New EM210_AV.

Slides:



Advertisements
Similar presentations

Advertisements

Arctic IEC-104 Gateway Jari Lahti, CTO.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
LP33 Series UPS kVA 400Vac/CE
SYMAP-BC SYMAP-BC.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
© ABB ABB DELTAsingle Commercial and technical presentation.
© ABB ABB ODINsingle Commercial and technical presentation.
G GE Power Management MMII Intelligent MCC Controller.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
PYROCON12 De-Ice controller User Operation Presentation 2013.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Make the most of your energy December 2008 PowerLogic Enercept Submetering ….when space is at a premium PowerLogic® Enercept Meter.
Arctic Control Introduction V 1.0. Arctic Control The Arctic Control is a device with integrated wireless communications for controlling medium-voltage.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Make the most of your energy Make the most of your energy SM Add application photo in this area Need an easy to use, modular system for revenue metering?
1 Chang Shuan Eletronics Co., Ltd
New IQ300 IQ Data & IQ Generator Replacement. Current Product  IQ Data Measures  Phase Currents  Voltage L-L, L-N  IQ Generator adds  Frequency measurement.
Page 1 March 2007 CheckSource 2.3 Portable Power Phantom Load.
1 SPECIFICATION Power : DC 24V ± 5% Input Signal : RS – 485 SERIAL Display: 4 DIGIT LED (H:10.16mm) Address Selection : POWER TO INPUT Isolation: POWER.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
1 Chang Shuan Electronics Co., Ltd
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
Serial/Fiber-Converter - IE-MCT-1RS232/485-1SC/ST
PMC-592 HMI's Front Panel Operation
DIGITAL MULTIMETER DMG
POWER FACTOR CORRECTION
AUTOMATIC POWER FACTOR CONTROLLERS
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
User Operation Presentation
VARLOGIC NRC12 Varmetric Controller
POWER FACTOR CORRECTION
Training on Power Monitoring and Management Solution
ENERGY METERS DME SERIES
System Network Structure
HD POWER TRANSDUCER SERIES
ABB i-bus® KNX Valve Drive Actuator VAA/A
PTS 3.3 C Portable Test System.
TPS - Thyristor Power Supply for Resistive/Inductive Loads
HD SIGNAL CONDITIONER SERIES
1 Input-Output Organization Computer Organization Computer Architectures Lab Peripheral Devices Input-Output Interface Asynchronous Data Transfer Modes.
FEEDER PROTECTION UNIT
IDM-3 3-PHASE AMMETER.
ICP DAS Power Monitor and Management Solution 2016,03,28
PowerValue 11/31 T Sales Presentation
De-Ice control devices
Moving your Control Forward - VFD from Unitronics
METER SPECIFICATIONS.
Lesson 11: Transformer Name Plate Data and Connections
Customer Presentation
Technician Operation Presentation
Moving your Control Forward - VFD from Unitronics
PowerLogic™ offer for the basic metering market
Introduction to the POWERLOGIC® PM700 Series Power Meters
PowerLogic PM5350 High-performance multifunction power meter
PLC Front Panel.
PM9, PM9P and PM9C Power Meter
Meet demanding customer expectations with the right energy meter
PowerLogic ION6200 Power and energy meter.
Simple, accurate tenant sub-metering
Presentation transcript:

New EM210_AV

EM210 – Housing EM21=EM210 No difference!

(supply between L1 and N) (supply between L2 and L3) EM210_AV – New features Measurement on three-phase systems without neutral (always self-power supply) EM21_AV EM210_AV Mandatory connection! (supply between L1 and N) Aggiunte features Neutral not required (supply between L2 and L3)

EM21_AV EM210_AV 9.6 kbps 9.6 - 19.2 - 38.4 - 57.6 - 115.2 kbps EM210_AV – New features High serial communication speed Selectable parity mode and selectable stop bit EM21_AV 9.6 kbps No parity 1 stop bit EM210_AV 9.6 - 19.2 - 38.4 - 57.6 - 115.2 kbps None or even parity 1 or 2 stop bit Aggiunte features

EM210_AV – New features New protocol compatible with all other coming CG meters Aggiunte features

EM210_AV – New features Exported (negative) kWh meter in new E application; new F application too EM21_AV Aggiunte features

EM210_AV – New features Voltages and currents THD measurements, current neutral (calculated), working hours Aggiunte features

EM210_AV – New features Wrong connection function (available over communication port) (1/2) Enabling, disabling Detection of wrong voltage phase sequence Detection of wrong secondary current connection Detection of wrong association between phase voltage and phase current Aggiunte features

EM210_AV – New features The algorithm works with loads whose PF Wrong connection function (available over communication port) (2/2) The algorithm works with loads whose PF is between 0.77L and 0.99C Aggiunte features

EM210_AV – New features TON selectable: 30 ms or 100 ms Selectable pulse duration TON selectable: 30 ms or 100 ms (according to EN62052-31) Opto-mosfet output (linked to +kWh) Aggiunte features TOFF ≥ 120 ms (according to EN62052-31)

EM210_AV – New features EM21_AV I1 I2 I3 (N L) EM210_AV EM210_AV New terminals position for better error-proof connection EM21_AV I1 I2 I3 (N L) In Out In Out In Out N L1 L2 L3 EM210_AV Aggiunte features EM210_AV

EM210_AV – Main features External current transformer connection (5A) Full set of variables available to perform a complete load analysis Energy measurement kWh (total imported active energy, total exported active energy) and total reactive energy for an accurate cost allocation Easy connections management One digital outputs and RS485 communication port for quick and easy data transmission to PC/PLC for full load control or integration to BMS Detachable display Multi-use housing: for both DIN-rail and panel mounting applications Power supply: self power supply from 40V to 480VAC (connection VL2-L3)

EM210_AV – Main features Key Specifications Housing (H x W x D): 72x72x64.6 mm Display type: LCD, 2 lines: 1st line:7-DGT, 2nd line:3-DGT + 3-DGT Instantaneous variables: 3 x 3 DGT Energy variables: 1x 5+2DGT, 6+1DGT, 7 DGT Accuracy: W-VA-PF: ±(1% RDG+2DGT); var: ±(2% RDG+2DGT); V LN-A: ±(0.5% RDG+1DGT), kWh: Class B (EN50470-3), Class1 (EN62053-21); kvarh: Class 2 (EN62053-23). System type: Unbalanced: 2-3-phase; 1-phase Voltage inputs (Un): 120/230VLLAC (AV6 model) 400VLLAC (AV5 model) Current inputs (In): In: 5AAC, Imax: 6AAC (shunt input technology) Method: TRMS Digital Pulse Output: Proportionate to measured active energy (EN62052-31) Serial Communication Port: RS485 (2-wire, Modbus), RTU protocol (Baud-rate 9.6, 19.2, 38.4, 57.6, 115.2 kbps) Power supply: Self power supply (from 40V to 480VAC through terminals VL2-L3) Temperature range: operating: -25°C to +55°C; storage: -30°C to +70°C Approvals: CE, cULus listed Protection degree: IP50 (front)

EM210_AV – Wiring LOAD 1 2 3 4 5 6 Phase 1 Phase 2 Phase 3 The use of external current transformers is mandatory 3 4 5 6 LOAD Neutral

New EM210_AV – Wiring 3-phase + N unbalance sys (3 CT connection) 3-phase + N unbalance sys (3-CT + 3-VT connection) 3-phase without N unbalance sys (3-CT connection) 3-phase without N unbalance sys (3-CT + 3-VT connection) 2-phase + N unbalance sys (2-CT connection) 2-phase + N unbalance sys (2-CT + 2-VT connection) L1 L2

EM210_AV – Applications New