CSF Round Robin Program

Slides:



Advertisements
Similar presentations
Quality is a Lousy Idea-
Advertisements

Instrumental Analysis
Biological Variation Data: Time for Development of Standards? Dr William A Bartlett, On behalf of the Biological Variation Working Group, European Federation.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Summary 1 l The Analytical Problem l Data Handling.
1 Global Biomarker Standardization Consortium Chairs: Holly Soares, Henrik Zetterberg, Piotr Lewczuk.
Consensus Standards, Method Uncertainty and Quality Assurance in Analytical Chemistry Curricula Kevin Ashley, Ph.D. U.S. Department of Health and Human.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Validation of Analytical Method
Prevalidation Study Plan for Sliced Testes Assay Gary Timm Presented to EDMVS August 20, 2003.
Analytical considerations
HD 2007 Rule Diesel Fuel Sulfur Testing and Sampling Methods and Requirements US EPA Office of Transportation and Air Quality November 20, 2002.
Quality WHAT IS QUALITY
1 Global Biomarker Standardization Consortium: CSF Reference Method Sub-group Chairs: Kaj Blennow & Henrik Zetterberg.
Chem. 31 – 9/21 Lecture Guest Lecture Dr. Roy Dixon.
STUDY DESIGN: PILOT STUDIES Charles Flexner, MD Johns Hopkins University.
Quality Control Lecture 5
Role of RENAR and the Ministry of Research in Promoting Interlaboratory Comparisons (ILCs) Daniela-Eugenia CUCU RENAR.
Evaluation of the Presage™ ST2 ELISA Jun Lu 1, David G. Grenache 1,2 1 ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 2 Department.
Notes of 21nov2011 Alz. Assoc. CSF Reference Method Sub-group.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Estimating measurement uncertainty
Lab Skills Recap Biotech II. Metrology Vocabulary Unit of measurement Accuracy Precision Standards Calibration Verification Traceability Tolerance Errors.
Proficiency Testing Bryanne Shaw Biology Section Manager.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
TESTS OF SIGNIFICANCE. It is a test to compare the results of the method with those accepted method.
EQUIPMENT and METHOD VALIDATION
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
Introduction to Quality Assurance. Quality assurance vs. Quality control.
Plasma Free Metanephrines Analysis using LC-MS/MS with Porous Graphitic Carbon Column Xiang He (Kevin) and Marta Kozak Thermo Fisher Scientific.
Indranil Sen, Wei Zou, Ryszard Gajek, Jianwen She*
Table 1. Quality Parameters Being Considered for Evaluation
Alz. Assoc. CSF Reference Method Sub-group
Alz. Assoc. CSF Reference Method Sub-group
Quality is a Lousy Idea-
Josiane Arnaud1, Jean-Philippe Weber2,
Update on the Alzheimer’s Association Quality Control (QC) program
Global Biomarker Standardization Consortium
The Alzheimer’s Association QC program for CSF biomarkers
James Byrd, Marta Kozak 28 Apr 2011
Biomarker Core WWADNI report
Bioanalytical Laboratories
Serpil KILIÇ, Murat KILIÇ
Cerebrospinal fluid levels of the synaptic protein neurogranin correlates with cognitive decline in prodromal Alzheimer's disease  Hlin Kvartsberg, Flora.
Leslie M Shaw and John Q Trojanowski, UPenn
Institute for Reference Materials and Measurements (IRMM)
World Health Organization
IFCC Project Update on New Projects
NeuroMET and biomarkers
Robust Measurement of Branched Chain Amino Acids on the Vantera Clinical Analyzer and the Clinical Association of NMR-Measured Valine with Type 2 Diabetes.
2017 Update on the Alzheimer’s Association
IRMM/IFCC Project Overview
The analysis of domoic acid using alkaline UPLC-MS/MS
Leslie M Shaw Perelman School of Medicine University of Pennsylvania
Appropriate Use Criteria for Lumbar Puncture and Cerebrospinal Fluid Analysis in the Diagnosis of Alzheimer’s Disease Leslie M Shaw Department of Pathology.
Practical clinical chemistry
Quality is a Lousy Idea-
Integration of Certified Reference Material (CRM)
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Integration of CRM by Companies
Blood-Based Biomarkers in the QC Program?
Biomarker Core WWADNI report
ADNI Biomarker Core update
World Health Organization
DETERMINATION OF GLUCOSE IN BLOOD STREAM
Darrell Clinton and H. Dorota Inerowicz Purdue University
DIFFERENCES IN ANALYTICAL SELECTIVITY OF β-AMYLOID (1-42) IMMUNOASSAYS EXPLAIN DISCORDANT RESULTS IN STUDY COMPARISONS  Hugo Marcel Vanderstichele, Emeric.
Presentation transcript:

CSF Round Robin Program Alzheimer’s Association Global Biomarkers Standardization Consortium CSF Round Robin Program Leslie M Shaw Perelman School of Medicine University of Pennsylvania

CSF round robin program overview Initial focus: CSF Ab1-42 Analytical methodology: srm/tandem mass spectrometry Involve volunteer labs with significant experience in mass spectrometry analyses of biomarkers Follow an agreed on protocol Assess precision across 4 participating labs using CSF pools Share raw data amongst the labs Statistical analysis Report data to peers and, if successful, plan a follow-up study using a common standard Ab1-42 calibrator—this study is called “Ring Trial” Publish this pilot study The Ring Trial designed by and oversight by IRMM

CSF round robin program The 4 participating labs: Waters (Erin Chambers); PPD (Rand Jenkins); UPenn (Les Shaw); UGot (Kaj Blennow) Initial reports of methods in literature and in ASMS & AAIC meetings Initial pilot study compared performance across 4 participating laboratories; initial report at the AAIC 2013 meeting; manuscript accepted for publication in Alz & Dementia N=12 CSF pools (prepared & shipped by UGot to each participant laboratory Use of a common sample preparation methodology 3 different mass spectrometer systems and 3 different HPLC systems 4 different calibration matrices Single-plex, triplex or pentaplex methods utilized Different batches of high purity rPeptide Ab1-42 standard utilized

Alzheimer’s Association Global Biomarker Standardization Consortium Four Center collaborative study of mrm/tandem mass spectrometry reference methodology for measurement of Ab1-42 in 12 CSF pool samples 3 MS platforms Thermo TSQ Vantage Waters TQ-S ABI Sciex API 5000 3 HPLC platforms ACUITY 1D ACUITY 2D Accela 1250 4 different surrogate matrices Artificial CSF + 5% rat plasma Artificial CSF + 4 mg/mL BSA Salt and phosphate buffer solution + 4 mg/mL HSA, 0.05 mg/mL IgG, glucose Human CSF using N15 labeled Ab1-42 as calibrator Single-plex, tri-plex or penta-plex methods employed Sample preparation is the same across the 4 centers

Laboratories participating in the Global Biomarker Standardization Consortium collaborative study Erin Chambers & Mary Lame, Waters & Pfizer Moucun Yuan, Junlong Shao, William R. Mylott, and Rand Jenkins, PPD Magdalena Korecka, John Trojanowski, Leslie Shaw, UPenn Henrik Zetterberg, Kaj Blennow, Josef Pannee, Erik Portelius, Johan Gobom, UGot

Alzheimer’s Association Global Biomarker Consortium mrmMSMS Study data for 12 CSF pools

Mean within center %CV = 4.8% Mean between center %CV = 12.2% 658±130 728±101 342±52 Mean within center %CV = 4.8% Mean between center %CV = 12.2% 347±48 304±23 859±120 398±37 474±64 432 ±52 203±14 392±40 462±45

Four center Round Robin study Common calibrator Resp. factor calculated for each lab using CSF#11 to reconstruct each cal. curve. Peters et al, Anal Chem, 2007. Avg Interlaboratory %CV: 12.2 % 8.3% The hypothesis that use of a common calibrator and calibration scheme will reduce interlab %CV is tested In the Ring Trial. Panee J, et al, Alz Dementia, in press.

Summary Initial pilot study comparing performance across 4 participating laboratories completed The 4 participating labs: Waters (Erin Chambers); PPD (Rand Jenkins); UPenn (Les Shaw); UGot (Kaj Blennow) N=12 CSF pools (prepared & shipped by UGot to each participant laboratory Use of a common sample preparation methodology 3 different mass spectrometer systems and 3 different HPLC systems 4 different calibration matrices Single-plex, triplex or pentaplex methods utilized Different batches of rPeptide Ab1-42 standard utilized Very good agreement across the 4 laboratories is consistent with the ruggedness of the methodologic approach and supports their working together on the IFCC ref method assignment of accurate Ab1-42 concentrations to planned CSF-based standard reference material The 4 centers committed to a follow-up interlab study, as part of an IFCC/IRMM guided-study effort, that has been completed for 5 participating labs and there are individual studies completed addressing areas of interest: Calibrator matrix comparison studies CSF stability The mrm/tandem mass spectrometry-based methodology with high conc GuHCl followed by mixed-bed (ion exchange/RP) cartridge sample preparation is a suitable candidate reference method for assigning accurate and precise Ab1-42 values on CSF-based reference material.

Next steps Use the IRMM preparation of Ab1-42 Pilot: 2 lab (UGot and UPenn) study using 10 CSF pools prepared at UPenn→lab to lab comparison--completed Preliminary testing of the IRMM dilution protocol--completed conduct the full IRMM – guided “ring” trial—completed for 5 participating labs Compare across participating centers Use gravimetric protocol for preparation of calibrators and include calibrators prepared by individual lab protocol in the two replicate runs 20 patient CSFs, two complete separate runs in each participating laboratory Statistical analyses Report results-discussed at the June 2015 IFCC meeting in Paris Use these qualified methods for assignment of concentration to the CSF pools for creation of reference materials-IFCC/IRMM--planned Applications of mass spectrometry-based Ab1-42 analysis: Comparisons to existing and new immunoassays including analytical performance and clinical performance-the Commutability Study Provides an accuracy-based “anchor” in methods comparisons Studies in various patient populations of Ab1-42, and various metabolites for assessment of age and or disease related changes in metabolism, eg, assessment of Ab1-42/1-40 ratio for AD amyloid pathology detection

Comparison between two candidate reference methods (UGot and UPenn) Two candidate ref methods 10 CSF pools 3 replicate runs Used Ab1-42 prep provided by IRMM for the Ring trial & each lab used their calibration dilution protocol. Y=1.021X – 11.8 R2=0.989 XXXXXXXXXX

Ring trial with common protocol for calibration 9 % 6 datasets: Uncertainty for value assignment:   Acceptable for value assignment of the CRM ! Prepared by Ingrid Zegers

Applications of mass spectrometry-based Ab1-42 analysis-comparison of clinical performance to an existing immunoassay

CSF Ab1-42 vs ratio Ab1-42/Ab1-40 (AD[n=41], HC[n=41]) AUC=0.92 Ab1-42/Ab1-40 AUC=0.90 Methodology for CSF Ab1-42 and Ab1-40: validated UPLC/tandem MS/MS (Korecka, et al, 2014).