Hutch 4 (XCS) Laser System

Slides:



Advertisements
Similar presentations
LCLS Studies of Laser Initiated Dynamics Jorgen Larsson, David Reis, Thomas Tschentscher, and Kelly Gaffney provided LUSI management with preliminary Specifications.
Advertisements

John Arthur Photon October 27, Photon Systems Overview John Arthur SLAC.
John Arthur Photon April 20, 2006 Photon Systems Update John Arthur SLAC Photon Systems Manager.
Ultrafast Experiments Hangwen Guo Solid State II Department of Physics & Astronomy, The University of Tennessee.
Chapter 7: Light Figure 7.8 Good APCs: 2, 3, 5, 6, 9, 10, 14, 18, 19, 20, 22, 23, 25, 28, 29, 30, 31, 42, 45, 46, and 48.
Simple Double Beam Spectrometer
Simple Double Beam Spectrometer
Tao Yuan, Jingzhou Xu, and Xicheng Zhang Rensselaer Polytechnic Institute, Troy, New York Scanning THz Emission Microscope Abstract A THz image system.
Date of download: 6/25/2016 Copyright © 2016 SPIE. All rights reserved. (a) Schematic of the noncollinear optical parametric amplification (NOPA) geometry.
10fs laser pulse propagation in air Conclusion The properties of femtosecond laser pulse propagation over a long distance (up to 100m) were studied for.
Generation of intense few-cycle pulses from the visible to the mid-IR Josh Nelson 1 Danny Todd 2 Adam Summers 3 Derrek Wilson 3 Dr. Carlos Trallero 3 1.
MESH Crystal Injectors
The Electromagnetic Spectrum High Harmonic Generation
Mathematical Derivation of Probability
Jonathan Donkers1, Lin Zhang1+
Measuring the Thickness of Cryosheet Jets
Madhu Karra1, Jason Koglin1,2
Observation of Quantum Beating in Rubidium at 2. 1 THz and 18
Image Processing For Soft X-Ray Self-Seeding
Structure and Function: Ubiquitination of NEMO and Optineurin
Modulation-frequency dependency of optical measurements in turbid media: Phantom and simulation studies E L Maclin1, J Kimnach1, K A Low1 , M Fabiani1,
Characterizing Optics with White-Light Interferometry
Matter in Extreme Conditions at LCLS:
Kevin Shimbo1, Matt Hayes+
X-Ray Shielding Introduction Application Research Conclusions
Crystallography images
Anomaly Detection LCLS data: Introduction Research Conclusion
MAKING WAY FOR LCLS II HERRIOTT CELL IGNIS THE NEED FOR LCLS-II
Designing and Prototyping Optics Table and Shelves
Managing Diffraction Beam
Integration of Blu-Ice into
Effects of Wrapping Vacuum
Scintillation Material Encapsulation Fixture
LCLS CXI Sample Chambers and Engineering Solutions
Values to Normalize Data
Designing a molecular probe for detection
LAMP Vacuum System Documentation
G6PD Complex Structural Study Crystallization Setup
Your Name, Elias Catalano, Robert Sublett, Robin Curtis
Determining a Detector’s Saturation Threshold
HXRSD Helium Enclosure
Crystallography Labeling Using Machine Learning
IT Inventory and Optimization
Structural study of soluble ammonia monooxygenase
Creation and development of a PRP database
IT Inventory and Optimization
Electro Optic Sampling of Ultrashort Mid-IR/THz Pulses
Margaret Koulikova1, William Colocho+
Soft X-ray Absorption and Coherence Analysis
Analytical Solutions for Heat Distribution in KB Mirror Systems
Repeatability Test of Attocube Piezo Stages
Analytical Solutions for Temperature
Bi-plasma interactions on femtosecond time-scales
Barron Montgomery1,2, Christopher O’Grady2, Chuck Yoon2, Mark Hunter2+
Elizabeth Van Campen, Barrack Obama2, Stephen Curry1,2, Steve Kerr2+
Advanced Methods of Klystron Phasing
Ryan Dudschus, Alex Wallace, Zachary Lentz
X-Ray Spectrometry Using Cauchois Geometry For Temperature Diagnostics
Robert Pushor, Catherine LeCocq, Brian Fuss, Georg Gassner
Redesigning of The SED Calendars
Automatic compression control for the LCLS injector laser
Russell Edmonds1, Matt Hayes2+ 1LCLS Summer Research Intern
Prototype and Design of High-Speed X-Ray Chopper
Title of Your Poster Introduction Research Conclusions Acknowledgments
Reconstruction algorithms Challenges & Future work
X-ray Pump-Probe Instrument
PIXEL Project Status John Arthur Photon Instrumentation for
Coherent X-ray Imaging Instrument WBS 1.3
X-ray Correlation Spectroscopy Instrument
LUSI Status and Early Science
Presentation transcript:

Hutch 4 (XCS) Laser System Commissioning Joseph Kaiser1, Mike Glownia2+ 1LCLS Summer Intern, Duke University, 2138 Campus Drive, Durham, NC 27708, USA. 2Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA. +Contact: jglownia@slac.stanford.edu 1 Introduction Hutch 4 (XCS) hosts experiments involving hard x-ray photon correlation spectroscopy and coherent hard x-ray scattering. A new 800 nm Ti:sapphire ultrafast laser system was added to this hutch to enable optical pump, x-ray probe experimental capability. To allow the laser light to travel from the laser room to the sample in the hutch, an entirely new beamline was created using two separate optical tables. The requirements of this new beamline included generating 400 nm and 266 nm light from the original 800 nm light, accurately varying the arrival time between x-ray and optical pulses, and creating up to far infrared light using an optical parametric amplifier (OPA). Keywords: laser, beamline, XCS, commission Fig 2. Visible 400 nm light, created from invisible 800 nm light, illuminating a sample placeholder used in the second commissioning experiment. Research The scope of work was as follows: Aid in alignment through irises onto target Secure mirrors, lenses, and polarizers in their mounts Characterize beam at interaction point using beam profiler camera Calculate theoretical and actual path lengths along white light, OPA, and tripler beam paths To comply with LCLS II goals, the table on which the OPA and frequency tripler are placed is mounted on wheels for enhanced mobility. However, the table's wheels added an unacceptable amount of instability. This was circumvented by cleverly anchoring the wheeled table to the immobile laser table closer to the beamline. The first commissioning experiment used 800 nm light to create phonons in bismuth which were observed directly. Figure 1 shows an ideal result for an experiment of this type; however, it was not created from data collected in this exact experiment. The existence of this signal demonstrates not only the beamline's precise control over the relative arrival time between x-ray and laser pulses using the delay stages but also its low energy loss from laser room to target. A challenging aspect of establishing this beamline was the constraint that the timetool white light beam path and the 800 nm/OPA beam paths had to differ by exactly the distance between the interaction point and the timetool itself on the beamline (Figure 3). This necessitated the use of two separate “dog-legs” that added path length without interfering with the rest of the beamline. Fig 3. Schematic of the XCS laser beamline. The difference in path length between the white light and OPA/tripler beamlines is such that the x-ray and optical pulses that interact at the timetool are the same pulses that meet at the interaction point. Put simply, the difference is precisely the distance between the interaction point and timetool. Fig 1.3 X-ray diffraction Bragg intensity oscillations for bismuth, similar to those produced in the first commissioning experiment. The oscillations were a result of optically generated lattice motion in the bismuth crystal. Image courtesy of PAL-xFEL. Conclusions Laser beamline commissioning is an uncommon event at LCLS. This commissioning can teach that an initial layout schematic is a most useful tool in alignment while working within constraints, such as path length difference. Later experiments will necessitate the use of the OPA to generate light with wavelengths ranging from about 200 nm to 20 µm. This beam path was not tested as thoroughly as the tripler beam path and adjustments will need to be made using the delay stages. With the installation of this laser system complete, XCS will be able to host a wider range of experiments, including types previously hosted by Hutch 3 (XPP). The second commissioning experiment involved the observation of charge carrier density changes in a liquid transition metal coordination compound with cyanide ligands. These changes were induced by an optical pump of 400 nm light, made from frequency doubled 800 nm light (Figure 2). Acknowledgments Use of the Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, is supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Contract No. DE-AC02-76SF00515. 3http://pal.postech.ac.kr/paleng/Menu.pal?method=menuView&pageMode=paleng&top=7&sub=5&sub2=0&sub3=0 Date: 08/09/2017