Maxillary Single Implant Case Angular & Linear Correction in 2 Planes

Slides:



Advertisements
Similar presentations
Assembly Instructions DucoSlide Luxframe Controllable TOP BOTTOM L.H. R.H. Control side FRONT SIDE in open position REAR SIDE in open position 1.
Advertisements

MILLING.
1 GRASP SAAST 2005 Robotics University of Pennsylvania Dave Cappelleri Piston Project: Machining Basics.
Click on this image to open the full PDF document.
Cutting With a Jeweler’s Saw
Split Sole 45 Degree Raker
MyLock 644D Service Seminar.
The Larsen Auto Blocker Calibrating Your System for Maximum Productivity and Quality.
1- Pipsqueak Engine Millwork on uprights and base.
…………..Continued Recap Machine tool Lathe machine Basic components
Assembly Manual Mike Fortney 04/02/2006 CricketSat Receiver.
Introduction to Assemblies Chapter 6. Assemblies Assembly files consist of multiple parts and the mates that define constraints between parts By default,
Lathe.
USING THE LATHE TO MAKE THE TENSILE TESTING SAMPLE
Lathe and drilling machines
Sectional Views Section Views.
PREPARED BY: NOR HELYA IMAN KAMALUDIN
LAUNCHER BASE PARTS B A D E F C G. LAUNCHER BASE PARTS B A D E F C G.
Lesson No. 11 Week No. 07 Name of lesson Marking Tools
LINEAR MEASUREMENT.
Unit 4 Machine Tools Machine Tools (Basic Elements, Working principle
Lathe and drilling machines
Arrangement of the posterior teeth
Arrangement Of The Anterior Teeth
ZDC Remote Handling Tool Structure and Force Analysis P. Debbins University of Iowa December 10, 2009.
Setting up correctly Different types and their use
How to Change Raptor Knife Blades. Step 1: Use a Phillips screwdriver to remove the 5 screws. It is not necessary to remove the lanyard/webbing to change.
Presentation by ANAS AHMAD ME1 B1 batch Submited to
Installing Hinges Created By M.Martin 9/05. Mark the hinge position on the door edge 150mm from the top of the door and 225mm from the bottom of the door.
Sectional Views Section Views.
Learning Objectives • Create sweep features. • Create lofted features.
Simon Calibration Instructions Main Antenna Jig Peter Karlsson V2.
ELEMENTS OF MECHANICAL ENGINEERING
THE CENTRE LATHE - 'FACING OFF' A very basic operation is called ‘facing off’. A piece of steel has been placed in the chuck and the lathe cutting tool.
# 23 SINGLE IMPLANT CASE Osteotomy Progression in Open Guide Sleeve
UNIT-II TURNING MACHINES
Guide Right™ Edentulous Maxillary Arch
Unit 4 Machine Tools Machine Tools (Basic Elements, Working principle
Guide Right™ CASE FOR ANGLED IMPLANTS
Teknologi Dan Rekayasa
Use of Pythagorean Theorem in #9 Single Implant Case
Easy centering and setting system
UNIT-II TURNING MACHINES
Occlusal Schemes.
Guide Right™ Immediate Placement & Immediate Load
Pythagorean Theorem COSINE Calculations for Guide Right™ Guides
ModICE Modular Integrated Connector Enclosure
Guide Right™ Surgical Guide System
Teknologi Dan Rekayasa
UNIT-I SLOTTING MACHINES
Adjustment of complete denture occlusion
Elevators.
Introduction to Engineering – E10
Sectional Views Section Views.
Serial Guide Technique
dental anatomy terminology
Facing & Center Drilling
MECHANICAL ENGINEERING
Excel Basic Operation Manual
Horizontal Milling Operations
Chapter 03- Angular Measurements PRESENTED BY Ms. M.R. Zade
Assembly instructions for M-K all bolt together hoppercone kit.
Mounting a BalanceBox®650 to a brick wall
Technical Drafting –p401 Before a technical object can be manufactured, its shape and dimensions must be determined. A technical drawing must be created.
Mechanical Incisal Guide Table
2.7 and 3.7 “I can use benchmark angles to estimate the measure of angles, and use a tool to measure and draw angles.” “I can understand that the measure.
How to Use a Protractor.
Drawing Section Views.
Sectional Views Section Views.
Orthographic Projection
Presentation transcript:

Maxillary Single Implant Case Angular & Linear Correction in 2 Planes Bending Tool ► 2 Bends Offset Guide Posts Open Guide Sleeves GALAXIS software Featuring: #7 MAY 2.2013

Fabrication of DIAGNOSTIC Guide

#7 Initial wax up.

A hole is drilled through the prosthetically planned long axis of the implant into the cast with a 3/32” drill. A 3 mm guide post is placed in the hole.

A straight 3 mm guide sleeve is placed on the 3 mm guide post with the cleats positioned toward the palatal surface.

Close up showing guide sleeve cleats positioned to the palatal.

Lubricant is applied to cast prior to fabrication to enhance removal of guide from cast. Triad® Gel is added to the guide sleeve to capture the cleats, including lingual & incisal surfaces of several of the adjacent teeth,. After curing the DIAGNOSTIC guide & securely seating it in the patient, an X-ray is taken.

GALAXIS Cone Beam Images PRE-OPERATIVE Evaluation GALAXIS Cone Beam Images

Preview of Pre-op Corrections #7 LINEAR CORRETION 1.5 mm offset toward the palatal ANGULAR CORRECTION 1st Bend: 10° bend to the facial 2nd Bend: 5° bend toward the mesial

3.0 x 1.5 mm offset guide post toward the palatal is used SURGICAL guide 3.0 x 1.5 mm offset guide post toward the palatal is used

LINEAR CORRECTION: 1st ANGULAR CORRECTION: 1.5 mm toward the palatal 10° toward the facial DIAGNOSTIC guide sleeve in place F F GALAXIS cross sectional views

Single 10° bend in one plane Guide Right™ Generation ll / Guide Post Bending Tool Single 10° bend in one plane

Guide Right™ Generation ll / Guide Post Bending Tool • A straight 3 mm magnetic guide post is placed in the bending tool. • The 3mm stylus is place over the post. • Pressure is applied to the point of the stylus to bend the post 9° according to the reading on the protractor.

Guide Right™ Generation ii / Guide Post Bending Tool SINGLE BEND review Step 2 Locate 3/32” hole in the center of the v-cut and place the bottom half of the guide post into the hole. Tighten the set screw. Step 1 Place bending tool plate on a secure flat surface with the degree increments at the top & the stainless steel bar with the v-cut at the bottom. Step 3 Locate the hole in the bottom of the stylus that you will use that will fit over the top half of the guide post (3.0 mm, 4.0 mm or 5.0 mm). Step 5 Using the stylus as a lever, bend the guide post to the degree of angle of correction. You may need to ease the point of the stylus beyond the point of the desired degree. Step 6 Loosen screw and remove guide post and the stylus to find the guide post bent to the desired angle. Step 4 Fit the stylus over the guide post securely with the point directed at zero degrees and the bottom of the stylus in contact with the V block.

2nd ANGULAR CORRECTION: 5° toward the facial Tangential (mesio-distal) 5 ° correction GALAXIS

Guide Right™ Generation ii / Guide Post Bending Tool COMPOUND BEND overview Step 1 Position a straight or offset guide post in the bending plate, tightening the set screw against one of the flat surfaces on the lower half of the guide post. Step 4 The 2nd bend in the second plane is made after rotating the guide post up away from the surface of the bending plate to register the stylus point back at 0 degrees. Step 5 Slide the stylus support bar down under the stylus until it supports the stylus. Tighten the side screws before making the second bend. Step 7 Remove the stylus and place the guide post back in the cast with the appropriate side indicated by a mark facing the buccal or lingual surface. Be sure the post is in the correct position. If the post needs to be corrected by a linear movement an offset guide post can be used. Off sets available in the 3 mm guide post: 0.5,1,1.5, 2.0 ,or 3.0 mm. Step 3 The set screw is loosened and the guide post is rotated 90 ° next flat surface. Step 2 The 1st bend can be made to the right or left direction. Step 6 The second bend can be made in either direction according to the x-ray.

Magnetic Guide Posts 3.0 mm od Offset 3.0 od X 0.5 mm os Straight 3.0 mm od Offset 3.0 od X 0.5 mm os 3.0 od X 1.0 mm os 3.0 od X 1.5 mm os 3.0 od X 2.0 mm os 3.0od X 2.5 mm os 3.0 od X 3.0 mm os

Guide Right™ Generation ll / Guide Post Bending Tool Showing required 5° mesio-distal correction with stylus support bar in place. 2nd BEND

Fabrication of SURGICAL Guide

Palatal view: 1.5 mm offset guide post offset placed toward the facial Facial view: 1.5 mm offset guide post in place

Facial view: guide sleeve in place Facial view: Triad® Gel added to form the SURGICAL guide

Direction Indicator placed after 2 mm drill is used. Final implant placement.

Guide Right™ Products shown in this case 3/32” drill 3 mm Guide Post 3 mm Guide Sleeve 1.5 mm Offset Magnetic Guide Post 3 mm Open Guide Sleeve 2 mm Direction Indicator Petroleum Jelly Generation ll/ Guide Post Bending Tool Triad® Gel 1.800.314.0065 • www.deplaque.com

Guide Right™ Surgical Guide System DéPlaque Guide Right™ Surgical Guide System fabricate ▪ evaluate ▪ correct ▪ verify ▪ place Start With Precision. Place With Confidence.™ 1.800.314.0065 • www.deplaque.com