Fujitsu Training Documentation Hardware Installation

Slides:



Advertisements
Similar presentations
MX250 Power on and off, Console Mode. January 2004 Page 2 Power Supply MX250 has ac and dc inputs –ac 100 to 240 V, 5A, 50 to 60 Hz –dc –48 V, 6A –worldwide.
Advertisements

…performance audio networks. ABOUT RockNet => RockNet provides ultra low latency and very high audio quality. Genuine Audio Technology  RockNet is a.
Department of Environmental Conservation 1 DATAMAX PRINTER SETUP MODULE 1.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
5.3 Installing the blade server in a BladeCenter unit.
Networking By: Matt Motl… Programmer Brent Everson… Programming Mentor.
PowerEdge M-Series CMC Management
SGI Confidential Copan 400 Installation. SGI Confidential Installation Overview The approximate minimum time to complete this procedure is.
Ch. 6 – Switch Configuration CCNA 3 version Overview Identify the major components of a Catalyst switch Monitor switch activity and status using.
1 © 2004, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.1 Module 6 Switch Configuration.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment Chapter 2: Managing Hardware Devices.
Module 8 Installation & Setup M1000e Chassis
AccuMax Multi-Point Injection Mechanics
Part 1 Using the ARM board And start working with C Tutorial 5 and 6
Ch. 5 – Access Points. Overview Access Point Connection.
9000U Quick Guide Marketing & RMA Department XELTEK 8/28/2015.
LION GES - Overview  Fast Ethernet Switch For easy installation of medium to large sized networks For installation of high availability networks using.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 22 All About SCSI.
70-290: MCSE Guide to Managing a Microsoft Windows Server 2003 Environment, Enhanced Chapter 2: Managing Hardware Devices.
Module 6 – Switch Configuration CCNA 3 Cabrillo College.
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
Available at: – Operate the Tumbler using a Jumper Pin Operate the Tumbler using the jumper pin.
Ch. 6 – Switch Configuration
GCS 300 System Operation Application – Level 1.
1 Installation Training Everything you need to know to get up and running.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 2: Introduction to Switched Networks Routing And Switching 2.0.
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Chapter 3 System Buses.  Hardwired systems are inflexible  General purpose hardware can do different tasks, given correct control signals  Instead.
How to setup DSS V6 iSCSI Failover with XenServer using Multipath Software Version: DSS ver up55 Presentation updated: February 2011.
PIM Technical Training, December 2011 Brian Whitcomb 12/20/2011 Call-in Number = Pass code =
 Charging and Syncing the iPod Touch Cart Lesson 2.
Hardware Configuration Guide Configuring Dongles and Creating Barcodes for Devices Used with VSC.
© 2005 Avaya Inc. All rights reserved. Avaya – Proprietary & Confidential. For Limited Internal Distribution. The information contained in this document.
EVA4400 Controller and Management Module
Chapter Objectives In this chapter, you will learn:
Avaya VA Line-interactive UPS
Do-more Technical Training
Fujitsu Training Documentation Online Storage Migration
ABB i-bus® KNX Valve Drive Actuator VAA/A
Lec 3: Introduction to Switched Networks
Always Connected introduces Tigo SMART 3.0 This guide is interactive!
KX-NS1000 Initial Set Up Rev Oct.,
Fujitsu Training Documentation RAID Groups and Volumes
Fujitsu Training Documentation Hardware Installation
ETERNUS DX100 S3, DX200 S3, DX500 S3 and DX600 S2
Wireless 3 Buttons Touch Panel
Redundancy Switching Components
K TO 12 CHS MODULE FOR GRADE 9, PP
EnTrans Technology Co., Ltd.
Chapter 5: Switch Configuration
Module 1: System Overview
Chapter 2: Introduction to Switched Networks
Chapter 2: Introduction to Switched Networks
HOW TO RESET BROTHER PRINTER HL 2250DN Quick step up Guide to reset your Brother Printer HL 2250DN
Chapter 5: Switch Configuration
What’s in the Box?.
The New RAPID TPM A NEW PLATFORM FOR TURBO PETROL ENGINES Leading name in the world of the additional module applied to Turbo Diesel engines for over.
MicroEconomix 1500 RSLogix 500 LAB#1
Chapter 5: Switch Configuration
PHASE IDENTIFICATION UNIT (PIU)
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
Digital Chart Recorder Operation
VEXnet User's Guide.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
William Stallings Computer Organization and Architecture 7th Edition
How To Use The FD92 Digital Camera
KX-NS Step by Step Guide Initial Setup
Presentation transcript:

Fujitsu Training Documentation Hardware Installation Hardware Installation ETERNUS DX500 S3 and DX600 S3 ETERNUS DX500 S3 and DX600 S3 Hardware Installation Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Hardware Installation ETERNUS DX500 S3 and DX600 S3 Content Rack Mounting Power Cabling DX500 S3 / DX600 S3 Backend Architecture Backend Cabling QSFP Power On / Power Off Procedures CE Switch Panel - Function Buttons Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Rack Mounting Hardware Installation ETERNUS DX500 S3 and DX600 S3 Fit the Controller Enclosure and/or Drive Enclosure to the rack For more and detailed information use the Hardware Installation Guide for the ETERNUS DX Midrange S3; inp-R14B-1418-01EN1) For better stability installation of hardware in a rack has to start from the bottom Always have tilt prevention in place when installing HD-DE Make sure in advance that the maximum load capacity of the raised floor construction is not exceeded when installing High Density Drive Enclosures (that can be extremely heavy when fully populated) Controller Enclosure: maximum 54 kg Drive Enclosure: maximum 35 kg HD Drive Enclosure: maximum 95 kg 1) At the end of the file name 01 refers to first released version and EN refers to language variant English Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Power Cabling Hardware Installation ETERNUS DX500 S3 and DX600 S3 For FTS (CEMEA&I) only Connect the rack PDUs (Power Distribution Units) to independent AC power phases Make sure that the AC power switches on each Enclosure are turned off before connecting their power cables Connect each Power Supply of an Enclosure to different Power Distribution Units Left Rack PDU Right Rack PDU PSU#0 inlet PSU#1 inlet Always follow the local power cabling regulations! PSU#0 inlet PSU#1 inlet Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX500 S3 Backend Architecture Fujitsu Training Documentation DX500 S3 Backend Architecture Hardware Installation ETERNUS DX500 S3 and DX600 S3 Diskless Controller Enclosure 2x PCIe 3.0 links used as CM inter-communication paths 1x IOC (SAS I/O Controller) per CM Redundant paths to DEs 1x SAS-3.0 Expander per CM Provides 2x independent SAS bus connectors Each SAS backend pair supports maximum of 11 DEs SAS QSFP cable (external) 2 backend SAS pairs Each port supports SAS 12G 4 parallel SAS lines BUD Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX600 S3 Backend Architecture Fujitsu Training Documentation DX600 S3 Backend Architecture Hardware Installation ETERNUS DX500 S3 and DX600 S3 Diskless Controller Enclosure 2x PCIe 3.0 links used as CM inter-communication paths 2x IOC (SAS I/O Controller) per CM Redundant paths to DEs 1x SAS-3.0 Expander per CM Provides 4x independent SAS bus connectors Each SAS backend pair supports maximum of 11 DEs SAS QSFP cable (external) 4 backend SAS pairs Each port supports SAS 12G 4 parallel SAS lines BUD Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation SAS Backend Cable QSFP Hardware Installation ETERNUS DX500 S3 and DX600 S3 Follow the SAS port labels at the Enclosures This will point to the correct cabling This sign means "IN" and this sign means "OUT" Connect the cables according the labels showing the direction Cable end marked with plug into Enclosure connector marked with SAS ports of the Controller Enclosure always have the type "OUT" QSFP Cable Is a twin-cable with a Mini SAS connector at its end The cable has a blue release tab that must be applied when removing the cable from the connector Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX500 S3 Backend Cabling QSFP (1) Fujitsu Training Documentation DX500 S3 Backend Cabling QSFP (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Drive Enclosure expansion Connect SAS (OUT) ports with SAS (IN) ports 2 ports (2 paths) are provided for SAS (OUT) per CM IN OUT IN OUT Drive Enclosure# 10 IN OUT IN OUT Drive Enclosure #00 C M # 1 Controller Enclosure C M # 0 SAS Port # 0 SAS Port # 1 SAS Port # 0 # 1 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX500 S3 Backend Cabling QSFP (2) Fujitsu Training Documentation DX500 S3 Backend Cabling QSFP (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 QSFP cables in lengths 3.5 m and 6 m are available for forward and reverse cabling DX 500 S3 supports up to 11 DEs per each (2) SAS bus 2nd DE must be connected to the second SAS bus DE#12 OUT IN DE#02 OUT IN DE#11 OUT IN DE#01 OUT IN DE#10 OUT IN DE#00 OUT IN IOM#0 IOM#1 #1 #0 CE DX500 S3 CM#0 CM#1 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX600 S3 Backend Cabling QSFP (1) Fujitsu Training Documentation DX600 S3 Backend Cabling QSFP (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Drive Enclosure expansion Connect SAS (OUT) ports with SAS (IN) ports 4 ports (4 paths) are provided for SAS (OUT) per CM IN OUT IN OUT Drive enclosure 30 IN OUT IN OUT Drive enclosure 20 IN OUT IN OUT Drive enclosure 10 IN OUT IN OUT Drive enclosure 00 Controller enclosure #0 #1 SAS Port #2 #3 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX600 S3 Backend Cabling QSFP (2) Fujitsu Training Documentation DX600 S3 Backend Cabling QSFP (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 QSFP cables in lengths 3.5 m and 6 m are available for forward and reverse cabling DX 600 S3 supports up to 11 DEs per each (4) SAS bus All SAS buses must be populated before adding a second DE to the first bus Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Advantage of Reverse QSFP Cabling Fujitsu Training Documentation Advantage of Reverse QSFP Cabling Hardware Installation ETERNUS DX500 S3 and DX600 S3 In the extremely rare case of a complete DE failure all HDDs remain accessible in all surviving DEs No longer accessible Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

DX Midrange S3 HD-DE Expansion Fujitsu Training Documentation DX Midrange S3 HD-DE Expansion Hardware Installation ETERNUS DX500 S3 and DX600 S3 Maximum number of HD-DEs DX500 S3 8 when the total number of HDDs does not exceed 528 16 when the total number of HDDs does not exceed 1056 DX500 S3 DX600 S3 Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Power On Procedure (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 The ETERNUS DX S3 systems can be powered on from the Controller Enclosure Push the Power Switch The Power Switch of the CE lights green The power on sequence takes about 2 minutes If everything is OK, the green Ready LED in the CE and the green Power LED in the DE switch on ID Fault Power Power Ready Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Power On Procedure (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Controller Enclosure LEDs POWER SWITCH with integrated LED Constant green when the power is turned on READY LED Constant green when device is available for use FAULT LED Constant amber when a failure is detected in the ETERNUS DX system Blinks in amber when a component which requires preventive maintenance is detected MAINT LED Constant green when the system has its status set to Maintenance IDENTITY LED Constant blue when locate functionality is enabled by the GUI or CLI CACHE LED Constant green when data exists in cache memory Blinks in green when cached data is saved to the flash memory Remote LED Constant green when the system is turned on and off by additional external hardware Power switch Power indicator Fault Identify Maintenance Cache Ready Remote Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Power On Procedure (3) Drive Enclosure LEDs Identical for 2.5" and 3.5" DE IDENTIFY LED Constant blue when locate functionality is enabled by the GUI or CLI POWER LED The Drive Enclosure is operating normally and was switched on by the CM DE-ID (7-segment) Shows a 2-digit Drive Enclosure ID First digit is the SAS bus number DX500 S3: "0" and "1" DX600 S3: "0", "1", "2" and "3" Second digit is the DE number "01" = DE#1, "14" = DE#4… "3A" = DE#10 The ID is assigned automatically by the SAS backend cabling during the Add DE procedure DE ID Identify Fault Power Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Power Off Procedure Hardware Installation ETERNUS DX500 S3 and DX600 S3 Verify with the customer that all server I/O is stopped Also confirm that the Cache LED in the Operator Panel is off Hold down the power switch of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will shutdown all Enclosures gracefully In case of moving ETERNUS to a new location, you naturally have to also disconnect the AC power cords from the PDUs after the system is powered off Make sure the Cache LED of the Controller Enclosure is off Power switch Cache Ready Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

CE Switch Panel - Function Buttons (1) Fujitsu Training Documentation CE Switch Panel - Function Buttons (1) Hardware Installation ETERNUS DX500 S3 and DX600 S3 Remove the CE front bezel to get access to the Function Buttons Located above the Power Switch Use the pin tool to operate one of the following functions See next slide for further details Enable / disable Maintenance Mode Change CM Master Reset the IP address of the FST port to factory default Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

CE Switch Panel - Function Buttons (2) Fujitsu Training Documentation CE Switch Panel - Function Buttons (2) Hardware Installation ETERNUS DX500 S3 and DX600 S3 The operation can be performed by carrying out the following steps To toggle the system status between "Maintenance" and "Normal" Keep the Function Button pushed for three seconds The MNT LED lights green when the system is in Maintenance mode The MNT LED is off when the system is in Normal mode Switch the functionality of Master CM to the other Controller Module (1) Switch on "Maintenance Mode" (2) Push down the Function Button twice within three seconds The Master LED lights green to indicate the Master CM (3) Switch off "Maintenance Mode" Reset the FST port of the CM to the default values (2) Push down the Function Button three times within three seconds The MNT LED blinks green for a few seconds Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014 Copyright Fujitsu, Release May 2014

Fujitsu Training Documentation Hardware Installation ETERNUS DX500 S3 and DX600 S3 Copyright Fujitsu, Release May 2014