Ganesh Manoharan Consultant Cardiologist

Slides:



Advertisements
Similar presentations
Thirty-day Outcomes from the Multi-centre European Pivotal Trial for Transapical Transcatheter Aortic Valve Implantation with a Self-expanding Prosthesis.
Advertisements

Marie Erpicum – Perfusionniste Département de chirurgie cardiovasculaire et thoracique - CHU de Liège Marie Erpicum Perfusionnist Cardiovascular & Thoracic.
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve ® has been approved. The CoreValve ® System is not currently approved in the USA,
STS 2015 John V. Conte, MD Professor of Surgery Johns Hopkins University School of Medicine On Behalf of the CoreValve US Investigators Transcatheter Aortic.
Three-year clinical and echocardiographic follow-up of aortic stenosis patients implanted with a self-expending bioprosthesis Sabine Bleiziffer German.
ACC 2015 Michael J Reardon, MD, FACC On Behalf of the CoreValve US Investigators A Randomized Comparison of Self-expanding Transcatheter and Surgical Aortic.
6-Month Outcomes Following Transcatheter Aortic Valve Implantation With a Novel Repositionable Self-Expanding Bioprosthesis Ian T. Meredith, MBBS, PhD,
Long-Term Outcomes Using a Self- Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Deemed Extreme Risk for Surgery: Two-Year Results From.
One Year Outcomes in Real World Patients Treated with Transcatheter Aortic Valve Implantation The ADVANCE Study Axel Linke University of Leipzig Heart.
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
University Heart Center Hamburg
Dr Martyn Thomas Director of Cardiac Services Guys and St Thomas NHS Foundation Trust A Member of Kings Health Partners London.
TAVR Pearls Addressing the Shortcomings of the Current TAVR Generation
Trans-catheter Aortic Valve Replacement: a UK update. Dr Martyn Thomas Guys and St Thomas’ Hospital.
The Risk and Extent of Neurological Events Are Equivalent for High-Risk Patients Treated With Transcatheter or Surgical Aortic Valve Replacement Thomas.
Prosthesis-Patient Mismatch in High Risk Patients with Severe Aortic Stenosis in a Randomized Trial of a Self-Expanding Prosthesis George L. Zorn, III.
Axel Linke University of Leipzig Heart Center, Leipzig, Germany Sabine Bleiziffer German Heart Center, Munich, Germany Johan Bosmans University Hospital.
UC c EN. Through Medtronic sponsored research, the Transcatheter Aortic Valves clinical portfolio is studying over 11,000 subjects at over 125.
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
INTERNATIONAL. CAUTION: For distribution only in markets where CoreValve® is approved. Not for distribution in U.S., Canada or Japan. Medtronic, Inc
Transcatheter Cardiovascular Therapeutics 2008 (October 12-17, 2008 · Washington, DC) First-in-Human Report: Initial Experience with a Stentless and Retrievable.
Twelve Months and Beyond: Long-Term Results of the Direct Flow Medical Repositionable and Retrievable Pericardial Valve for Percutaneous Aortic Valve Replacement.
Longest Follow-up After Implantation of a Self-Expanding Repositionable Transcatheter Aortic Valve: Final Follow-up of the Evolut R CE Study Stephen Brecker,
TAVR in Patients With Chronic Kidney Disease
TAVR for the Treatment of Pure Native Aortic Valve Regurgitation
Ian T. Meredith AM MonashHeart, Clayton, Victoria, Australia
CRT 2011 Washington DC, February 27th – March 1st
Extending the Boundaries of TAVR: Future Directions
Trans- catheter aortic valve replacement vs
A Review of Medtronic CoreValve TAVI Clinical Results:
On behalf of the FORWARD Study Investigators
Late breaking news in heart valve disease
Self-Expanding TAVR: Conduction Abnormalities Jeffrey J. Popma, MD
The Medtronic Ventor EngagerTM TAVI System
TAVR Medtronic CoreValve® Subclavian Approach Clinical Data
The Lotus Device Design & FIM Experiences with a Repositionable Self Expanding Percutaneous Aortic Valve Ian T. Meredith MBBS, BSc(Hons), Ph.D, FRACP,
Transcatheter Aortic Valve Replacement Using the Lotus Valve with Depth Guard First Report from the RESPOND Extension Study Nicolas M Van Mieghem, MD,
Direct Flow Medical Experience with a Conformable, Repositionable, Retrievable, Percutaneous Aortic Valve Reginald Low MD University of California,Davis.
Are we ready to perform TAVI in Intermediate Risk Patients?
Updates From NOTION: The First All-Comer TAVR Trial
Transcatheter or Surgical Aortic Valve Replacement in Intermediate Risk Patients with Aortic Stenosis Description: The goal of the trial was to assess.
Portico™ Transcatheter Aortic Valve Replacement Program CRT 2013
Review of the Latest OUS Data from the Self-Expanding Valve Studies
First Report of One-Year Outcomes of the REPRISE I Feasibility Study of the Repositionable Lotus Aortic Valve Replacement System Ian T. Meredith.
30-Day Safety and Echocardiographic Outcomes Following Transcatheter Aortic Valve Replacement with the Self-Expanding Repositionable Evolut PRO System.
Trans-Apical Aortic Valve Implant:
First Report of Three-Year Outcomes With the Repositionable and Fully Retrievable Lotus™ Aortic Valve Replacement System: Results From the REPRISE I.
Early Outcomes with the Evolut R Repositionable Self-Expanding Transcatheter Aortic Valve in the United States Mathew Williams, MD, For the Evolut R US.
University of Pennsylvania
5th Meeting on Acute Cardiac Care and Emergency Medicine, 2016 Vilnius
Giuseppe Tarantini MD, PhD
Review of the Data from the Subclavian Approach Clinical Trials
Direct Flow Medical Experience with a Conformable, Repositionable Retrievable Percutaneous Aortic Valve Reginald Low MD University of California, Davis.
Keith Dawkins MD FRCP FACC FSCAI Global Chief Medical Officer
Two-Year Outcomes With the Fully Repositionable and Retrievable Lotus™ Transcatheter Aortic Replacement Valve in 120 High-Risk Surgical Patients With Severe.
Opportunities to Study Valve Iterations and Modifications in the US
Longevity of transcatheter and surgical bioprosthetic aortic valves in patients with severe aortic stenosis and lower surgical risk Lars Sondergaard,
Lessons from complications: Balloon-Expandable Edwards SAPIEN and the Self-Expanding Medtronic CoreValve Sunday February 21, :10 – 4:20 pm, Diplomat.
Medtronic - Core Valve Eberhard Grube, MD, FACC, FSCAI
CoreValve Continued Access Study Shows Continued Improvement in 1-Year Outcomes With Self-Expanding Transcatheter Aortic Valve Replacement Steven J. Yakubov,
Progress with the Sadra Medical Lotus™ Valve System
Axel Linke University of Leipzig Heart Center, Leipzig, Germany
Ganesh Manoharan Consultant Cardiologist
One Year Outcomes in Real World Patients Treated with Transcatheter Aortic Valve Implantation The ADVANCE Study Axel Linke University of Leipzig Heart.
Second Generation Valves: What Will Be Different?
University Heart Center Hamburg
Balloon-Expandable Transcatheter Valve System : OUS Data
Late Follow-Up from the PARTNER Aortic Valve-in-Valve Registry
Samir R. Kapadia, MD On behalf of The PARTNER Trial Investigators
Five-Year Outcomes after Randomization to Transcatheter or Surgical Aortic Valve Replacement: Final Results of The PARTNER 1 Trial Michael J. Mack, MD.
Presentation transcript:

A Review of All Available Self-Expanding Transcatheter Valve Clinical Results Ganesh Manoharan Consultant Cardiologist Regional Cardiology Department Royal Victoria Hospital Belfast, UK

Disclosures I am a consultant for: St. Jude Medical Medtronic CardioVascular GDS Inc

Self-Expanding TAVR Systems Clinically approved (European CE Mark) Transfemoral (+Other Access Route) Transapical Emerging Systems Transfemoral

Transfemoral (+Other Access)

Medtronic CoreValve System Trileaflet heart valve Tissue valve sutured to frame Single layer of porcine pericardium

CoreValve ® Full Range of Valve Sizes 26mm Valve 29mm Valve 31mm Valve 20 21 22 23 24 25 26 27 28 29 Annulus Size (mm) AccuTrak® Stability Layer 7mm 15Fr 12Fr 18Fr Over-the-wire 0.035 compatible 18Fr delivery system for all valve/annulus sizes and access routes 20 21 22 23 24 25 26 27 28 29 Annulus Size (mm)

Supra-Annular Valve Design Flexible frame conforms to native annulus shape while maintaining bioprosthesis in a higher position This decoupling of the valve from native annulus shape minimizes the impact of ellipticity at the valve level post deployment1 Data on file at Medtronic

CoreValve® Access Options Direct Aortic Subclavian Transfemoral

Baseline Patient Characteristics 18 Fr S&E1 ANZ2 Spanish Registry3 French Registry4 Belgian Registry6 German Registry8 UK Registry7 Italian Registry8 N 126 118 108 66 141 588 460 772 Age (years) 81.9 ± 6.4 82.3 ± 7.7 78.6 ± 6.7 82.5 ± 5.9 82 ± 6 81.4 ± 6.4 83 Female 57.1% 40.7% 54.6% 51.5% 56% 55.8% 48% Logistic EuroSCORE (%) 23.4 ± 13.8 18.4 ± 11.9 16 ± 13.9 24.7 ± 11.2 25 ± 15 20.8 ± 13.3 20.3 22.9 ± 13.5 NYHA Class III and IV 74.6% 83.9% 58.4% – 78% 88.2% 74% 70.6% LVEF % 51.6 ± 13.1 57.8 ± 13.0 51 ± 15 59 ± 13 52.1 ± 15 51 ± 13 Mean Pressure Gradient (mmHg) 46.8 ± 15.9 50.6 ± 16.2 55 ± 14.3 46 ± 15 49 ± 16 48.7 ± 17.2 52 ± 17 Aortic valve area (cm2) 0.72 ± 0.17 0.71 ± 0.21 0.63 ± 0.2 0.71 ± 0.16 0.63 ± 0.13 0.64 ± 0.18 0.71 Patients currently treated with CoreValve are all high risk patients See reference slide for sources. 9

Percent of Patients (%) Procedural Success 98.1% 97.0% 98.0% 98.7% 99.0% 98.1% 100% 95.8% 83.1% * 80% 60% Percent of Patients (%) 40% 20% 0% 18 Fr S&E1 ANZ2 Spain3 French4 Belgian5 Germany6 UK7 Italian8 N = 126 N = 118 N = 108 N = 78 N = 141 N = 588 N = 460 N = 772 Procedure Success is not defined consistently across all studies. * Technical Success is reported here. 1. Medtronic Data on File. COR 2006-02: 18 Fr Safety & Efficacy Study Re-Analysis, August 14, 2009. 2. Meredith I. VARC-adjudicated Outcomes in Inoperable and High Risk AS Patients. Transcatheter Cardiovascular Therapeutics 2010, Washington, DC. 3. Avanzas P, Munoz-Garcia AJ, Segura J, et al. Percutaneous implantation of the CoreValve® self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol. 2010;63:141-148. 4. Eltchaninoff. French Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 5. Bosmans. Belgian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 6. Zahn. German Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 7. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 8. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 10

30-Day All-Cause Mortality 25% 20% 15.2% 15.1% 15% 12.4% % 10% 9.0% 7.4% 7.2% 5.5% 5.6% 5% 0% 18 Fr S&E1 N = 125 ANZ2 N = 118 Spain3 N = 108 French4 N = 66 Belgian5 N = 119 German6 N = 588 UK7 N = 460 Italian8 N = 772 1. Medtronic Data on File. COR 2006-02: 18 Fr Safety & Efficacy Study Re-Analysis, August 14, 2009. 2. Meredith. VARC-adjudicated Outcomes in Inoperable and High Risk AS Patients. TCT 2010, Washington, DC. 3. Avanzas P, Munoz-Garcia AJ, Segura J, et al. Percutaneous implantation of the CoreValve® self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol. 2010;63:141-148. 4. Eltchaninoff. French Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 5. Bosmans. Belgian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 6. Zahn. German Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 7. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 8. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 11

Percent of Patients (%) One Year Survival 100% 90% 85.1% 81.6% 79.0% 80% 71.9% 70% 60% Percent of Patients (%) 50% 40% 30% 20% 10% 0% 18 Fr S&E1 N = 126 Belgian2 N = 141 UK3 N = 460 Italian4 N = 772 Survival rates comparable with octogenarians who have had sAVR or sAVR+CABG5 Survival rates reported are based on Kaplan-Meier Analysis. 1. Medtronic. Data on file. COR 2006-02: 18 Fr Safety & Efficacy Study Re-Analysis, August 14, 2009. 2. Bosmans. Belgian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 3. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 4. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 5. Moat, Neal. UK TAVI Registry, TAVI Mid and Long-term Clinical Outcomes. EuroPCR 2010. 12

30-Day Stroke Rate Stroke Rate at 30 days 20% 15% 10% 5% 0% 9.6% 10% 5% 4.5% 4.0% 4.0% 2.6% 1.9% 1.7% 0% 18 Fr S&E*1 N = 125 ANZ2 N = 118 French3 N = 66 Belgian4 N = 119 German5 N = 588 UK6 N = 460 Italian7 N = 772 Stroke is not defined consistently across all studies *Stroke is defined as permanent neurologic defects, included patients who had reversible neurologic events if there was structural evidence of an intracranial event Medtronic. Data on file. COR 2006-02: 18 Fr Safety & Efficacy Study Re-Analysis, August 14, 2009. Meredith. VARC-adjudicated Outcomes in Inoperable and High Risk AS Patients. TCT 2010, Washington, DC. Eltchaninoff. French Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Bosmans. Belgian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Zahn. German Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 13 13

Post-Procedure Aortic Regurgitation 0% 0% 0% 0.3% 100% 0% 2% 6% 8.6% 90% 15.2% 24.1% 80% 42.9% AR grade 4 70% 52% 60% AR grade 3 54.9% 46.3% Percent of Patients (%) 50% AR grade 2 40% AR grade 1 30% 39.0% None 20% 42% 27.8% 27.6% 10% 9.5% 0% 18 Fr S&E1# N = 84 ANZ2# N = 105 Spanish2* N = 108 German3*† N = 689 # Measured with echo *Measured with angiography †German registry data includes both patients treated with CoreValve, 84.5%, and EDW Sapien, 15.5% Gerckens, Ulrich, MD. Safety, Durability and Effectiveness at Two Years with the 18 Fr CoreValve Transcatheter Aortic Valve. EuroPCR 2010. Meredith. VARC-adjudicated Outcomes in Inoperable and High Risk AS Patients. TCT 2010, Washington, DC. Avanzas P, Munoz-Garcia AJ, Segura J, et al. Percutaneous implantation of the CoreValve® self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol. 2010;63:141-148. Zahn, et al. Transcatheter Aortic Valve Implantation: First Results from Multi-center Real World Registry. EHJ [epub ahead of print].

Proper Implant Location Results in Less ParaValvular Leak 35 P = 0.09 P = 0.19 P = 0.05 30 P = 0.10 25 20 Good Grade >1 Paravalvular Leak (%) Suboptimal 15 10 5 1 mo 3 mos 6 mos 12 mos N = 326 Proper implant location defined as 4 to 8 mm below annulus. De Carlo. Serial Echocardiographic Evaluation of the CoreValve Aortic Bioprosthesis: Italian Registry EuroPCR 2010.

Vascular Complications 30% 25% 19.5% 20% Percent of Patients (%) 15% 9.5% 10% 7.5% 6.7% 6.5% 5% 3.9% 0% 18 Fr S&E1* N = 125 ANZ2# N = 118 French3† N = 66 German4‡ N = 588 UK5§ N = 460 Italian6|| N = 772 Vascular complication is not defined consistently across studies. *Defined as arteriovenous fistula, bowel ischemia, hematoma, pseudoaneurysm, and retroperitoneal bleed. #Defined using proposed VARC definitions, Serruys EuroPCR 2010. Includes both major (1.9%) and minor complications (4.6%). †Definition unknown. ‡Defined as groin problems, including major and minor. §Defined as major vascular injury or later vascular injury requiring surgery. ||Defined as severe bleeding/surgery of femoral access. Medtronic. Data on file. COR 2006-02: 18 Fr Safety & Efficacy Study Re-Analysis, August 14, 2009 Meredith. VARC-adjudicated Outcomes in Inoperable and High Risk AS Patients. TCT 2010, Washington, DC. Eltchaninoff. French Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Zahn, et al. Transcatheter Aortic Valve Implantation: First Results from Multi-center Real World Registry. EHJ [epub ahead of print. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 16

Pacemaker Implantation Varies Between Studies Procedural variability, anatomical differences and clinical practice variation impact pacemaker implant rates:9,10 Depth of implant may induce conduction disturbances11 Valvuloplasty balloon size may impact conduction system11 Anatomical and patient-related factors may impact conduction disturbances12 Inter-hospital variability due to physician subjectivity, country-based healthcare norms and reimbursement strategies9 New Pacemaker Implants at 30 days Weighted Average 28.5% Weighted Average 28.5% Weighted Average 28.5% 60% 60% 60% 50% 50% 50% 42.5% 42.5% 42.5% 40% 40% 40% 40% 40% 40% 35.2% 35.2% 35.2% 31.3% 31.3% 31.3% Percent of Patients (%) Percent of Patients (%) Percent of Patients (%) 30% 30% 30% 26.9% 26.9% 26.9% 26% 26% 26% 23% 23% 23% 18.5% 18.5% 18.5% 20% 20% 20% 10% 10% 10% 0% 0% 0% 18 Fr S&E1 N = 125 18 Fr S&E1 N = 125 18 Fr S&E1 N = 125 ANZ2 N = 118 ANZ2 N = 118 ANZ2 N = 118 Spain3 N = 108 Spain3 N = 108 Spain3 N = 108 French4 N = 66 French4 N = 66 French4 N = 66 Belgian5 N = 119 Belgian5 N = 119 Belgian5 N = 119 German6 N = 588 German6 N = 588 German6 N = 588 UK7 N = 460 UK7 N = 460 UK7 N = 460 Italian8 N = 772 Italian8 N = 772 Italian8 N = 772 1. Medtronic Data on File. COR 2006-02: 18 Fr Safety& Efficacy Study Re-Analysis, August 14, 2009. 2. Meredith IT. A Snapshot from the Ongoing Australia-New Zealand Medtronic CoreValve® Registry. Transcatheter Cardiovascular Therapeutics 2009, September 21-25, 2009. San Francisco, CA. 3. Avanzas P, Munoz-Garcia AJ, Segura J, et al. Percutaneous implantation of the CoreValve® self-expanding aortic valve prosthesis in patients with severe aortic stenosis: early experience in Spain. Rev Esp Cardiol. 2010;63:141-148. 4. Eltchaninoff. French Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 5. Bosmans. Belgian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 6. German Registry data on file. New pacemakers with Corevalve 240/565. 7. Ludman. UK Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. 8. Petronio. Italian Registry, TAVI Facts, Figures and National Registries. EuroPCR 2010, Paris, France. See Reference slide for sources 1-8 See Reference slide for sources 1-8 See Reference slide for sources 1-8 9. N. Piazza, “AV-Block and Pacemaker Requirements Associated with Medtronic CoreValve TAVI: Incidence, Outcomes and Treatment Strategies”, TCT 2009. 10. Latsios et al. Device Landing Zone” Calcification, Assessed by MSCT, as Predictive Factor for Pacemaker Implantation after TAVI. Catheter Cardiovasc Interv. 2010 [Epub ahead of print]. 11. N. Piazza, “AV-Block and Pacemaker Requirements Associated with Medtronic CoreValve TAVI: Incidence, Outcomes and Treatment Strategies”, TCT 2009. 12. N. Piazza, “Persistent Conduction Abnormalities and Requirments for Pacemaking 6 Months after TAVI”, PCR 2010. 17 17

Medtronic CoreValve® System Subclavian and Direct Aortic Approaches Summary of Clinical Experience UC201104698a_EE1P

Subclavian Access: CoreValve® System Procedure Success Note: Procedure success definition varies among publications 1. Petronio AS. Italian Experience Subclavian vs. Transfemoral. Presented at TCT 2011. 2. Laborde JC. TAVR Access Site Considerations. Presented at TVT 2011. 3. Verkroost MWA. TAVI Using Left Subclavian Route. Presented at TCT 2011. 4. Modine T. TAVI using Axillary/subclavian Access. J Thorac Cardiovasc Surg. 2011; 141(2).

Subclavian Access: CoreValve® System 30D Survival 1. Petronio AS. Italian Experience Subclavian vs. Transfemoral. Presented at TCT 2011. 2. Gilard M. France 2 Registry. Presented at TCT 2011. 3. Blackman D. UK Registry Comparison valve type and access approach. Presented at TCT 2011. 4. Verkroost MWA. TAVI Using Left Subclavian Route. Presented at TCT 2011. 5. Modine T. TAVI using Axillary/subclavian Access. J Thorac Cardiovasc Surg. 2011; 141(2).

Direct Aortic Access: CoreValve® System Dataset A standard dataset was circulated to 19 centres who were believed to have carried out 3 or more cases in their individual centre. A total of 115 cases had been performed in these 19 centres prior to 31/12/11 To date, a completed dataset has been returned from 12 of these centres

Results (N=93) 30 day Mortality In-hospital Stroke 9/93 (9.7%) In-hospital Stroke 3/93 (3.2%) Thoracic Aortic Dissection 0/93 (0%) Life Threatening Bleed (VARC) 4/93 (4.3%) Major Vascular Injury (VARC) Conversion to Full Sternotomy New Permanent Pacemaker 16/93 (17.2%)

CoreValve® US Pivotal Trial Study Design1-3 Extreme Risk Cohort High Risk Cohort CoreValve Observational CoreValve Single Arm SAVR Iliofemoral Access? Up to 100 Randomization 1:1 395a 395 790 487 No Alternative Access Medtronic CoreValve US Pivotal Trial Up to 45 Sites Estimated Enrollment: 1497 Yes Up to 587 aIncludes patients with iliofemoral and alternative access. SAVR=surgical aortic valve replacement. 1. Medtronic CoreValve® U.S. Pivotal Trial. US National Institutes of Health Web site. http://clinicaltrials.gov/ct2/results?term=NCT01240902. Accessed 6/30/11. 2. Medtronic CoreValve® U.S. Pivotal Trial (Extreme Risk Patients). Version 7.0. Mounds View, MN: Medtronic, Inc. Clinical Research; 2011. 3. Medtronic CoreValve® U.S. Pivotal Trial (High Risk Patients). Version 6.0. Mounds View, MN: Medtronic, Inc. Clinical Research; 2011. References: Medtronic CoreValve® U.S. Pivotal Trial. US National Institutes of Health Web site. http://clinicaltrials.gov/ct2/results?term=NCT01240902. Accessed 6/30/11. 2. Medtronic CoreValve® U.S. Pivotal Trial (Extreme Risk Patients). Version 7.0. Mounds View, MN: Medtronic, Inc. Clinical Research; 2011.

Transapical System Approved for Clinical Use in Europe (CE Mark)

Jena Valve Ensures Coronary Flow -low profile Maintains haemodynamics during deployment Feeler guided anatomical positioning Active fixation -Unique Jena Clip Partially retrievable and repositionable

Jena Valve Described as a 2nd generation TAVR device Potential advantages: Feeler guided anatomical positioning Clip fixation on native leaflet Device retrievability CE mark in September 2011

Clinical Research Programme FIH CE Mark Study Post-market Proof of concept Germany (Leipzig) 12 patients enrolled (July 2009 - April 2010) Demonstrate safety and efficacy Germany (7 centres) 73 pts(Nov2010-July2011) FU ongoing Primary endpoint: 30D mortality Evaluation in real world European centres Approx 150 pts

Enrolled N=73 Withdrwan N=6 Procedure Initiated N=67 30 day FU N=66 Withdrawn=1

Symetis Acurate TA System

t

t

t

t

t

Emerging Technologies with Clinical Data

Heart Leaflet Technology

Direct Flow Medical Valve

Medtronic Engager Valve Bovine pericardial valve 3 support arms for fixation at the valve leaflets Nitinol frame for sealing in the LVOT

Sadra-BSC Lotus Valve Locking mechanism Bovine pericardium Nitinol frame Adaptive seal Radial expansion with axial compression

Overview: SJM Portico 23mm Valve St Jude Medical Portico Valve Overview: SJM Portico 23mm Valve General 18F (TF) Nitinol self expanding valve designed to be: Fully re-sheathable* Repositionable* (antegrade and retrograde) at the implant site Retrieveable* Bovine and porcine pericardial valve with Linx™ anti-calcification technology** For annulus range: 19 – 21 mm Cuff tissue and stent geometry designed to minimize PV leak Implanted transfemorally without need for rapid pacing * Until fully deployed ** There is no clinical data currently available that evaluates the long-term impact of anti-calcification tissue treatment in humans.

Access N Procedure success Complication Results Current Status Device Access N Procedure success Complication Results Current Status Heart Leaflet Technology TF 9 N=5 X4 Tamponade Death=3 Devise redesign: animal planned Direct Flow Medical (22F) 31 N=20 X9 not done X2 surgical conversion Death = 2 71% survive at 2 yrs 18F system under evaluation Medtronic Engager TA 10 N=10 X2PPM Mortality=1(at FU) Pivotal study to start Sadra-BSC Lotus (18F) 12 NA Reprise I (S&E) and Reprise II (CE Mark) to start St Jude Portico (18F) None at 30D European CE Mark study started Dec 2011

Conclusions TAVR landscape with self expanding technologies is expanding Standardisation of event reporting (VARC) will allow more transparent comparisons to be made Technological iterations will further enhance the safety and efficacy of this technique Long term durability and outcome awaited