M. Chefdeville LAPP, Annecy RD51/WG2, CERN, 29/04/2009

Slides:



Advertisements
Similar presentations
Peter Speckmayer, LCWS2010, Beijing 1P. Speckmayer, LCWS2010, Beijing3/27/2010.
Advertisements

Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
RPC Update José Repond Argonne National Laboratory American Working Group On Linear Collider Calorimetry 16 September 2003 What’s new since Cornell…
1/9/2003 UTA-GEM Simulation Report Venkatesh Kaushik 1 Simulation Study of Digital Hadron Calorimeter Using GEM Venkatesh Kaushik* University of Texas.
Micromegas for a DHCAL LAPP, Annecy Catherine Adloff Jan Blaha Sébastien Cap Maximilien Chefdeville Alexandre Dalmaz Cyril Drancourt Ambroise Espagilière.
David Attié Club ‘ILC Physics Case’ CEA Saclay June 23, 2013 ILD & SiD concepts and R&D.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
Andy White University of Texas at Arlington For GEM DHCAL Group ESTB Workshop SLAC 2012 Introduction KPiX Readout FTBF Beam Test Setup Beam Test Analysis.
Catherine Adloff16 June 2009 CALICE Technical Board 1 DHCAL-MICROMEGAS Yannis KARYOTAKIS For the LAPP group.
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 1 Paul Dauncey Imperial College London.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
M. Chefdeville LAPP, Annecy, France. Introduction  Motivations for a Digital hadronic calorimeter Count hits instead of measuring energy deposits Reduce.
CALICE Digital Hadron Calorimeter: Calibration and Response to Pions and Positrons International Workshop on Future Linear Colliders LCWS 2013 November.
LAPP/Demokritos H4 setup Sampling Calorimetry with Resistive Anode Micromegas (SCREAM) Theodoros Geralis NCSR Demokritos RD51 mini week, 8 – 11 December.
Activités R&D du groupe LC Détecteur au LAPP R. GAGLIONE pour C. ADLOFF 7 Décembre 2011.
UTA GEM DHCAL Simulation Jae Yu * UTA DoE Site Visit Nov. 13, 2003 (*On behalf of the UTA team; A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee,
1 MICROMEGAS for Imaging Hadronic Calorimetry at Linear Colliders Catherine ADLOFF on behalf of the CALICE collaboration.
Development of Digital Hadron Calorimeter Using GEM Shahnoor Habib For HEP Group, UT Arlington Oct. 12, 2002 TSAPS Fall ’02, UT Brownsville Simulation.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
Digital Hadron Calorimetry Using Gas Electron Multiplier Technology CALICE Meeting, NIU March 2005 Andy White (for the GEM-DHCAL group: UTA, U.Washington,
A Hadron Calorimeter with Resistive Plate Chambers José Repond Argonne National Laboratory CALOR 2006, Chicago, June 5 – 9, 2006.
MicroMegas for DHCAL Status and activities at LAPP Catherine Adloff Jan Blaha Sébastien Cap Maximilien Chefdeville Alexandre Dalmaz Cyril Drancourt Ambroise.
On behalf of the LCTPC collaboration VCI13, February 12th, 2013 Large Prototype TPC using Micro-Pattern Gaseous Detectors  David Attié 
European DHCAL development European DHCAL development CIEMAT,IPNL,LAL, LAPP,LLR, PROTVINO, SACLAY CIEMAT,IPNL,LAL, LAPP,LLR, PROTVINO, SACLAY Status :
Digital Hadron Calorimetry for the International Linear Collider Using Gas Electron Multiplier Technology Andy White University of Texas at Arlington (for.
1 Status of the MICROMEGAS semi-digital HCAL M. Chefdeville, LAPP LC Detector group, Annecy CALICE meeting, CERN, 21/05/2011.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Status of the MICROMEGAS semi-DHCAL M. Chefdeville LAPP, Annecy, France LCWS, 27 th March 2010, Beijing 1.
Catherine Adloff28 Jan 2008 SiD Collaboration Meeting 1 DHCAL and MICROMEGAS at LAPP Catherine Adloff Franck Cadoux Sébastien Cap Cyril Drancourt Ambroise.
DHCAL Jan Blaha R&D is in framework of the CALICE collaboration CLIC08 Workshop CERN, 14 – 17 October 2008.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
SDHCAL. outline  SDHCAL concept, validation and construction  Test Beam and technological prototype performance  Perspectives and Conclusion  SDHCAL.
Analysis of DHCAL Data José Repond Argonne National Laboratory CALICE Meeting, September 16 – 18, 2009 Université Claude Bernard Lyon I, France.
1 Micromegas for sampling calorimetry Chronology & people  Initiated by LAPP LC-group in 2006 (C. Adloff, M. Chefdeville, Y. Karyotakis, I. Koletsou)
LAPP Introduction Catherine ADLOFF for Yannis KARYOTAKIS.
CALICE, Shinshu, March Update on Micromegas TB analysis Linear Collider group, LAPP, Annecy CALICE collaboration meeting 5-7 March 2012, Shinshu,
W-DHCAL Digitization T. Frisson, C. Grefe (CERN) CALICE Collaboration Meeting at Argonne.
Physics performance of a DHCAL with various absorber materials Jan BLAHA CALICE Meeting, 16 – 18 Sep. 2009, Lyon, France.
1 Micromegas for imaging calorimetry XVth International Conference on Calorimetry in High Energy Physics June , Santa Fe M. Chefdeville, CNRS/IN2P3/LAPP,
Thick-GEM sampling element for DHCAL: First beam tests & more
Large Prototype TPC using Micro-Pattern Gaseous Detectors
Test Beam Request for the Semi-Digital Hadronic Calorimeter
The European DHCAL status
Results achieved so far to improve the RPC rate capability
The 1m2 Micromegas prototype for hadronic calorimetry
CEPC 数字强子量能器读出电子学预研进展
R&D advances on Micromegas for a semi-DHCAL
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
Recent DHCAL Developments
SiD Calorimeter R&D Collaboration
DHCAL and MICROMEGAS at LAPP
Activités du groupe LC Détecteur au LAPP
(My personal) CALICE Report
Semi-Digital Hadronic CALorimeter
Tao Hu, Jianbei Liu, Haijun Yang, Boxiang Yu For the CEPC-Calo Group
MicroMegas DHCAL : Résultat des tests en faisceau et simulation
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Study of energy shower profile and 1m3 energy resolution Jan Blaha Laboratoire d'Annecy-le-Vieux de Physique des Particules MicroMegas Physics.
Status of the MICROMEGAS semi-digital HCAL
GEM-based Digital Hadron Calorimetry for SiD
   Calorimetry et al.    SUMMARY 12 contributions Tile HCAL
AIMS 1- Build SDHCAL prototype of 1m3 as close as possible to the one
Tests of a Digital Hadron Calorimeter
Status of CEPC HCAL Optimization Study in Simulation LIU Bing On behalf the CEPC Calorimeter working group.
Tests of a Digital Hadron Calorimeter
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
A DLC μRWELL with 2-D Readout
Presentation transcript:

M. Chefdeville LAPP, Annecy RD51/WG2, CERN, 29/04/2009 Environmental study of a Micromegas chamber for hadronic calorimetry at ILC M. Chefdeville LAPP, Annecy RD51/WG2, CERN, 29/04/2009

Outlook Introduction DHCAL R&D at LAPP Environmental study Conclusion Hadronic calorimetry at a future linear collider DHCAL R&D at LAPP Environmental study Experimental setup and gas gain model Basic properties of our Micromegas Gain, gas flow, mixing ratio, pressure, temperature, gap Conclusion

Matching energy deposits in calorimeter with tracks Calorimetry at ILC International Linear Collider e+/e- collisions at 500 GeV, 30 km long Luminosity of 2.1034 cm-2s-1 1 ms long bunch trains, 199 ms idle Detailed study of EWSB, Higgs boson properties, SUSY particles, extra-dimension models … 3 detector concepts with ≠ tracker and calorimeters ILD (TPC) – SiD (Silicon tracker) - 4th (Drift chamber) SiD and ILD based on Particle Flow Approach (PFA) Single particle shower imaging capability Highly segmented and compact calorimeters Resolution goal: 30 %/√E Hadronic Calorimeter design Total absorber depth of 4.5 λ, 40 layers, 8 mm gap Small cell sizes (down to 1 cm2!) Thin sensitive layers (solid or gas) Matching energy deposits in calorimeter with tracks

Analog and Digital HCAL Total instrumented area of 3000 m2! Find a compromise between Nchannel and cell size Analog HCAL Scintillating tiles of 5-10 cm2 Light readout with SiPM/MPPC 1 m3 prototype already tested Digital HCAL Gas layers with 1 cm2 pads 1 threshold per pad (single bit info.) GEMs, RPCs, Micromegas ILC oriented ASICs (HARDROC1/2) What is best for energy resolution? Measuring charge or counting hits? Actively simulated (J. Blaha contribution MPGD, Crete) Charge Hits Charge VS Hits

Detectors for a DHCAL Different types of gaseous detectors are currently under developments: Glass Resistive Plate Chambers (GRPC): Europe: IPNL (Lyon, France) and IHEP (Protvino, Russia) USA: ANL (Argonne, USA) Gaseous Electron Multiplier: ANL (Argonne, USA) MICRO MEsh GAseous Structure LAPP (Annecy-le-Vieux, France) R&D strategy: Development of small prototypes and their characterization Construction and test of 1 m2 and then 1 m3 prototypes Prototype performance comparison → final design for DHCAL

DHCAL R&D at LAPP What we are involved in: GASSIPLEX What we are involved in: Large area detector (WG1), Bulk Micromegas Physics simulation ASIC development (DIRAC chip) Detector test: 2 beam tests in 2008, 3 planned this year Prototypes: 1 cm2 pads, 3 mm of Ar/iC4H10 95/5 Analog readout prototypes for characterization (GASSIPLEX chips), 6x16, 12x32 cm2 Digital readout prototypes with embedded electronics (HARDROC/DIRAC chips), 8x32, 32x48 cm2 Bulk 6x16 cm2 HARDROC / DIRAC mask Bulk 8x32 cm2 FE Electronics + PCB + Bulk + drift + cover = 8 mm Possibility to chain detectors

Small HCAL performance 4 chamber stack Gas gain ~ 15000 Analog readout (pedestal of 3 fC) CERN H2 & T9 beam lines Muons and pions (absorber option) Results Most Probable Charge ~ 25 fC 10 % variation for largest chamber 95 % efficiency to 200 GeV muons Hit multiplicity < 1.1 ADC counts Normalised MPV Number of Pads Efficiency Chamber 0 97,05 ± 0,07% Chamber 1 98,54 ± 0,05% Chamber 2 92,99 ± 0,10% Chamber 3 96,17 ± 0,07%

Tests with digital readout Not much done sofar Problems with HV, DAQ software Still, predictions can be made from tests with analog readout prototypes Beam Profile recorded with a DIRAC ASIC Landau 200 GeV muons Expected efficiency Efficiency for a 20 fC threshold is rather low (70 %) Efficiency sensitivity to changes in various parameters should be known.

Our study Study effect of various variables on gain Two studies: Gas variables: gas flow, mixing ratio Ambient variables: pressure, temperature Amplification gap Two studies: Environmental study: G(t), P(t), T(t) G(V), lot to be learnt from gain curve too! Experimental setup: Gas system: 2 bottles of Ar and CO2 mass flow controllers (1% accuracy) rotameters, chamber stack and bubblers Readout of mesh (55Fe) signals: ORTEC preamplifier + ampli/shaper 12 bits ADC Slow control: Pressure and temperature gauges One chamber of the stack is used

Amplification properties Electron collection efficiency Probably some electron attachment Gas gain Maximum gain of 104 Energy resolution Twice larger than theoretical limit

Gas gain model & gain curve fit Using Rose and Korff parametrization of the Townsend coefficient: Gain sensitivity to P, T and g variations:

Environmental study Gain, pressure and temperature as a function of time 55Fe peak pressure Voluntary changes of room temperature Time period for G(T) study temperature Time period for G(P) study

Pressure and temperature Peak and pressure allow for ΔT of 1 K Pressure corrected peak and temperature Compatible with gain curve: -0.46 %/mbar Compatible with gain curve: 1.50 %/K

Previous measurements performed at flows > 0.5 l/h Gas parameters Effect of gas flow four chambers in parallel Total volume of 0.2 l Saturation for flow > 0.2 l/h = 1 chamber volume / hour Probably e- attachment Should improve gas tightness Ar/CO2 mixing ratio Gain decreases with CO2 fraction Gain curves at various concentrations (Get energy resolution for free) Previous measurements performed at flows > 0.5 l/h

Previous measurements performed at flows > 0.5 l/h Gas parameters Effect of gas flow four chambers in parallel Total volume of 0.2 l Saturation for flow > 0.2 l/h = 1 chamber volume / hour Probably e- attachment Should improve gas tightness Ar/CO2 mixing ratio Gain decreases with CO2 fraction Gain curves at various concentrations (Get energy resolution for free) Look at gain at given mesh voltage Previous measurements performed at flows > 0.5 l/h

Conclusion To summarize: these findings are applicable to other MPGDs Expected efficiency drop for G=104 and t=20 fC is mild More details on that study can be found at: http://lappweb.in2p3.fr/~chefdevi/Work_LAPP/environmental_study.pdf Acknowledgements: Catherine Adloff, Jan Blaha, Sébastien Cap, Alexandre Dalmaz, Cyril Drancourt, Ambroise Espagilière, Renaud Gaglione, Raphael Gallet, Nicolas Geffroy, Claude Girard, Jean Jacquemier, Yannis Karyotakis , Nicolas Lafaye, Fabrice Peltier, Julie Prast, Jean Tassan, Guillaume Vouters ΔP in mbar, ΔT in K, Δg in μm and Δf in % of CO2