Ch 36 Radiation Protection Design

Slides:



Advertisements
Similar presentations
Quality Control in Diagnostic Radiology
Advertisements

Radiation Protection Of Health Care Workers Kyle Thornton RADL 70.
Detecting and Measuring Ionizing Radiation -2
Rad Protection in Fluoro & INTRO RHB regs
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
Digital FLUORO Summer 2008.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Computed Tomography RAD309
Factors affecting the X-Ray output
X-Ray Production & Emission
The X-ray Imaging System
X-Ray Production & Emission
Conventional and Computed Tomography
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
Quality Control Rad T 110.
RAD 350 Chapt. 25 Fluoroscopy Fluoro’s primary function is to enable one to view the patient in “real time” with dynamic motion Invented by Thomas Edison.
Introduction to Fluoroscopy & Radiation Safety
Control of Scatter Radiation
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Radiation Monitoring and Protection
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
CHAPTER 3 EQUIPMENT OPERATION AND QUALITY CONTROL
INVERSE SQUARE LAW. The picture above demonstrates the typical x-ray tube used to produce a point source of x-rays. Then as radiation exits the tube it.
Prime Exposure Factors 1
Basic radiation protection & radiobiology
Stacy Kopso, M.Ed., RT (R)(M)
1 WEEK 7 RADIATION BIOLOGY & PROTECTION Part 1 FINAL.
RHB SYLLABUS on Fluoroscopy & Radiation Protection
Radiographic Equipment
Designing for Radiation Protection. Design Standards for Radiation Protection – Leakage Radiation.
Introduction to nuclear medicine technology NMT 231 Aya Ahmed Saeed.
Determining Radiation Intensity
Session II.3.7 Part II Quantities and Measurements
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Stacy Kopso, M.Ed., R.T.(R)(M).  Xray photon loses energy and changes direction  Responsible for most of the scatter that fogs the image  Related to.
DIGITAL IMAGING.
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Tube Exposure Factors Math Technique Contrast and Density
Protection1 Radiation Protection. Protection2 BENEFITS VS. ADVERSE EFFECTS.
3/2003 Rev 1 II.3.7 – slide 1 of 40 Session II.3.7 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities.
Radiation detectors Ion chamber 2. Geiger Muller counter (GM).
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Sensors and Detectors - 2
RADIATION PROTECTION 04/12/2016.
Diagnostic Equipment Quality Control
Patient & Occupational radiation dose management Chapter 37 & 38
X-Ray Generators and Ancillary Radiographic Equipment
X-RAY PRODUCTION AND EXPOSURE FACTORS
Protection of Patients
Sensors and Detectors - 2
Stat Ch 8 & 9 RHB – Rad Prot Syllabus
X-Radiation.
WEEK 7 RADIATION BIOLOGY & PROTECTION Part 1
Rad Protection & Radiobiology review
Factors Effecting the Production
Exposure Factors Chapter 4
Resident Physics Lectures
Resident Physics Lectures (Year 1)
Resident Physics Lectures
Resident Physics Lectures (year 1)
Mobile Fluoroscopy Based on:
Resident Physics Lectures (Year 1)
Radiation Protection in Fluoroscopy
Conducting the Fluoroscopic Examination & Basic Operational Procedures
Occupational Radiation Dose Management
Occupational Radiation Dose Management
Mobile Fluoroscopy.
Occupational Radiation Dose Management
Presentation transcript:

Ch 36 Radiation Protection Design RTMR 284 Winter 2013

Ch 36-Designing for Protection…….Features: Protective X-Ray tube housing Protective housing to reduce leakage radiation Must be less than 100 mR/hr at a distance of 1m from protective housing. Control Panel Must show exp. Conditions and when tube is energized Beam ON must be clear to techs. SID Indicator Indicator must be present (tape measure or readout) Must be accurate within 2% of the indicated SID

Protection Features cont. Collimation Light field, variable aperture X-ray beam and light filed must coincide w/in 2% of SID PBL-Positive Beam Limitation Auto collimation circa 1974-1994 Must be accurate w/in 2% of SID Beam Alignment How do we know the tube is aligned with the image receptor ???

Protection Features cont. Filtration Inherent plus added Total must be at least 2.5 mm above 70 kVp Reproducibility Constant output radiation intensity Should not exceed 5% through same technique Linearity Constant output for varied mA settings while time is adjusted to keep mAs the same. Max variation is 10% from one mA to adj. mA station

Portable / Fluoro Protection Operator Shield It must not be possible to expose in a room outside of the operator booth Portable x-ray must have >2m tether for exposure Fluoroscopic Protection SSD-source to skin distance Divergence of x-ray beam means the ESE or entrance skin exp. is lessened for the required exit exposure as SSD is increased SSD must be not less than 38cm on stationary fluoroscopes and not less than 30cm on mobile fluoroscopes.

Portable / Fluoro Protection

Fluoro Protection cont. Additional Fluoro Protection Primary Protective Barrier IR assembly must be 2 mm Pb eq. w/ interlock Filtration Total filtration at least 2.5 mm Al eq. Collimation Visible unexposed boarder w/ II 35 cm above TT Exposure Control Dead man… Bucky Slot Cover / Protection Curtain At least 0.25 mm Pb eq. Cumulative Timer Audible signal if time > 5 min. Intensity At tabletop must not exceed 2.1 R/min for ea. mA @ 80kVp

DAP Dose Area Product The intensity of the x-ray beam at the tabletop of a fluoroscope should not exceed 2.1 R/min per mA @ 80kVp. If there is no optional high-level control, the intensity must not exceed 10R/min (20 R/min with high level control) Quantity that reflects not only the dose, but also the volume of tissue irradiated. R-cm^2 units DAP increases with increase field size Used for monitoring equipment

Protective Barriers 3 types of radiation to consider when designing barriers primary radiation the useful beam secondary radiation scatter radiation the patient is the most important scattering object Intensity of SR 1m from the pt. ~0.1% of intensity of the useful beam at the pt. leakage radiation limit of 100mR/hour (not recommended)

Protective Barriers Primary Protective Barrier protects against the primary beam floor wall behind an upright bucky Secondary Barriers protects against secondary radiation control booth walls without upright bucky

Factors Affecting Barriers Distance distance between source of radiation and barrier Use what is the area used for? Controlled area Uncontrolled area Use factor Workload the greater the # of exams/week the thicker the shielding

Definitions Controlled area area occupied mostly by Radiology Personnel and patients. Exposure rate must be less than 100 mR/week Uncontrolled area occupied by anyone maximum exposure rate is 2 mR/weekUse Factor Use Factor The percentage of time that the x-ray beam is on and directed toward a particular wall

Radiation Detection & Measurement Instruments are Designed to: Detect radiation Measure radiation Both detect and measure radiation

4 Types of Radiation Detection Devices Gas-filled ionization chambers proportional counters Geiger-Muller detectors Thermoluminescence dosimeters (TLD) Scintillation detectors Optically Stimulated Luminescence (OSL)

Gas-filled 3 types of gas-filled radiation detectors ionization chambers proportional counters Geiger-Muller detectors

Gas Filled All 3 types of Gas filled Radiation Detection Devices are based on the same principle Radiation passes through gas and ionizes atoms of gas Electrons released in ionization are detected as an electrical signal Electrical signal is proportional to radiation intensity Usually, the larger the chamber, the more sensitive the instrument Because there are more gas molecules for ionization A pressurized chamber has more molecules available as well

Scintillation detectors Some materials emit a flash of light in response to the absorption of ionizing radiation The light emitted is proportional to amount of energy absorbed most often used to indicate individual ionizing events used in fixed or portable radiation detection devices Used in detector arrays of many CT scanners Basis for the gamma camera in Nuclear Med

Thermoluminescence dosimeters (TLD) Some materials glow when heated After this material is exposed to ionizing radiation, it is heated The light let off is proportional to the ionizing radiation it was exposed to

Optically Stimulated Luminescence (OSL) Developed in the late 1990s Uses aluminum oxide to detect radiation Irradiation of aluminum oxide stimulates electrons into an excited state During processing, laser light stimulates these electrons returning them to normal state with the emission of visible light. The intensity of visible light emission is proportional to the radiation dose received.

Optically Stimulated Luminescence (OSL) The OSL process is similar to the TLD Both are based on stimulated luminescence. Advantages of OSL over TLD are: More sensitive than TLD More precise Reanalysis for confirmation of dose is available Qualitative information about exposure conditions A wide dynamic range Excellent long-term stability

The End Projects Due in Class next week….