Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.

Slides:



Advertisements
Similar presentations
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
Advertisements

Show Controller——DMX Module 48 Channel——SB-DN-48DMX 512 Channel——SB-DN-512DMX Configuration of Show Control ler ( DMX Module ) 240 Channel——SB-DN-240DMX.
SB-CMS-PIR - ceiling mounted PIR sensor. Subnet ID and Device ID Device Remark Change the ID if needed.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
DLP LCD PANEL Programming
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. Addressing button HDL -BUS.
Touch screen function manual Right & left scroll key Room selecting key, Maximal quantity 50. Controlling Target icon Room background image brightness.
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
DMX Controller SB-DN-512DMX.
Hotel Room Intelligent System applications SMART-HDL.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
HDL KNX System Introduction
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
SB-DN-Logic960 Logic programmer / timer. Description  SB-DN-Logic960 is an intelligent programmable logic controller, it can control the system automatically.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Solutions for Hotel HDL-MHRCU.431.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Curtain Controller SB-DN-2Motor. SB-DN-2Motot is a professional two curtains(shutters) controller. The curtain module can control the curtain by AC motor.
目录 SB-CMS-8in1 Features ● 1 PIR motion sensor ● 1 Lux sensor ● 2 Dry contact inputs ● 2 external condition inputs ● IR(infrared) receiver ● IR(infrared)
Start up: 1. Power off and insert a GSM card, power on and check the GSM signal on the LCD. 2. Use the LCD and keys on the module to check and set the.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
System Important Points for Wiring
Air-Condition controller
Quick Start Guide for Flex Flow Pump
DIN Rail Music Player HDL-MZDN.432A.
Gateway HDL-MBUS01IP.431.
DALI Scene Controller HDL-MC-DALI.431.
DALI Scene Controller HDL-MC-DALI.431.
VOICE CONTROLLED SMART HOME AUTOMATION SYSTEM BASED ON ZIGBEE NETWORK
DIN Rail Music Player HDL-MZDN.432A.
Multifunctional Sensor
ILife App.
SB-DN-Logic960 Logic module.
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Dimmer 6fold 10V Actuator M/DA
Security module SB-DN-SEC250K.
Wireless Relay HDL-MPR01-RF.18.
DMX Controller SB-DN-48DMX.
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
with UCM/KNX Rev Sept 2010 Ref: UCM/KNX Manual
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
Connections Topology of Apollo ACS.
MOSFET Dimmer Actuator
RS232 Converter SB-DN-RS232N.
Security Module, MDRC SCM/S 1.1
Wireless Relay HDL-MPR02-RF.18.
Crouzet touch Quick start.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
GSM door opener Model RTU5015 RTU5025 .Different appearance ,the same function.
2N® Access Unit Touch Keypad
Setup 1; Add iMCB. Set up : Please check circuit and follow proper wiring before power up.
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Technisonic Industries TDFM-136
Maxsony Technology Limited
724 Temperature Calibrator
OWS + SureView Integration
RT9114B GUI User Manual V3.0.
Presentation transcript:

Dry contact sensor HDL-MSD04.40 HDL-MSD08.40

Description HDL‘s version 4 Dry Contact modules, 8 channel dry contact module (HDL-MSD08.40) and 4 channel dry contact module (HDL-MSD04.40). it is suitable to be used in a retrofit project where end-user would like to equip HDL buspro smart system but would also like to reserve their existing Switch (normal one). HDL-MSD04.40 HDL-MSD08.40

Basic information page remark Can change the ID, but the Subnet ID must the same with the gateway; The Device ID should be unique in its Sbunet. 5/28/2018

Configuration page The main tab for setting main configurations remark

Configuration page Switch type: Two different Switch types - Momentary and Toggle a) Momentary Switch - When pressed, it is on, when released, it is off. Generally select ‘signal on; signal on/off; combination on/off; etc..’ b) Toggle Switch – It is bi-stable switch, you can set it on or off. Generally select “Mechanic switch” mode for this kind of switch. a) b)

Configuration page Unqualifiedde: Delay time: Dimming: Set the dimming mode for each channel. Delay time: Just the “Mechanic switch” switch type has the delay time. Dimming: Set the Dimming value for each channel: Toggle- when turn on light, the brightness will go to 100%; Memory- save the brightness, when turn on light, the brightness will go to last brightness before turn off. 5/28/2018

Configuration page Target: Can set each channel’s targets, the target’s range is 1~99. 5/28/2018

Configuration page Low limit: The Lower limit is useful if you would like to skip the low level segment and dim from a certain level, say 50%. You want to skip it because maybe lower than 50% is impractical for you or maybe the load quality is not so good and trembles when at low level segment. . 5/28/2018

Configuration page Setting for keys: Key Enable: enable/disable the input channels. Panel Lock Key Enable: If be selected, can use panel to lock/unlock this channel. . 5/28/2018

Security setting page Temper proof Security settings 5/28/2018

Security setting page Security settings: Tamper proof: Can use channels of dry contact to trigger security, like the window state, door state. For further configuration, please turn to security module’s user manual. Tamper proof: When the wire is cut off, the Dry Contact module can report the status to the Security module and trigger the alarm by Security module. . 5/28/2018

Security setting page Tamper proof: Value Setting: When the Sensor is connected (e.g., close/open the window), click the “ON Read” button and you will get a value for “Connected (0-100)”,. when the Sensor is disconnected, click the “OFF Read” and you will get a value for “Disconnected (0-100)”, save. Note: If every time you read the value, the values changes dramatically, e.g., from 5, to 10, to 30, to 15 again, this means the contact is not reliable, you need to check. 5/28/2018

Security setting page Tamper proof: Target Setting: We can set the Alarm target for this channel 1, like trigger Security module (9-230) emergency alarm. When the wire is cut off, it will trigger the targets in Alarm Commands page. e.g. trigger security emergency alarm: PS: You need to authorize the ID (of the Dry Contact module) in Security module, for more setting about Security module, please turn to corresponding doc. 5/28/2018