Welcome to the CLU-IN Internet Seminar

Slides:



Advertisements
Similar presentations
COSHH ASSESSMENT TRAINING Essential Elements of a COSHH Form.
Advertisements

WAREHOUSING MANAGEMENT
Module 14: Blood Collection and Handling Dried Blood Spot
Sampling Techniques, Safety, and Sample Quality Control Ohio Department of Transportation Hazardous Materials Training December 5, 2006.
Lessons Learned Multi Incremental Sampling Alaska Forum on the Environment February, 2009 Alaska Department of Environmental Conservation.
Sampling: Your data is only as good as your field technicians.
DBS preparation from finger stick blood in Microtainer®
1 USDOC41 Rev 0 1/04 Training and Education Program ©2004 HemoCue, Inc. HemoCue ® Training and Education Program The HemoCue Hb System.
Presented by: Kyle F. Gross AWAL Laboratory Director
Radiation Safety Training Soil Gauges Washington State University Radiation Safety Office.
Chemicals and Apparatus: Putting the Tools to Work
Resource Conservation and Recovery Act.
NJDEP Beach Monitoring System New Jersey Department of Environmental Protection.
Inorganic Chemicals (IOC) Non-Metals Sampling Procedures.
Oil Spill Sampling.
Rock Coring Obtain undisturbed samples of solid, fractured, or weathered rock formations.
Soil and Rock Sampling. Environmental Site Characterization Number of samples taken depends on the size of the site Hollow stem auger normally used for.
Lab 4: Determination of Aerobic colony count in Foods
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
Safe Drinking Water Act Phase II & V Sampling Procedures: Volatile Organic Compounds (VOCs)
Patient Identification & Specimen Collection How Proper Patient Identification and Proper Specimen Collection Affects the Accuracy of Your Patient’s Laboratory.
Collection and Preservation of Water and Wastewater Samples
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
Presented by Steven P. Feltman Food Safety and Quality Specialist.
Radionuclides Sampling Procedures. The purpose of these slides is to demonstrate recommended sampling techniques. This presentation includes: supplies.
Module 8: Blood Collection and Handling Dried Blood Spot
Measurement of Soil Moisture
WHO - PSM Materials Pharmaceutical Quality, Good manufacturing Practice & Bioequivalence Kiev, Ukraine October 2005 Maija Hietava M.Sci.Pharm Quality.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
1 Welcome to the CLU-IN Internet Seminar Tribal Consultation Informational Webinar - Institutional Controls in Indian Country Sponsored by: U.S. EPA Office.
Automatic pipettes use and calibration
Inorganic Chemicals (IOC) Metals Sampling Procedures.
Testing Liaison Basic Training. Who can be a Testing Liaison? ONE RULE: INSTRUCTORS AND INSTRUCTIONAL AIDES CANNOT BE TESTING LIAISONS OR PROCTORS Typically,
SOIL MECHANICS AND FOUNDATION ENGINEERING-II (CE 311)
Why do I need a Chain of Custody (COC)? Presentation to: KWWOA Department for Environmental Protection Energy & Environment Cabinet To Protect and Enhance.
RECRYSTALLIZATION, MELTING POINT, and HPLC ANALYSIS of ANALGESICS
CASD Mobile Labs.
Water content DEFINITION:
Preparation Stationary Sample Holders
Oral Glucose Tolerance Test
3.03 Understand support services
Automatic Pipettes Use And Calibration
storage and External Transportation
Food Sampling & Preparation of Sample Homogenate
Techniques in Molecular Biology 2017 Fall Lecture -2-
Techniques in Molecular Biology 2017 Fall Lecture -2-
Gel Electrophoresis Teacher Instructions BioRad Set Up 12 groups
World Health Organization
Use and Maintenance of Micro-pipettes
Waste and Contamination
3.03 Understand support services
East Carolina University Compressed Gas Safety Training Program
Introduction To Medical Technology
Lab 4: Determination of Aerobic colony count in Foods
3.03 Understand support services
Factsheet: Proper Permanent Well Abandonment for Virginia Coastal Plain Wells VDH DEQ What is.
Instructions for Wipe Testing for Radioactive Material Contamination
TRENTON Casing Filler Presentation
Marine Biotechnology Lab
Instructor Notes The job of protecting food continues even after it has been prepared and cooked properly, since microorganisms can still contaminate food.
Safety Moments Topic: Handling Waste
This presentation document has been prepared by Vault Intelligence Limited (“Vault") and is intended for off line demonstration, presentation and educational.
3.03 Understand support services
Lab 4: Determination of Aerobic colony count in Foods
3.03 Understand support services
This presentation document has been prepared by Vault Intelligence Limited (“Vault") and is intended for off line demonstration, presentation and educational.
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
3.03 Understand support services
GLUCOSE TESTING USING THE TRUEtrack GLUCOMETER
Presentation transcript:

Welcome to the CLU-IN Internet Seminar ERTP Presents... Soil Sampling and Analysis for Volatile Organic Compounds (VOCs) Sponsored by: EPA Office of Superfund Remediation and Technology Innovation (OSRTI) Delivered: Thursday, September 21, 2017 1 PM EDT (1700 GMT) Instructors: Eric Watt, Geologist, Tetra Tech eric.watt@tetratech.com Moderator: Jean Balent, Environmental Scientist, USEPA Office of Superfund Remediation and Technology Innovation balent.jean@epa.gov Visit the Clean Up Information Network online at www.cluin.org

DISCLAIMER Notice: This presentation has been provided as part of a U DISCLAIMER Notice: This presentation has been provided as part of a U.S. Environmental Protection Agency webinar. The document does not constitute EPA policy. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. Links to non-EPA web sites do not imply any official EPA endorsement of or a responsibility for the opinions, ideas, data, or products presented at those locations or guarantee the validity of the information provided. Links to non-EPA servers are provided solely as a pointer to information that might be useful to EPA staff and the public.

ERTP Presents… Webinars The Environmental Response Training Program (ERTP) will sponsor “ERTP Presents…” on EPA’s Contaminated Site Clean-Up Information (CLU-IN) website (www.clu-in.org). Various topics relevant to EPA staff, and other federal and state partners, will be presented in webinar sessions. Visit http://clu-in.org/live/ for up to date information and to register.

Soil Sampling and Analysis for Volatile Organic Compounds (VOCs) Why? Precise characterization of volatile organic compounds (VOCs) in soil is often critical since decisions for remediation are based on analytical measurement. Unfortunately, the acts of collecting and storing soil can subject soils to numerous variables that can alter VOC concentrations. Volatilization, Biodegradation, Other loss of VOCs in the sample.

Today’s Webinar Topics The collection of high-quality soil samples for VOCs; Best practices for sampling techniques to minimize the loss of VOCs; The advantages and disadvantages of soil sampling devices, such as Encore and TerraCore samplers. EPA ERT SOP #2012 “Soil Sampling”

Good Soil VOC Data Begins with Good Sampling Practices As with all environmental samples, the laboratory data are only as good as the samples collected in the field When it comes to sampling soils for VOCs, everything we do from the time the soil cores are retrieved to the preparation of the sample for shipment can affect VOC recovery and sample quality

Good Soil VOC Data Begins with Good Sampling Practices (continued) Soil samples for VOCs can show significant losses within seconds to minutes of opening soil cores Handling cores and sample preparation methods can contribute to additional losses Using a sampling method that does not maintain VOCs during sample collection, shipment, and during the hold before analysis adds to the problem Do not collect composite or ISM samples for VOCs

Handling of Samples When a Soil Core Liner is Opened Managing sampling from a soil core can be a complex situation - stability of VOCs in the core depends on factors such as: 1. Whether the soil is consolidated (e.g., clay, till) or unconsolidated (e.g., sand, gravel) 2. Time that the core is open or exposed before sampling (off-gassing) 3. Moisture content of the soil 4. Disturbance of integrity of the core 5. Ambient temperature 6. Heat generated by the soil coring method (e.g., sonic drilling)

VOC Loss… Analyte compound list Heavier VOCs are less likely to be lost whereas lighter VOCs will likely be lost. Density of sample material More porous samples (e.g. sand) will be prone to loss of VOCs whereas dense sample material (e.g. clay) would be less prone to loss.

Best Practices When Sampling with Acrylic Soil Core Liners Cap the acrylic liner to preserve VOCs, do not split until ready to sample Split liner as soon as possible – every minute counts! Keep liner on ice if extended times are required Sample immediately with EnCore or field-preserved vials upon opening Screen the core and select samples for analysis; USEPA SW 846 Method 3815 is the current method for screening, although use is not mandatory Soil Sampling and Analysis for VOCs September 21, 2017 10

Best Practices When Sampling with Acrylic Soil Core Liners (continued) Once a core barrel has been opened, the collection of samples is the first activity performed (i.e., pre-empting even the logging of sub-surface core sample recovery and other soil characteristics). Drill rig personnel should adjust their pace accordingly to allow collection of samples.

Things to Avoid When Sampling with Acrylic Soil Core Liners Leaving the liner exposed while screening Sampling from the container used for screening Use of intermediate storage containers (e.g., core barrel liners, plastic bags, large glass jars) to hold soil for extended periods prior to sub-sampling defeats intent and should be avoided. Taking a second boring for samples after screening initial boring - no guarantee samples will match from different locations Using bulk sampling rather than sealed or field-preserved sampling methods

Avoid Using Soil Samplers Without Core Barrel Liners Soil sampling tools used without core barrel liners, such as split spoon samplers, make it nearly impossible to retain VOCs before samples are collected, even using proper sampling methods and procedures. Soil Sampling and Analysis for VOCs September 21, 2017 13

Sample collection, preservation, transportation, and analysis: ASTM Standards and EPA Methods for Soil VOC Sample Collection and Analysis Standards of practice for obtaining, handling, and screening of soil cores: ASTM Standards D6282 and D6640 cover collection and handling of soil cores for environmental sampling Sample collection, preservation, transportation, and analysis: US EPA Method 5035, various state guidance documents ASTM Standard D4547 – Sampling Waste & Soils for VOCs ASTM Standard D6418 – EnCore Sampling for VOCs in Soils

Methods for Sampling Soils for VOC Analysis Bulk sampling method No core liner or brass sleeve liner Sample is scooped or sliced from soil cores and packed in wide-mouth jar without preservation Lab prepares a weighed sub-sample prior to analysis Sub-core samples (~5) collected in field and placed in pre-preserved VOA vials for analysis EnCore® Sampler – sealed chamber, no field preservation required – samplers are shipped to lab for analysis Remember one sample equals three soil plugs either in the Encore or three vials plus a 4 ounce jar for the lab to get a dry weight. Soil Sampling and Analysis for VOCs September 21, 2017 15

Soil Sampling and Analysis for VOCs US EPA Method 5035 Implemented in 1997 to standardize sampling and field preservation and avoid random error and low bias from bulk sampling Incorporates two approved methods of sample collection and preservation: Field preservation of soil core sub-samples using methanol or sodium bisulfate EnCore sealed samplers, with no preservation required Encore™ TerraCore™ Dry Weight Soil Sampling and Analysis for VOCs September 21, 2017 16

High Level and Low Level Methods in 5035 Samples are preserved in methanol for “high level” analysis Calibration range increases to 200 μg/kg with only a 5 gram sample. Samples are preserved in sodium bisulfate for “low level” analysis Method Detection Limits down to 0.5 μg/Kg and concentrations < 200 μg/Kg Field preservation is typically done at a 1:1 ratio (weight/volume) of soil and preservative Pre-preserved vials supplied by the laboratory are weighed to allow calculation of soil sample weight – careful not to add additional label! Soil samples are based on volume and weigh approximately 5, 10, or 25 grams based on sample type Hold time for samples is 14 days when chilled @ 4 oC

Why are there two preservatives used in Method 5035 samples? Some programs have detection limit requirements for some analytes (e.g., benzene) that are lower than most labs can achieve with a 50:1 dilution of methanol in water On the other end of the spectrum, samples with VOC concentrations above 200 μg/kg can’t be accurately quantified in a sodium bisulfate solution Unless you know that all of your samples will fall above or below the 200 μg/kg threshold, both samples are taken in the field. The lab will screen the samples to determine which to analyze.

Collecting Samples for Field Preservation with Methanol Safety Note! Methanol is a toxic and flammable liquid. It must be handled with all required safety precautions related to toxic and flammable liquids. Methanol must be handled in a ventilated area. Use protective gloves when handling the methanol vials. Store methanol away from sources of ignition such as extreme heat or open flames. Using a Terra Core sampler, place a 5 gram plug of soil into pre-preserved vial containing methanol 1:1 or greater weight/volume ratio of soil to methanol Operation must be done quickly to prevent VOC loss Tared weight of methanol vials should be verified before samples are collected The vials are pre-preserved, pre-labeled, and pre-weighed when they come from the laboratory. Special care should be exercised to ensure that no additional labels or custody seals are used on the vials. This is because the adhesives used on these other labels and seals have been known to affect the analytical results. Also, the laboratory has recorded the tare weight of the vial with their label and preservative; the laboratory will be unable to calculate the exact amount of soil added to the vial if additional labels or seals are attached. With the Terra Core™ plunger seated in the handle, push the Terra Core™ into the freshly exposed soil until the sample chamber is filled. A full chamber will contain approximately 5 grams of soil. Scrape excess soil off of the Terra Core™. Rotate the plunger 90○ so that it is perpendicular to the handle. Place the sampler at the top of the vial and push the plunger to expel the soil into the vial. Wipe excess soil from the vial threads and cap to insure a good seal. Swirl the preservative in the vial to make sure the preservative covers the top of the soil. Fill out labels fixed to the jar and place in a cooler with ice. Do not label the VOA vial with additional labels. Repeat this process for the remaining two 40 mL VOA vials. Using the Terra Core™ or a clean spoon or trowel, fill the percent moisture jar. Label the percent moisture jar and place it in the cooler. Dispose of the used Terra Core™. Soil Sampling and Analysis for VOCs September 21, 2017 19

Collecting Samples for Field Preservation with Sodium Bisulfate Using a Terra Core sampler, place 5 gram plug of soil into pre-preserved vial containing 20% sodium bisulfate aqueous solution Calcareous soil types should be checked for effervescence prior to sampling or vial may explode! 1:1 or greater weight/volume soil/preservative ratio Two vials are collected (plus a MeOH preserved vial) Collect an additional 3 vials for an MS/MSD Tared weight of pre-preserved vials should be verified before samples are collected Test calcerous soil by adding a few drops of solution to some sample in a clean vial. If it bubbles, its not suitable.

Advantages of Field Preservation No further preparation of the sample is required in the laboratory prior to analysis Widely accepted by regulators VOC concentrations remain stable throughout the hold time and beyond Laboratory doesn’t require any special tools or procedures to process sample

Disadvantages of Field Preservation Vial seals can leak/break More experienced field staff required Difficult under adverse weather conditions More risk of error, e.g., spillage, mixing/adding labels, etc. Vehicle exhaust fumes can contaminate methanol Shipping restrictions may apply for methanol (not typically an issue if labeled as “laboratory samples” and volume is less than 500 mL)

Disadvantages of Field Preservation (continued) Shipped samples shall conform to all U.S. Department of Transportation (DOT) rules of shipment found in Title 49 of the Code of Federal Regulations (49 CFR parts 171 to 179), and/or International Air Transportation Association (IATA) hazardous materials shipping requirements found in the current edition of IATA’s Dangerous Goods Regulations.

EnCore® Sampler – Alternative to Field Preservation The only commercially available sampler listed in Method 5035 Meets ASTM D4547 requirements for VOC retention during permitted hold time 5 and 25 gram sizes Designed to collect an average weight ̶ exact weight is determined in lab Zero headspace design ̶ minimal air trapped in the sample Multiple suppliers – QEC, Forestry Suppliers, En Novative EnCore® Sampler and sampling handle Soil Sampling and Analysis for VOCs September 21, 2017 24

Depress the lever on the T-handle and push the coring body into the T-handle’s open end. When fully inserted, rotate the coring body clockwise to lock it in place. The device will make a clicking noise as it locks. The assembled device is now ready for use.

Press the T-handle into the freshly exposed surface, forcing soil into the sampler. As the cavity fills with soil, the plunger is forced upward. Soft soil may require several plunges and may need to be pressed against a hard surface to ensure that headspace is eliminated. When full, the O-ring at the top of the coring body will be visible in the middle of the viewing port on the T-handle.

Using a paper tower, remove excess soil from the sides of the sampler Using a paper tower, remove excess soil from the sides of the sampler. Be careful not to remove any soil from the opening of the coring body. Leaving the soil level at or very slightly above the rim of the sampler will ensure that void space in the sample is minimized.

Observe the ridge on the coring body and the arms of the cap Observe the ridge on the coring body and the arms of the cap. Push the cap onto the coring body so that the arms of the cap go through the flat spaces. Give the cap a quarter turn, locking it in place. Check to be sure that the groove of each arm is hooked over the ridge of the coring body and that the cap is locked. Remove the capped sampler by depressing the locking lever on the T-handle while twisting and pulling on the coring body. Finish locking the capped sampler by rotating the plunger rod counter-clockwise as far as it will go. The slot located on one arm of the T-handle can facilitate this action.

Label the En Core™ envelope with the required sample information Label the En Core™ envelope with the required sample information. Return the full En Core™ to its zipper bag, seal, and store in a cooler at or below 4°C. Repeat steps 1 through 9 for two more En Cores™ to complete the set of three for the sample. Fill the 2 oz. jar for moisture content and store in a cooler. Decontaminate the En Core™ T-handle or switch it out with a clean one between collecting separate samples.

Collecting a Surface Soil Sample Expose the soil to be sampled by scraping the surface with a clean spatula or spoon. Push the device into the soil until the sample chamber is full and then extract the device

Advantages of the EnCore® Sampler Can be faster – less field time needed / more sample throughput Easy to use, minimal training No handling of preservative in the field No shipping restrictions Sample is preserved later in controlled laboratory Setting, avoids random error from field preservation Long shelf life ̶ essentially no expiration Ships in a proprietary VOC-proof bag

Disadvantages of the EnCore® Sampler Samples must be preserved at lab within 48-hour hold time stated in Method 5035, however, if EnCore sampler is used for other programs: ASTM D4547 describe extending hold time up to 14 days by freezing samples to -12 ± 5C ASTM D6418 describes extending hold time up to 14 days by freezing samples at -7 to -21C, or holding for 48 hours at 4 ±2C followed by storage at -7 to -21C for up to five days Coordinate with lab if Saturday delivery expected Samples are reported in dry weight, so a small jar of soil should be always collected to measure soil moisture Most agree that per-sample cost is higher than field preservation Some offset by time savings, especially for inexperienced staff Lab may charge a sample prep fee

Decisions, Decisions

Decisions, Decisions, (continued) Sampling intervals must be decided as quickly (and safely) as possible If using Terra Cores®, discuss preservatives with laboratory ahead of time If using EnCores®, samples must be shipped to the laboratory or picked up via courier the day collected