Dimmer 6fold 10V Actuator M/DA6.10.1.

Slides:



Advertisements
Similar presentations
Linking A quick overview of how to configure PulseWorx UPB devices to control each other.
Advertisements

InnoSys Process Sequence. End Effector Components End Effector Prox Switch Load Cell Wire Conduit Crows Foot Nut Runner.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
How to use Touch Screen SeneS Technology. Co, Ltd.
Chapter 10 Advanced Programming, PLC Interfacing, and Troubleshooting
SMS Module Model : SB-DN-SMS/IP Configuration of SMS Module.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
DMX Controller SB-DN-512DMX.
DMX 3CH 650mA LED Driver wiring diagram DMX IN DMX OUT
Service Section Technical Training December 2005.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
HDL KNX System Introduction
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
Buspro Wireless Last update: April 10, HDL-MCIP-RF.10 Connections: Buspro, Ethernet, Buspro wireless Work Mode: Mesh mode or Bridge mode Wireless.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Chapter One : DALI100. Chapter Two : Parameter of DALI Input : 5V by USB ; Maximum Current 500mA ; Output : V ; Maximum Current 250mA ;
0 Configuring a 3500 Using iTools 2 iTools Workshop - getting started Start iTools and from the New File menu choose 3504 v1.04 programmer.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
ABB i-bus® EIB Shutter Actuators
DALI-Gateway DG/S 1.1.
ABB STOTZ-KONTAKT GmbH DALI-Gateway DG/S
DALI Scene Controller HDL-MC-DALI.431.
DALI Scene Controller HDL-MC-DALI.431.
Wireless Power Interface
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
Room Controller RC/A 8.1 Room Controller economic flexible modular.
Multifunctional Sensor
3DoT Technical Documentation
automatic recognition of load-type superior functionality
SB-DN-Logic960 Logic module.
Monitoring systems COMET types MS55 & MS6
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
DALI-Gateway DG/S 8.1.
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
AA/S 4.1 Analogue Actuator AAM/S 4.1 Analogue Actuator Module
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
FTC Driver Station Setup and Operation Mike Zook 20-Sep-2016.
Wireless Relay HDL-MPR01-RF.18.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
DMX Controller SB-DN-48DMX.
Chapter One:DALI100 Output:DALI1,DALI2,without difference of positive and negative Input:connected to computer with USB Power Indicator Light DALI Commend.
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
with UCM/KNX Rev Sept 2010 Ref: UCM/KNX Manual
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
FTC Driver Station Setup and Operation Mike Zook 20-Sep-2016.
MOSFET Dimmer Actuator
Wireless Relay HDL-MPR02-RF.18.
Curtain Actuator M/W
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
ABB i-bus® EIB / KNX Binary Input BE/S x.x.1
PLC Hardware Components.
4 channels, each as input or output
2 channels, each as input or output
ABB i-bus® EIB Logic Module LM/S 1.1
Universal Dim Actuator UD/S
RT9114B GUI User Manual V3.0.
Presentation transcript:

Dimmer 6fold 10V Actuator M/DA6.10.1

Dimmer Introduction M/DA06.10.1 has 6 Channel 0-10V dimming, maximum 10A relay output for every channe, also can manually switch. Control types include input and output, so, absorption and output type ballast can be connected to this module.  

Wiring Dimming Output: DC0-10V, 20mA per channel Channel Current: 10A/CH

Channel state feedback 1bit: normally use this object to feedback the channel state to the button, so the button indicator can show the correct state of it. if the channel brightness>0, send out command '1'; if the brightness=0, send out command '0'. 1 byte: normally use this object to feedback the channel specific brightness to the app, then the app can show the percentage value of its brightness.

Threshold value

ON/OFF fade time ON/OFF fade time: For example, you set 3 seconds and turn it on by pressing a user panel, the load will turn on slowly and reach the max brightness 3 seconds later.

Relative/absolute dimming Relative dimming: long pressing the button to dim up/down, adjust the brightness visually. Absolute dimming: The channel will output a certain brightness when receives a percentage telegram

Scene Scene: the combination of several channels’ status (on/off or different brightness levels.) This dimmer supports 64 scenes totally, and each channel can be applied to 10 scenes at most Assign current channel to some scenes and set the brightness for different scenes in scene page.

Sequence Sequence: the combination of difference scenes with playing parameters. one sequence can have up to 24 steps, one step can call one scene, set the step running time, when this time elapses, will turn to next step.

Configuration/Dimming on/off control & relative dimming: on/off(channel output): 1 bit data point, here we assign group address 1/0/2, 1/0/3 for channel1,2 respectively. relative dimming: it is enabled by default, 4 bit data point, here we assign group address 1/3/2, 1/3/3 for channel1,2 respectively.

Configuration/Dimming In the panel setting page, select the ‘Dimming controller’ as the work mode. assign the same gourp addresses of channel1,2 for Rocker A, B respectively, then can use Rocker A to control channel1, Rocker B to control channel2: short press the button, for on/off control; long press the button, for dim up/down control.

Configuration/Dimming absolute dimming: absolute dimming: it's disabled by default, enable it, it's 1 byte data point, here we assign group address 1/4/2, 1/4/3 for channel1,2 respectively.

Configuration/Dimming For absolute dimming: In the panel setting page, select the ‘Percentage controller’ as the work mode for rocker C. set the favorite brightness for each button's short/long press operation same as rocker D.

Configuration/Dimming assign the same group address of channel1 absolute dimming object for Rocker C, then can use Rocker C to control channel1: short press rocker C left button, channel1 will output 100%; long press rocker C left button, channel1 will output 0%; short press rocker C right button, channel1 will output 80%; long press rocker C right button, channel1 will output 50%. same as rocker D

Configuration/Scene Channel A: Set the channel A brightness for different scenes, e.g. Scene1 is 30%, scene2 is 60%, scene3 is 0%;

Configuration/Scene Channel B: Set the channel B brightness for different scenes, e.g. Scene1 is 50%, scene2 is 80%, scene3 is 0%; same steps for channel C, channel D

Configuration/Scene here we assign group address 1/5/2 for scene object

Configuration/Scene In the panel setting page, select the ‘Scene controller’ as the work mode. press rocker E left button to call scene1, channel A will go to 30%, channel B will go to 50%, etc; press right button to call scene2, channel A will go to 60%, channel B will go to 80%, etc.

Configuration/Sequence set to call one scene for each step, e.g. setp1 call scene1, step2 call scene2, step3 call scene3. set the step running time, here is 5s. control mode is forward, running mode is cycle, when running the sequence, it will execute: step1->step2-step3->step1->step2->...

Configuration/Sequence In the panel setting page, select the ‘Sequence controller’ as the work mode. assign the same group address for sequence object in dimmer and button E.