MACS CPAP System Self Guided Tour.

Slides:



Advertisements
Similar presentations
MACS CPAP System Self Guided Tour. Program Objectives This program is a self guided tour of the MACS CPAP System. At the end of this tour you will be.
Advertisements

Practical Nursing Diploma Program - Semester 2 Lab Oxygen therapy, Incentive Spirometry, Pulse Oximetry &Sputum Collection.
Rhonda Contant, BScH, RRT
CPAP and BiPAP “A CPAP a day helps keep the ET tube away!” Thanks to former state medical director Keith Wesley for stolen info…..
Boussignac CPAP System
Anesthesia Apparatus Checkout Recommendations
PNeuton Transport Ventilator Model A Self Guided Tour.
Concepts and Use Presented and adapted by Todd Lang, MD.
PNeuton Transport Ventilator Model S Self Guided Tour.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
pNeuton Transport Ventilator
UNION HOSPITAL EMERGENCY DEPARTMENT KELLY MILLS RN CEN
Supplemental Oxygen & Ventilators
Bmd Crossvent 3.
pNeuton Transport Ventilator
Nesreen El-Sayed Morsy Aly Thoracic Medicine Department
Regulators.
Aircraft Systems Oxygen Systems A-4N/TA-4. Aircraft Systems Oxygen System LESSON OBJECTIVES To give the TP information on the Oxygen System to include.
Ventilator.
PART 3: Breathing Circuit
How Ventilators Work Chapter 3. To care for a ventilator patient, you need to know: The various functions of the ventilator used How the ventilator interacts.
Newport HT50 Ventilator Orientation & Training
Oxygen Therapy Linda Winn, RN, MSN Ed., BA Ed.. Oxygen Medication Requires MD order Side Effects Highly combustible gas Clear Odorless Set-up is part.
1 Life Products LP-6, LP 6 Plus and LP 10 Home Ventilator By Bryce Younger.
By: Susan P. Pilbeam, MS, RRT, FAARC John D. Hiser, MEd, RRT, FAARC
Dr Chaitanya Vemuri Int.Med M.D Trainee.  The choice of ventilator settings – guided by clearly defined therapeutic end points.  In most of cases :
Mosby items and derived items © 2007, 2004 by Mosby, Inc., an affiliate of Elsevier Inc. Airway Management and Ventilation Team Work Chapter 6.
The Unit Between The Device & Patient (NeoPAP)
MACS CPAP System Self Guided Tour. Program Objectives This program is a self guided tour of the MACS CPAP System. At the end of this tour you will be.
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
Know your Os? How much Oxygen is the patient on? How much does the patient need? How’s this mask work? Is this thing hooked up right?
Oxygenation And Ventilation
ANAESTHESIA BREATHING CIRCUITS
PART 3: Breathing Circuit
Problem: 360,000 patients have cardiac events every day.*
Prepared by Dr. Irene Roco
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
Application for HFCO therapy in airway clearance.
Student will be able to explain the various methods of oxygen administration and the role of the NA. Student will be able to list the safety precautions.
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
CPAP.
Mechanical Ventilator
PRESSURE CONTROL VENTILATION
Oxygen Therapy Aaqid Akram MBChB (2013) Clinical Education Fellow.
PART 3: Breathing System Parts
Unit 3 Lesson 2 Airway Adjuncts & Oxygen Therapy
Simplified Instruction for use* Evita V300
BASIC GAS METAL ARC WELDING
14 Refrigerant Recovery, Recycling, and Recharging.
Non-Rebreathing System
Respiratory Protection Training
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
Mechanical Ventilator 2
Monaghan 225 Ventilator Use Under Hyperbaric Conditions
Mechanical ventilator
Pneumatic schematic of the Dräger Infinity V500 intensive care ventilator. A. Gas-mixture and gas-metering assembly. Gas from the supply lines enters the.
“Respiratory equipments”
Simplified Instruction for use* Evita V300
T-6B On-Board Oxygen Generation System (OBOGS)
Non-Rebreathing System
Respiratory Disorders
Mechanical ventilator
Pulse Oximetry.
Concorp, Inc. - Respiratory Protection Training. Revision – B
Transport Ventilator and Beyond!
The high flow nasal cannula (HFNC) system incorporated an air/O2 blender with a flow meter and a heated humidifier. The high flow nasal cannula (HFNC)
We connected the supplemental oxygen supply at 3 places: near the ventilator, near the exhalation valve, and on the nasal mask port. We connected the supplemental.
T-6B On-Board Oxygen Generation System (OBOGS)
Presentation transcript:

MACS CPAP System Self Guided Tour

Program Objectives This program is a self guided tour of the MACS CPAP System. At the end of this tour you will be able to: Describe the main operating features of MACS Identify the controls and connections Describe the patient breathing circuit Set-up MACS for patient operation Define various clinical environments for CPAP application Clean and maintain the MACS

Features and Controls – Rear Panel Driving Gas Input Connection for 55 psi (3.8 bar) oxygen source gas Always use a high flow gas source (pressure take-off) that can provide 55 + 15 psi pressure at a minimum of 40 L/min

Features and Controls – Rear Panel Air Entrainment Ambient air is entrained for internal gas mixing External housing contains air filter Air filter replacement is part of the preventative maintenance

Features and Controls – Front Panel CPAP Control Adjusts the CPAP from 0 to 20 cm H2O Automatic sensitivity Flow adjusts automatically to meet patient demand up to 140 L/min Oxygen concentration is maintained at set % Oxygen control

Features and Controls – Front Panel % Oxygen Control Delivered oxygen choice 65% 100% Sets the spontaneous breath oxygen concentration

Features and Controls – Front Panel Pressure Gauge Shows pressure in patient circuit at the output of MACS Compare with control setting to insure proper operation Gives an indication of patient effort

Features and Controls – Front Panel Circuit Connection 1 Connection for the large bore hose of the patient circuit

Features and Controls – Front Panel Circuit Connection 2 Patient circuit small hose connection Connects to the expiratory valve on the patient circuit

Patient Breathing Circuit Patient circuit is a single limb system Both hoses attach to the front of MACS Patient end connects for clinical intervention Directly to an endotracheal tube (invasive) Face mask (noninvasive)

Patient Breathing Circuit Use only Airon Corporation patient circuits Calibration of the CPAP control is based upon the Airon patient circuit Using other manufacturers circuits may cause errors in pressure delivery high expiratory flow resistance interference with CPAP sensitivity increased oxygen usage

Patient Breathing Circuit Accessories to optimize patient care In-line medication nebulizer Fits between the mask and patient circuit Nebulizer can be removed to add medication while maintaining pressure CO2 monitoring For In-line sampling place the Tee between the mask and circuit Or use the nasal prongs under the mask Expiratory bacteria / viral filter can be added using the 90 degree expiratory port elbow

MACS CPAP System self guided tour, objectives completed so far: Program Objectives MACS CPAP System self guided tour, objectives completed so far: Describe the main operating features of MACS Identify the controls and connections Describe the patient breathing circuit With an understanding of MACS’s capabilities, let’s look at patient application.

Patient Application Initial Set-up Attach Airon patient circuit to MACS Attach a high pressure oxygen hose to the rear of MACS Attach the other end of the high pressure hose to the oxygen source

Patient Application Set % Oxygen Control Set % Oxygen control to the desired oxygen level All breaths receive set oxygen level + 10% Oxygen tank time almost doubles with 65% setting Caution - with rapid, large tidal volumes on 100% oxygen, the actual delivered percentage may be less than 100%

Patient Application Start CPAP Turn on oxygen source Attach patient breathing circuit to the patient using either a mask or endotracheal tube Adjust the CPAP control to the level desired If the patient is not attached to the circuit, or there is a large leak, a high flow of gas will occur

Patient Application Monitor patient Assess per your protocol patient breathing rate comfort oxygenation CO2

Let’s look at various clinical environments for CPAP application Clinical Issues Let’s look at various clinical environments for CPAP application Using CPAP Pediatric support Medication nebulization CO2 monitoring Altitude operation

Clinical Issues Using CPAP Used on spontaneous breathing patients in respiratory failure including Congestive Heart Failure (CHF) COPD and Asthma Near Drowning CO poisoning Set CPAP level as needed Can be used with mask or ET-Tube

Clinical Issues Pediatric Support MACS is safe for pediatric - adult patients Use the lowest possible settings Monitor closely for patient synchrony

Clinical Issues Providing nebulized medications A medication nebulizer may be placed between the patient connection and the patient Patient will inhale medication during every breath and exhale back out through patient circuit Expiratory filter may be added for personnel safety

Clinical Issues CO2 Monitoring Any type of CO2 analyzer may be used With in-line style analyzers place the sensor Tee between the patient circuit connection and the patient With sidestream analyzers place the nasal prong sampling tube under the face mask

Clinical Issues Altitude Operation MACS can be used for air transports in unpressurized cabins up to 15,000 feet Pressure settings will not change as altitude changes

Patient Safety Patient Safety Features Internal Safety Pressure Release – limits circuit pressure to 40 cm H2O Anti-Suffocation System – in the event of device malfunction, an internal valve will allow ambient air to enter the patient circuit

Cleaning and Maintenance Clean MACS between patients using a soft cloth and a mild detergent / disinfectant Do not immerse MACS in water Disposable patient circuit is for single use application and should not be cleaned, disinfected or reused MACS should receive preventative maintenance every 2 years

Program Objectives MACS CPAP System self guided tour completed; you should now be able to: Describe the main operating features of MACS Identify the controls and connections Describe the patient breathing circuit Set-up MACS for patient operation Define various clinical environments for CPAP application Clean and maintain MACS Next Step – consider reviewing the MACS Case Study and completing the competency evaluation

Thank you for you interest in the Contact Information Thank you for you interest in the MACS CPAP System For more information visit www.AironUSA.com or call Airon Corporation at: 1-321-821-9433 1-888-448-1238 (toll free North America) CD-M-015 Rev B