Intraocular pressure & tonometry

Slides:



Advertisements
Similar presentations
Il controllo circadiano della pressione intraoculare: implicazioni farmacologiche N. ORZALESI, P. FOGAGNOLO Università degli Studi di Milano Ospedale San.
Advertisements

Goldmann Applanation Tonometry
A Wireless, Implantable Intra- Ocular Pressure Sensor for the Management of Glaucoma Gabriel Simon, M.D. Ph.D. Sept 16, 2008 ESCRS.
Scanning Tonometer for Eye Pressure (STEP™) Problem Measurement of eye pressure by Goldmann applanation tonometry is a technique first embodied in the.
Goldmann Tonometer.
Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Canadian Ophthalmological Society Evidence-based Clinical Practice Guidelines for the Management of Glaucoma in the Adult Eye.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Applanation tonometry:
Ocular Pulse Amplitude and Retrobulbar Blood Flow Change in Dipper and Nondipper Individuals Ibrahim F. Hepsen Remzi Karadag
Recent Advances in IOP measurements
Comparison between Dynamic contour tonometry, Goldmann applanation tonometry and Ehlers-corrected Goldmann applanation tonometry in eyes after Laser In.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
SEI IOP and its correlations in a population based study in Central India. The Central India Eye and Medical Study. Krishna Bhojwani, Vinay Nangia, Jost.
The Canadian Association of Optometrists
CR The Glaucoma Tonometer. What sets it apart? Reichert’s 7CR Auto Tonometer + Corneal Response Technology takes corneal biomechanical properties into.
Understand the Cornea Understand the Pressure
INTRAOCULAR PRESSURE LECTURE
ISAT 303-Lab3-1  Measurement of Condition: Lab #3 (2005):  List of parameters of condition: –Linear distance, angular displacement, vibration, displacement,
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
Methods of measuring intra ocular pressure. What is intra ocular pressure ? Definition Intra ocular pressure refers to the pressure exerted by the intra.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Presents: Diaton Tonometer Tonometry through the Eyelid! September 2006.
Glaucoma Screening With a New Non-Contact Air Impulse Tonometer Pandelis A. Papadopoulos,1,2, Dimitrios P. Bessinis 3, Alexandros A. Papadopoulos 1, Konstantinos.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
Assessment of wave propagation in mice cornea and lens using phase stabilized swept source optical coherence tomography Ravi K. Manapuram, Floredes M.
In-vitro measurement of Intra- Ocular Pressure Alex Luce Undergraduate Research Symposium 2008.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Tonometry Objective measurement of IOP based, most commonly, on the forces required to flatten the cornea,or the degree of corneal indention produced.
Comparison of the Diaton Transpalpebral Tonometer Versus TonoPen- Applination Theodore H. Curtis, M.D.1, Douglas L Mackenzie, M.D.1, Robert J. Noecker.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Ahmed El-Massry, M.D. Professor of Ophthalmology - Faculty of Medicine University of Alexandria Egypt long-Term Results of Corneal Biomechanical Changes.
Examination techniques in ophthalmology E. Vlková et al.
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
TONOMETER.
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
Minimizing Risk in Visian ICL Implantation.
Mathematical Description of the Ocular Response Analyzer Applanation Signal in Post-LASIK Ectasia Mujtaba A. Qazi, M.D. 1,2 David A. Luce, Ph.D. 3 Jay.
Understanding GLAUCOMA… The Science Behind Current Testing and Therapy Mindy J. Dickinson, OD Midwest Eye Care, PC Omaha/Council Bluffs.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Concepts 3 Material 9 Method 10 Results/Discussion 11 Conclusion Questions.
Date of download: 7/8/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Dynamic Contour Tonometry: A Comparative Study on.
Copyright © 2005 American Medical Association. All rights reserved.
Use of the ICare Home Rebound Tonometer for home self-monitoring of intraocular pressure in a Singaporean population Jeanne Joyce OGLE1, Wai Cheng SOO.
CRF variations ( initial CRF – final CRF )
Glaucoma Conference Intraocular pressure and tonometry
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Safety of medication reduction for Primary Angle Closure (PAC) –
55th ASMR National Scientific Conference
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
INTRODUCTION TO GLAUCOMA
2/24/2013.
Effects of corneal collagen crosslinking on Ocular Response Analyzer waveform-derived variables in keratoconus and post-LASIK ectasia Spatial treatment.
Keratometric Changes in Noninflammatory Corneal Ectasic Diseases After Intraocular Pressure Reduction Authors has no financial interest. Renata T Kashiwabuchi,
Associate Professor of Ophthalmology
Federal University of São Paulo, Brazil
Corneal Biomechanical Assessment using Dynamic Ultra High-Speed (UHS)
Yakov Goldich MD,Yaniv Barkana MD, Isaac Avni MD, David Zadok MD,
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Hyuck Jin Choi, Joo Youn Oh, Won Ryang Wee, Mee Kum Kim,
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
The Effect of Corneal Thickness on Ocular Drug Penetration
Box and whiskers plot for bIOP, Goldmann applanation tonometry IOP (GAT) and Goldmann adjusted (GATAdj) in ocular hypertension (OHT), primary open-angle.
Presentation transcript:

Intraocular pressure & tonometry 2011.4.22 녹내장 컨퍼런스 Intraocular pressure & tonometry 서울성모병원 안과 R4 정수경

Classification of tonometer 1) Indentation tonometer 2) Applanation tonometer 3) Noncontact tonometer 4) Miscellaneous tonometer

Indentation tonometry Schiotz indentation tonometry Potential source of error “Average” coefficient of ocular rigidity (K) Expulsion of intraocular blood Relatively steep or thick cornea -> falsely high IOP reading 5.5 7.5 10 15 로 증가

Applanation tonometer Goldmann applannation tonometer Maklakoff applanation tonometer Perkins applanation tonometer Mackay-Marg tonometer (Tono pen) Pneumotonometer PASCAL tonometer

Applanation tonometer Maklakoff applanation tonometer Consisted of a dumbbell shaped metal cylinder The resultant circular white imprint on the endplate corresponded to the area of flattened cornea. IOP read from a conversion table Perkins applanation tonometer Use the same biprism as the Goldmann applanation tonometer Dumbbell: 아령

Applanation tonometer Mackay-Marg tonometer (Tono pen) A plate of 1.5 mm surrounded by a rubber sleeve. The force required to keep the plate flush with the sleeve was electronically monitored. Tono pen - a handheld instrument with a strain gauge that creates an electrical signal as the footplate flatten the cornea A built-in single-chip microprocessor senses the proper force curves and averages 4 to 10 readings.

Applanation tonometer Pneumotonometer Similar to the Mackay-Marg tonometer in that a central sensing device measures the IOP The force required to bend the cornea is transferred to a surrounding structure. The sensor is air pressure.

Applanation tonometer PASCAL tonometer FDA clearance in 2003, commercially in 2004 Portable slit lamp mounted device Samples IOP 100 times /s +ocular pulse amplitude +systemic pulse rate Digital output of IOP + graphic output of the ocular pressure pulse PASCAL has a concave tonometer tip that matches corneal curvature and measures pressure directly by means of a miniaturized, built-in sensor. When it touches the cornea it allows the cornea to assume its natural shape when pressure on both sides is equal and distortion of the cornea is minimal. DCT is different from applanation tonometry. “It’s a new principle, a new concept,” said Dr. Stamper, who has conducted two DCT studies.  OPA : ocular pulse amplitude - the difference between diastolic IOP and systolic IOP OPA is suggestive of choroidal blood flow PASCAL repeatedly samples intraocular pressure at a rate of 100 times per second. The ocular pulse amplitude (OPA) and the systemic pulse rate are continuously measured and recorded by the instrument. In addition, the ocular pressure pulse is graphically represented on the patient report.

Applanation tonometer PASCAL tonometer The cornea is a spherical shell made of a material that resists stretching and is fairly flexible to bending deformations. There is a container that is filled with casting resin surrounding an entire globe. A pressure (p) measured by a pressure sensor could exactly correspond to the true IOP (P), if a small part of the wall by a pressure sensor with identical surface shape is replaced. Dynamic contour tonometry: principle and use Clinical and Experimental Ophthalmology2006;34: 837–840

Applanation tonometry PASCAL tonometer – Intraocular pressure More accurate than other tonometers. It provided the most accurate IOP readings within ± 0.7 mmHg, whereas Goldmann readings were consistently below true IOP by an average of 4 mmHg in the study performed on eye bank eyes. A little higher in general than applanation tonometry in people with thin or average thickness corneas. Healthy eye (CCT 439-642 um) ; excellent concordance with Goldmann applanation tonometry value LASIK eye; better suited to monitor IOP than other tonometry value Concordance : 일치, 부합 DCT is a newly Food and Drug Administration (FDA) – approved device that is designed to measure IOP, independent of corneal thickness, corneal curvature, and ocular rigidity. Kaufmann, C. et al. Invest Ophthalmol Vis Sci 2004;45:3118–3121. Siganos, D. et al. J Cataract Refract Surg 2004;30(4):746–751.

Applanation tonometry PASCAL tonometer – Ocular pulse amplitude Indirect measurement of the choroidal perfusion and reflects the ocular blood flow An independent risk factor for glaucoma and possibly for NTG A decrease in OPA of patients suffering from NTG is detected. Br J Ophthalmol 2002;86:981–984 The OPA was correlated with GAT and DCT IOP measurement, and correlated neither with blood pressure nor with age in normal healthy eyes. Physiological diurnal variability and characteristics of the ocular pulse amplitude (OPA) with the dynamic contour tonometer (DCT-Pascal1) Int Ophthalmol (2007) 27:357–360 Concordance : 일치, 부합 DCT is a newly Food and Drug Administration (FDA) – approved device that is designed to measure IOP, independent of corneal thickness, corneal curvature, and ocular rigidity.

Miscellaneous tonometers Ocular response analyser (ORA) A rapid air (20ms jet of air) impulse to apply force to the cornea -> monitor the deformation of cornea 2) records two applanation events the first- inward moving the other- returning The difference between the appplanation pressure ; CH 4) The average of these 2 pressures; Goldmann-equivalent intraocular pressure http://www.aao.org/publications/eyenet/200505/glaucoma.cfm

Miscellaneous tonometers Ocular response analyser (ORA) Noncontact measurement of the biomechanical properties of the cornea the corneal hysteresis (CH) the corneal resistance factor (CRF) the corneal-compensated intraocular pressure (IOPCC) the Goldmann-equivalent intraocular pressure (IOPG) the corneal hysteresis (CH) ; the viscosity as a measure of absorption and energy conversion of the cornea and the whole eye the corneal resistance factor (CRF); to display the elastic properties POAG patients have properties with lower CH. Theoretically, CH improved buffering might result in reduced stress/strain on both the optic nerve and peripapillary scleral tissues; this, in turn, reduces the risk for glaucomatous structural damage. http://www.aa Corneal-compensated IOP (IOPcc) is derived from both IOPand corneal biomechanical data. Similar to DCT-IOP findings, several published clinical studies have reported that IOPcc is unrelated to central corneal thickness

Miscellaneous tonometers Rebound tonometers Icare tonometer (Icare Finland, Helsinki) Measure IOP without the use of topical anesthetics Comfortable and highly reproducible in healthy school-aged children Screen tool in children The opportunity to monitor IOP at home. 1mm 직경의 24mm 길이의 일회용 probe 이용함

Miscellaneous tonometers Rebound tonometers Icare tonometer (Icare Finland, Helsinki) Reproducibility and Tolerability of the ICare Rebound tonometer in School Children J Glaucoma 2007;16:185–188 Impact or dynamic tonometry An assembly of 2 coils coaxial to a probe shaft that bounce a magnetic probe off the cornea and detect the deceleration of the probe caused by the eye. RBT : rebound tonometry It contains an assembly of 2 coils coaxial to a probe shaft that bounce a magnetic probe off the cornea and detect the deceleration of the probe caused by the eye (Figs. 1, 2). The probe slows down faster as the IOP increases and, consequently, the higher the IOP, the shorter is the duration of impact.

Miscellaneous tonometers IOP monitoring devices Prototypes Contact lens Implantable device Scleral band SENSIMED Triggerfish sensor device Shield 의 reference논문 참조 !! Swiss 에서 만듬

Comparison of tonometers Most precise method; manometric measurement of the cannulated anterior chamber Most common used method; Goldmann & Tono - pen Less common used method; noncontact tonometer, Perkins, pneumotonometry, Schiotz tonometer Goldmann Vs Tono-pen Normal range; good correlation Higher IOP – tono-pen underestimate Lower IOP- tono-pen overestimate Manometric :압력계로 잰 Cannula: 금속관

Tonometry for special clinical circumstances Irregular corneas ; Pneumatic tonometer is useful (West CE et al, 1972 AJO) Goldmann > tonopen (Geyer O et al, 1992 BJO) Soft contact lens; Pneumatic tonometer = Tono- pen (Rubenstein et al, 1985 Arch Oph) (Khan et al, 1989 AJO) Gas filled eye; Pneumatic tonometer < Goldmann = Tonopen (Del Priore LV et al, 1989 Ophthalmology)