ProtoDUNE SP – Slow control Status

Slides:



Advertisements
Similar presentations
PRIMARY CONTROLLERS AMERICAS REGION HVAC Products
Advertisements

Engineer Training Supply Unit TJ8300 / TJ8500 Supply Unit.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
I have almost 20 years experience in the components and devices used in industrial control, instrumentation and automation applications. Before I came.
Power distribution box XD1 top DTTF_Crate XD2 middle DTTF_Crate XD3 bottom DTTF_Crate Connection to DTTF_Crate through cable USE H07 ZZ-F 3G1,5 RACK S1D01.
Siemens Building TechnologiesRWD heatpump controllers Xavier Zabalegui/David Jefferson 1 January 2003 RWD Heat Pump controllers RWD Heat Pump Controllers.
ESE Lab Computer based Temperature Control Sid Deliwala, ESE Labs.
DP Cabinet.
Programmable Logic Controller
PYROCON12 De-Ice controller User Operation Presentation 2013.
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
Lab #2 – Power Supply. © Bob York Back to TOC 2 © Bob York Back to TOC 3 Linear Power Supply.
PH/DT MCP & MNO NEW MAGNET SAFETY SYSTEM HARDWARE Sylvain Ravat PH-DT Xavier Pons PH-DT.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
Programmable logic control Data Processing Computer System Key Board Light Pen Mouse PLC a Process Control Computer System Motion Sensor Sound Sensor.
7526A Precision Temperature/Pressure Process Calibrator
Low Voltage Power Requirement of TOF FEEs. Maximum tray. Low Noise:  Periodic and Random Distortion (PARD) < few mV RMS Floating.
Single Loop Analogue addressable fire control Panel
Modular Inverter.
Vacuum Controls Status MACS week December 2010 PP a-JWA-VacControlStatus.ppt Joachim Wallner 1.
Regulation Electrical pressure regulation provides  Accurate control  Quick response time  Additional Safety features Electrical temperature control.
TE/MPE/EE J. Mourao T/MPE/EE 1 November 2012 LHC Machine Local protection Redundant Power supply (DQLPUR) & interface Module (DQLIM) progress status.
MICE RF System Power Supplies, Control and Monitoring Status report February 2012 Chris White, STFC Daresbury Laboratory MICE Collaboration Meeting CM32,
André Augustinus 16 June 2003 DCS Workshop General Purpose Monitor.
EeePC – Ubuntu Running pvMon USB cable Phidget I/O Controller Photovoltaic panel Power/System Connections I V PV charger Cont. Phidget I/O Controller +12.
E.Sbrissa EP/TA3 - IC ATLAS EDR_MAG Magnet Project Fault analysis, QA & Failure rate.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
April 24, 2015 FlexBus TM and FlexCards TM. 2 © Red Lion Controls Inc. FlexBus What is FlexBus?  A parallel bus that expands the option card capability.
MARCO control system Munich Lukasz Zwalinski – PH/DT Maciej Ostrega – PH/DT.
S A Griffiths CM42 June 2015 Electrical & Control.
CERN Giovanna Lehmann, Xavier Pons
User Operation Presentation
NEW RMC Rack Multi Control.
Status CO2 Cooling IBBelle: Reconnection after Belle II Roll in
ProtoDUNE SP – Slow control temperature gradient monitor
2500 Series® Compact System Components
Status & Plans for WA105 Control System
ProtoDUNE - SP SLOW CONTROLS MEETING 11/11/2016 CERN – EP/DT
MICE RF System Power Supplies, Control and Monitoring Status report
PLC Terminology and Application
FTK infrastructure in USA15 Status and plans for 2015 A
ProtoDUNE SP – Slow control temperature readout setup test
SCADA for Remote Industrial Plant
PRESENTATION ON AUTOMATION,PLC AND SCADA
Christian Veelken last updated 11/09/06
Different Types of Relays.
How SCADA Systems Work?.
EPR = Electronic Products and Relays
LDA Large Display for Analog Inputs
FEEDER PROTECTION UNIT
The D.C. Scout Battery Distribution System Ground Locator
HVI HIPOT TEST SET Pft sERIES.
Programmable Logic Controllers (PLCs) An Overview.
PLC Hardware Components.
ET 438B Sequential Control and Data Acquisition
Technician Operation Presentation
Vertical Cryostat Kick-off metting
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
CECOM LAR Tropo Operation Course
PAX2A Release.
Series 5300 Lithium Cell Formation System
easYgen-3000XT Series Training
Delta Heater Introduction
Detailed information FOR INTERNAL USE ONLY! CUBE20.
ICARUS Internal Cryogenic Sensors
We are working on developing “cheap” RTD monitoring channels for the CMS Phase-2 requirements. The channels will provide the complete readout for 4-wire.
Automatic operation IR rework system Automatic Component placement 2 x K-type thermocouples IR-pyro sensor RPC-camera.
Presentation transcript:

ProtoDUNE SP – Slow control Status Giovanna Lehmann – Xavier Pons CERN 10/08/2017

protoDUNE Slow Control Rack Zone Status on 03/08/2017 11 Racks already available and mechanically assembled HV Heinzinger missing Rack 0 Impedance Monitor rack Single Phase Transformer Rack 0 Impedance Monitor rack Dual Phase

Temporary 220Vac power distribution for coldbox equipment protoDune Single Phase – DCS Rack Zone on 10/08/2017 Main Power Switch From secondary transformer Installation of the power circuit for the coldbox instrumentation on detector ground Temporary 220Vac power distribution for coldbox equipment

Last week 0n 03/08/2017 ‘About the coldbox, the 6 PT100 will be installed Monday afternoon, along the red bar’

Installation of the RTD sensors inside the Coldbox bar on 08/08/2019

Detail of the RTD connection on top of the Coldbox

Coldbox DCS The main features are:   Two AC/DC power supply: one 24 VDC for general DCS controller, fan on/off, pressure sensor power supply and a 12VDC (adjustable) power supply for the heaters. Both AC/DC power supplies are powered by 220Vac detector side. DCS controller : Siemens S7-1500 (CPU1511) Supplier link https://www.siemens.com/global/en/home/products/automation/systems/industrial/plc/simatic-s7-1500.html The PT100 either for the coldbox either for heaters are read by the analogue input Siemens with a accuracy +/- 0.1C The heater ON/OFF power and fan ON/OFF are controlled by a digital output connected to an solid state isolated relay, Phoenix Contact manufacturer link: relay Each individual heater or fan heater are individually fuse protected. The temperature regulation is programmed inside the DCS controller, to be defined but we have already a default sequence. The controller is connected to PC through Ethernet with the CERN WINCC supervisor software and with CERN UNICOS framework installed On detector ground

Interface – Controller to Coldbox Instrumentation MAIN DCS Controller – Siemens S7-1500 Programmed with CERN UNICOS Framework package Back Side – Connector Input

Wincc Supervisor