft. equals 22.22 FPM media velocity

Additional Examples Box – 2,000 CFM / 58 sq. ft. = 34.48 FPM Cell – 2,000 CFM / 100 sq. ft. = 20 FPM 4V – 2,000 CFM / 194 sq. ft. = 10.31 FPM Hepa – 1,000 CFM / 160 sq. ft. = 6.25 FPM