Observation of Failure Modes of RF Amplifiers at ATLAS

Slides:



Advertisements
Similar presentations
RFQ Tuning and RFQ Control Status
Advertisements

RF Specification discussion MICE RF workshop 16 th April 2012.
IOT Measurements & Amplifier Improvements at Diamond
Tom Powers Practical Aspects of SRF Cavity Testing and Operations SRF Workshop 2011 Tutorial Session.
CW RF System for the ATLAS Efficiency and Beam Intensity Upgrade Speaker: Yong Luo, Physics Division, ANL On Behalf of: Sergey Sharamentov, Peter Ostroumov,
Andrew Moss ASTeC MICE Project Board 28 th June 2011 MICE RF System.
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
MICE Refurbishment of CERN RF equipment for MICE M. Vretenar, CERN AB/RF.
1 Operating Experience and Reliability Update on the 5 kW CW Klystrons at Jefferson Lab Richard Walker & Richard Nelson Jefferson Lab, Newport News VA.
RF systems for MICE Andrew Moss The MICE RF Group and the TIARA WP7 Team Contributions include Daresbury, RAL, CERN, LBNL, LANL, FNAL, Strathclyde & Sheffield.
ANL HWR Cryomodule Status Update 27 January 2015 Zachary Conway On behalf of the ANL Linac Development Group Argonne National Laboratory Physics Division.
Cell-Coupled Drift Tube Linac M. Pasini, CERN AB-RF LINAC4 Machine Advisory Committee 1 st meeting CERN January 29-30, 2008.
Proton Source Workshop December 7 & 8, 2010 John Reid December 8, 2010.
ATLAS Intensity and Efficiency Upgrade ATLAS USERS MEETING Speaker: Mike Kelly Physics Division May 15, 2014.
RF power & FPC status Eric Montesinos, CERN BE-RF on behalf of all people involved, great thanks to all of them !
Technical aspects of the ATLAS efficiency & intensity upgrade Peter N. Ostroumov ATLAS Users Workshop, August 8-9, 2009.
Preliminary design of SPPC RF system Jianping DAI 2015/09/11 The CEPC-SppC Study Group Meeting, Sept. 11~12, IHEP.
High Power RF Systems, Control and Distribution in the HINS Alfred Moretti, Brian Chase, Chris Jensen and Peter Prieto Fermilab Accelerator Advisory Committee.
F.E.T.S. RFQ Mechanical Design by Peter Savage 7 th January 2010.
July LEReC Review July 2014 Low Energy RHIC electron Cooling Sergey Belomestnykh SRF and RF systems.
Andrew Moss ASTeC CM32 9t h February 2012 RAL MICE RF System.
Anders Sunesson RF Group ESS Accelerator Division
Ding Sun and David Wildman Fermilab Accelerator Advisory Committee
Solid State RF High Power Amplifier Developments at SOLEIL Ti RUAN, on behalf of SOLEIL RF Group CWRF10 CELLS-ALBA Barcelona Spain May
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
Design Optimization of MEIC Ion Linac & Pre-Booster B. Mustapha, Z. Conway, B. Erdelyi and P. Ostroumov ANL & NIU MEIC Collaboration Meeting JLab, October.
R.SREEDHARAN  SOLEIL main parameters  Booster and storage ring low level RF system  New digital Booster LLRF system under development  Digital LLRF.
704 MHz warm cavity November 4, 2015 A.Zaltsman: SRF & warm RF components for LEReC1  A single cell 704 MHz warm cavity is used to correct the beam energy.
ALBA RF Amplifiers based on IOTs CWRF08 - CERN, March 2008 Michel Langlois & Paco Sanchez 1 Michel Langlois & Paco Sanchez.
Comparison of Fermilab Proton Driver to Suggested Energy Amplifier Linac Bob Webber April 13, 2007.
Warm and Cold Ion Linac: Comparison and Optimization March 30, 2015.
Andrew Moss ASTeC TIARA Mid term meeting 12 th 14 th June 2012 CIEMAT ICTF Progress on the MICE RF System.
Performance analysis of cryogenic system and cryomodules for the complete superconducting linear accelerator at IUAC, New Delhi. T S Datta ( On behalf.
Cryostat & LHC Tunnel Slava Yakovlev on behalf of the FNAL team: Nikolay Solyak, Tom Peterson, Ivan Gonin, and Timergali Khabibouline The 6 th LHC-CC webex.
Laboratoire commun CEA/DSM - CNRS/IN2P3 M. Di Giacomo – CWRF10 1 CWRF th of Mai Barcelona SPIRAL 2 RF SYSTEMS Status report Marco DI GIACOMO.
CW and High Average Power Workshop BNL The Diamond Storage Ring IOT based High Power Amplifier Morten Jensen on behalf of the SR RF Group.
Practical experience with the AD Stochastic Cooling Murphy’s Law R. Louwerse.
650 MHz Solid State RF Power development at RRCAT
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
Project X High Power 325 MHz RF Distribution and Control Alfred Moretti, Nov 12, 2007 Project X Workshop.
Status of Vertical Test Stand at RRCAT P Shrivastava, P Mohania,D.Baxy, Vikas Rajput S C Joshi, S Raghavendra,S K Suhane RRCAT, Indore November 26, 2012.
PIP Update May Agenda Summary Update – Activities – Budget – Plans Update Slides – Solid StateTom – ModulatorsRene – High Power Ferrite Testing.
RFQ coupler S. Kazakov 07/28/2015. Requirements: Coupler requirements Expected problems: Heating (loop, ceramic window, etc.) Multipactor Solutions: Appropriate.
K. TAVAKOLI Upgrade of the superconducting RF cavities at soleil K. Tavakoli SOLEIL Synchrotron, France.
SRF Advances for ATLAS and Other 
A CW Linac scheme for CLIC drive beam acceleration. Hao Zha, Alexej Grudiev 07/06/2016.
DESIGN STUDY November 28 th - 30 th 2005First EURISOL Design Study TOWN MEETING High Power RF Amplifiers Development at LNL Fabio Scarpa - INFN LNL.
Operation Status of the RF Systems and Taiwan Photon Source
Guillaume Olry on behalf the IPN Orsay SPIRAL2 team TTC Meeting – Milan, 28 Feb-3 March 2011.
HIE ISOLDE Linac Short Technical Description W. Venturini Delsolaro Material from: L. Alberty, J. Bauche, Y. Leclerq, R. Mompo, D. Valuch, D. Voulot, P.
Areal RF Station A. Vardanyan
Solid State Amplifier Development at PSI
Test of the dressed spoke cavity
High Energy Proton Synchrotrons
XFEL beamline loads and HOM coupler for CW
TTC Topical Workshop - CW SRF, Cornell 12th – 14th June 2013
Tuner system Zhenghui MI 2017/01/17
Developments of High CW RF Power Solid State Amplifiers at SOLEIL
BE/RF-IS Contribution to LIU C. Rossi and M. Paoluzzi
Test plan of ESS HB elliptical cavity
Jefferson Lab Low Level RF Controls
Operation experience of cryogenic system and cryomodules for the superconducting linear accelerator at IUAC, New Delhi. T S Datta ( On behalf of Cryogenics.
Tuner system for CEPC MI Zhenghui 2016/09/14
CEPC RF Power Sources System
Pulsed Ion Linac for EIC
First High Power Test of the ESS Double Spoke Cavity package
Physics Design on Injector I
LEBT water cooling system
RF introduction Anders Sunesson RF group leader
Presentation transcript:

Observation of Failure Modes of RF Amplifiers at ATLAS Speaker: Yong Luo, Physics Division, ANL On Behalf of: Sergey Sharamentov, Peter Ostroumov, Gary Zinkann Matt Hendricks Ninth CW and High Average Power RF Workshop, June 20-24,2016 Grenoble, France

Content Introduction to ATLAS Recent Efficiency and Intensity Upgrade RF System and Failure Modes Improvement Summary and Future Plan

The Present ATLAS Accelerator Cryomodules 8 Cryomodules, 47 SC Accelerating Cavities 109 MHz Energy Upgrade cryomodule 2009 5. 109 MHz Module CARIBU 5. EBIS, 2016 2. 1. 3. 4. Split-ring cryomodules 2012 1. 60 MHz RFQ 2. PII Cryomodules 1992 2013 3. 72 MHz Module

ATLAS Efficiency and Intensity Upgrade Increase beam transmission efficiency Radioactive beams from CARIBU (from Proton to Uranium) Increase intensity of ion beams Stable ion beams up to 10 pµA, hundreds of electrical microAmps This upgrade requires new RF system Two 60 KW amplifiers for 60 MHz RFQ Seven 4 KW solid state amplifiers for New 72 MHz Cryomodule New control system

60.625MHz RFQ and Water Pumps Installed in 2012. In operation since January 2013 Pump Skid RFQ RFQ with water cooling for body and vanes. Fine frequency tuning by adjusting water temp.

60KW Amplifiers to Provide Power for RFQ LLRF Contrl Units. PLC Water CTRL GUI 3 1/8” Coax Line. Two 60KW Amplifiers made by Amplifier Systems. Typically, both are used in operation. But with the adjustment of coupling ports, one amplifier can be used to provide power.

ATLAS CW RFQ Total voltage is 2.1 MV Novel multi-segment split-coax structure Internal size is 19” only for 60 MHz Strongly coupled segments Reduced number of tuners Bead pull measurements are not required Cooling system is optimized to reduce temperature gradients 3-axis deep hole drilling

Simplified Block Diagram of 60KW Amplifier SPEC: 60 KW, 80 dB minimum gain, 60+-1 Mhz nomial + +

SEL – Driven Mode System -allows for driven mode, SEL frequency and phase lock mode and Auto -SEL frequency lock mode for RF power fill-in, driven for acceleration in Auto

Summing Two RF Amplifiers for ATLAS RFQ -two individual phase stabilization loops -I&Q modulator used as 360 degrees phase shifter and fast amplitude regulator

LLRF Control for ATLAS RFQ Channel 1 only, channel B only or both channels switch

Cryomodule of 7 QWRs and 4 SC Solenoids Seven b = 0.077, 72.75 MHz quarter-wave cavities Four 9-Tesla superconducting solenoids Replaces 3 old cryomodules with split-ring cavities Total design voltage is 17.5 MV, 4.5K cryogenic load is 70 W Will be operated to provide ~20 MV, 4.5K cryogenic load is 85 W 5.2 m long x 2.9 m high x 1.1 m wide Vacuum Vessel Room Temperature Magnetic Shield Aluminum Heat Shield (MLI not shown) Compact design, focusing period Includes 2 cavities and 1 solenoid

Summary of Performance for New Cryomodules G-Tank Beta=0.077 Beta=0.15 Comment Number of Cavities 7 Number of Solenoids 4 1 Operating Temperature 4.5 K Voltage per Cavity in Cryomodule >2.5 (4.1) MV >2.0 (3.0) MV Cavity limit in parentheses Performance Limiting System ? VCX fast tuner EPEAK in Cryomodule 40 (70) MV/m 26 (39) MV/m BPEAK in Cryomodule 57 (100) mT 47 (69) mT Power to Helium/Cavity 5 W @2.5 MV 8 W @ 2 MV Stored Energy @1MV/m of the new Cryomodule: 0.15 J

New 72.75 MHz Booster A SC Cryomodule 5.2 m long x 2.9 m high x 1.1 m wide 1 Right Bottom: 5 kW Circulator and Dummy Load with Water Cooling. Left: Cryomodule A Right Upper: RF Coupling Port

New 72.75 MHz Resonator RF System Bellows expand outward Beam ports pull inward Helium pressure form 0 to 90 psi Over-coupling is a main feature for phase lock Transmission through the Cryomodule is almost 100%

Power Supply, Amplifier and LLRF Control Unit 1 Slow Tuner control is integrated into LLRF controller Contains two phase detectors, frequency detector, three phase shifters and two RF limiters Provides regulation of resonator phase and amplitude Provides RF power interlock resonator temperature and circulator cooling water for ARIS Model: TOMCO BT4K-Alpha SPEC: 4 KW, 3 Phase AC 208V, 72.75+-1 Mhz nomial. Use LDMOS

Corrosion of Brass Fittings Original fittings inside the amplifier were brass fittings. They are vulnerable to DI cooling water and corrosion happened. * Deionized (DI) Water causes corrosion of Brass fittings Most likely net chemical reactions: Cu + H2O -> CuO + 2 Hads (or Cu2O + 2 Hads) 2 Hads -> H2 H2 + ½ O2 -> H2O Fix: 1. Replaced all brass fittings with stainless steel fittings 2. Separate the cooling water for RFQ (normal water)and the Amplifier System Lesson: Use stainless steel fittings at Design stage if using DI water!

Replacement of Brass Fittings All copper fittings (Driver, Final stages and flow meters, etc.) were replaced with stainless steel fitting in and out. The fittings to the tube is modified for good mating.

Final Stage Vacuum Tubes Failure The big vacuum tube YC-311 failure Socket failure Tube failure Sometimes both Non-uniform burning marks.

Other Failures (Less Frequently) The driver stage vacuum tube YC-275 failure Broken Inductor due to resonance

Tube Failure Reduction Retaining ring for filament socket Replace damaged sockets with new sockets One trick: You may noticed that the non-uniform discoloration on the sockets. So check the tube position after putting the whole assembly into position. This way to avoid the position shift of the tube. If position is not up right, the contact between the tube and the socket may not be Good! Somewhere may conduct higher current than other area. Added 50KW circulator and interlock circuitry to protect the system and reduce the reflected power to the amplifier. The majority damage of the final stage tube is due to the high reflected power when without circulator presented. Of cause, when using the copper fittings, the corrosion inside the tube degraded the performance of the tube and cooling effects of the water. It make the contribution to the tube failure. New inductor with modified value to avoid resonance. Better insulator for output capacitors: better isolation PID loop parameters optimization New powerful fans inside the amplifier for better cooling

Other Improvement 1 Fuse change and addition (fast blow, lower cost) Board via modification (for High I) HV rectifier wiring was replaced with HV wires Driver tube filament transformer AC connector replacement

50KW Circulator Circulator Dummy load Directional coupler Flow meter with interlock Interlock with reflected power long pulse protection.

Cooling fan Other Improvement 2 Built amplifier system room to alleviate the effects of environment (moisture, dusk, temperature, etc.) Protection for front panel meters: TVS instead of regular diodes Inside connectors (ongoing)

Other Improvement 3 RF power coupling port should be checked and/or replaced if high reflected power is constantly observed.

72MHz 4KW Solid State Amplifier Brass Fitting Corrosion due to DI water. Changed the cooling water to normal water later. Discoloration due to copper corrosion.

72MHz 4KW Solid State Amplifier RF Detector Failure (One Amp.): Used new detector (not Failure) Sensitive overdrive protection threshold (One Amp.): Adjusted the threshold 5V auxiliary power supply diode failure (one Amp.): Used external power supply One Module: LED failure.

Summary Numerous Amplifier Failure Modes have been observed and studied Solid State Amplifiers show satisfied high reliability Improvement has been made over the time and much better reliability has been achieved Future Plan: RFQ Amplifier System: Add Circulator/Dummy load between Driver and Final Stages RFQ Amplifier System: Pulse Study and Better Protection RFQ Amplifier System: Better interconnect wires and connectors for higher current Solid State Amplifier: change the diode in Auxiliary Power Supply Circuitry Others

End