ARMA Update on FM Approvals and FM Global Data Sheets

Slides:



Advertisements
Similar presentations
CODE OF PRACTICE FOR BUILDINGS
Advertisements

Chapter 16 Roofing. First line of defense against the weather Precipitation (Rain, snow) Sun Thermal Transmission Subjected to extreme heat and cold Surface.
David Amori, PE, RRC.  Description  Using negative pressure to simulate and test resistance to wind induced uplift on a membrane roof system.
Above Ground Storage Tanks &
“Do not take anyone’s advice as to how this building should be assembled.”
Building Enclosure Moisture Management Institute (BEMMI)
Foundations of Real Estate Management
FCIA CODE EFFORTS FCIA Spring Conference 2003 By William E. Koffel, P.E. Koffel Associates, Inc.
Thermal Analysis of a 1 Hour Fire Resistive Joint Design for Architectural Expansion Joints Preliminary Final Report Jason Shaw.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
J157 Today’s Presentation: Codes & Approvals. J157 RPM Building Solutions Group is a Registered Provider with The American Institute of Architects Continuing.
FM GLOBAL 1-52 ASTM E 907 SIMULATING WIND UPLIFT PRESSURE TO VERIFY RESISTANCE OF LOW-SLOPE MEMBRANE ROOFS.
Emerging Standards and their effect on Exterior Continuous Insulation in Commercial Wall Construction.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
GA Tech Safety and Health Consultation Program FALL PROTECTION.
Waterproofing System Waterproofing System Roof Garden.
CTC 422 Design of Steel Structures
EXTENSIVE ROOF SYSTEMS
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
ePermitting Roofing System Boris Sursky LEED AP BD + C
MAINTENANCE PART 2. Inlet free of obstructions Inlet free of obstructions Adequate scour protection provided.
The sand filter has to be moved from this location. The embankment cross section used in the slope stability analysis did not include the sand filter.
Appendices Subpart R Steel Erection
Architectural Design Construction of a Wall Section Upon completion of this assignment, you will be able to accurately and neatly draw, to scale and limits,
Unit 2 Terms & Definitions.  Legal requirements designed to protect the public by providing guidelines for structural, electrical, plumbing, and mechanical.
Seasonal High Tunnel Systems for Crops Interim Standard 798 Technical and Program Guidance National bulletin: National Bulletin: Idaho.
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
Choose a category. You will be given the answer. You must give the correct question. Click to begin.
Chapter 4 Lesson Goal After completing this lesson, the student shall be able to understand the effects of fire on common building materials and be able.
New Heat Mitigation and Water Retention Concepts to Expand Green Roofing Demand Greening Rooftops for Sustainable Communities June 4, 2009 Atlanta, GA.
Reinsurance Group of America (RGA) Global Headquarters Natasha Beck Structural Option Faculty Advisor: Heather Sustersic Images courtesy of Gensler & Tom.
Engineering Analysis of NFPA 285 Tested Assemblies
Site Work.
Oklahoma University Children’s Medical Office Building Oklahoma City, Oklahoma AE Senior Thesis Final Report April 14, 2014 Jonathan Ebersole Structural.
Roof Terms Span –Distance across the building. Roof Terms Run –1/2 the distance across the building (1/2 span distance)
Seasonal High Tunnel Systems for Crops Update on interim standard 798 Technical and Program guidance National bulletin: National Bulletin:
Fire Resistance of the Load Bearing Structure of High Bay and Instrument Halls Fire and Egress Safety Analysis of the Instrument Halls Björn Yndemark WSP.
EternaTile Roofing Systems Taking High Performance to A New level.
Sprinkler Loads on Trusses
Fire Resistance Rated Truss Assemblies Educational Overview.
ARMA Spring Committees Steep-Slope Committee March 25, 2009 Codes Steering Group Report Aaron R. Phillips, CSG Chair Staff: Michael Fischer ARMA Consultant:
Sprinkler Loads on Trusses Educational Presentation.
Unit 6: Building Technology in Construction Learning Outcome Understand the techniques used in the construction of superstructures for low-rise domestic.
Overdriven Nails in Structural Sheathings Overview.
Structural Loads.
Building Construction
TPO Competitive Test Programs
FRT Lumber Use in Type III-A Buildings
The Elastizell Advantage For Quality Low Density
LEVEL 4 Air Pressure Testing
APQP Five Phase Process
Commercial Roof Systems
Structural Fire Engineering, October 2015, Dubrovnik, Croatia
Prepared by John R. Henry, P.E. Senior Staff Engineer
Essentials of Fire Fighting Chapter 4 — Building Construction
ICC Code Issues August 2005 D.L. Roodvoets.
Commercial Roof Systems
NFPA 600, INDUSTRIAL FIRE BRIGADE Module : 11 BUILDING CONSTRUCTION.
Educational Overview Revised 6/13/2017
Wood Structures Topic 8 Quality Workmanship
Personal Protective Equipment
Prepared for Municipal Officials in the Prairie Provinces March 2018
IEEE P650 Status Chair Dennis Dellinger Ametek Solidstate Controls
ePermitting Roofing System
From AS :   Part 4— Commissioning, operation and asset management
Fabric Air Dispersion Systems
REVISION REVISION & EXAM PREPARATION 3 CLADDING 1.
Module 4: Technical Requirements for Prefabricated Buildings – Alberta
Water-Resistive Barriers: Assuring Consistent Assembly Water Penetration Resistance Educational Overview Revised August 31, 2018.
Above Grade ICF Walls Interim Summary - Details & Water Management Strategies Building Green With Concrete October 22, 2015 Presented by Brian Hubbs, P.
Presentation transcript:

ARMA Update on FM Approvals and FM Global Data Sheets Phillip Smith, PE AVP - Technical Team Manager FM Approvals

Discussion Topics New/Revised Approval Standards 4470 PV Standard Vegetative Roof Standard DS 1-52 Revisions

Approval Standard 4470 Revision Evolutionary, not revolutionary ARMA included in comment phase Same required ratings With limitations on deck stress Some new optional ratings Noncombustible core insulation Dynamic puncture resistance

New title Approval Standard for Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Systems for use in Class 1 and noncombustible Roof Deck Construction Incorporates Standard 4450 requirements Plan is to eliminate 4450

Retest of Failed Assemblies Following a test failure, a re-test of an identical or similar assembly shall be at the discretion of FM Approvals and with a technical justification of the conditions or reasons for the failure. When a test specimen fails to meet the Approval acceptance criteria for a given classification/rating, two successful test specimens of the same or similar construction must meet the Approval acceptance criteria to qualify for the given classification/rating.

Steel Deck Stress Following testing, stresses induced to steel roof decking shall be determined by rational analysis and shall not exceed the allowable stresses per the latest edition of the American Iron and Steel Institute Cold-Formed Steel Design Manual. These calculations will be conducted on assemblies which introduce highest stress and ratings reduced if needed

Noncombustible core (optional rating) Per ASTM D482 - minimum content of 90% ash. Per ASTM E2058 - visible flaming of the insulation core shall not occur during the entire test. Per ISO 1716:2002 - the insulation core shall have a maximum heat of combustion of 2.0 kJ/g (860 BTU/lb) Same as 4880 requirements

Dynamic Puncture Resistance (optional rating) The Energy Rating for the Dynamic Puncture Resistance Rating shall be the maximum energy attained for which three successive test specimens do not puncture when tested in accordance with ASTM D5635, Standard Test Method for Dynamic Puncture Resistance of Roofing Membrane Specimens. DS 1-29 will be revised to include recommendations on use. Currently only a prescriptive rec. is included in DS 1-29

Corrosion resistance Second method now available Can now be met via CPD test in addition to DIN test

Questions on 4470?

Flexible Photovoltaic Modules

Rigid Photovoltaic Modules

Approval Standard 4476 (Draft, 2009) Flexible Photovoltaic Modules A Standard for rigid is also planned Adhered to or mechanically fastened through an FM Approved roof cover assembly Wind Uplift Resistance 12 x 24 ft Simulated Wind Uplift Pressure Test 2 x 2 ft Simulated Wind Uplift Pull Test Minimum Class 1-60

Approval Standard 4476 (Draft February 2009) Hail Damage Resistance Test Method Measure electrical output pre-test Subject specimen to hail test Measure electrical output post-test Minimum Class 1-MH Combustibility from Above the Roof Deck ASTM E108 Fire Test of Roof Coverings Spread of Flame: Class A, B, C

Questions on PV?

Garden/Vegetative Roofs Vegetative or Garden Roofs Extensive – Up to 6 in. of growing media Semi-intensive – 6-8 in. of growing media Intensive – over 8 in.

Garden/Vegetative Roofs Several layers make up system Layers of insulation, waterproofing, protection, drainage, filters, water retention, growing media and vegetation Some designs use mats or trays in systems which may interlock Use of gravel or paving stones at walkways and border zones

Design Issues Increased dead load requirements Unknown fire risk of dried and dead vegetation Unknown internal fire risk Wind uplift resistance of vegetation Growing media becoming wind-borne debris

Current Standards FLL (Forschungsgesellschaft Landschaftsentwicklung Landschaftsbau) – German guideline widely recognized as the premier design standard Little attention is paid to loss or risk prevention SPRI – Fire Design Standard for Vegetative Roofs Fairly limited in scope, still in review stages Fire design recommendations limited to the use of fire protection and border zones Incorporates many DS 1-35 recommendations FM Global Data Sheet 1-35

FM Global 1-35 Design Recommendations Roof assembly under vegetative system is FM Approved Use of engineered growth media as opposed to soil Minimum of 60% coverage with succulent plants such as Sedums Use of walkways and border zones as fire breaks Exposed membrane needs to be resistant to hail damage Class 1 internal fire rating of roof system

FM Global 1-35 Key Points Assembly under veg. roof must be FM Approved and installed per DS 1-28 and 1-29 Exposed membrane needs to be hail resistant Parapets: Minimum 6 in.above vegetation Minimum 30 in.for building heights greater than 150 ft. Conservative recommendations for gravity and load calculations Dead loads include roof assembly at fully saturated conditions and including additional environmental loads such as snow or ice Design dead load of growth media at a minimum 100 lb/ft3 In addition, increase specified depth of growth media by 15% to account for future growth of system Seismic Loads Design around fully saturated conditions

FM Global 1-35 Limitations Restricted from geographical locations where basic wind speed (3 second gust) does not exceed 100 mph, as determined by FM Global Data Sheet 1-28 Due to the variables in vegetative systems, no classification of exterior fire exposure is made Enter: the need for a complete FM Approvals Standard to address vegetative roof assemblies FM Approvals Standard 4477 – Vegetative Roof Systems

FM Approvals Standard 4477 (Plan) The roof system below the vegetative system shall meet FM Approvals Standard 4470 The roof system shall be installed per FM Global Data Sheets 1-28, 1-29 and 1-35 recommendations

FM Approvals Standard 4477 (Plan) In Addition: Internal fire classifications shall be determined by Calorimeter testing of the entire roof assembly External fire classifications shall be determined by ASTM E-108 testing of the vegetation and growth media Conditions of the vegetation, in terms of coverage and moisture content are to be determined Wind uplift classifications will be determined by the FM Approved roof assembly below the vegetative assembly. The vegetative roof assembly will be installed per FM Global Data Sheet guidelines for ballast (Data Sheet 1-29) Roof Membrane under vegetative system shall meet, foot traffic damage and leakage requirements of FM Approvals Standard 4470

Data Sheet 1-52 Changes March, 2009

DS 1-52 No longer recommended for mechanically attached covers except nailed base sheets to LWIC

Interpreting Test Results If all test results indicate that all measured deflections are within the maximum recommended in this data sheet, the roof is acceptable from a wind uplift performance perspective. Areas where measured deflections exceed the maximum recommended are suspect Test cut down to the deck to determine if failure did occur. If no failure is evident, the roof is acceptable for wind uplift performance. IE - Deflection alone is not a termination of failure If failure is verified from a roof cut, the roof area tested does not pass the test…

DS 1-52 Advanced copy will be made available as soon as accepted and final draft complete

RoofNav Use http://roofnav.com to register and take training Training has been updated to V3.0 Second “quick steps” guide of search tips planned Please report discrepancies/errors to your engineer or the RoofNav Service Deck through the support link