Modelling the impact of integrated EV charging and domestic heating strategies on future energy demands Nick Kelly, Jon Hand, Aizaz Samuel ESRU, University.

Slides:



Advertisements
Similar presentations
Chen Xin (Vivian). Energy Consumption by Sectors.
Advertisements

Low Energy Building Design Group B Romain Jauffres, Karen Kennedy, Pedro Ros Zuazua, Ulrich Sanson Embedded Generation.
Institute of Energy & Sustainable Development De Montfort University
Sustainable Design within BSF: A Case Study of the City of Leicester College Liam Murray (Hulley & Kirkwood)
 UK Power Networks. All rights reserved Distribution Network Visibility Low Carbon Networks Fund Tier 1 project UK Power Networks & PPA Energy Omer.
Smart Building Control David McEwan
Timber Research Centre Michael Anderson– Mohamed Farid Pablo Prallong – Lewis Macleod Ross Turbet & Group A 26/04/20054 th Presentation.
IEA HPP Annex 28 Calculation method Workshop IEA HPP Annex 28 8 th International Heat Pump Conference, Las Vegas, 30 May 2005 Carsten Wemhöner, Operating.
May 11, The role of electric mobility in future Energy Systems Dr. ir. Zofia Lukszo With collaboration with dr. Remco Verzijlbergh Section Energy.
Creating LV network templates Gavin Shaddick 5 th November 2012.
20 10 School of Electrical Engineering &Telecommunications UNSW UNSW 1 2 3b 3a 1 10 Author – Joshua Weston Supervisor – Dr. Iain MacGill.
GreenSTEP Statewide Transportation Greenhouse Gas Model Cutting Carbs Conference December 3, 2008 Brian Gregor ODOT Transportation Planning Analysis Unit.
Renewable Technologies Available in Ireland Paul Kane.
1 Load Forecast and Scenarios David Bailey Customer Energy & Forecasting Manager Soyean Kim Rate Design Manager.
Energy Dr Michael McCann Centre for Sustainable Technologies (Professor Neil J Hewitt)
IEA HPP Annex 28 Calculation of compact units Workshop IEA HPP Annex 28 8 th International Heat Pump Conference, Las Vegas, 30 May 2005 Thomas Afjei, Institute.
LEAP analysis of mitigation options for greenhouse gas emissions. Palmerston North case study.
27/09/2014- Sustainable Places– Nice PAGE 1 Matthieu COSNIER - Daniel QUENARD Direction Energie Environnement CSTB Grenoble NZEB & EV for Energy Positive.
Carbon Emissions and the Need for Improved Energy Efficiency.
IEA Annex 37: Demonstration of field measurements of heat pump systems in buildings – Good examples with modern technology Jenny Love 8 th March 2013.
A Closer Look at Energy Demands: Quantification and Characterisation.
16469 Low Energy Building Design Conflict and Interaction in Environmental Engineering Design.
Microgeneration Karl Letten – Change Programme Support Officer (Environment) Change Management.
Carbon Emission Reduction Strategy Analysis Using Geographic Information System Dr. John P Deevairakkam TenneT.
Ulster.ac.uk Heat Pumps and Thermal Storage – Household Implementation to Grid Challenge Professor Neil J Hewitt Director, Centre for Sustainable Technologies.
Case application: Insulation and glazing, The Netherlands Harry Vreuls, NL Agency Workshop: Harmonization in Energy Savings Calculation: How To Fit International.
Multiscale energy models for designing energy systems with electric vehicles André Pina 16/06/2010.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Canadian Energy Research Institute
Dr. Gabrial Anandarajah, Dr. Neil Strachan King’s College London
Generation of Domestic Electricity Load Profiles
Energy Management and Planning MSJ0210
Institute for Energy and Transport
International Renewable Energy Agency
Greater Manchester Sustainable Urban Development Plan (SUD)
Johann ZIRNGIBL CSTB / France
European-wide field trials for residential fuel cell micro-CHP
Comparison of THREE ELECTRICAL SPACE HEATING SYSTEMS IN LOW ENERGY BUILDINGS FOR SMART LOAD MANAGEMENT V. Lemort, S. Gendebien, F. Ransy and E. Georges.
Feasibility Study Phase1 Tianjin YUJIAPU Low-Carbon CBD
bre Innovation Park Visitor Centre:
Energy Policy Statistical Support Unit
Restructuring Roundtable March 24, 2017 Boston, MA
Time Shifting / Storage – Above Ground
11 September 2018 The most acceptable method of water heating for Badock – a University of Bristol Hall of Residence. A Thermal and Financial Model Naomi.
Self-Sustaining and Energy Efficient Buildings in Residential Areas
Heat energy from the sun Thermal characterisation of a latent heat thermal energy storage system by means of a dynamic artificial neural network Presentation.
Energy Saving Concepts and Opportunities in Foundry (A case Study)
Solar City: Effect of Solar Technologies on Network Performance
Nick Kelly, Jon Hand, Aizaz Samuel
EV charging – a grid perspective
NET-ZERO-ENERGY (NZE) WASTEWATER TREATMENT PLANTS (WWTPs)
LOAD MANAGEMENT OF HEAT PUMPS USING PHASE CHANGE HEAT STORAGE
Nick Kelly, Paul Tuohy, ESRU
Shifting the timing of energy demand: A stochastic modelling approach
Unlocking Demand Contribution to Distribution Network Management
Integration of EVs with Existing Distributed Energy Resources in Findhorn Ecovillage Craig mcarthur, Georgios PAPOUTSIS, KONSTANTINOS PISOKAS, MARINOS.
Flexible space heating demand for district heating systems
SOLAR PANELS SAVING IN YOUR HOME!
Case Studies on Field Deployment of PV Battery Storage Systems
Byron Woertz, Manager—System Adequacy Planning
THE STUDY OF SOLAR-WIND HYBRID SYSTEM PH301 RENEWABLE ENERGY
Load Forecast and Scenarios
Byron Woertz, Manager—System Adequacy Planning
Arslan Ahmad Bashir Student No
Ventilation heat recovery
Development of a household occupancy state simulation model for multi-energy load profile generation Residential buildings account for around 30% of the.
Mid-West Consumers Association Annual Meeting December 12, 2018
The Smart Islands programme
John Whybrow Hitachi Europe Programme Lead, Smart Energy
Electricity Distribution and Energy Decarbonisation
Presentation transcript:

Modelling the impact of integrated EV charging and domestic heating strategies on future energy demands Nick Kelly, Jon Hand, Aizaz Samuel ESRU, University of Strathclyde, Glasgow

Overview UK policy & domestic electrification aims role of simulation high temporal resolution solar modelling demand hot water building model EV charging algorithm simulations demand control strategies results conclusions future work

Domestic Electrification UK has a target of 80% GHG emission reductions by 2050 (relative to 1990 levels) electrification of domestic heating and associated vehicle use seen as a means to achieve this coupled with decarbonisation of the UK electricity supply however, serious implications for electricity network increase in electricity use and peak demands

Domestic Electrification

Impacts of Electrification greatly increased electrical energy use increased peak demand possible power quality problems failure of key electrical network components e.g. transformers need for network reinforcement at all levels

Aim of Work assess the potential impact of electrification of heating and vehicle loads on a future high-efficiency UK dwelling and investigate mitigating strategies

Role of Simulation integrated building simulation powerful tool for predicting building thermal performance by extension heat-driven electrical demands (e.g. heat pumps) heat-driven generation (micro-CHP) generation from solar technologies such as PV effects of changes in buildings and climate can be used to generate “realistic” electrical demand data for buildings and assess impacts on end users

Higher Temporal Resolution BS grounded in modelling of building thermal performance tools often run at hourly resolution however this is not suitable for assessment of peak electrical demands … and interaction of a dwelling with LV network requires higher temporal resolution boundary conditions solar (PV output) hot water demand domestic electrical loads

Higher Temporal Resolution electrical demand

High Resolution Solar Data ESP-r’s default climate database holds hourly data for sub-hourly time steps interpolation is used tool developed to generate sub hourly data from hourly datasets (1st order Markov model) [1] transition probabilities need to be calibrated using measured high resolution data temporal definition database (TDF) can hold sub-hourly data (either real or generated) [1] McCracken D 2011. Synthetic High Resolution Solar Data, MSc Thesis, University of Strathclyde, Glasgow.

Electrical Demand tool developed by Richardson [2] adapted to pre-simulate annual domestic electrical demand at 1-min resolution … and corresponding thermal gains pre-simulated data held in TDF used as a boundary condition by ESP-r’s electrical systems solver [2] Richardson I, Thompson M, Infield D, Clifford C 2010. Domestic electricity use: A high-resolution energy demand model. Eng. and Build. 42(10) pp 1878-1887.

Hot Water Draws work of Jordan and Vagen [3] (IEA SHC Annex 26) used to generate new stochastic hot water draw component in ESP-r determines if hot water draw takes place ,draw flow rate and duration at each simulation time step (at up to 1-min resolution) model also used as basis of draw profiles generated in IEA ECBCS Annex 42 [3] Jordan U and Vajen K, 2005. DHWCALC: Program to Generate Domestic Hot Water Draws with Statistical Means for User Defined Conditions, Proc. ISES Solar World Congress, Orlando, US.

‘Zero-Energy’ Building Model future UK family dwelling used as basis for modelling ~ 90m2 insulated to Passivhaus standard 8kWp PV installation on monopitch roof A++ appliances and LED lighting data used to generate electrical demands PV output covers electrical demand … but not EV demand

Zero-Energy Building Model space and water heating from buffered (500L tank) ASHP MVHR with heating coil in supply 4m2 roof mounted solar collectors 200L SDHW tank 200L grey water heat recovery tank

EV Charging Algorithm probabilistic EV charging algorithm developed for ESP-r calculates real power draw or injection from EV battery vehicle presence calculation vehicle state (charging/idle/absent) trip distance estimation SOC tracking multiple charging strategies uses data from UK transport survey to determine trip probability

EV Charging Algorithm

Simulations model used to predict the total electrical demand of the dwelling accounting for: heat pump (space & water heating loads) appliance and lighting demands (pre-calculated) EV demands PV generation performance simulated Jan/Feb UK climate: “worst case” 1-min time resolution

Simulations used in assessing the impacts of different ASHP and EV operating strategies Base Case – no EV, no Heat Pump The house is assumed to be heated using biomass and there is no EV. Case 1 – unrestricted slow charging Both heating system operation and vehicle charging are uncontrolled. The vehicle is slow charged (3.3kW – up to 6.5 hrs) when it returns from trips and heat is supplied when required. Case 2 – Unrestricted fast charging Both heating system operation and vehicle charging are uncontrolled. The vehicle is fast charged (6.6kW – up to 3hrs) when it returns from trips and heat is supplied when required. Case 3 – load sensitive vehicle battery slow- charging The vehicle battery is only slow charged at full power if the dwelling and vehicle demand would be less than 7.5 kW. Case 4 – load sensitive vehicle battery fast- charging The vehicle battery is only fast charged at full power when the overall dwelling and vehicle demand would be less than 7.5 kW. Case 5 – off-peak heating and unrestricted slow charging The heating buffer tank (figure 5) is charged during off peak periods (11 pm – 7am), slow vehicle charging is unrestricted. Case 6 – off peak heating and unrestricted fast charging The heating buffer tank (figure 5) is charged during off peak periods (11 pm – 7am), fast vehicle charging is unrestricted. Case 7 – off peak slow charging and heat load shifting Both slow vehicle charging and heating system buffer tank charging are shifted to off peak periods (11 pm – 7am). Case 8 – off-peak fast battery charging and heat load shifting Both fast vehicle charging and heating system buffer tank charging are shifted to off peak periods (11 pm – 7am).

Simulations Load restricted fast EV charge Load restricted slow EV charge Off peak heat pump, fast EV charge Unrestricted fast EV charge Off peak heat pump and off-peak fast EV charge Off peak heat pump and off-peak slow EV charge Off peak heat pump, slow EV charge Unrestricted slow EV charge Base case

Distance travelled (km) Maximum charge time (mins) Results electrical Scenario Base Case 1 2 3 4 5 6 7 8 Elec. demand (kWh) 387.8 1106.1 1136.9 1081.2 1074.6 1137.6 1133.3 1124.1 1144.2 EV demand (kWh) - 395.8 426.4 379.8 365.0 443.4 408.8 425.9 Appl. demand (kWh) 463.7 ASHP demand (kWh) 279.8 273.9 271.6 269.7 269.1 PV output (kWh) 223.7 Elec. export (kWh) 139.3 112.9 116.1 110.1 118.5 106.3 116.3 128.2 Self-consumption (kWh) 84.4 110.8 107.6 113.6 105.2 117.4 107.4 95.5 BOP and losses kWh 160.4 144.0 134.7 149.9 131.0 156.6 133.9 113.1 Max P demand W 5116.52 10083.6 12222.1 8019.2 8251.6 7960.6 11327.5 9088.0 11571.9 Max P export W 2287.16 2239.83 2239.8 EV Scenario Base Case 1 2 3 4 5 6 7 8 EV demand (kWh) -  395.8 426.4 379.8 365.0 443.4 408.8 425.9 Distance travelled (km)  - 2388.4 2588.7 2292.4 2219.6 2673.5 2547.2 2620.3 Return trips (-) - 107.0 112.0 111.0 109.0 103.0 105.0 Maximum charge time (mins) 328.0 172.0 368.0 190.0 348.0 1156.0 998.0 Mean SOC (%) 97.1 98.3 96.8 99.0 96.0 74.1 78.2 Heat pump Scenario Base Case 1 2 3 4 5 6 7 8 ASHP demand (kWh) - 279.8 273.9 271.6 269.7 269.1 ASHP heat output (kWhrs) 858.5 841.3 839.3 832.1 833.8 832.3 Mean air temp. occupied hours (oC) 21.4 21.3 21.2 % of time air temp < 18oC 0.17 0.1 0.2 3.9 4.1 Mean hot water temp. hours (oC) 53.8 54.0 54.1 53.3

Key Results - Electrical electrical energy use

Key Results - Electrical peak electrical demand

Key Results - EV vehicle trips

Key Results - EV mean SOC

Key Results - ASHP low indoor air temperatures

Conclusions building simulation used to assess impact of domestic electrification ASHP, EV, PV model of zero carbon UK dwelling developed ESP-r tool adapted to use higher resolution boundary data adapted to generate high resolution solar data, appliance demand/thermal gains and hot water draws algorithm developed to mimic effect of EV charging on household power demand demand peak mitigation strategies tested

Conclusions addition of EV and ASHP more than doubles annual electrical energy use peak demand doubles with unrestricted EV & ASHP use load sensitive EV charging successful in reducing demand for both fast and slow charging (but still 60% higher than base case) load shifting ASHP to off peak only effective coupled with slow charging load shifting both ASHP and EV to off peak counter productive

Conclusions EV availability not significantly affected by charging restrictions or rate Off peak EV charging reduced mean SOC and possibly number of trips Off peak heating resulted in deterioration in ASHP performance

Further Work extension to transition and summer periods more specific EV use modelled e.g. “commuter” modelling additional ASHP operating strategies and ASHP/EV combinations ASHP modulation (algorithm adaptation) modelling of populations of buildings and householders modelling in different building types modelling with future climates

Acknowledgements this work was undertaken as part of the UKRC Energy Programme - Grand Challenge in Energy Systems: Top and Tail Transformation

Thank you!